• Title/Summary/Keyword: PLC(power line communication)

Search Result 278, Processing Time 0.026 seconds

A Study on the Application of Voltage Transformer at Transmission Lines (송전선로측 권선형 변성기 사용에 따른 기술적 고찰)

  • Choi, Ky-Youl;Park, Moon-Bin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1152-1154
    • /
    • 1999
  • Recently. due to the drastic development of communication method between substations for pilot protective relaying system. The power line carrier(PLC) application is getting obsolete. Consequently, the coupling capacitor voltage transformer (CCVT) loses its necessity for the carrier coupling function, and so wound voltage transformer(VT) can be used to substitute CCVT for voltage signal. However, VT has been reported to give rise to ferro-resonance phenomena, so sufficient consideration on applying the VT to line side is required. This study introduces probable technical problems in using the VT on T/L side, and carries out feasibility study on the basis of modeling results by EMTP(Electro-magnetic transient program)

  • PDF

DC Bus Communication Strategy for DC Microgird Using Pulse Frequency Modulation of Power Converter (DC 마이크로 그리드를 위한 컨버터 주파수 변동 제어 전략)

  • Choi, Hyun-Jun;Lee, Won-bin;Jung, Jee-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.207-208
    • /
    • 2016
  • 본 논문에서는 DC 마이크로그리드(MG) 동작의 신뢰성 및 안정성을 향상시키기 위하여, 주파수 변동을 이용한 새로운 DC bus signaling (DBS) 전략을 제안하고자 한다. 제안한 DBS의 경우 스위칭 리플을 사용하여, DC 버스를 통해 연결된 컨버터 등의 소자가 현재 DC bus의 전력에 대한 정보를 얻을 수 있다. DC bus의 전력의 정보는 소비와 생산에 대한 DC bus의 밸런스를 맞추기 위해 사용되고, 이를 통해 각각의 컨버터 동작 영역이 상황에 따라 자동적으로 결정되고, 궁극적으로 자율화 시스템을 구현할 수 있게 된다. 본 논문에서는 DC bus에 나타나는 주파수 성분의 분석 및 변동 전략에 대해 기술하고, 시뮬레이션 및 실험 결과를 통해 제안하고자 하는 알고리즘이 Power Line Communication (PLC) 으로의 가능성과 타당성을 점검하고자 한다.

  • PDF

Analysis of DMT Characteristics for High-speed Power-Line Communication (고속 PLC를 위한 DMT 전송 특성 분석)

  • 윤성하;김정훈;김선효;이영철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.109-112
    • /
    • 2001
  • 본 논문은 고속 전력선 통신을 위한 기댐으로 주파수 범위 0∼30MHz에서 BER 개선을 목적으로 DMT 방식을 실험하였다. 송신단에서 길쌈 부호화 방법을 사용했고, 수신단에서는 비터비 알고리즘을 이용해서 복호화 하였으며, 프레임 동기를 위해서 cyclic prefix를 사용하였다. 전력선 채널 특성을 고려하여 거리에 따른 채널 모의실험을 통해서, 코헤어런트 신호를 분석한 결과에 의해 BER을 우수하게 전송시키는 변조 방식을 분석함으로써 전력선상에서 DMT 특성을 이론적으로 분석하여 정보 전달 범위의 효과를 높일 수 있는 방안을 제시하였다.

  • PDF

Design of A Current-mode Bandpass Filter in Receiver for High speed PLC Modem (고속 전력선통신 모뎀용 수신단측 전류모드 대역통과 필터 설계)

  • Bang, Jun-Ho;Lee, Woo-Choun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4745-4750
    • /
    • 2012
  • In this paper a $6^{th}$ 1MHz~30MHz bandpass filter for Power line communication(PLC) modem receiver is designed using current mode synthesis method which is good to design the low-voltage and low-power filter. The designed bandpass filter is composed of cascade connecting between $3^{rd}$ Butterworth highpass filter and $3^{rd}$ Chebychev lowpass filter. As a core circuit in the current-mode filter, a current-mode integrator is designed with new architecture which can improve gain and unity gain frequency of the integrator. The gain and the unity gain frequency of the designed integrator is each 32.2dB and 247MHz. And the cutoff frequency of the designed $6^{th}$ bandpass filter can be controlled to 50MHz from 200KHz according to controlling voltage and the power consumption is 2.85mW with supply voltage, 1.8V. The designed bandpass filter was verified using a $0.18{\mu}m$ CMOS parameter.

The Design and Implementation of AMI System Using Binary CDMA (Binary CDMA 기반의 AMI 시스템 설계 및 구현)

  • Joe, In-Whee;Jeong, Jong-Yuel
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8C
    • /
    • pp.663-669
    • /
    • 2012
  • To solve the energy problem and finding new growth engines, interest for the smart grid is increasing and related technologies are making great efforts to secure in the world. AMI (Advanced Metering Infrastructure) Among them is the first to be constructed and getting attention as a key component of smart grid. A fusion of various technologies in technology development and demonstration is underway on Jeju Island Smart Grid Demonstration Complex in Korea, and focusing on broadband power line communication technology infrastructure is actively underway in Korea Electric Power Corporation. AMI system using power line communication technology without building a separate communication lines are available for power supply lines, but communication is impossible in occurs because admission to the power company or the ideal infrastructure for communication is not considered. In this paper, we analyze the requirements to build AMI system using Binary CDMA and powerline communications technology, and design the basic communication protocol based on Binary CDMA, implement network management and relay feature. By doing so, ways to apply Ad-hoc Binary CDMA indigenous technology to the AMI system were derived, and could build a system to make use of Wired (PLC) and wireless (Binary CDMA) simultaneously.

A Study on Smart Soil Resistance Measuring Device for Safety Characterized Ground Design in Converged Information Technology (ICT 융합 환경에서의 안전 특성화 접지 설계를 위한 스마트 대지 저항 측정 기술에 관한 연구)

  • Kim, Hong-Yong;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.203-209
    • /
    • 2019
  • In this work, a new land-specific resistance measuring device (GM) and a measuring probe (Grounding Rod) are connected to the WENNER quadrant as power-line communication (PLC). In groups of two (P1,P2) probes, five to ten probes are installed in series on the ground at intervals of 1m, 2m, 4m, 8m, and 16m, respectively. If the PLC signal from the GMD is detected by the receiver of the Probe 1 (P1) for measurement, the minute voltage and current for measurement flow from the PSD (power supply) attached to the probe to the ground, and then, through the soil between P1 and P2, enters the Probe 1 (P2). The resistance value is then measured by the principle of voltage drop due to ground resistance. Measure the earth resistance every T seconds up to 1 trillion and store the measured data on the Arduino Server mounted on the main equipment. Stored measurement data can be derived from formulas by Ohm's Law and from inherent resistance (here,). Data obtained in real time will be linked to CDGES programs installed on Main PC, enabling data analysis and real-time monitoring of the ground environment on land. In addition, a three-dimensional display is possible with 3D graph support by identifying seasonal characteristics such as temperature and humidity of land (soils). The limitations of the study will require specific application measures of Test Bed for commercial access to a model that has been developed and operated experimentally.

Channel characteristics of multi-path power line using a contactless inductive coupling unit (비접촉식 유도성 결합기를 이용한 다중경로 전력선 채널 특성)

  • Kim, Hyun-Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.799-804
    • /
    • 2016
  • Broadband powerline communication (BPLC) uses distribution lines as a medium for achieving effective bidirectional data communication along with electric current flow. As the material characteristics of power lines are not good at the communication channel, the development of power line communication (PLC) systems for internet, voice, and data services requires measurement-based models of the transfer characteristics of the network suitable for performance analysis by simulation. In this paper, an analytic model describing a complex transfer function is presented to obtain the attenuation and path parameters for a multipath power line model. The calculated results demonstrated frequency-selective fading in multipath channels and signal attenuation with frequency, and were in good agreement with the experimental results. Inductive coupling units are used as couplers for coupling the signal to the power line to avoid physical connections to the distribution line. The inductance of the ferrite core, which depends on the frequency, determines the cut-off frequency of the inductive coupler. Coupling loss can be minimized by increasing the number of windings around the coupler. Coupling efficiency was improved by more than 6 dB with three windings compared to the results obtained with one winding.

Design of Integrated Metering System based on Broadband Power-Line Communication and Construction of Test Site for Measurement of its Performance (PLC기반의 통합검침 시스템 설계 및 실증시험망 구축)

  • Choi, Moon-Suk;Ju, Seong-Ho;Lim, Yong-Hun;Choi, Jong-Hyoub
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.174-176
    • /
    • 2008
  • 국내 원격검침시스템은 전기, 가스, 수도 사업자가 독립적으로 시스템을 개발하고 있어 각 검침시스템간의 상호운영성을 보장하지 못할 뿐만 아니라, 원격검침시스템 개발에 대한 중복투자가 이뤄지고 있다. 고속전력선통신 기반의 통합검침시스템을 구축하고 통신프로토콜을 통일하게 되면 각 사업자별 검침용 통신비를 절감할 수 있을 뿐만 아니라, 장비의 유지보수 비용도 절감할 수 있어 저비용으로 효율적인 원격검침이 가능하게 될 것으로 예상된다. 본 논문에서는 전력선통신기반의 통합검침 시스템의 구성과 설계된 통합검침시스템의 성능을 검증하기 위한 실증시험망 구축결과에 대해 소개한다.

  • PDF

A Study of High-Speed Power Lire Communication using M-ary SS System (M-ary SS 시스템을 활용한 고속 전력선 통신 성능에 관한 연구)

  • Moon K. H.;Shin M. C.;Seo H. S.;Choi S. Y.;Choi I. H.;Kim H. M.;Hur N. Y.;Cha J. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.313-315
    • /
    • 2004
  • 최근의 전력선통신(PLC: Power Line Communication)은 협대역인 450KHz에서 광대역인 30MHz로 확대되어 고속의 데이터 전송이 가능하게 되었다[1]. 본 논문에서는 광대역 채널특성과 더불어 고속의 데이터 전송까지 가능하도록 하기 위해 새로운M-ary SS(spread spectrum) 기반의 고속 전력선통신시스템을 제시하고 임펄스잡음과 같은 전력선 채널환경 하에서의 BER(Bite Error Rate)특성에 대한 모의실험을 거쳐서 제안 방식의 유용성을 확인하였다

  • PDF

Development of a Remote Dust Collector Bag Control System using Power Line Communication (전력선 통신을 이용한 원격 집진기 bag 제어 시스템 개발)

  • Kim, Jung-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.91-98
    • /
    • 2010
  • Advances in communications and control technology, the strengthening of the Internet, and the growing recognition of the urgency to reduce the risk and production cost are motivating the development of improvements in the traditional manufacturing industry. In this paper, we developed a remote dust collector bag control system which is a combination of advanced IT and traditional dust collector based on the event. At first, we made the A/D(Analog/Digital) converter using a micro processor because the differential pressure transmission, which is a sensor of the dust collector, produces analog volt data. A/D converter can provide RS-232 communication to connect with Power Line Communication(PLC) modem. And, n-bytes message format was defined for the efficient dust collector bag information transmission from a dust collector to a user. Also, we designed the data types to model the dust collector and the dust collector bag, and they were logically modeled using XML and object-oriented modeling method. In addition to that, we implemented the system for showing the dust collector bag exchange time exactly to users at real-time using various visual user interfaces.