• Title/Summary/Keyword: PLC System

Search Result 749, Processing Time 0.028 seconds

Advanced Droop Control Scheme in Multi-terminal DC Transmission Systems

  • Che, Yanbo;Zhou, Jinhuan;Li, Wenxun;Zhu, Jiebei;Hong, Chao
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1060-1068
    • /
    • 2018
  • Droop control schemes have been widely employed in the control strategies for Multi-Terminal Direct Current (MTDC) system for its high reliability. Under the conventional DC voltage-active power droop control, the droop slope applies a proportional relationship between DC voltage error and active power error for power sharing. Due to the existence of DC network impedance and renewable resource fluctuation, there is inevitably a DC voltage deviation from the droop characteristic, which in turn results in inaccurate control of converter's power. To tackle this issue, a piecewise droop control with DC voltage dead band or active power dead band is implemented into controller design. Besides, an advanced droop control scheme with versatile function is proposed, which enables the converter to regulate DC voltage and AC voltage, control active and reactive power, get participated into frequency control, and feed passive network. The effectiveness of the proposed control method has been verified by simulation results.

A Design and Implementation of Combustor Control System (연소기 제어 시스템 설계 및 구현)

  • Chang, Jun-Hyup;Kim, Kun-Woo;Jeon, Chang-Ho;Keum, Tae-Hoon;Kim, Seung-Gon;Lee, Sang-Jun;Lee, Won-Joo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.06a
    • /
    • pp.127-128
    • /
    • 2011
  • 본 논문에서는 Flow 모니터링 및 제어, Graph 출력, Test, History 등의 기능을 제공하는 연소기 제어 시스템을 설계하고 구현한다. Flow 모니터링 및 제어 기능은 각 채널의 현재 유량을 표시하고, 제어할 수 있다. Graph 출력 기능은 현재 채널의 상태를 그래프로 나타낸다. Test는 현재 구성된 환경이 정상적으로 동작하는지 시험하는 기능을 제공하며, Setting은 각 채널의 채널명, Point set, Range, 허용오차를 설정한다. 그리고 History는 저장된 데이터를 읽어와 Error기록, 사용자에 의해 저장된 데이터, 24시간마다 자동 저장되는 데이터를 그래프로 표시해 준다. 본 논문에서 제안한 연소기 제어 시스템을 이용해서 실제 유량을 측정한 결과, 정확한 유량의 측정을 할 수 있었다.

  • PDF

Conceptual Design of Crew Support System Based on Wireless Sensor Network and Power Line Communication for Cruise Ship (전력선통신(Power Line Communication) 기반 센서네트워크를 이용한 크루즈선 승무원 지원 시스템 개념연구)

  • Kang, Hee-Jin;Lee, Dong-Kon;Park, Beom-Jin;Paik, Bu-Geun;Cho, Seong-Rak
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.6
    • /
    • pp.631-640
    • /
    • 2009
  • The highest priority of the cruise trip is the safety and comfort of its passengers. Though the cruise lines take every appropriate measure to ensure that their Passengers are safe and experience enjoyable vacations it is hard to fulfill all passenger's personnel requirement with limited number of crews. Generally, each passenger is issued an identification card which contains their digital photo and personal identification information on a magnetic strip that he or she must present when entering or leaving the ship. This technology allows the ship to know which Passengers and crew members are on board and which are not. However, this system has some limitations of functions and usage. To support each passenger as his or her personal liking, additional number of crews or some kind of new system is needed. In this paper, the crew support system based on sensor network using wireless and wired communication technologies was studied. To design the system, PLC(Power Line Communication) system and ZigBee based passenger location recognition, classification system has studied experimentally. By using this system, crews can serve passengers more closely and personally with less effort.

A Study on Vibration & Noise Reduction of Fast Back Feeding Device for Manufacturing Process (제조공정용 Fast Back 이송장치 진동·소음 저감에 관한 연구)

  • Han, Doo-Hee;Lee, Seung-Hun;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.642-648
    • /
    • 2019
  • This paper presents a fast back-type transfer device for snack food processing that uses the inertia of transferred material. A conventional conveying system is a drive system that uses a belt conveyor and mechanical crank, which generate noise and vibration and cause environmental pollution. Vibration and noise are reduced in the proposed fast back feeding device by using a counterweight. The crank drive unit was replaced with a linear servomotor, and an equilibrium device was designed to balance the force due to acceleration. This makes it is possible to adjust the forward and backward speed and acceleration through PLC control. A vibration damper device offsets the vibration force of the periodic shock form. The main cause of the vibration was identified through vibration analysis, and reduction measures were established. We verified the effectiveness of the vibration by making a prototype and performing about 10 vibration tests. Because no mechanical transducer is needed, energy loss, noise, and vibration do not occur, and the operating speed is not limited.

Development of the Dynamometer Control System for Medium Speed Diesel Engines

  • Choi, Sang-Gu;Ryu, Sang-Hun;Kim, Jeom-Goo;Park, Ho-Chol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.243-247
    • /
    • 2004
  • The dynamometers which had made in a long time ago could not control the input/output quantity of water minutely and was sensitive to a noise since it was controlled by an analog control method. Therefore, a fully digital controlled system was urgently required to be robust against various noises. In this paper, the new system which can control the amount of circulated water in dynamometer was developed. This system is consisted of an industrial digital type controller and a servo motor. The industrial PLC was used as a main controller for the developed system, and the actuator and servo motor were used to control the inlet and outlet valve independently. The torque signal of load cell was fed back to the main controller to regulate the diesel engines load. Generally, an input/output valve position of the old dynamometer was fixed with a proper situation for an engine output test and the torque was changed according to the time interval. However, the torque value for the dynamometer could not be constantly kept because of the variation of the input water flow and fluid characteristic. Therefore, the automatic control of an inlet and outlet valve should be performed to keep the constant torque. So, the PID control method was applied to solve this problem. Also, the development of a web-based remote control system was described in this paper. This software will give us the convenience of operation, the more efficient operations, and the reduced operator workload for operation of the dynamometer. The application results of the system have been verified at actual diesel engine field.

  • PDF

Design and Development of Monitoring System for Subway Station based on USN (USN 기반의 지하역사 모니터링 시스템의 설계 및 개발)

  • Lee, Seok-Cheol;Jeong, Shin-Il;Kim, Chang-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.11
    • /
    • pp.1629-1639
    • /
    • 2009
  • This paper describes the environmental monitoring system for supporting comfortable subways based on USN. Our development system includes the sensor field based on integrated sensor, monitoring system for supporting the local and remote monitoring and middle-ware performs the collecting, analyzing, and storing the data. In this paper, we installed the temperature, humidity, micro-dust sensor and water-level sensor for supporting the rail-roads and make up the integrated sensor enables to reuse the analog device from 4~20mA output with connection of wireless sensor device. Middleware includes the modules of collecting, analysis, and storing the data and monitoring system supports the local for administrator and remote monitoring for citizen services based on web. The middleware and monitoring in this paper is comprised of some components can reuse and support the change of application and sensors. Our development system supports the mobility of sensor devices and distributes system. Data collection and management function supported by middleware will use assessment.

  • PDF

A Study on Development of Industrial Engine Monitoring System Using Smart Phone Application (스마트폰 앱을 이용한 산업용 엔진의 모니터링 시스템 개발에 관한 연구)

  • Jeong, C.S.;Kim, Y.S.;Jeong, Y.M.;Kho, J.H.;Jeong, K.S.;Lee, H.S.;Yang, S.Y.
    • Journal of Drive and Control
    • /
    • v.10 no.2
    • /
    • pp.7-12
    • /
    • 2013
  • In this study, a wire/wireless communication system transmitting the operation data of engine from the ER (Engine Room) to the engine controller of ECR(Engine Control Room) has been developed through the communication of ISM(Industrial Science Medical) Band for the test operation environment improvement of medium speed engine. This wire/wireless communication system is composed of the RTU (Remote Terminal Unit) gathering and transmitting engine data as well as the MCU (Master Control Unit) receiving engine status information from the RTU to be sent to the engine controller (PLC). Through this study, a trial product of RTU and MCU has been manufactured. A test bench that has made temperature, pressure and pick-up sensor into a module for the local test of prototype was produced a test bench. In addition, at the same time save the data to a Web server and the smart phone real-time monitoring system has been developed using Wi-Fi communications. The ultimate objective of this study is to develop a wireless smart phone monitoring system of engine for the operator of engine to be able to monitor and control engine status even from the outside of engine room and control room based on this study.

The Verification Test of Launch Control System Algorithms Using Automated Verification System (자동화 검증시스템을 이용한 발사관제시스템 알고리즘 검증시험)

  • An, Jae-Chel;Moon, Kyung-Rok;Oh, Il-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.3
    • /
    • pp.127-137
    • /
    • 2021
  • The launch complex(LC) is composed of various facilities. The launch control system that operates remotely those of LC spends much time and labor for developing and verifying its control algorithms. The verification of algorithms is performed by the software developer entering simulated state values based on the test procedure and checking the output result according to the algorithm flow. These verification processes should be performed repeatedly, thus the human errors are easily occurred. In this paper, an efficient automated verification method with a script test procedure is proposed to minimize human errors and shorten the verification duration. We also present the results of the algorithm verification tests for the cases of the compressed gases supply system and the electro pneumatic panel system of LC.

A Development Of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power (전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발)

  • Yoon, Jae-Shik;Wee, Jung-Chul;Song, Yong-Jae;Park, Chung-Ha;Kim, Jae-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1964_1965
    • /
    • 2009
  • 최근 경제성장과 함께 생활수준의 향상으로 인하여 홈 게이트웨이는 디지털 홈 가전기기에 초고속 통신망 접속 기능을 제공하며 각종 기기들을 하나로 네트워크화 하는 중요한 기능을 담당하게 된다. 전력선 통신은 전력선을 매체로 하기 때문에 신규선로의 포설 없이 가전기기 및 정보화 서비스 모뎀들의 네트워크화에 용이할 뿐만 아니라 커버리지 확장에도 뛰어나서 디지털 가전, 원격검침, 전력설비 감시제어, 국가 재난 감시 시스템 등의 기본 통신 방식으로 가장 유력한 기술로써 디지털 가전을 포함한 유비쿼터스 전기설비 네트워크 구성에서 필수적 기술로 채택되고 있기 때문에 지능형 홈 네트워크, 전력IT 부가 서비스, 설비감시 네트워크, 유비쿼터스 네트워크 관련 기술에 대한 파급 효과가 매우 크며, 디지털 가전의 기본 통신 방식으로 가장 유력한 기술로써 디지털 가전 구성에서 필수적 기술로 채택되고 있다. 본 연구에서는 전력선통신모뎀을 이용하여 가전기기의 전력 소비를 감지할 수 있는 센서를 내장한 전력선 통신기반의 전력 감시 모듈을 개발하여 실시간 원격 모니터링을 통해 소비전력 패턴을 작성한다. 그리고 전력감시 모듈에 연결된 가전기기의 소비전력 패턴 분석을 통해 전력소비 이상 유무를 감지할 수 있는 알고리즘을 개발, 탑재하여 이상 유무를 판단하고 전력소비가 급증할 시 자동으로 전력을 차단하여 화재나 누전의 위험을 방지한다. 이에 본 연구는 전력감시 및 이상전력 차단기능을 갖는 저전력 전력선통신 모뎀 개발에 관한 것이다.

  • PDF

The Design and Implementation of AMI System Using Binary CDMA (Binary CDMA 기반의 AMI 시스템 설계 및 구현)

  • Joe, In-Whee;Jeong, Jong-Yuel
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8C
    • /
    • pp.663-669
    • /
    • 2012
  • To solve the energy problem and finding new growth engines, interest for the smart grid is increasing and related technologies are making great efforts to secure in the world. AMI (Advanced Metering Infrastructure) Among them is the first to be constructed and getting attention as a key component of smart grid. A fusion of various technologies in technology development and demonstration is underway on Jeju Island Smart Grid Demonstration Complex in Korea, and focusing on broadband power line communication technology infrastructure is actively underway in Korea Electric Power Corporation. AMI system using power line communication technology without building a separate communication lines are available for power supply lines, but communication is impossible in occurs because admission to the power company or the ideal infrastructure for communication is not considered. In this paper, we analyze the requirements to build AMI system using Binary CDMA and powerline communications technology, and design the basic communication protocol based on Binary CDMA, implement network management and relay feature. By doing so, ways to apply Ad-hoc Binary CDMA indigenous technology to the AMI system were derived, and could build a system to make use of Wired (PLC) and wireless (Binary CDMA) simultaneously.