• Title/Summary/Keyword: PLC(power line communication)

Search Result 278, Processing Time 0.025 seconds

Reorganization trend on technical regulation of harm prevention for Power Line Communication (전력선통신 위해방지 기술기준의 개편 동향)

  • Cho, Pyung-dong;Choi, Mun-hwan;Lee, Sang-mu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1071-1074
    • /
    • 2015
  • Technical regulation of harm prevention for power line communication prescribes the technical matters to protect human and other equipment from power line communication equipment. Unified operation of technical regulation of power line communication and line facility installation is more efficient in content. This paper is to discuss the technical background of national PLC system and the direction of reforming related techinal regulations.

  • PDF

Characteristic Impedances in Low-Voltage Distribution Systems for Power Line Communication

  • Kim, Young-Sung;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.29-34
    • /
    • 2007
  • The input and output impedances in a low voltage distribution system is one of the most important matters for power line communication because from the viewpoint of communication, the attenuation characteristic of the high frequency signals is greatly caused by impedance mismatch during sending and receiving. The frequency range is from 1MHz to 30MHz. Therefore, this paper investigates the input and output impedances in order to understand the characteristic of high frequency signals in the low voltage distribution system between a pole transformer and an end user. For power line communication, the model of Korea's low voltage distribution system is proposed in a residential area and then the low voltage distribution system is set up in a laboratory. In the low voltage distribution system, S parameters are measured by using a network analyzer. Finally, input and output impedances are calculated using S parameters.

Development of the line coupler for reliable power line communication system (신뢰적인 전력선 통신을 위한 라인 커플러의 개발)

  • Choi, Won-Ho;Im, Byoung-No;Park, Chong-Yeun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2009-2010
    • /
    • 2006
  • This paper presents an adaptive line coupler to match input impedance of the Power line Communication(PLC) modem between access impedance of the power line. This line coupler provides maximum signal power transmiting capability, high reliability. The structure of this coupler is simple and designed to make a easy and low cost. The proposed line coupler is suitable for Amplitude Shift Keying(ASK) or Phase Shift Keying(PSK) modem. To figure out our models, the analysis of the transmitting features of power line channel is performed in the time domain at the carrier frequency. As a result of this study, we present the values of capacitors in the capacitor bank and adaptive line coupler circuit.

  • PDF

Development of Low Voltage AMI(Advanced Metering Infrastructure) System using PLC (PLC를 이용한 저압 AMI(Advanced Metering Infrastructure) 시스템 구축)

  • Jung, Joon-Hong;Kim, Sung-Man;Jung, Su-Mi;Kim, Kwang-Young;Kim, Hong-San
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.743-744
    • /
    • 2011
  • Currently, the major issue in power system is construction of smart grid. Unlike conventional electricity grids, smart grid allows two-way communication between electricity suppliers and consumers, as well as enabling more dispersed generation and storage of power. The AMI(advanced metering infrastructure) system is the core technology of smart grid and this paper deals with the design methodology of AMI System using PLC(power line communication) networks.

  • PDF

A Study on Operating Position Sensing System of Pull Cord Switches Using Power Line Communication (전력선 통신을 이용한 풀 코드 스위치의 동작위치 인식 시스템에 대한 연구)

  • Choi, Nam-Sup;Lee, Buhm
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.745-748
    • /
    • 2003
  • This paper presents a study on pull cord switch system which is employed in various industry for emergency stop of the equipments. By using power line communication(PLC) technique, in this paper, a new method for operation position detection of pull cord switch is suggested without complicated wiring of separate cables which utilize only 2 lines. Also, using control function of PLC IC, a reset signal for each switch reset can be implemented in the switch status control/sensing device. Finally, this paper shows validity and practical applicability of the proposed operating position sensing system of pull cord switch by implementing the system and revealing the response time and signal through the PLC line.

  • PDF

Development of Power Line Communication based Home Network Message Specification and Systems for Digital White Goods (전력선 통신 기반의 디지털 백색 가전기기용 댁내망 메시지 규약 및 시스템의 개발)

  • Kim, Dong-Sung;Kwon, Wook-Hyun;Kim, Yo-Hi;Shin, Hyun-Jung;Yuh, In-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.709-711
    • /
    • 2000
  • In this paper, a home network message specification and systems based on the Power Line Communication(PLC) are proposed. As a case study, the home network message specification and systems for the white goods are proposed. It is designed for the various home appliances from the lightning to the white goods using power line communication based on Internet protocol. The proposed home network system is composed of the home network message specification with browsing S/W and embedded H/W design based on the power line communication.

  • PDF

Power Line Communication Heating Control System by LonWorks (LonWorks를 이용한 전력선 통신 난방제어 시스템)

  • Kim, Myung-Ho;Kim, Sun-Boo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1150-1155
    • /
    • 2006
  • In a heating control system, the indoor temperature controller transfers temperature signals inputed from the temperature sensor and the user to the valve controller. The valve controller recieves these signals then the valve controller controls the valve driving motor on two position control and controls the indoor temperature. When setting up a new valve driving motor from a long distance it is necessary to set up a new valve controller. But occasionary, due to construction, it is impossible to wire between the existing valve controller and the new valve controller. In this situation, the new and existing valve controllers can communicate via power line communication. In this paper it is proposed heating control system controls on two position control via power line communication.

  • PDF

A Study of Interference-Free Home PLC based on the Binary ZCD Code (연속직교 상관특성을 갖는 아진 코드 기반의 구내용 PLC에 관한 연구)

  • Cha, Jae-Sang;Kim, Seong-Kweon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.38-44
    • /
    • 2006
  • In this paper, a new interference-free Home CDMA-PLC(Code Division Multiple Access-Power Line Communication) system based on the binary ZCD(Zero Correlation Duration) spreading code is proposed as a key solution to overcome the previous problems. Binary ZCD spreading code sets with enlarged family sizes are generated by carrying out a chip-shift operation of the preferred pairs. The properties or the proposed ZCD-PLC systems are effective for MPI(Multi-Path Interference) and MAI (Multiple Access Interference) cancellation in the CDMA-PLC systems. By BER performance simulation, we certified the availability of proposed ZCD-CDMA-PLC system.

RF Channel Characteristics of the Medium-voltage Power Line for PLC (전력선통신을 위한 중 전압용 전력선의 RF채널 특성)

  • Kim, Seon-Hyo;Kim, Gwan-Ho;Lee, Hyeong-Cheol;Sin, Cheol-Jae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.7
    • /
    • pp.316-321
    • /
    • 2002
  • In this Paper, the channel characteristics of the medium voltage(22.9kV) power line to analysis the broadband power line communication in the frequency range up to 30MHz was measured. With the sideband electrical coupler in the operating frequency range from DC to 30MHz, we measured characteristic impedance, noise and attenuation of the medium voltage power line, and then characteristic impedance was measured at the state of unloaded medium voltage power line by Scattering parameter method of Vector Network Analyzer. As a measurement result, Channel impedance shows 100~380$\Omega$ at the less than 15MHz and 70~230$\Omega$ at the more than 15 MHz. Noise characteristics of power line shows -75dBm at 20MHz and Narrowband interference noise was from 3 MHz to 7MHz.

Full CMOS PLC SoC ASIC with Integrated AFE (Analog Frond-End 내장형 전력선 통신용 CMOS SoC ASIC)

  • Nam, Chul;Pu, Young-Gun;Park, Joon-Sung;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.10
    • /
    • pp.31-39
    • /
    • 2009
  • This paper presents the single supply power line communication(PLC) SoC ASIC with built-in analog frond-end circuit. To achieve the low power consumption along with low chip cost, this PLC SoC ASIC employs fully CMOS analog front-end(AFE) and several built-in Regulators(LDOs) powering for Core logic, ADC, DAC and IP Pad driver. The AFE includes RX of pre-amplifier, Programmable gain amplifier and 10 bit ADC and TX of 10bit Digital Analog Converter and Line driver. This PLC Soc was implemented with 0.18um 1 Poly 5 Metal CMOS process. The single power supply of 3.3V is required for the internal LDOs. The total power consumption is below 30mA at standby and 300mA at active which meets the eco-design requirement. The chips size is $3.686\;{\times}\;2.633\;mm^2$.