• Title/Summary/Keyword: PM Point

Search Result 1,374, Processing Time 0.032 seconds

Comparison of Visual Analogue Scale, Categorical Scale and Satisfaction for Postoperative Pain (수술 후 통증 평가를 위한 Visual Analogue Scale, Categorical Scale 그리고 환자 만족도와의 비교)

  • Kim, Yong-Ik;Nam, Sang-Goo;Hong, Seung-Taek;Kang, Kyu-Sik;Park, Wook
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.156-163
    • /
    • 2001
  • Background: The categorical scales and visual analogue scales (VAS) are methods used for evaluating variations of postoperative pain intensity. Several studies have introduced the idea that there is a clear correlation between visual scales and categorical scales. However, when VAS is the only pain measure in the study, we do not know what point on the VAS represents a category on the categorical scale and their degree of correlation with satisfaction for postoperative pain. Methods: 252 patients who had undergone elective surgery were studied. A 5-point categorical scale (none, mild, moderate, severe, worst possible pain), a 0-100 mm VAS (no pain to worst possible pain) and patient satisfaction score were checked 24 hours after surgery using a pain questionnaire and VAS tool. Results: The mean VAS score of the 14 patients reporting 'no-pain' was $1.9{\pm}0.9$, $23.9{\pm}1.0$ for the 132 patients reporting 'mild-pain', $47.2{\pm}1.1$ for the 82 patients reporting 'moderate-pain' and $67.5{\pm}2.8$ for the 24 patients reporting 'severe-pain'. Of the patients reporting moderate pain, 85% scored over 45.6 mm on the corresponding VAS, with a mean score 47.2 mm. The mean satisfaction scores were $90.6{\pm}2.7$ for the 'no pain', patients, $75.1{\pm}1.3$ for ‘mild pain', $58.3{\pm}1.5$ for 'moderate pain', and $55.1{\pm}4.0$ for 'severe pain' patients. The categorical scale was significantly correlated with VAS (P < 0.01). The satisfaction score was significantly inversely correlated with VAS (P < 0.01). Conclusions: Our results indicate that if a patient records a VAS score in excess of 45.6 mm they would probably have recorded at least moderate pain on a 5-point categorical scale. The categorical scale can be used properly for postoperative pain measurement with VAS. More research is required for the development of suitable pain descriptor for a categorical scale and pain questionnaire in Korean.

  • PDF

linical Performance Analysis of Lens for Improving VDT Syndrome (VDT 증후군 개선을 위한 렌즈의 임상성능 분석)

  • Ryu, Geun-Chang;Park, Ji-Hoon;Jun, Jin;Jin Moon-Seog;Chae, Soo-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.45-51
    • /
    • 2009
  • Purpose: The purpose of this study is to compare and analyze the survey results of clinical performance and visual problem, and the survey were carried out before and after of VDT working for 4 hours by wearing functional lens designed for improving VDT syndrome and single-vision lens. Methods: We tested near & far visual acuity, change of spherical equivalent, near point of accommodation, near point of convergence, AC/A ratio, accommodative facility and survey of subjective symptoms to visual problem of before and after VDT working for 4 hours after wearing single-vision lens and functional lens subjected on 30 males and females in the age of 20 to 45. Results: When wearing functional lens comparing to single-vision lens, near visual acuity, near point of accommodation, near point of convergence, and accommodative facility are significantly improved. It is investigated that average scores of 10 items to visual problem after VDT working for 4 hours are 3.63${\pm}$0.75 at single-vision lens and 4.69 ${\pm}$ 0.83 at functional lens, and therefore functional lens is significantly improved. Conclusions: It is thought that functional lens is an excellent lens which helps to improve accommodative function and visual problem after VDT working for 4 hours than single-vision lens.

  • PDF

Biological and Chemical Hazards Factor Analysis for CCP(Critical Control Point) in Fried Process of Fried Noodles (유탕면류의 유탕공정 중 중요관리점(CCP)을 위한 미생물학적, 화학적 위해요소분석)

  • Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3578-3585
    • /
    • 2012
  • The purpose of this study was to establish the critical limit at CCP (Critical Control Point) of HACCP (Hazard Analysis Critical Control Point) system for instant noodle and it was conducted at P company in Ichen(Gyeonggi-do), Korea. According to the CCP, Fried process were experimented to removal and decrease of microbiological and chemical hazards by measuring of each temperature and times. As a result, the standard plate count and pathogenic microorganism were not detected by fried processing (Temperature : $145{\pm}10^{\circ}C$, Time : $75{\pm}30$ sec). The acid value of chemical hazards produced by fried processing was able to manage, showed lower (0.2) than the legal limit (0.6). Air-borne bacterial examination results detected(3 CFU/mL, 3 CFU/mL) in the Frying Room and Steam Room. Therefore, the CCP-BC of fried process would be a great alternative to prevent and remove hazard analysis, such as general and pathogenic microorganism (E. coli O157:H7, B. cereus, Listeria monocytogenes, Salmonella spp, Sthaph. aureus etc), chemical hazard analysis. In conclusion, it suggested that HACCP plan was necessary for management standard and systematic approach in establishement of critical limit, solving the problem, method of verification, education and records management by fried processing.

An Analysis on Factors Related to Health Management & Disease Awareness of Industrial Workers (산업장 근로자들의 건강관리 및 질병에 대한 인식과 관련요인)

  • 전봉천;남철현
    • Korean Journal of Health Education and Promotion
    • /
    • v.13 no.2
    • /
    • pp.1-23
    • /
    • 1996
  • This study was conducted to investigate health management and health awareness of industrial workers and use the information for the development of health education program and the guidline of health management for industrial workers. The survey was carried out on 1,200 workers who were selected from Incheon, Ulsan, Pohang, Masan, Changwon city from Oct. 2 to Oct. 31. 1995. The main results are summarized as follows. 1. With regard to health behavior after regular physical examination, 48.3% of subjests answered "consulting with medical doctors or health workers" and 7.9% answered "non action anything", 2. As for need of environmental control of work, of the total subjects, 96.1% answered "need". 3. As for participation of health education, 61.2% of the subjects were positive, which was higher in male, in higher age groups, in middle school graduates, in healthy group by self assessment than other groups respectively. 4. As for knowledge level of the disease, the average score was $4,97{\pm}1.41$ point to 7 point full mark (71 point to 100 point full mark), the score level was higher in male higher economic, in office workers, in higher education groups, in working period longer groups, in healthier groups, in higher age groups than other groups respectively. 5. As for attitude level of the disease, the average score was $4,70{\pm}1.25$ point to 7 point full mark (67.1 point to 100 point full mark), which was lower, in higher age group, in longer education level, in healthier groups in longer working period than other groups respectively, while the score was higher in male, in day-time workers, in urban residence than other groups respectively.han other groups respectively.

  • PDF

Study on the Characteristics of the Hibernating Site for the Released Asiatic Black Bear in Jirisan National Park (지리산국립공원에 방사한 반달가슴곰 동면장소 특성 연구)

  • Kim, Bo-Hyun;Yang, Doo-Ha;Jeong, Woo-Jin;Lee, Bae-Geun;Skripova, K.V.;Kotlyar, A.K.
    • Korean Journal of Environment and Ecology
    • /
    • v.21 no.4
    • /
    • pp.347-355
    • /
    • 2007
  • Asiatic black Bear(Ursus thibetanus ussuricus) cubs aged one or two were introduced from Russia(Primosky krai) and North Korea for reinforcement of the bear population and they were released to grow wild in Jirisan National Park. We did research on the characteristics of the denning sites of the Asiatic black cubs, which were released before, from Oct. 2004 to Apr. 2006, and the results were as follows: The released bears hibernated in three types of dens,; tree hollows, rock hollows or ground nests. The hibernating sites were dominated by a community of oak trees and its location was at an average of $923{\pm}221m$ height above the sea level ; the average slope incline was $25.9{\pm}7.9^{\circ}$, and the average denning duration was $98{\pm}9$ days. It was analyzed that the cubs' denning site was $2.8{\pm}2.8km$, on an average, far from the release point; $2.0{\pm}0.9km$ far from villages; $1.9{\pm}1.7km$ far from park inspection trails, and $1.9{\pm}1.0km$ on the average far from a driveway. It is assumed that environmental attributes of the denning sites were closely correlated to those of the release points.

Measurement of Five DOF Motion Errors in the Ultra Precision Feed Tables (초정밀 이송테이블의 5 자유도 운동오차 측정)

  • Oh Yoon Jin;Park Chun Hong;Hwang Joo Ho;Lee Deug Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.135-141
    • /
    • 2005
  • Measurement of five DOF motion errors in a ultra precision feed table was attempted in this study. Yaw and pitch error were measured by using a laser interferometer and roll error was measured by using the reversal method. Linear motion errors in the vertical and horizontal directions were measured by using the sequential two point method. In this case, influence of angular motion errors was compensated by using the previously measured ones by the laser interferometer and the reversal method. The capacitive type sensors and an optical straight edge were used in the reversal method and the sequential two point method. Influence of thermal deformation on sensor jig was investgated and minimized by the periodic measurement according to the variation of room temperature. Deviation of gain between sensors was also compensated using the step response data. 5 DOF motion errors of a hydrostatic table driven by the linear motor werer tested using the measurement method. In the horizontal direction, measuring accuracies for the linear and angular motion were within ${\pm}0.02\;{\mu}m$ and ${\pm}0.04$ arcsec, respectively. In the vertical direction, they were within ${\pm}0.02{\mu}m$ and ${\pm}0.05$ arcsec. From these results, it was found that the introduced measurement method was very effective to measure 5 DOF motion errors of the ultra precision feed tables.

Constitution of diffusivity variation system by the smooth morph of the material

  • Kim, Jeong-lae;Hwang, Kyu-sung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.2
    • /
    • pp.39-44
    • /
    • 2018
  • Wideness variation technique is compounded the smooth diffusivity-vibration status of the fulgurate-space realization level (FSRL) on the wideness realization morph. The realization level condition by the wideness realization morph system is associated with the diffusivity-vibration system. As to search a position of the dot situation, we are acquired of the wideness value with constructed-point point by the diffusivity upper structure. The concept of realization level is composed the reference of fulgurate-space level for variation signal by the wideness vibration morph. Further displaying a smooth variation of the FSRL of the maximum-minimum in terms of the diffusivity-vibration morph, and wideness position vibration that was the a wideness value of the far variation of the $Wid-rm-FA-{\alpha}_{MAX-MIN}$ with $23.24{\pm}3.37units$, that was the a wideness value of the convenient variation of the $Wid-rm-CO-{\alpha}_{MAX-MIN}$ with $7.83{\pm}1.32units$, that was the a wideness value of the flank variation of the $Wid-rm-FL-{\alpha}_{MAX-MIN}$ with $2.99{\pm}0.51units$, that was the a wideness value of the vicinage variation of the $Wid-rm-VI-{\alpha}_{MAX-MIN}$ with $0.51{\pm}(-0.01)units$. The diffusivity vibration will be to evaluate at the smooth ability of the diffusivity-vibration morph with constructed-point by the wideness realization level on the FSRL that is displayed the fulgurate-space morph by the realization level system. Diffusivity realization system will be possible to control of a morph by the special signal and to use a wideness data of diffusivity vibration level.

Application of the Equivalent Point Method for Estimation of Kinetic Parameters (Kinetic Parameters 결정을 위한 Equivalent Point Method의 이용)

  • Rhim, Jong-Whan
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.582-589
    • /
    • 1990
  • A method for application of the equivalent time and temperature point for estimating kinetic parameters was proposed. The feasibility of the method was demonstrated with both theoretical and empirical kinetic data. The theoretical kinetic data were obtained from the arbitrarily chosen time-temperature data for three chemical reactions whose kinetics are well established. The experimental kinetic data were obtained for the acid (0.0005 N HCl) catalyzed hydrolysis of sucrose(2%). The activation energy and the frequency factor determined by the proposed method were $104.74{\pm}1.87kJ/mol\;and\;5.62{\times}10^{14}\;hr^{-1}$ respectively and the results agreed well with those obtained by a different method of kinetic parameter estimation, i.e. the linearly increasing temperature method.

  • PDF

A Comparative QSPR Study of Alkanes with the Help of Computational Chemistry

  • Kumar, Srivastava Hemant
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.67-76
    • /
    • 2009
  • The development of a variety of methods like AM1, PM3, PM5 and DFT now allows the calculation of atomic and molecular properties with high precision as well as the treatment of large molecules with predictive power. In this paper, these methods have been used to calculate a number of quantum chemical descriptors (like Klopman atomic softness in terms of $E_n^{\ddag}\;and\;E_m^{\ddag}$, chemical hardness, global softness, electronegativity, chemical potential, electrophilicity index, heat of formation, total energy etc.) for 75 alkanes to predict their boiling point values. The 3D modeling, geometry optimization and semiempirical & DFT calculations of all the alkanes have been made with the help of CAChe software. The calculated quantum chemical descriptors have been correlated with observed boiling point by using multiple linear regression (MLR) analysis. The predicted values of boiling point are very close to the observed values. The values of correlation coefficient ($r^2$) and cross validation coefficient ($r_{cv}^2$) also indicates the generated QSPR models are valuable and the comparison of all the methods indicate that the DFT method is most reliable while the addition of Klopman atomic softness $E_n^{\ddag}$ in DFT method improves the result and provides best correlation.

THREE-DIMENSIONAL VERIFICATION OF INTRACRANIAL TARGET POINT DEVIATION USING MRI-BASED POLYMER-GEL DOSIMETRY FOR CONVENTIONAL AND FRACTIONATED STEREOTACTIC RADIOSURGERY

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.107-118
    • /
    • 2011
  • Conventional (SRS) and fractionated (FSRS) stereotactic radiosurgery necessarily require stringent overall target point accuracy and precision. We determine three-dimensional intracranial target point deviations (TPDs) in a whole treatment procedure using magnetic resonance image (MRI)-based polymer-gel dosimetry, and suggest a technique for overall system tests. TPDs were measured using a custom-made head phantom and gel dosimetry. We calculated TPDs using a treatment planning system. Then, we compared TPDs using mid bi-plane and three-dimensional volume methods with spherical and elliptical targets to determine their inherent analysis errors; finally, we analyzed regional TPDs using the latter method. Average and maximum additive errors for ellipses were 0.62 and 0.69 mm, respectively. Total displacements were 0.92 ${\pm}$ 0.25 and 0.77 ${\pm}$ 0.15 mm for virtual SRS and FSRS, respectively. Average TPDtotal at peripheral regions was greater than that at central regions for both. Overall system accuracy was similar to that reported previously. Our technique could be used as an overall system accuracy test that considers the real radiation field shape.