• Title/Summary/Keyword: PLC

Search Result 1,484, Processing Time 0.038 seconds

Qualitative Inquiry into the Characteristics of Science Teacher Learning Communities: Cases Within and Across Schools (과학 교사 학습공동체 특성에 대한 질적 탐구 -학교안과 학교밖 공동체 사례-)

  • Kwak, Youngsun;Lee, Ki-Young;Jeong, Eunyoung
    • Journal of The Korean Association For Science Education
    • /
    • v.41 no.4
    • /
    • pp.297-310
    • /
    • 2021
  • This study explores the characteristics of within-school and across-school science teacher professional learning communities (hereafter, PLC) qualitatively. In-depth focus group interviews were conducted with science teachers belonging to seven PLCs within the science core school and three PLCs across schools. Interview questions include identity and motivation, major activities, and outcomes of PLC, as well as shortcomings and support plans for PLC. The results include both within-school and across-school science teacher PLCs formed for professional development related to science teaching and learning. Both science PLCs participated in the study showed the characteristics of a 'practice community' that developed a cooperative relationship through reciprocal participation, focusing on shared issues among members. Regarding issues, within-school PLCs focused on microscopic problems such as curriculum reconstruction of subject-matter, while across-school PLCs focused on macro problems such as teacher professional development. Regarding activities and roles as PLC, within-school and across-school science PLCs shared such features as collaborative professional development, and interpersonal education such as mentoring for novice teachers. In terms of PLC's influence and outcomes, science teacher PLCs has a positive effect not only on the teachers themselves, but also on the students and the teacher culture in the school. In addition, science teacher PLCs need improvement of the physical conditions for community operation, and software support such as protocol provision for PLC operation and joint research or re-education with universities. In particular, joint research between universities and science teacher PLCs shows the future orientation of the PLC as an 'inquiry community'. Based on the results, the necessity of active support for science PLC, the necessity of developing a cooperative system between science teacher PLC and universities, and ways to spread the PLC of science core schools to that of general schools were proposed.

Channel Analysis of inside PLC (옥내 전력선 채널 분석)

  • Hong Duc-Pyo;Lee Jin-Mok;Kim Soo-Cheol;Choi Jae-Ho;Hong Hyun-Mun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.456-458
    • /
    • 2006
  • Power line communication: PLC which easy to install at anywhere near outlet for electric machine. PLC uses transmission line for voltage of which is 60 Hz. Signals don't affect to electric machine in PLC because they are very small voltage. One of the important thing is the processes of adding signal to power line and extracting the signal from power line, the other is to choose the strong modulation method which sends signals long distance without loosing in PLC channel. but PLC channel have very high and variable noise and attenuation and then it is very hard to transmit optimally between the transmitter and the receiver. After all, impedance and noise problems of PLC channel must be overcame. Noises of 2 kinds which are AWGN abd impulse noise and attenuation are orated. To overcome the noise. Recently, Multi-carrier Modulation: MCM methods like as OFDM and DMT which are divide the channel into many sub-channel have been studied. those are powerful communication methods in PLC. In this paper, PLC channels made up of 3 numbers of noise and attenuation are simulated for getting BER by Matlab simulink.

  • PDF

The Design and Implementation of a Mobile-agent System for SoftPLC (SoftPLC를 위한 모바일 에이전트 시스템의 설계 및 구현)

  • Bae, Hae-Gwang;Choi, Young-Hyun;Min, Gi-Sung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.11a
    • /
    • pp.31-34
    • /
    • 2006
  • 최근의 PLC는 Ethernet 통신, Field Bus등 새로운 통신규약에 호환성을 갖고 있으며 점점 빠른 연산 속도의 초소형 PLC로 발전해 나가고 있고 공장 자동화와 FMS(Flexible Manufacturing System)에 따른 PLC의 요구는 과거 중규모 이상의 릴레이 제어반 대체 효과에서 현재 고기능화, 고속화의 추세로 소규모 정작 기계에서 대규모 시스템 설비에 이르기까지 적용되고 있다. 그러나 현재 사용되고 있는 PLC는 각 제조사마다 하드웨어형식은 유사하지만 소프트웨어형식인 제어 명령어들이 다르기 때문에 각각의 PLC마다 호환이 되지 않는다는 문제점을 가지고 있어 이 제어 명령어들의 호환성을 위한 솔루션이 필요하다. 이를 해결하기 위하여 본 논문은 IEC1131-3의 표준 언어를 중심으로 제어할 수 있는 Mo-aPLC라는 모바일 에이전트 기반의 softPLC시스템을 제안하였다. 이 시스템은 모바일 에이전트들이 지적 대리인으로서 IEC1131-3의 표준 언어를 제어시스템 제작자에게 활용되어 질 수 있는 코드인 IL언어로 변환하고 이를 랭귀지 프로그래머가 활용할 수 있는 코드인 표준 C코드로 변환하는 것이다. 이 시스템으로 인해 제어시스템 제작자와 랭귀지 프로그래머들이 활용할 수 있는 코드들이 생성되는 것과 표준 C코드로 변환함으로서 논리적인 디버깅(dubugging)이 용이하다는 것을 알 수 있었다.

  • PDF

Mobile-based Educational PLC Environment Construction Model

  • Park, Seong-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.1
    • /
    • pp.61-67
    • /
    • 2022
  • In this paper, we propose a model that can convert some of the simulation program resources to a mobile environment. Recently, smart factories that use PLCs as controllers in the manufacturing industry are rapidly becoming widespread. However, in the situation where it is difficult to operate due to the shortage of PLC operation personnel, the actual situation is that a platform for PLC operation education is necessary. Currently most PLC-related educational platforms are based on 2D, which makes accurate learning difficult and difficult. When a simulation program is applied to distance learning in a general PC environment, many elements are displayed on the monitor, which makes screen switching inconvenient. Experiments with the proposed model confirmed that there was no frame deterioration under general circumstances. The average response time by the request frame was 102 ms, and it was judged that the learner was not at the level of experiencing the system delay.

The Signal Transduction Mechanisms on the Intestinal Mucosa of Rat Following Irradiation (방사선조사후 백서소장점막에서 발생하는 신호전달체계에 관한 연구)

  • Yoo Jeong Hyun;Kim Sung Sook;Lee Kyung Ja;Rhee Chung Sik
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.79-95
    • /
    • 1997
  • Purpose : Phospholipase C(PLC) isozymes play significant roles in signal transduction mechanism. $PLC-\gamma$ 1 is one of the key regulatory enzymes in signal transduction for cellular proliferation and differentiation. Ras oncoprotein, EGFR, and PKC are also known to be involved in cell growth. The exact mechanisms of these signal transduction following irradiation, however, were not clearly documented Thus, this study was Planned to determine the biological significance of PLC, ras oncoprotein, EGFR, and PKC in damage and regeneration of rat intestinal mucosa following irradiation. Material and Method : Sixty Sprague-Dawley rats were irradiated to entire body with a single dose of 8Gy. The rats were divided into S groups according to the sacrifice days after irradiation. The expression of PLC, ras oncoprotein, EGFR and PKC in each group were examined by the immunoblotting and immunohistochemistry. The histopathologic findings were observed using H&I stain, and the mitoses for the evidence of regeneration were counted using the light microscopy & PCNA kit. The Phosphoinositide(PI) hydrolyzing activity assay was also done for the indirect evaluation of $PLC-\gamma$ 1 activity. Results: In the immunohistochemistry , the expression of $PLC-{\beta}$ was negative for all grøups. The expression of $PLC-{\gamma}1$ was highest in the group III followed by group II in the proliferative zone of mucosa. The expression of $PKC-{\delta}1$ was strongly positive in group 1 followed by group II in the damaged surface epithelium. The above findings were also confirttled in the immunoblotting study. In the immunoblotting study, the expressions of $PLC-{\beta}$, $PLC-{\gamma}1$, and $PKC-{\delta}1$ were the same as the results of immunohis-tochemistry. The expression of ras oncoprctein was weakly positive in groups II, III and IV. The of EGFR was the highest in the group II, III, follwed by group IV and the expression of PKC was weakly positive in the group II and III. Conclusion: $PLC-{\gamma}1$ mediated signal transduction including ras oncoprotein, EGFR, and PKC play a significant role in mucosal regeneration after irradiation. $PLC-{\delta}1$ mediated signal transduction might have an important role in mucosal damage after irradiation. Further studies will be necessary to confirm the signal transduction mediating the $PKC-{\delta}1$.

  • PDF

Protocol Monitor System Between Cortex M7 Based PLC And HMI

  • Kim, Ki-Su;Lee, Jong-Chan;Ha, Heon-Seong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.17-23
    • /
    • 2020
  • In this paper, collecting real-time data frames that occur during RS232 communication between an HMI and PLC of automation equipment by sniffing real-time information data frames through MCU without modification of the HMI or PLC, a method is proposed that allows users to collect data without being dependent on the modification of PLC and HMI systems. The user collects necessary information from the sniffing data through the parsing operation, and the original communication interface is maintained by transmitting the corresponding sniffing frame to the destination. The MCU's UART communication interface circuit is physically designed according to the RS232 communication standard, and this additionally improves efficiency more so than an interrupt-based system by using the DMA device inside the MCU. In addition, the data frame IO operation is performed by logically separating the work of the DMA interrupt service routine from the work of the main thread using the circular queue. Through this method, the user receives the sniffing data frame between the HMI and PLC in RS232 format, and the frame transfer between PLC and HMI arrives normally at the original destination. By sniffing the data frame without further modification of the PLC and HMI, it can be confirmed that it arrives at the user system normally.

Identification and Characterization of the Interaction between Heat-Shock Protein 90 and Phospholipase C-γ1

  • Kim, Su-Jeong;Kim, Myung-Jong;Kim, Yong;Si, Fu Chun;Ryu, Sung-Ho;Suh, Pann-Chill
    • BMB Reports
    • /
    • v.33 no.2
    • /
    • pp.97-102
    • /
    • 2000
  • Phosphoinositide-specific phospholipase C-${\gamma}1$ (PLC-${\gamma}1$) is a pivotal mediator in the signal transduction cascades induced by many growth factors. Using a yeast two-hybrid system, heat-shock protein 90 (Hsp90) was identified as a PLC-${\gamma}1$-binding protein. A co-immunoprecipitation experiment, using anti-PLC-${\gamma}1$ antibody, demonstrated an in vivo interaction between Hsp90 and PLC-${\gamma}1$ in the NIH-3T3 cells. The interaction in NIH-3T3 was unaffected by the PDGF treatment, inducing phosphorylation and activation of PLC-${\gamma}1$. Direct interaction between Hsp90 and PLC-${\gamma}1$ was confirmed by in vitro binding experiments using purified Hsp90 and PLC-${\gamma}1$. Furthermore, Hsp90 increased the $PIP_2$-hydrolyzing activity of PLC-${\gamma}1$ up to 2-fold at $0.1{\mu}M$ in vitro. Taken together, we show for the first time, the interaction of PLC-${\gamma}1$ with Hsp90, both in vivo and in vitro. We suggest that Hsp90 may play a role in PLC-${\gamma}1$-mediated signal transduction.

  • PDF

Expression of phospholipase C β1 in olive flounder (Paralichthys olivaceus) following external stress stimulation

  • Woo, Soo Ji;Jang, Hee Young;Lee, Hyung Ho;Chung, Joon Ki
    • Fisheries and Aquatic Sciences
    • /
    • v.19 no.4
    • /
    • pp.18.1-18.10
    • /
    • 2016
  • In this study, to clarify the function of $PoPLC-{\beta}1$, in response to stress challenge, we examined the $PoPLC-{\beta}1$ expression pattern in response to external stress (pathogen-associated molecular pathogen challenge and environmental challenge including temperature and salinity). $PoPLC-{\beta}1$ expression analysis of tissue from olive flounder showed that the messenger RNA (mRNA) was predominantly expressed in the brain, heart, eye, liver, spleen, and stomach. We also tested the mRNA expression of the $PoPLC-{\beta}1$ in the spleen and kidney of olive flounder by RT-PCR and real-time PCR following stimulation with lipopolysaccharide (LPS), concanavalin A (ConA), or polyinosinic:polycytidylic acid (PolyI:C) and compared with the inflammatory cytokines IL-1b and IL-6 in the stimulated flounder tissues. Each of the spleen and kidney and mRNA transcripts of $PoPLC-{\beta}1$ were increased 30- and 10-fold than normal tissue at 1-6 h post injection (HPI) with PolyI:C when the expression of $PoPLC-{\beta}1$ transcript was similar to LPS and ConA. We also tested the expression of $PoPLC-{\beta}1$ in response to temperature and salinity stress. The expression of $PoPLC-{\beta}1$ also was affected by temperature and salinity stress. Our results provide clear evidence that the olive flounder $PLC-{\beta}1$ signal pathways may play a critical role in immune function at the cellular level and in inflammation reactions. In addition, $PLC-{\beta}1$ appears to act as an oxidative-stress suppressor to prevent cell damage in fish.

PLC-Based Smart grid Home Network System Design and Implementation using OPNET Simulation

  • Huh, Jun-Ho;Seo, Kyungryong
    • Journal of Multimedia Information System
    • /
    • v.1 no.2
    • /
    • pp.111-118
    • /
    • 2014
  • The Smart grid refers to the technology that enables efficient usage of electric power by collecting information concerning the power usage and power lines grafting information and communications technology to onto power grids. There are Zigbee, PLC or IEEE 802.11 WLAN MAC as a core technology of the Smart grid, but in this paper, the discussion is focused on the PLC. The PLC is the technology that carries out data communications using power lines and put into practical use in the field of lights or home appliances control recently but PLC-applied communications between electronic devices are rarely seen. For the reason that the PLC uses high-voltage power lines and has a disadvantage of experiencing higher data loss rate caused by the noises produced by going through transformers, the technology is yet to be used in many areas. Nevertheless, the PLC has been studied widely recently in respect that it's the low-cost communication solution for the Smart Metering [1]. Moreover, this technology is emerging as a novel data communication method and discussed as an important technology lately due to the developments of the Smart grid systems and Internet of things (IoT). Thus, in this paper, the results obtained from designing and performing implementation scenario for the PLC-based Smart grid home network system were compared and analyzed with that of IEEE 802.11 WLAN MAC (the foundation technology at Jeju Smart grid Test bed)-based Smart grid home network. Thus, in this paper, OPNET 14.5 PL8, OSI 7 layer, PLC router nodes and PLC nodes had been used for the designing and implementation simulations of both systems. Additionally, QoS was not considered in order to guarantee that all the traffics would not have the same processing priority.

  • PDF

A Study on Dual System for Fault Tolerance of PLC (PLC 오류를 포용하는 이중화 시스템에 관한 연구)

  • Ko, Jae-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.3
    • /
    • pp.397-404
    • /
    • 2011
  • In this research, wish to suggest method to embody system that can accommodate defect of PLC and find actual propriety. Defect permission control system minimizes production damage because enables repair and checking without discontinuance and improve believability about whole system. Propose duplexing of system to embody this fault tolerant system. Therefore, composed control system that can permit defect or breakdown duplexings of various module proposing this system, and confirms to simulation and actuality kiln of defect permission control system through an application experiment, and compares for mean time between defect by estimate and defect special quality and system configuration of failure(failure) to improve believability of PLC control system together. In proposed system expression method and system mode and relation with operation mode, error discovery mode and switching tube of duplexing mode, and PLC's central processing unit of node study algorithm about master-standby conversion driving and continuous operation of 2 channels method that have 2 that is not one and deduced continuous operation method and result about defect permission in this algorithm and applies this result to actuality kiln control system and confirms continuous operation about PLC defect permission.