• 제목/요약/키워드: PM tube

검색결과 405건 처리시간 0.025초

화력발전소 굴뚝 미세먼지 측정을 위해 개발한 이젝터-다공튜브 희석장치의 희석비 검증 (Verification of dilution ratio of the newly developed ejector-porous tube diluter for measurement of fine dust in coal-fired power plant stack)

  • 신동호;김영훈;서현수;홍기정;김학준;김용진;한방우;이가영;천성남;황정호
    • 한국입자에어로졸학회지
    • /
    • 제15권3호
    • /
    • pp.105-113
    • /
    • 2019
  • The exhaust emissions from coal-fired power plants have received much attention because coal-fired power plants are the one of the largest sources of particulate matter (PM) emissions in South Korea. To measure the PM10 and PM2.5, we developed the novel diluter which is comprised of ejector and porous tube in series. The dilution ratio must be defined to calculate particle concentrations of the sampled air as well as to probe match for the isokinetic sampling. For this reason, we verified the dilution ratio of the developed diluter by the flow rate, numerical solution, gas concentration and particle concentration. The ejector-supplied flow rates were 10-50 L/min and the porous tube-supplied flow rates were 30, 50 L/min in this study. All methods above showed similar dilution ratios to each other within 10 % error rate. The dilution ratio was confirmed by comparing mass concentrations before and after the dilution process.

Impact performance study of filled thin-walled tubes with PM-35 steel core

  • Kunlong Tian;Chao Zhao;Yi Zhou;Xingu Zhong;Xiong Peng;Qunyu Yang
    • Structural Engineering and Mechanics
    • /
    • 제91권1호
    • /
    • pp.75-86
    • /
    • 2024
  • In this paper, the porous metal PM-35 is proposed as the filler material of filled thin-walled tubes (FTTs), and a series of experimental study is conducted to investigate the dynamic behavior and energy absorption performance of PM-35 filled thin-walled tubes under impact loading. Firstly, cylinder solid specimens of PM-35 steel are tested to investigate the impact mechanical behavior by using the Split Hopkinson pressure bar set (SHP); Secondly, the filled thin-walled tube specimens with different geometric parameters are designed and tested to investigate the feasibility of PM-35 steel applied in FTTs by the orthogonal test. According to the results of this research, it is concluded that PM-35 steel is with the excellent characteristics of high energy absorption capacity and low yield strength, which make it a potential filler material for FTTs. The micron-sizes pore structure of PM-35 is the main reason for the macroscopic mechanical behavior of PM-35 steel under impact loading, which makes the material to exhibit greater deformation when subjected to external forces and obviously improve the toughness of the material. In addition, PM-35 steel core-filled thin-wall tube has excellent energy absorption ability under high-speed impact, which shows great application potential in the anti-collision structure facilities of high-speed railway and maglev train. The parameter V0 is most sensitive to the energy absorption of FTT specimens under impact loading, and the sensitivity order of different variations to the energy absorption is loading speed V0>D/t>D/L. The loading efficiency of the FTT is affected by its different geometry, which is mainly determined by the sleeve material and the filling material, which are not sensitive to changes in loading speed V0, D/t and D/L parameters.

평활관군의 R-134a 흐름비등에 관한 연구 (R-134a Flow Boiling on a Plain Tube Bundle)

  • 김종원;김정오;김내현
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.9-17
    • /
    • 2001
  • In this study, flow boiling experiments were performed using R-134a on a plain tube bundle. Tests were conducted for the following range of variables; quality from 0.1 to 0.9, mass flux from $8\;kg/m^2s$ to $26\;kg/m^2s$ and heat flux from $10\;kW/m^2s$ to $40\;kW/m^2s$. The heat transfer coefficients were strongly dependent on the heat flux. However, they were almost independent on the mass flux or quality. The data are compared with the modified Chen model, which satisfactorily () predicted the data. Original Chen model, however, did not adequately predict the effect of quality. The reason may be attributed to the flow pattern of the present test, where the bubbly flow prevailed for the entire test range. The heat transfer coefficients of the tube bundle were 6~40% higher than those of the single tube pool boiling.

  • PDF

핀-튜브군에서 배플 길이에 따른 음향공진 (Acoustic resonance by length of acoustic baffle at Finned Tube bank)

  • 방경보;류제욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.98-103
    • /
    • 2003
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a HRSG. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At this tube bank, dominant frequencies of vibration in this system were 43.5, 67.5㎐. The 3$\^$rd/ acoustic natural frequency calculated was 68.5㎐. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}$20%, acoustic resonance could occur. In this system, in order to prevent acoustic resonance, acoustic baffle was installed in the tube bank before operating. But acoustic resonance occurred. So, we evaluate the effect of acoustic mode due to baffle extension length. After investigating, we did revise acoustic baffle to eliminate acoustic resonance effectively.

  • PDF

Two-Phase Flow Distribution and Phase Separation Through Both Horizontal and Vertical Branches

  • Tae, Sang-Jin;Keumnam Cho
    • Journal of Mechanical Science and Technology
    • /
    • 제17권8호
    • /
    • pp.1211-1218
    • /
    • 2003
  • The present study investigated two-phase flow distribution and phase separation of R-22 refrigerant through various types of branch tubes. The key experimental parameters were the orientation of inlet and branch tubes (horizontal and vertical), diameter ratio of branch tube to inlet tube (1 and 0.61), mass flux (200-500 kg/㎡s), and inlet quality (0.1-0.4). The predicted local pressure profile in the tube with junction was compared and generally agreed with the measured data. The local pressure profile within the pressure recovery region after the junction has to be carefully investigated for modeling the pressure drop through the branch. The equal flow distribution case can be found by adjusting the orientation of the inlet and branch tubes and the diameter ratio of the branch tube to the inlet tube. The T-junction with horizontal inlet and branch tubes showed the nearly equal phase distribution ratio. The quality at the branch tube varied from 0 to 1 as the orientation of the branch tube changed, while it varied within${\pm}$50% as the orientation of the inlet tube changed.

Video 흉강경을 이용한 폐기포 절제술 (Videothoracoscopic Bullectomy in Patients with Primary Spontaneous Pneumothorax)

  • 김수현
    • Journal of Chest Surgery
    • /
    • 제25권12호
    • /
    • pp.1502-1507
    • /
    • 1992
  • Between February and July 1992, videothoracoscopic bullectomy was performed in nineteen patients with primary spontaneous pneumothorax. The indications of this surgery are recurrent in 12, persistent airleakage in 4 and previous contralateral pneumothorax in 3 patients. For the good operative field, we used double lumen endotracheal tube and put the CO2 gas into the thoracic cavity to make the lung collapse. We usually apply the endoGIA or electric cauterization for handling the bleb or bullae and there were 9 cases with of endoGIA only, 4 electric cauterization only and 6 both procedures. To evaluate the advantage of the Videothoracoscopic surgery, we compared surgical results with that of the tho-racotomy group[19 patients]. There were significant differences in operative time[93.8$\pm$41.9 min and 17.1$\pm$53.9 min, p< 0.01] and postoperative airleakage duration[35.6$\pm$113.3 hours and 117.9$\pm$214.4 hours, p<0.05] between the Videothoracoscopy and thoracotomy group. Tube indwelling time was shortened in Videothoracoscopy group[p<0.05]. The hospital stay was very short[p<0.01] and the patients needed analgesic injection less frequentley in videthoracoscopic group[p<0.05] In conclusion, we prefer the Videothoracoscopic procedure to the thoracotomy in uncomplicateed patients with pneumothorax because of simple procedure and good results.

  • PDF

Fibrin Glue가 자연기흉의 재발에 미치는 영향 (The Effect of Fibrin Glue as a Prevention Against Spontaneous Pneumothorax)

  • 이석열
    • Journal of Chest Surgery
    • /
    • 제24권6호
    • /
    • pp.570-578
    • /
    • 1991
  • The spontaneous pneumothorax is the sudden collapse of the lung usually by air leakage from the ruptured sub-pleural bleb and has high recurrence rate. For prevention against recurrence, many drugs such as tetracycline, talcum powder, quinacrine, etc. have been used but the effects are not satisfactory. We reduced the recurrence rate successfully by the fibrin glue instillation through the chest tube. From the January 1989 to September 1990, we have managed 65 patients of spontaneous pneumothorax with closed thoracostomy and fibrin glue[fibrinogen 1gm/50ml with approtinin 3, 000kIU /ml, thrombin 5, 000IU /ml in 3% each 10ml] instillation through the chest tube. And we compared the results with those of 106 patients of spontaneous pneumothorax who were managed only by the closed thoracostomy from January 1985 to December 1988. Only the patients who visited our hospital with recurrence were considered as the recurred cases but the others were considered as not recurred. And the removal of chest tubes usually done 3 days after cessation of air leakage or 2 days after fibrin glue instillation Statistical analysis was done by X2-test. The results were as followings: 1. The recurrence rate of fibrin glue instillation group was lower than that of non-instillation group[1st attack: 15.1% versus 27.6% p<0, 05, the 2nd attack: 33.3% versus 73.7% p<0.01, the total 18.5% versus 35.8% p<0.01]. 2. The mean duration of chest tube drainage in the fibrin glue instillation group was shorter than non-instillation group[4.24$\pm$1.36 days versus 4.48$\pm$1.73 days p<0.05]. 3. The mean duration of hospitalization was shorter in the instillation group [8.12$\pm$3.5 days versus 10.8$\pm$3.8 days p<0.05] The complications were transient mild fever, chest pain, pleural effusion in 46 cases of 65 patients, but those didn`t make any problem. We concluded that the fibrin glue is effective in the reduction of recurrence rate, obliteration of air leakage and duration of hospitalization.

  • PDF

STS 316L 교정시험편을 이용한 재가열기 튜브의 와전류신호와 초음파 IRIS 신호 특성 (Eddy Current and Ultrasonic IRIS Signal Characteristics of Reboiler Tube by Using STS 316L Calibration Specimen)

  • 탁경주;김병일;국진선
    • 비파괴검사학회지
    • /
    • 제32권1호
    • /
    • pp.56-63
    • /
    • 2012
  • 본 연구에서는 가공된 오스테나이트계 STS 316L ASME 표준 교정시험편을 이용하여 튜브 두께 감소율과 잔존두께에 대한 와전류 신호와 IRIS 신호특성을 비교하여 리보일러 튜브의 현장 적용성을 평가하였다. 그 결과 두께감소율의 경우 와전류탐상검사는 $20%{\times}4$ 평저공, 10% 외면 그루브, IRIS는 80%홈, 10%외면 그루브에서 ${\pm}15%$ 이상의 편차가 발생하였다. 잔존두께의 경우 와전류탐상은 측정치가 모두 허용범위를 만족하였으나, IRIS는 80% 인공홈에서 ${\pm}15%$ 이상의 편차가 발생하였다. 따라서 와전류탐상검사 후 의사지시에 대한 해석, 두께감소율 측정을 위해 IRIS를 수행한다면 신뢰성이 향상될 것으로 판단된다.

호흡기류를 동압력으로 변환하는 기능성 일회용 호흡관 (Functional disposable use flow tube converting the respiratory air flow rate into averaged dynamic pressure)

  • 김경아;김현식;이태수;차은종
    • 센서학회지
    • /
    • 제11권3호
    • /
    • pp.125-131
    • /
    • 2002
  • 호흡기류는 모든 호흡기능검사시 계측해야 하는 필수적인 생체신호이다. 기존에 사용되는 호흡기류 계측기들은 검사의 신뢰도와 위생상의 문제가 상존해 있는 바, 새로운 계측기술을 창안하였다 베르누이의 물리적 에너지 보존원리에 입각하여 양방향 호흡기류를 평균동압력으로 변환함으로써 호흡기류를 계측하는 기법을 도입하였다. 플라스틱 재질의 계측소자를 종이 재질의 호흡관에 체결한 기능성 일회용 호흡관을 설계 제작하였다. 미국 흉부학회의 표준 실험방법에 따라 계측의 정밀도를 평가한 결과 용적계측의 95% 신뢰구간이 약 ${\pm}1.5%$이었다. 미국 흉부학회의 오차기준이 ${\pm}3%$이고 상용센서들의 오차 측정치가 최대 ${\pm}8%$까지 도달함을 닥 때 월등히 정확한 계측이 가능하였다. 일회용으로 설계 제작한 결과 사공간과 위생상의 문제도 없으므로 기존의 호흡기류 계측기술들이 내포하는 문제점들을 모두 제거하였다. 따라서 본 연구의 기능성 일회용 호흡관은 폐활량계와 같은 임상검사를 위한 호흡기류 계측장치에 유용하게 적용될 수 있다.

초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석 (Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.