• 제목/요약/키워드: PLC Communication

검색결과 441건 처리시간 0.03초

Cnet 프로토콜을 이용한 PLC간의 다중무선통신에 관한 연구 (A Study on the Multi-wireless Communication Using Cnet Protocol for PLC)

  • 류길수;이후락;정경열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권4호
    • /
    • pp.384-390
    • /
    • 2005
  • This paper addresses the design and implementation of a wireless network. proposed as a cost-effective support platform for PLCs. With this network. one or more supervising stations may access remote equipment like PLCs. An applicable communication methods are described and we applied efficient method among them to PLCs communication. The paper specifies these requirements and indicates methods to fulfill them. Also. it provides to the model of operation, and focuses on the implementation approach. The hardware and software design is described together with a number of critical points related to wireless communication on the Cnet. Furthermore, a discussion on system expandability and performance is tackled and some observations are stated. The main conclusion is, that the proposed method can feature good performance under normal operating conditions.

Development of Monitoring and Control System of Utility-Pipe Conduit (Power Tunnel) using PLC

  • Lee, Tae-Young;Park, Byung-Seok;Ju, Seong-Ho;You, Dong-Hee;Lim, Yong-Hoon;Song, Seok-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.116-119
    • /
    • 2004
  • The existing monitoring and control systems of utility-pipe conduit (power tunnel, cable tunnel etc) have established communication lines using optical fiber, leaky coaxial cable (LCX), and several kinds of control cable. Due to the properties of the used media, the cost of equipment is considerably high and the maintenance of the system is difficult. Also, the term of carrying out is long so that the extension of the system is in difficulty. Now it is desirable to adopt Power Line Communication (hereinafter, PLC) technology in the monitoring and control systems and use the existing low-voltage power-line for lamplight as communication line. This will lead the reduction of the construction cost and the easy maintenance of the system. In this paper, we research the characteristics of PLC in conduit, design and manufacture the field test system, and analyze the performance of the system by field test. Then, we introduce the reliable monitoring and control system of utility-pipe conduit using PLC.

  • PDF

전력선통신과 인터넷을 이용한 원격제어 및 검침구현 (Development of Telemetering and Control system using PLC and Web)

  • 최원호;박종연
    • 전자공학회논문지SC
    • /
    • 제40권4호
    • /
    • pp.282-290
    • /
    • 2003
  • 전력선 통신을 이용한 기존의 원격검침 시스템은 설치가 복잡하고 비용이 많이 든다. 현대 국내의 대부분의 아파트 및 다세대주택에 인터넷사업자에 의하여 이미 상용화된 인터넷망이 구축되어 있음에 따라 전력회사의 독자적인 네트워크장비가 아닌 인터넷 사업자에 의하여 펼쳐진 인터넷망을 이용하여 저속 전력선통신 모뎀과 웹서버와의 연결로서 저가이고 구조가 간단하여 시스템의 구성이 간편한 원격검침 및 원격제어 시스템 구성을 목적으로 총 2가지의 하드웨어와 2가지의 소프트웨어를 설계 및 제작하였다.

유비쿼터스 헬스케어 환경 및 지능형 홈 네트워크를 위한 Zigbee & PLC 통합 게이트웨이 개발 (Zigbee & PLC Integrated Gateway Development for U-Health Care Environment and Intelligent Home Network)

  • 손희배;김성윤;이영철
    • 한국정보전자통신기술학회논문지
    • /
    • 제2권4호
    • /
    • pp.73-80
    • /
    • 2009
  • 본 논문에서는 유비쿼터스 헬스케어와 지능형 홈 네트워크 시스템을 위한 전력선 통신과 Zigbee 통신 기반의 통합 게이트웨이를 구현하였다. 전체 시스템은 센서, 통합 게이트웨이, Zigbee 모듈, 전력선 모뎀으로 구성되어있다. 헬스케어 센서에 의해서 수집된 데이터는 통합 게이트웨이에서 저장 및 분석하여 헬스케어제어장치로 전송할 수 있으며, 의료시설 및 각 가정에 쾌적한 환경을 제공하기 위하여 가전 기기를 제어한다. 구현된 통합 게이트웨이는 다양한 유비쿼터스 헬스케어와 지능형 홈 네트워크를 지원할 수 있다.

  • PDF

LabView를 이용한 PC기반의 교육용 전력선망 통신 제어시스템 구현 (Implementation of PC-based education PLC(Power Line-network Communication) control system using Labview)

  • 박태진;이운선;이상희;이종희
    • 한국정보통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.730-739
    • /
    • 2013
  • 국내 에너지의 30%이상이 조명부문에서 소비되고 있어서 그 소비량과 $CO_2$ 배출량은 점차적으로 늘어날 수밖에 없다. 이와 같은 상황에서 스마트그리드 기반의 전등 제어시스템 구축에는 중요한 의미가 있다. 결과적으로 오늘날 산업현장에서 사용되는 전력선망 통신모뎀과 응용 단말기들을 활용, 본 논문은 PC기반의 전력선망 통신 제어시스템을 구현해봄과 동시에 다양한 통신 테스트 장치 및 도구로 활용하는데 유용할 것이다. 실험을 위해서 사용되는 모뎀은 ZIC 프로토콜 기반의 플래넷 제품을 활용하고 응용프로그램은 랩뷰(LabView)를 사용한다. 그 결과는 주로 저속 전력선 통신에 의한 장치 제어에 초점이 맞추어져 있으며, 전력선 통신 실험을 위한 전력선 통신 테스트 장치로 각종 실험을 수행할 수 있다.

PLC and Arduino Interaction Based on Modbus Protocol

  • Jeong, Yunju;Ansari, Md Israfil;Shin, WooHyeon;Kang, Bonggu;Lim, JinSeop;Moon, HyeonSik;Shim, Jaechang
    • 한국멀티미디어학회논문지
    • /
    • 제20권3호
    • /
    • pp.511-519
    • /
    • 2017
  • This Paper introduces the design and communication method between PLC (Programmable Logic Controller) and Arduino based on MODBUS Protocol. MODBUS connection can be established in a new or existing system very easily, therefore we used this protocol in our proposed system. In the field of automatic devices, multi-function serial port such as RS232, RS422, RS485, and so on creates a great convenience to the developer. This proposed system used RS485 as a key mediator for data exchanging on a connected network. We also believe that it will reduce the development cost in various automated industry because this system can be reused or can be implemented any such PLC installed machines. RS485 is used as a communication interface between PLC (as a slave) and Arduino (as a master), through which a reliable network is created for safe and fast communication. Furthermore, RS485 allows multiple devices(up to 32) to communicate at half duplex on a single pair of wires and provides a long connectivity area (up to 1200 meters) as compare to other device, which makes it a user-friendly for various devices in the automated industry. Moreover, Arduino can play as a mediator by connecting third party device and setup a communication network with PLC.

고속 전력선 통신을 이용한 섬유기계 원격제어 시스템 (Remote Control System for Textile Machinery using High Speed Power Line Communication)

  • 차주헌;전성
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2011
  • This paper describes the high speed PLC-based remote control system that can monitor and control textile machineries bi-directionally through Internet. There are many textile machineries without network functions in the factory. We apply the PLC technology in order to give a network function to them in which the existing electric power line is used with network communication lines without separate wiring constructions. In order to realize this system, we have implemented a protocol for network communication of system, high-speed PLC modules, and Ethernet-to-UART modules. Finally we confirmed the effectiveness of system by applying actual test environments.

An Indoor Broadcasting System Using Light-Emitting Diode Lamps Coupled with Power Line

  • Lee, Seong-Ho
    • 센서학회지
    • /
    • 제24권5호
    • /
    • pp.342-347
    • /
    • 2015
  • We introduce an indoor broadcasting system using light-emitting diode (LED) lamps coupled with a 220 V power line. Two couplers connected to the power line constitute a power line communication (PLC) link. The transmission path from an LED lamp to a photodetector forms a visible light communication (VLC) link in free space. When the LED lamp is coupled to the power line, a composite PLC-VLC link is formed, making it possible to transmit a VLC signal beyond line-of-sight. In experiments, a 4 kHz analog signal modulated with a 100 kHz carrier was sent to the power line by a PLC coupler, and LED lamps coupled to the power line detected the signal and radiated it to multiple VLC receivers in the room. This configuration is useful in expanding an indoor VLC sensor network to adjacent rooms or constructing a voice broadcasting system in a building or apartments with existing power lines.

전력IT를 위한 광대역 전력선통신에 관한 연구 (A Study on Broadband PLC for Power IT)

  • 김연수;신재문
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1599-1605
    • /
    • 2011
  • From now on, power line communication was made use of controling using 450 kHz narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. In this paper, analyze the possibility of moving picture transmission for adapting surveillance camera which is among of the application of PLC. To analyze characteristics of channel, estimate the noise and impedance of lab, office, home. In case of noise, there is no problem to communicate each other because of 20 ~ 50 dB gain. In case of impedance, average impedance is about 100 ohm, it satisfy standards of designing modem but because max and min values get out of expectation there are some problem to acquire fully capacity of modems. Its condition is the same as transmission of multimedia data. In this test as more packets, as more handling rate, in lab, for the case that transmit 1,518 byte as the speed of 6 Mbps handling rate is upto 100%, it means possibility of moving picture transmission as the 6 Mbps speed. For delayed time there is no relationship about transmitted packets. As a result, there is no problem about applying surveillance camera via the PLC. And more cameras can work within PLC for considering the number of transmitted frames.

PLC를 이용한 개선된 자동 조명제어시스템 구현 (Implementation of Improved Automatic Lighting System using PLC)

  • 강신욱;주진환;권학철;이석규;박주현
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.99-106
    • /
    • 2010
  • 본 논문에서는 조명에너지 사용을 절감하기 위하여 설계된 자동 조명제어시스템에 전력선 통신(PLC : Power Line Communication)과 단문문자서비스(SMS : Short Message Service)를 적용한 개선된 자동 조명제어시스템을 구현하였다. 본 시스템은 자동 조명제어장치와 함께 재실감지센서에 의하여 화재나 침입자 발생 시 경고음 뿐만 아니라 관리자나 사용자에게 경고 메세지를 전송하여 2차 사고를 예방할 수 있도록 설계되어 있다. 또한 본 논문에서는 전력전송을 위하여 설치된 기존의 전력선에 데이터를 실어 보냄으로써 신호선과 전원선의 통합하여 조명 제어를 위하여 사용되는 라인의 수를 획기적으로 줄이는 개선된 자동 조명제어시스템을 제안하였다.