• 제목/요약/키워드: PIV Measurement

검색결과 359건 처리시간 0.035초

경사각을 갖는 다층채널 흐름의 PIV 계측에 관한 연구 (A Study on PIV Measurement of Multi-Channel Flow with Inclination angle)

  • 조대환
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 춘계학술대회 논문집(Proceeding of the KOSME 2000 Spring Annual Meeting)
    • /
    • pp.153-158
    • /
    • 2000
  • Flow visualization and PIV measurements were conducted to investigate the flow characteristics of multi-channel with inclination angle. The water flow seeded with tiny vegetable powder as tracers revealed details of flow field. The PIV measurement to acquire multi-point velocity data simulatneously was carried out at three space of plates for 5, 10, and 15mm with variation of inlet flow rates of $0.25m^3/h$ and <$0.5m^3/h.$ Experiment results show that space of plates acts a significant role in separating process.

  • PDF

첨단 유동가시화 기술을 이용한 수치해석 검증용 실험 (EXPERIMENTS FOR VALIDATING NUMERICAL ANALYSIS USING ADVANCED FLOW VISUALIZATION TECHNOLOGIES)

  • 이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.14-17
    • /
    • 2008
  • Recently, several advanced flow visualization techniques such as Particle Image Velocimetry (PIV) including stereo PIV, holographic PIV, and dynamic PIV have been developed. These advanced techniques have strong potential as the experimental technology which can be used for verifying numerical simulation. In addition, there would be indispensable in solving complicated thermo-fluid flow problems not only in the industrial fields such as automotive, space, electronics, aero- and hydro-dynamics, steel, and information engineering, but also in the basic research fields of medical science, bio-medical engineering, environmental and energy engineering etc. Especially, NT Nano Technology) and BT (Bio Technology) strongly demand these advanced measurement techniques, because it is difficult for conventional methods to observe most complicated nano- and bio-fluidic phenomena. In this paper, the basic principle of these advanced visualization techniques and their practical applications which cannot be resolved by conventional methods, such as flow in automotive HVAC system, ship and propeller wake, three-dimensional flow measurement in micro-conduits, and flow around a circulating cylinder will be introduced.

  • PDF

첨단 유동가시화 기술을 이용한 수치해석 검증용 실험 (EXPERIMENTS FOR VALIDATING NUMERICAL ANALYSIS USING ADVANCED FLOW VISUALIZATION TECHNOLOGIES)

  • 이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.14-17
    • /
    • 2008
  • Recently, several advanced flow visualization techniques such as Particle Image Velocimetry (PIV) including stereo PIV, holographic PIV, and dynamic PIV have been developed. These advanced techniques have strong potential as the experimental technology which can be used for verifying numerical simulation. In addition, there would be indispensable in solving complicated thermo-fluid flow problems not only in the industrial fields such as automotive, space, electronics, aero- and hydro-dynamics, steel, and information engineering, but also in the basic research fields of medical science, bio-medical engineering, environmental and energy engineering etc. Especially, NT (Nano Technology) and BT (Bio Technology) strongly demand these advanced measurement techniques, because it is difficult for conventional methods to observe most complicated nano- and bio-fluidic phenomena. In this paper, the basic principle of these advanced visualization techniques and their practical applications which cannot be resolved by conventional methods, such as flow in automotive HVAC system, ship and propeller wake, three-dimensional flow measurement in micro-conduits, and flow around a circulating cylinder will be introduced.

  • PDF

고해상도 3차원 상호상관 PIV 알고리듬 개발 (Development of High-resolution 3-D PIV Algorithm by Cross-correlation)

  • 김미영;최장운;이현;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.410-416
    • /
    • 2001
  • An algorithm of 3-D particle image velocimetry(3D-PIV) was developed for the measurement of 3-D velocity field of complex flows. The measurement system consists of two or three CCD camera and one RGB image grabber. In this study, stereo photogrammetty was applied for the 3-D matching of tracer particles. Epipolar line was used to decect the stereo pair. 3-D CFD data was used to estimate algorithm. 3-D position data of the first frame and the second frame was used to find velocity vector. Continuity equation was applied to extract error vector. The algorithm result involved error vecotor of about 0.13 %. In Pentium III 450MHz processor, the calculation time of cross-correlation for 1500 particles needed about 1 minute.

  • PDF

Measurements of a microchannel flow using micro-PIV

  • Lee Inwon;Choi Jayho;Lee In-Seop
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2001년도 Proceedings of 2001 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.44-52
    • /
    • 2001
  • A micro-PIV(particle image velocimetry) measurement has been conducted to investigate flow fields in such microfluidic devices as microchannels and micronozzle. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. Velocity vector fields with a resolution of $6.8\;\times\;6.8{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent molding process. Flow fields in a variety of microchannels as well as micronozzle have been investigated.

  • PDF

Micro-PIV measurement of internal flow in a micro droplet

  • KINOSHITA Haruyuki;KOBAYASHI Toshio;OSHIMA Marie
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.141-145
    • /
    • 2004
  • Visualization and PIV measurements of the symmetrical recirculation flow in a nanoliter-sized droplet have been performed using the micro PIV system. The airflow sweeps over the nanoliter-sized liquid droplet fixed in a microchannel and the frictional force drags the liquid on the round interface, which causes the symmetrical recirculation flow in the droplet. The internal recirculation flow in the droplet has been visualized and measured successfully. The results of micro PIV measurement show the maximum speed of the recirculation flow is up to 10 mm/s. The high-speed recirculation can enhance a stirring effect and generate strong shear in the droplet, resulting in acceleration of mixing.

  • PDF

PIV 및 PDA 계측에 의한 소형 액체로켓엔진 인젝터의 분무특성 연구 (A Study on the Spray Characteristics of Small LRE Injector through PIV and PDA Measurements)

  • 김진석;정훈;김정수;박정;김성초;최종욱;장기원
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.63-67
    • /
    • 2006
  • Spray characteristics of an injector employed in mono-propellant hydrazine thrusters were investigated by PIV(particle image velocimetry) and PDA(phase Doppler anemometry) techniques. The instantaneous plane images captured by PIV measurement were examined in order to judge the pass-fail criteria of spray injection performance according to the specific pressure supplied. PDA technique was also applied to measure the velocity and droplet size of spray which were not obtainable by PIV measurement. The objective of this experimental study is the evaluation of the injector performance which may be utilized for the design of brand-new injector through the clear understanding of spray characteristics.

  • PDF

SI 엔진의 정상유동장치에서 충격식 스월미터와 입자영상유속계의 스월비 측정에 대한 비교 연구 (Comparison of Swirl Ratio Measured by Impulse Swirl Meter and Particle Image Velocimetry in a Steady Flow Bench of SI Engine)

  • 이석종;엄인용;성재용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.437-442
    • /
    • 2015
  • 본 연구에서는 SI 엔진의 정상유동장치에서 충격식 스월미터로 측정한 스월비와 PIV(입자영상유속계) 속도장을 적분하여 구한 스월비를 비교 고찰하였다. PIV 속도장으로부터 스월비를 산출하는 방식에 있어서는 토크를 실린더의 기하학적 중심과 스월 중심에서 각각 계산하여 비교하였다. 또한, 정상유동장치에서 토크의 측정 위치를 변화하여 그에 따른 영향도 고찰하였다. 그 결과, 와류가 안정화되지 못한 상류에서는 충격식 스월미터의 측정값이 PIV로 측정한 값보다 크게 나타났다. PIV 측정에 있어서는 유동 상류에서 실린더 중심을 기준으로 산출한 값이 스월 중심으로 산출한 값보다 작게 나타났다. 측정위치가 하류로 이동하여 스월이 안정화되면서 측정방법에 따른 차이점이 줄어든다.

상호상관 PIV를 이용한 예혼합 분무화염의 계측에 관한 연구 (A Study on Measurement of Premixed Spray Flame using Cross-correlation PIV)

  • 양영준;김봉환
    • 에너지공학
    • /
    • 제14권4호
    • /
    • pp.259-267
    • /
    • 2005
  • 예혼합 분무화염의 상세한 연구기구를 관찰하기 위하여 예혼합 분무화염 중의 분무단면상의 확대촬영과 또한 연소시의 순간적 이차원 유동장을 얻기 위해 미소시간차를 가진 2연속 분무단면 화상에 대해 상호 상관 PIV를 적용하였다. PIV에 통상 사용되어지는 펄스 레이저가 아닌 연속발진 레이저를 PIV에 적용하는 기법 등을 나타내었다. 또한 통계적 PIV 해석법을 이용하여 얻은 상호상관 PIV의 결과를 PDA에 의해 측정된 결과와 비교하여, 상호상관 PIV는 PDA의 계측에 의한 결과와 잘 일치한다는 결론에 이르렀다. 연속발진 레이저를 이용한 상호상관 PIV를 예혼합 분무화염에 적용하여 본 연구에서 적용한 기법이 분무화염의 구조를 관찰하는데 매우 유용함을 검증하였다.

HDD내 유동장에 대한 PIV 계측 기술의 적용 (Application to the Flow in HDD Using PIV Measurement)

  • 공대위;주원구;도덕희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.742-747
    • /
    • 2004
  • Hard disk drives (HDD) in computer are used extensively as data storage capacity. PIV measurement system was used fur 2-dimensional visualization of the unsteady flow between co-rotating disks in air both with a shroud and both with a actual-like case. Geometric parameters are gap height (H) between disks in the case of shroud. The lobe- structured boundary between inner region and outer region was visualized, and the number of dominant vertices was determined clearly. It is found from flow visualization that the number of vortex cells can be correlated with Reynolds number based on H which is defined as R $e_{H}$ =ΩRH/v ranging from 7.96$\times$10$^2$ to 1.43$\times$10$^4$, and decreases as the disk speed increases. In the case of a actual-like case, the boundary between inner region and outer region appears cleary when head position located at outer diameter with no damper. It is detected with a case of head position middle diameter that the tip wake is generated behind HGA using PIV measurement and calculation.n.

  • PDF