• 제목/요약/키워드: PLF

검색결과 50건 처리시간 0.023초

Radiographic Analysis of Instrumented Posterolateral Fusion Mass Using Mixture of Local Autologous Bone and b-TCP (PolyBone$^{(R)}$) in a Lumbar Spinal Fusion Surgery

  • Park, Jin-Hoon;Choi, Chung-Gon;Jeon, Sang-Ryong;Rhim, Seung-Chul;Kim, Chang-Jin;Roh, Sung-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권5호
    • /
    • pp.267-272
    • /
    • 2011
  • Objective : Although iliac crest autograft is the gold standard for lumbar fusion, the morbidity of donor site leads us to find an alternatives to replace autologous bone graft. Ceramic-based synthetic bone grafts such as hydroxyapatite (HA) and b-tricalcium phosphate (b-TCP) provide scaffolds similar to those of autologous bone, are plentiful and inexpensive, and are not associated with donor morbidity. The present report describes the use of Polybone$^{(R)}$ (Kyungwon Medical, Korea), a beta-tricalcium phosphate, for lumbar posterolateral fusion and assesses clinical and radiological efficacy as a graft material. Methods : This study retrospectively analyzed data from 32 patients (11 men, 21 women) who underwent posterolateral fusion (PLF) using PolyBone$^{(R)}$ from January to August, 2008. Back and leg pain were assessed using a Numeric Rating Scale (NRS), and clinical outcome was assessed using the Oswestry Disability Index (ODI). Serial radiological X-ray follow up were done at 1, 3, 6 12 month. A computed tomography (CT) scan was done in 12 month. Radiological fusion was assessed using simple anterior-posterior (AP) X-rays and computed tomography (CT). The changes of radiodensity of fusion mass showed on the X-ray image were analyzed into 4 stages to assess PLF status. Results : The mean NRS scores for leg pain and back pain decreased over 12 months postoperatively, from 8.0 to 1.0 and from 6.7 to 1.7, respectively. The mean ODI score also decreased from 60.5 to 17.7. X-rays and CT showed that 25 cases had stage IV fusion bridges at 12 months postoperatively (83.3% success). The radiodensity of fusion mass on X-ray AP image significantly changed at 1 and 6 months. Conclusion: The present results indicate that the use of a mixture of local autologous bone and PolyBone$^{(R)}$ results in fusion rates comparable to those using autologous bone and has the advantage of reduced morbidity. In addition, the graft radiodensity ratio significantly changed at postoperative 1 and 6 months, possibly reflecting the inflammatory response and stabilization.

KSLV-I 2단부 구조체 모드 시험 (Modal Test of the 2nd stage structure of KSLV-I)

  • 서상현;정호경;윤세현;박순홍;장영순
    • 항공우주기술
    • /
    • 제6권1호
    • /
    • pp.114-119
    • /
    • 2007
  • 본 연구는 KSLV-I 페이로드 페어링을 제외한 2단 구조부에 대한 모드시험 결과를 기술하고 있다. 2단부는 크게 위성 분리부, 탑재부, 킥모터 지지부, 킥모터로 구성되어 있다. 번지코드를 이용하여 자유경계단 조건을 모사하였고 가진은 대형 가진 망치를 사용하였다. 이러한 모드시험 결과를 통하여 모드변수를 추출할 수 있고, 2단부 구조체의 동특성을 파악할 수 있다. 시험 결과는 TDAS를 사용하여 분석하였고, 100Hz 이하의 모드변수 및 모드형상을 추출하였다.

  • PDF

Probabilistic Evaluation of Voltage Quality on Distribution System Containing Distributed Generation and Electric Vehicle Charging Load

  • CHEN, Wei;YAN, Hongqiang;PEI, Xiping
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1743-1753
    • /
    • 2017
  • Since there are multiple random variables in the probabilistic load flow (PLF) calculation of distribution system containing distributed generation (DG) and electric vehicle charging load (EVCL), a Monte Carlo method based on composite sampling method is put forward according to the existing simple random sampling Monte Carlo simulation method (SRS-MCSM) to perform probabilistic assessment analysis of voltage quality of distribution system containing DG and EVCL. This method considers not only the randomness of wind speed and light intensity as well as the uncertainty of basic load and EVCL, but also other stochastic disturbances, such as the failure rate of the transmission line. According to the different characteristics of random factors, different sampling methods are applied. Simulation results on IEEE9 bus system and IEEE34 bus system demonstrates the validity, accuracy, rapidity and practicability of the proposed method. In contrast to the SRS-MCSM, the proposed method is of higher computational efficiency and better simulation accuracy. The variation of nodal voltages for distribution system before and after connecting DG and EVCL is compared and analyzed, especially the voltage fluctuation of the grid-connected point of DG and EVCL.

광섬유를 이용한 상시감시 시스템용 음향방출센서의 개발 (Development of Fiber-Optic AE Sensor for On-Line Monitoring System)

  • 남재영;정재현;최재붕;김영진
    • 대한기계학회논문집A
    • /
    • 제24권12호
    • /
    • pp.2891-2898
    • /
    • 2000
  • The objective of this paper is to develop a fiber-optic acoustic emission(AE) sensor applicable to on-line monitoring systems which is suitable for long-distance signal transmission. An AE sensor was developed by use of a fiber-optic cantilever and an extrinsic Fabry-Perot interferometer(EEPI). The efficiency of signal processing was improved by driving the high frequency AE signals into the low frequency ones. In order to verify the developed sensor, the tensile and the pencil lead fracture(PLF) tests were performed including the experiment showing the Kaiser effect. Form tests, AE signals were successfully detected in the elastic-plastic deformation range, especially higher signals at the crack propagation. The developed sensor was expected to be used for an on-line monitoring of crack propagation in mechanical system.

Role of gas flow rate during etching of hard-mask layer to extreme ultra-violet resist in dual-frequency capacitively coupled plasmas

  • 권봉수;이정훈;이내응
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.132-132
    • /
    • 2010
  • In the nano-scale Si processing, patterning processes based on multilevel resist structures becoming more critical due to continuously decreasing resist thickness and feature size. In particular, highly selective etching of the first dielectric layer with resist patterns are great importance. In this work, process window for the infinitely high etch selectivity of silicon oxynitride (SiON) layers and silicon nitride (Si3N4) with EUV resist was investigated during etching of SiON/EUV resist and Si3N4/EUV resist in a CH2F2/N2/Ar dual-frequency superimposed capacitive coupled plasma (DFS-CCP) by varying the process parameters, such as the CH2F2 and N2 flow ratio and low-frequency source power (PLF). It was found that the CH2F2/N2 flow ratio was found to play a critical role in determining the process window for ultra high etch selectivity, due to the differences in change of the degree of polymerization on SiON, Si3N4, and EUV resist. Control of N2 flow ratio gave the possibility of obtaining the ultra high etch selectivity by keeping the steady-state hydrofluorocarbon layer thickness thin on the SiON and Si3N4 surface due to effective formation of HCN etch by-products and, in turn, in continuous SiON and Si3N4 etching, while the hydrofluorocarbon layer is deposited on the EUV resist surface.

  • PDF

Bayes estimation of entropy of exponential distribution based on multiply Type II censored competing risks data

  • Lee, Kyeongjun;Cho, Youngseuk
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권6호
    • /
    • pp.1573-1582
    • /
    • 2015
  • In lifetime data analysis, it is generally known that the lifetimes of test items may not be recorded exactly. There are also situations wherein the withdrawal of items prior to failure is prearranged in order to decrease the time or cost associated with experience. Moreover, it is generally known that more than one cause or risk factor may be present at the same time. Therefore, analysis of censored competing risks data are needed. In this article, we derive the Bayes estimators for the entropy function under the exponential distribution with an unknown scale parameter based on multiply Type II censored competing risks data. The Bayes estimators of entropy function for the exponential distribution with multiply Type II censored competing risks data under the squared error loss function (SELF), precautionary loss function (PLF) and DeGroot loss function (DLF) are provided. Lindley's approximate method is used to compute these estimators.We compare the proposed Bayes estimators in the sense of the mean squared error (MSE) for various multiply Type II censored competing risks data. Finally, a real data set has been analyzed for illustrative purposes.

하·폐수 처리시설 내 유입수 특성이 유기물 처리효율에 미치는 영향 (Effects of the Characteristics of Influent Wastewater on Removal Efficiencies for Organic Matters in Wastewater Treatment Plants)

  • 이태환;박민혜;이보미;허진;양희정
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.674-681
    • /
    • 2009
  • Characteristics of organic matters (OM) in wastewater and the removal efficiencies were investigated using the influent and the effluent samples collected from 21 wastewater treatment plants. The OM characteristics investigated included biodegradability, humic content, specific UV absorbance (SUVA), the distribution percentage of refractory OM (R-OM), and synchronous fluorescence spectra. The types of wastewater (sewage, livestock waste/night soils, industrial waste) were easily distinguished by comparing the synchronous fluorescence spectra of the influent wastewater. The prominent peak of protein-like fluorescence (PLF) was observed for livestock waste/night soils whereas sewage exhibited a unique fluorescence peak at a wavelength of 370 nm. Irrespective of the wastewater types, the distribution percentage of R-OM increased from the influent to the effluent. Livestock waste/night soils showed the highest removal efficiency among all the three types of wastewater. There was no statistical difference of the removal efficiency between a traditional activated sludge and biological advanced treatment processes. Removal efficiency based on dissolved organic carbon DOC presented good correlations with the distribution percentage of R-OM and fulvic-like fluorescence (FLF) of the influent. The prediction for DOC removal efficiency was improved by using multiple regression analyses based on some selected OM characteristics and mixed liquid suspended solid (MLSS).

Concurrent Chemoradiotherapy Versus Radiotherapy Alone for Locoregionally Advanced Nasopharyngeal Carcinoma

  • Yu, Hong-Sheng;Wang, Xin;Song, Ai-Qin;Liu, Ning;Zhang, Wei;Yu, Li
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권8호
    • /
    • pp.3961-3965
    • /
    • 2012
  • Objective: To compare the clinical effects of concurrent radiochemotherapy with those of radiotherapy in treating locally advanced nasopharyngeal carcinoma (Stage III~IVa). Methods: A total of 95 patients suffering from nasopharyngeal carcinoma (Stage III~IVa) were divided into two groups: concurrent radiochemotherapy (Group CCRT, n=49) and radiotherapy (Group RT, n=46). The two groups were both delivered conventional fractionated radiotherapy, while Group CCRT also received three cycles of PF (DDP+5-Fu) or PLF (DDP+5-Fu+CF) chemotherapy. Results: The complete remission rate and total remission rate of Group CCRT were higher than those of Group RT ($X^2$=4.72~7.19, P<0.05). The one-year overall survival (OS) rate calculated by the life table method, was also higher than that of Group RT ($X^2$=4.24, P<0.05) as well as the 3-year OS rate, nasopharyngeal control rate and cervical lymph nodes' control rate ($X^2$=4.28~4.40, P<0.05). In addition, the 5-year OS and metastasis-free rates of Group CCRT were higher than those of Group RT and the differences were of statistical importance ($X^2$=3.96~8.26, P<0.05). However, acute toxicity was also obviously higher, the difference in gastrointestinal reactions being statistically significant ($X^2$=11.70, P<0.05). Conclusion: This study demonstrated that concurrent radiochemotherapy could improve the remission rate, overall survival rate and locally control rate. The toxicity of concurrent radiochemotherapy could be tolerated by the patients.

UHF RFID 시스템을 위한 Polarization selective 안테나 연구 (UA Study on the Polarization Selective Antenna for UHF RFID System)

  • 이사원;송우영
    • 한국컴퓨터정보학회논문지
    • /
    • 제15권7호
    • /
    • pp.67-74
    • /
    • 2010
  • 본 논문은 UHF RFID 시스템을 위해 편파를 선택할 수 있는 리더 안테나를 설계 및 구현하였다. 제안된 리더 안테나는 두 개의 급전부를 가지는 마이크로 스트립 패치 안테나와 두 개의 SPDT 스위치와 하나의 SP4T 스위치와 3dB hybrid coupler로 구성되어 있다. 각각의 스위치 전압을 조절하여 수직 방향의 선형 편파와 수평 방향의 선형 편파, 좌수 원형 편파와 우수 원형 편파를 선택할 수 있다. 제안된 안테나는 902MHz~928MHz 대역에서 VSWR 2:1 기준으로 UHF RFID 주파수 대역인 902MHz~928MHz를 만족한다. 안테나의 최고이득은 X-Y Plane을 기준으로 선형 편파가 선택되어질 때 7.71dBi, 7.55dBi 로 측정되었고 원형 편파가 선택되어질 때 7.31dBic, 7.81dBic 로 측정되었다. 또한 원형 편파(LHCP, RHCP)가 선택 되어질 때 축비는 각각 2.01~2.83dB, 2.02~2.60dB로 측정되었고 이는 3dB 이하의 축비를 만족한다.

영상분석기법을 활용한 사육밀도에 따른 급이·급수 및 휴식공간별 육계의 행동특성 분석 (Analysis of Behavioral Characteristics of Broilers by Feeding, Drinking, and Resting Spaces according to Stocking Density using Image Analysis Technique)

  • 김현수;강환구;강보석;김찬호
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.558-569
    • /
    • 2020
  • 본 연구는 국내 육계농가의 사육규모 대형화에 따라 정밀축산(PLF)의 관점에서 ICT기반 영상분석기법을 활용하여 사육밀도에 따른 육계의 영역별 머무는 빈도(%)에 대해 평가하고, 일령별 육계의 정상적인 행동패턴을 이해하고자 수행하였다. 경기도 소재 육계농장 내 설치된 시험계사(3.3×2.7 m)에서 Ross308 육계를 공시축으로 이용하였다. 사육 밀도는 각각 9.5 수/㎡ (n=85), 19 수/㎡ (n=170)로 하였으며, 탑뷰(top view) 카메라를 이용해 급이·급수 및 휴식공간 영역별 머무는 빈도(%)를 모니터링 하였다. 사육밀도에 따라 개체 식별된 육계 3수에 대해 일령별(12, 16, 22, 27, 및 29일)로 6시간씩 영상이미지 데이터를 획득하였다. 수집된 영상데이터는 물체 추적(object tracking) 기법으로 초당 30프레임으로 약 64만장의 프레임을 연결하여 누적 이동경로를 기록하여 영역별 머무는 빈도(%)를 수치화하였다. 각 사육밀도에서 영역별 머무는 빈도(%)는 휴식공간, 급이영역, 급수영역 순으로 유의적인 차이를 나타내었다(p<0.001). 사육밀도(9.5 수/㎡)에서는 57.9, 24.2, 17.9%으로 나타났으며, 사육밀도(19 수/㎡)에서는 73.2, 16.8, 10.0%로 나타났다. 결과적으로 ICT기반 영상분석기법을 활용해 육계의 스트레스를 최소화하는 방법으로 사육밀도에 따른 육계의 영역별 머무는 빈도(%)를 평가할 수 있으며, 향후 본 연구결과는 실시간 모니터링을 통한 ICT기반 사양관리 시스템을 개발하는데 기초자료로 활용될 수 있을 것으로 기대된다.