• Title/Summary/Keyword: PLC communication

Search Result 441, Processing Time 0.031 seconds

Performance Characteristics of Broadband PLC at Out-door Field Test-bed (저압 인입선에서의 고속 전력선통신 특성 분석)

  • Park Byung-Seok;Yoo Dong-Hee;Hyun Duck-Hwa;Choi Young-Lim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.264-273
    • /
    • 2005
  • Broadband power line communications have been receiving tremendous interest In recent years because this technology enables utilities to deploy a communication network over existing power line infrastructures. Despite the enormous potential, there is some skepticism about the technology and its commercial viability. In this paper, we investigate the performance characteristic of PLC through field test carried out in actual households. Also it addresses major field deployment aspects, such as range, coverage, the number of node for operation and maintenance.

Reconfigurable Optical Add-Drop Multiplexer Using a Polymer Integrated Photonic Lightwave Circuit

  • Shin, Jang-Uk;Han, Young-Tak;Han, Sang-Pil;Park, Sang-Ho;Baek, Yong-Soon;Noh, Young-Ouk;Park, Kang-Hee
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.770-777
    • /
    • 2009
  • We have developed a fully functional reconfigurable optical add-drop multiplexer (ROADM) switch module using a polymer integrated photonic lightwave circuit technology. The polymer variable optical attenuator (VOA) array and digital optical switch array are integrated into one polymer PLC chip and packaged to form a 10-channel VOA integrated optical switch module. Four of these optical switch modules are used in the ROADM switch module to execute 40-channel switching and power equalization. As a wavelength division multiplexer (WDM) filter device, two C-band 40-channel athermal arrayed waveguide grating WDMs are used in the ROADM module. Optical power monitoring of each channel is carried out using a 5% tap PD. A controller and firmware having the functions of a 40-channel switch and VOA control, optical power monitoring, as well as TEC temperature control, and data communication interfaces are also developed in this study.

A Study on the Optical Alignment of Multi-Axis Ultra Precision Stage (극초정밀 스테이지의 광소자 정렬에 관한 연구)

  • Jeong Sanghwa;Cha Kyoungrae;Kim Hyunuk;Choi Sukbong;Kim Gwangho;Park Juneho
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.203-208
    • /
    • 2005
  • In recent years, as the demands of VBNS and VDSL increase, the development of kernel parts of optical communication such as PLC(Planar Light Circuit), Coupler, and WDM elements increases. The alignment and the attachment technology are very important in the fabrication of optical elements. In this paper, the optical alignment characteristics of multi-axis ultra precision stage were studied. The alignment algorithms were studied for applying to the ultra precision multi-axis stage. The alignment algorithm is comprised of field search and peak search algorithms. The contour of optical power signals can be obtained by field search and the precise coordinate can be found out by peak search. Two kinds of alignments, such as 1 ch. input vs. 1 ch. output optical stack, and 1 ch. input vs. 8 ch. output PLC stacks were performed for investigating the alignment characteristics.

  • PDF

A Study on the Interference of HF Radiocommunication by the PLC (전력선통신이 단파대 해상이동통신에 미치는 영향에 관한 연구)

  • Kim, Jeong-Nyun;Jeong, Seok-Yeong;Jo, Hag-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.173-176
    • /
    • 2005
  • 본 연구는 2005. 7. 1 시행 공포된 전파법 시행령 개정안 내용 중 전력선통신설비의 주파수 대역이 9kHz${\sim}$450kHz에서 그 상한선 범위가 30MHz까지 확대 시행됨과 관련하여 전력선통신설비가 단파대 무선통신에 혼신을 야기할 수 있음에 따라 그 영향여부를 평가하는 방법을 제시하고 향후 전력선통신설비를 운용함에 있어서 단파대 무선통신에 영향을 회피하기 위한 대책방안을 제안하는데 있다. 전력선통신의 운용주파수 확대와 관련하여 정보통신부 전파연구소에서 전력선통신이 단파대 무선통신의 혼신여부에 대하여 측정 관찰해 왔으며 그 간섭정도를 판단하기 위해 노력해 왔다. 본 연구에서는 전파수신기, 신호발생기 및 SINAD(Signal to Noise and Distortion) Meter를 사용한 측정방법을 제시하고 있으며 이는 무선(RF : Radio Frequency) 환경에 적합한 측정방법으로 기존의 EMC(electromagnetic compatibility) 환경에 의한 한계를 극복할 수 있다. 또한, 본 연구에서는 전력선통신설비가 단파대 해상이동통신에 영향을 최소화하기 위하여 보호구역을 설정 또는 해당 주파수에 대하여 운용금지하는 방안을 제시함으로써 무선통신환경을 보호하는데 그 목적이 있다.

  • PDF

Development of a Home Gateway na a Management Server for Home Network Environments (홈 네트워크 환경에서 홈 게이트웨이와 관리 서버 개발)

  • Kwon Jinhyuck;Jung Jaeyun;Kim Hagbae
    • The KIPS Transactions:PartC
    • /
    • v.12C no.2 s.98
    • /
    • pp.261-266
    • /
    • 2005
  • This paper proposes two systems. One is a Home Gateway(HG) which efficiently connects and controls digital appliances in the home network environments. The other is a Management Server(MS) that overcomes the physical limitation of the HG. The HG supports networking modules(TCP/IP for Ethernet, ADSL), home networking functions(HomePNA, IEEE1394 PLC) and telecommunication system(PSTN/SLT, VoIP, Video Communication). The HG is expected to be a core device for the integrated digital home environments. The MS is a dedicated server which manages and controls individual HG, home appliances and HA devices implemented at an area.

Implementation of Indoor Localization System

  • Ryu, Dong-Wan;Kim, Sun-Hyung;Jeong, Dong-Gyu
    • International journal of advanced smart convergence
    • /
    • v.8 no.3
    • /
    • pp.54-60
    • /
    • 2019
  • In this paper, a localization system for indoor objects is proposed. The proposed system consists of Beacons, LED Cells, Main Cell Controller (MCC), and Display. A Beacon is attached at each indoor object, and each LED cell has Beacon Scanner and VLC Transmitter. The Visual Light Communications (VLC) and Power Line Communications (PLC) methods are used to communicate the signals for localization of indoor objects. And the proposed system is designed, and implemented as a prototype. To certify that our propose d system can exactly localize a given indoor object, we take test for the implemented system as a p rototype. Here the location of the given indoor object is known. Test is done in two ways. The first is to check the operation of the detail of the system, and the second is the position recognition of i ndoor object. The second is the test of the implemented system to correctly detect the location of the indoor object with Beacon, while the object with Beacon is moved from location C to A. The experimental result shows that the system is exactly detect the moving locations. The system has the advantages of using previously installed power lines, and it does not need to use LAN lines or optical cables. The proposed system is usefully applied to indoor object localization area.

Applying the IoT platform and green wave theory to control intelligent traffic lights system for urban areas in Vietnam

  • Phan, Cao Tho;Pham, Duy Duong;Tran, Hoang Vu;Tran, Trung Viet;Huu, Phat Nguyen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.1
    • /
    • pp.34-52
    • /
    • 2019
  • This paper proposes an intelligent system performing an application with assistance of an Internet of Things (IoT) platform to control a traffic lights system. In our proposed systems, the traffic lights can be remotely controlled through the Internet. Based on IoT platform, the traffic conditions at different intersections of roads are collected and the traffic lights are controlled in a central manner. For the software part, the algorithm is designed based on the green wave theory to maximize the green bandwidth of arterial roads while addressing a challenging issue: the rapid changes of parameters including cycle time, splits, offset, non-fixed vehicles' velocities and traffic flow along arterial roads. The issue typically happens at some areas where the transportation system is not well organized like in Vietnam. For the hardware part, PLC S7-1200 are placed at the intersections for two purposes: to control traffic lights and to collect the parameters and transmit to a host machine at the operation center. For the communication part, the TCP/IP protocol can be done using a Profinet port embedded in the PLC. Some graphical user interface captures are also presented to illustrate the operation of our proposed system.

A Study on the Motion Mechanism of Multi-Axis Ultra Precision Stage for Optical Element Alignment (광소자 정렬용 극초정밀 다축 스테이지의 구동 메커니즘에 관한 연구)

  • Jeong Sang-hwa;Kim Gwang-ho;Cha Kyoung-rae;Lee Kyoung-hyoung;Song Suk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.1
    • /
    • pp.8-16
    • /
    • 2006
  • The communication through optical fiber is taking an important role of the expansion of communication network with excellent transmitting rate and quality. As the optical communication is introduced to the backbone network at first and becomes a general communication method of network, the demand of kernel parts of optical communication such as PLC(Planar Light Circuit), Coupler, and WDM(Wavelength Division Multiplexing) element increases. The alignment and the attachment technology are very important in the fabrication of optical elements. In this paper, the driving mechanism of ultra precision stage is studied with the aim of optimal design of stage. The travel and the resolution of stage are investigated. The hysteresis of the stage is generated because of PZT actuator. The hysteresis and the inverse hysteresis are modeled in X, Y, and Z-axis motion. The input data of desired displacement of the stage according to input voltage is obtained from the inverse hysteresis equation. In the result of experiments with the input data, the errors due to hysteresis are well compensated.

Analysis of Unaspirated sound for Korean (한국어의 경음에 대한 분석)

  • Lim Soo-Ho;Kim Joo-Gon;Kim Bum-Guk;Jung Ho-Youl;Chung Hyun-Yeol
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.41-44
    • /
    • 2004
  • 본 논문에서는 한국어에만 나타나는 경음에 대하여 음운학적, 음향학적 특성을 고찰하고 이를 기반으로 음성인식 실험을 수행한 후 그 결과를 분석하였다. 음성인식 실험을 위하여 입력 음성을 48개의 유사음소단위 (PLU; Phoneme Likely Unit)로 레이블링을 한 후 각각의 음소군에 대하여 LPC (Liner Predictive Coding) 분해능을 증가시키면서 음소인식 및 단어인식 실험을 수행하였다. 그 결과, 음소 인식 실험에서 경음군의 인식률이 가장 낮게 나타나 경음에 대한 분석이 보다 많이 필요함을 알 수 있었다. 또한 PLC의 분해 차원이 23차 일 때 경음과 전체 음소 인식률이 각각 $34.11\%,\;46.1\%$로 나타나 가장 양호함을 알 수 있었으며 단어인식 실험에서도 LPC 23차와 25차 일 때 $81.68\%,\;81.87\%$로 인식률이 가장 좋음을 알 수 있었다. 이상의 실험 결과에서 한국어의 경음은 전체 시스템의 인식 성능과 밀접한 관계가 있음을 알 수 있었다.

  • PDF

Power Line Communication-based Heated Glass Temperature Control System (전력선통신을 이용한 선박 및 건축용 발열유리 온도제어 시스템)

  • Lee, Su-Hyeong;Kim, In-Dong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.105-114
    • /
    • 2015
  • Heated glasses are widely used to prevent surface condensation and freezing in ship and building windows. This study proposes a heated glass temperature control system composed of power and control circuits to control the temperature of heated glasses. The proposed temperature control system adopts a digital controller instead of a conventional analog controller. Thus, the proposed system has better characteristics, such as precise setup and control of glass temperature, setup and control of output power, and control mode change between ON/OFF and phase controls. The system can also implement multi-functional control algorithms. The control characteristics are not dependent upon external disturbances, such as ambient temperature and electrical noises. Furthermore, the proposed temperature control system utilizes the power line communication (PLC) method to control the number of heated glasses without any extra communication lines. The system proposes a new communication protocol with strong immunity to electrical switching noises. A new sensorless algorithm is used to detect the temperature of the heated glass. This study presents the design guidelines in detail and its effectiveness are confirmed by implementing a 4-kw prototype temperature control system.