• Title/Summary/Keyword: PLC modem

Search Result 70, Processing Time 0.023 seconds

A Development of Module Operating on Standby-power Reduction for PLC Control Modem (제어용 PLC 모뎀을 위한 대기전력 절감 모듈 개발)

  • Kim, Kl-Hyun;Kim, Ji-Hong;Kim, Nam-Kyun;Kim, Sang-Cheol;Seo, Kil-Soo;Kim, Eun-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.296-299
    • /
    • 2004
  • This paper introduces a supplementary module reducing tile standby-power of Power Line Communication(PLC) modem, one of the network equipments that take up much of tile stand-by power. This supplementary module consists of three parts, such as a compare part, a control part, and a switch part. This supplementary module controls the power going from the power supply element into PLC modem, which brings about the effect of standby-power reduction. It is assured that over 30% standby-power reduction is estimated when we applied this module to a low-speedy PLC control modem.

  • PDF

A Study for the Measurement Method of Electromagnetic Field Strength of Power Line Communications Modem (전력선통신모뎀의 전자계강도 측정방법 연구)

  • Jang Dong-Won
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.162-165
    • /
    • 2006
  • This paper describes a measurement method for electromagnetic field strength of power-line communications(PLC) modem. First it outlines the technology used in PLC modems, and the technical regulation being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this protection. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC modem mean that there is no consensus as yet as to how PLC modem components can be made compliant with EMC requirements globally. It is concluded that there is a measurement method according to CISPR standards which satisfy requirements in domestic regulation.

  • PDF

A Development of Module Operating on Standby-power Reduction for Low-speedy PLC Modem (저속 PLC 모뎀을 위한 대기전력 절감 모듈 개발)

  • Kim Ki-Hyun;Kim Ji-Hong;Kim Nam-Kyun;Kim Sang-Cheol;Seo Kil-Soo;Kim Eun-Dong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1537-1539
    • /
    • 2004
  • This paper introduces a supplementary module reducing the standby-power of Power Line Communication(PLC) modem, one of the network equipments that take up much of the stand-by power. This supplementary module consists of three parts, such as a compare part, a control part, and a switch part. This supplementary module controls the power going from the power supply element into PLC modem, which brings about the effect of standby-power reduction. It is assured that over $30\%$ standby-power reduction is estimated when we applied this module to a low-speedy PLC control modem.

  • PDF

Design and Implementation of the Dual-Mode Type Reliable PLC Modem Chip (듀얼 모드형 고신뢰 PLC 모뎀 칩 설계 및 구현)

  • Lee, Won-Tae;Choi, Sung-Soo;Yun, Sung-Ha;Rhee, Young-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.488-493
    • /
    • 2008
  • This paper represents a dual-mode type transmission technique for a high reliable narrow-band power line communication(PLC) modem, and its design and implementation of a system-on-chip(SoC). The proposed transmission technique is based on a Chirp modulation for the purpose of overcoming time variations of power line channel environments in the narrow-bandwidth of the frequency range of 95-145.5 kHz. The designed modem is fabricated utilizing a mixed 0.18 ${\mu}m$ CMOS technology. Especially, according to the power line channel environments the data transmission rate can be selectively changed into 2.5 kbps and 480 bps. The total hardware complexity of the implemented chip is about 50,000 gates, the power consumption is about 26mW, and the operating frequency is up to 5.12 MHz.

Development of Telemetering and Control system using PLC and Web (전력선통신과 인터넷을 이용한 원격제어 및 검침구현)

  • 최원호;박종연
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.4
    • /
    • pp.282-290
    • /
    • 2003
  • AMR(Automatic Meter Reading) and RC(Remote Control) System have been researched from former several decade for a various power rate system, a efficient power service and rising of personal expenses, etc. But the existing AMR and RC System have disadvantage which are complex and high cost to install an individual communication network of electricity company. This paper proposed a new type of AMR and RC System using PLC with Web. and made components for proposal system. Most customer who live in apartment have an internet cable in the Republic of Korea. Therefore there is no more installation component for communication in proposal system at the apartment, except Web server system and PLC modem. so we made the PLC modem the digital watt-hour meter with a build in PLC modem and the software on server computer for establishing the proposal system.

A Study on the development of Heating Facility Control and Remote Control System using Power Line Communication (PLC) (전력선 통신(PLC)을 이용한 난방기기 제어 및 원격제어 시스템의 개발에 관한 연구)

  • Kim, Yong-Tae;Shin, Kwan-Woo;Lee, Youn-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.65-67
    • /
    • 2001
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter. The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance selective possibility of frequency property. This study designed the boiler temperature control system by unit using the modem designed on the basis of technology used for PLC modem, and designed remote control system using internet. After conducting experiments with those two systems, it was possible to control stably. By commercializing this product, we can avoid unnecessary heating of separate temperature control unit, and save the cost according1y, and it is possible to control on a remote site using internet in a more convenient way.

  • PDF

Implementation of PLC-Based Multi-modem for Process Automation of Non-destructive Inspection (비파괴검사 공정자동화를 위한 전력선통신 기반 복합통신장치의 구현)

  • Jung, Jun Hwan;Jun, Ho Ik;Kim, Hyun-Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.822-828
    • /
    • 2013
  • In this paper, a multi-modem for process automation of non-destructive inspection (NDI) which possibly generates various kinds of data is implemented and verified. Here, a variety of data such as control signals, text data, image data generated by inspection devices, sensors, computers are transmitted to the multi-modem via serial, Ethernet, and coaxial cable. We exploit a communication network in which powerlines are used as backbone transmission media. Thus, the implemented multi-modem has various ports and corresponding interfaces for data transmission. As a result of practical experiments, the multi-modem maintains almost constant data rate with little waveform distortion. In addition, the experiments confirm that the modem operates normally under extreme variation of temperature. It is, therefore, considered that the multi-modem can contribute significantly to implement powerline communication (PLC)-based process automation for NDI in which various kinds of data are practically generated.

Broadband Impedance Matching Circuit Design for PLC Coupler Using Tchebycheff Equalizer

  • Kim, Gi-Rae;Tangyao, Xie
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.113-118
    • /
    • 2009
  • This paper is about design broadband impedance matching circuit for Coupler to improve power transfer efficiency in the power line communication (PLC) system. The Tchebycheff gain function algorithm is represented to design broadband matching circuit. A practical PLC Coupler impedance matching circuit is designed, and the characteristics for S11 and S21 of PLC coupler are enhanced comparing with unmatched one. This is done by maximizing the power transfer gain from modem to the load.

Implementation of the Man-made Disaster Prevention and Localization Information Monitoring System based on PLC (PLC 기반 인적 재난 방지 및 위치 정보 모니터링 시스템 구현)

  • Yoon, Seon-Tae;Park, Ki-Won;Ko, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.3
    • /
    • pp.384-390
    • /
    • 2010
  • Since many accidents have been constantly occurring in the workplace, requirements of Industrial Safety Management have also been increasing. In order to meet the needs and prevent the problems in advance, we designed wireless sensor network system based on PLC. This system is set with amain node including PLC Modem and Zigbee in the every workplace and each wireless sensor node is attached to every worker in the workplace. The main node is supposed to transmit and receive sensor data, and the data which is from a wireless sensor node to the main node is delivered to monitoring PC through PLC. In this paper, it is expected that, by perceiving the realtime situation of the work place through this system, we could prevent the problems in advance and reduce damages by accidents.

Performance Test and Analysis of Master-Slave Based PLC Modem in General Building (일반 환경에서 마스터-슬레이브 기반 전력선 통신 모뎀의 성능 시험 및 분석)

  • Hwang Min-Tae;Ha Hyun-Seok;Lee Jae-Jo
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.5
    • /
    • pp.660-669
    • /
    • 2005
  • In this paper 10Mbps master-slave based PLC modems are tested for measuring and analyzing both network and application level performances in the general buildings. The devices under test consist of one master PLC modem and three slave modems. The selected parameters for inspecting the performances are throughput, latency and frame loss rate from the RFC 2544, and one-to-many and many-to-one throughput from the RFC 2285. The results of the performance test show that the PLC modems have Performed better in data transmission when the frame size is increased and the transmission speed is decreased. It is expected that these results will be useful to analyze the effect of noise sources when compared to the performance test under the noiseless environments.

  • PDF