• Title/Summary/Keyword: PLC(power line communication)

Search Result 278, Processing Time 0.021 seconds

Performance of Double Binary Turbo Code for Power Line Communicaion Systems (고속 전력선통신 시스템의 비이진 터보 부호 성능)

  • Lee, Jae-Sun;Yang, Jae-Su;Woo, Sang-Kyu;Yoon, Byung-Wan;Kim, Jin-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.72-77
    • /
    • 2009
  • In this paper, performance of a turbo-coded PLC system is analyzed and simulated in a power line communication channel. Since the power line communication system typically operates in a hostile environment, turbo code has been employed to enhance reliability of transmitted data. The performance is evaluated in terms of bit error probability. As turbo decoding algorithms, Max-Log-MAP algorithms are chosen and performances are compared. The results in this paper can be applied to OFDM-based high-speed power line communication systems

  • PDF

Study on Channel Characteristics and Feasibility of Narrowband Power Line Communication over Underground Low Voltage Power Lines (지중 저압 전력선의 협대역 전력선통신 채널특성 및 적용성에 대한 연구)

  • Yoo, Hyunwoo;Yoon, Kyung Shub;Kang, Sukyung;Choi, Inji;Park, Byungseok;Kim, Il Han;Kim, Wonsoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.10
    • /
    • pp.874-884
    • /
    • 2013
  • This paper presents in details channel and noise characteristics over narrow bands below 500kHz based on the field tests over underground low voltage(LV) power lines in residential areas in Korean grid. We show that the channel characteristics of narrowband signals over underground LV power line are decent. We first describe methodology of channel characteristic measurements including channel frequency response, noise, and line impedance, and obtain channel characteristics over the underground LV lines in the residential areas. Also based on the measurement results, we adopt the IEEE P1901.2 standard on the FCC High band, and bring up narrow band power line communication network.

Implementation of a High Performance Notch Filter Algorithm for Power Line Communication System (전력선 통신 시스템을 위한 고성능 Notch Filter 알고리즘 구현)

  • Nam, Yun-Ho;Jang, Dong-Won;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.159-166
    • /
    • 2010
  • As Power Line has been already installed over 60% of a residential area all over the world, Broadband Service has been possible using high-speed PLC(Power Line Communication) without new access line installed for Internet access. Because of such reason, PLC is researched as the most suitable service for Last Mile Solution. But, Power Line is designed for transmitting electric power, so peripheral Wireless Communication System is affected by a leak of electric wave. In this paper, we propose a High Performance Notch Filter algorithm in comparison with a existing notch filter for reduction of interference between existing Wireless Communication Service and Power Line Service. In addition, we implement the Notch Filter emulator appling a High Performance Notch Filter and using a embedded board.

An Efficient Routing Path Search Technique in Power Line Communication (효율적인 전력선통신 라우팅 경로 탐색 기법)

  • Seo, Chung-Ki;Kim, Jun-Ha;Jung, Joonhong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1216-1223
    • /
    • 2018
  • As field of application of AMI, AMR uses the power line as the primary means of communication. PLC has a big merit without installation of the new network for communication in a field using the power line which is the existing equipment. However, there is a serious obstacle in commercialization for the instability by noise and communication environment. Therefore, the technical method for maintaining the communication state which overcome such demerit and was stabilized is required essentially. PLC routing technology is applied with the alternative plan now. The routing technology currently managed by field includes many problems by applying the algorithm of an elementary level. PLC routing path search problem can be modeled with the problem of searching for optimal solution as similar to such as optimal routing problem and TSP(Travelling salesman problem). In this paper, in order to search for a PLC routing path efficiently and to choose the optimal path, GA(Genetic Algorithm) was applied. Although PLC was similar in optimal solution search as compared with typical GA, it also has a difference point by the characteristic of communication, and presented the new methodology over this. Moreover, the validity of application technology was verified by showing the experimental result to which GA is applied and analyzing as compared with the existing algorithm.

Interferer Aware Multiple Access Protocol for Power-Line Communication Networks

  • Yoon, Sung-Guk
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.480-489
    • /
    • 2016
  • Hidden station problem can occur in power-line communication (PLC) networks. A simple solution to the problem has been proposed to use request-to-send (RTS)/clear-to-send (CTS) exchange, but this approach cannot solve the hidden station problem perfectly. This paper revisits the problem for PLC networks and designs a protocol to solve it. We first analyze the throughput performance degradation when the hidden station problem occurs in PLC networks. Then, we propose an interferer aware multiple access (IAMA) protocol to enhance throughput and fairness performances, which uses unique characteristics of PLC networks. Using the RTS/CTS exchange adaptively, the IAMA protocol protects receiving stations from being interfered with neighboring networks. Through extensive simulations, we show that our proposed protocol outperforms conventional random access protocols in terms of throughput and fairness.

Implementation and Performance Analysis of PLC Scheme based on SISO/MIMO-OFDM using MRC (최대비 합성법을 이용한 SISO/MIMO-OFDM 기반 전력선 통신 방식 구현 및 성능분석)

  • Yoo, Jeong-Hwa;Choe, Sang-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.2B
    • /
    • pp.176-183
    • /
    • 2011
  • In this paper, we propose the implementation and performance analysis of power line communication based on SISO/MIMO-OFDM which focuses on high speed data transmission in smart grid and future power line grid. We employ Zimmermann frequency model and Middleton Class A model as the multipath power line fading channel and impulse noise channel, respectively. In this paper, in order to improve the three-phase or single-phase PLC performance, we introduce a new MRC (called a&f-MRC) which effectively sums up multiple antenna diversity gain and multipath fading diversity gain. Via simulation, we prove the performance advantage over existing SISO/MIMO systems. In addition, we offer the tradeoff on system design through comparing with MRC, EGC and SC.

Power Quality Monitoring System of Using Power Line Communication (전력선통신을 이용한 전력품질 모니터링 시스템)

  • Hong Ducpyo;Choi Jaeho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.91-97
    • /
    • 2005
  • As the developing of industry, the nonlinear equipments as inverter, converter, SMPS(Switching Mode Power Supply) and motor have been increased. But the sensitive electronic loads to the power quality, such as computers and other electronic equipments, have been spreaded out very fast. Thus, the power quality(PQ) problems and the real time power quality monitering(PQM) are one of the important issues in industry and building area for the intelligent control of the systems. One of them, PQM using PLC(Power Line Communication) have good merits that can send and receive the PQ information without any new network line. This paper presents the PQM hardware and software to monitor the PQ information by using PLC that meets the categories of IEEE Std. 1159.

A Stduy on the Signal Anti-reduction Equipment in Power Line Communication (전력선 통신 시스템을 위한 신호 감쇠 저하 장치 연구)

  • 고종선;김주환;윤성구;이기원
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.370-376
    • /
    • 2000
  • In this paper, a communication system that is not using the communication line but power line is presented. It will be very useful for an information-oriented society with tele-metering and home automation. Conventional system has a difficulty in transmitting information due to decreasing communication voltage and increasing carrier current. Proposed idea is a special type switching amplifier system which has a low inner resistance. It can provide reactive power and does not have low impedance between the transceivers. This new system is proposed to overcome the loss of conductor load in a PLC system.

  • PDF

Implementation of the parking management system based on PLC (PLC기반의 주차장 관리시스템 구현)

  • Ryu, Dong-Wan;Kim, Sun-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.497-499
    • /
    • 2015
  • According to the rapid progress of the altitude information society and various sensor technologies, The role of information and communication systems became important during social activities. In this paper, It is measured access and availability alongside parking and availability using an ultrasonic sensor and a pressure sensor. And the measuring data is sent to the controller by using the PLC (Power Line Communication). And it is implementing the parking management system made secure by controlling the LED and LCD with the received data.

  • PDF

Impedance Characteristics of Overhead Medium-Voltage Power lines for Power Line Communication (전력선통신을 위한 고압 배전선로의 임피던스 특성)

  • Chun Dong-wan;Park Young-jin;Kim Kwan-ho;Shin Chull-chai
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.67-78
    • /
    • 2005
  • In this paper, impedance characteristics of overhead medium-voltage (MV) power line for power line communication (PLC) is analyzed. For analysis, a two-port equivalent network model of MV power lines is derived. By applying the equivalent model and basic transmission line theory, input impedance at the signal induction part is calculated. And also calculated input impedance of power line itself that the medium voltage coupler and coaxial cable effect are removed. For verification, impedance of power lines is measured at a test field for an MV PLC. The results show that impedance of MV power line itself is between $200\;{\Omega}\;and\;300\;{\Omega}$ and converges to a half of their characteristic impedance with increasing frequency. And also measured data is very similar to calculated data.