• Title/Summary/Keyword: PIN detector

Search Result 54, Processing Time 0.032 seconds

Optical Measurement of Blood Oxygen Saturation for Artificial Heart Using Wavelength of 665nm and 805nm (665nm와 805nm의 파장을 이용한 인공심장용 혈중 산소포화도의 광학적 측정)

  • Park, Se-Kwang;Kwon, Ki-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.75-80
    • /
    • 1993
  • This study describes a non-invasive optical sensor and system in order to obtain oxygen saturation of blood, in-vitro. The sensor contains LED 665nm and 805nm of wavelength for light source and PIN photodiode for light detector in flat pack. The sensor system for measurement of oxygen saturation has breadboarded, including signal amplifier, filter, displayer, A/D converter, microprocessor and memory. Experimental set-up for non-invasive measurement of oxygen saturation in-vitro was done. When the variation of oxygen saturation is compared with that of each wavelength, the variation of 665nm is more than that of 805nm by five times. As oxygen saturation varies from 100% to 60%, and the reflection ratio (R805/R665) is changed linearly. The oxygen saturation in $100%{\sim}60%$ range can be measured with about 5% resolution by the developed sensor, such that if this sensor connects with the main artery and vein, the artificial heart can be controlled rapidly and precisely from measurement of the sensor.

  • PDF

Continuous Blood Pressure Monitoring using Pulse Wave Transit Time

  • Jeong, Gu-Young;Yu, Kee-Ho;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.834-837
    • /
    • 2005
  • In this paper, we describe the method of non-invasive blood pressure measurement using pulse wave transit time(PWTT). PWTT is a new parameter involved with a vascular that can indicate the change of BP. PWTT is measured by continuous monitoring of ECG and pulse wave. No additional sensors or modules are required. In many cases, the change of PWTT correlates with the change of BP. We measure pulse wave using the photo plethysmograph(PPG) sensor in an earlobe and we measure ECG using the ECG monitoring device our made in the chest. The measurement device for detecting pulse wave consists of infrared LED for transmitted light illumination, pin photodiode as light detector, amplifier and filter. We composed 0.5Hz high pass, 60Hz notch and 10Hz low pass filter. ECG measurement device consists of multiplexer, amplifier, filter, micro-controller and RF module. After amplification and filtering, ECG signal and pulse wave is fed through micro-controller. We performed the initial work towards the development of ambulatory BP monitoring system using PWTT. An earlobe is suitable place to measure PPG signal without the restraint in daily work. From the results, we can know that the dependence of PWTT on BP is almost linear and it is possible to monitoring an individual BP continuously after the individual calibration.

  • PDF

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Fabrication of the Noninvasive Tube Voltage Meter of Radiotherapy Simulator and Its Performance Analysis (방사선치료 시뮬레이터의 비접속형관전압계 제작과 성능분석)

  • Kim, Jong-Eon;Yoon, Chun-Sil;Kim, Sung-Hyun;Park, Chang-Hee;Cha, Byung-Youl
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.201-206
    • /
    • 2006
  • In this study, we have fabricated the noninvasive tube voltage meter which can observe the waveform of tube voltage and measure the tube voltage by using the Intensity of X-ray beam irradiated from radiotherapy simulator and also investigated the feasibility for clinical applications. Two pin photodiodes acting as X-ray detectors were arranged in parallel at the position of ${\pm}1.4cm$ in the y-axis of X-ray field and the aluminum filters with different thickness were placed above them. Using this detector, we could get the ratio ($r_{eff}$) of the relative output voltage which is proportional to the thickness of the filters. And the logarithm of effective peak tube voltage ($InkV_{p,eff}$) was obtained by Victoreen's NERO 6000M used as reference tube voltage meter. From the linear regression analysis of $r_{eff}$ and In $kV_{p,eff}$ the correlation coefficient (r) of linear equation was obtained to be 0.996 for the calibration of the tube voltage meter. Therefore, we suggest that the noninvasive tube voltage meter fabricated in this study can be used for clinical applications due to Its high accuracy.

  • PDF

Improvement of Phase Noise for Oscillator Using Frequency Locked Loop (주파수 잠금회로를 이용한 발진기의 위상잡음 개선)

  • Kim, Wook-Lae;Lee, Chang-Dae;Kim, Yong-Nam;Im, Pyung-Soon;Lee, Dong-Hyun;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.7
    • /
    • pp.635-645
    • /
    • 2016
  • In this paper, we showed the phase noise of voltage controlled oscillator(VCO) can be radically improved using FLL(Frequency Locked Loop). At first, a 5 GHz VCO is fabricated using a hair-pin resonator. The fabricated VCO shows a phase noise of -53.1 dBc/Hz at 1 kHz frequency offset. In order to improve the phase noise of the fabricated VCO, a FLL is constructed using the feedback loop that consists of the VCO, a frequency detector composed of 5 GHz resonator, loop-filter, and level shifter. The fabricated FLL is designed to oscillate at a frequency of 5 GHz, and its measured phase noise is about -120.6 dBc/Hz at 1 kHz offset frequency. As a result, the phase noise of VCO can be radically improved by about 67.5 dB applying FLL. In addition, the measured phase noise performance is close to that of crystal oscillator.

Automatic On-Chip Glitch-Free Backup Clock Changing Method for MCU Clock Failure Protection in Unsafe I/O Pin Noisy Environment (안전하지 않은 I/O핀 노이즈 환경에서 MCU 클럭 보호를 위한 자동 온칩 글리치 프리 백업 클럭 변환 기법)

  • An, Joonghyun;Youn, Jiae;Cho, Jeonghun;Park, Daejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.99-108
    • /
    • 2015
  • The embedded microcontroller which is operated by the logic gates synchronized on the clock pulse, is gradually used as main controller of mission-critical systems. Severe electrical situations such as high voltage/frequency surge may cause malfunctioning of the clock source. The tolerant system operation is required against the various external electric noise and means the robust design technique is becoming more important issue in system clock failure problems. In this paper, we propose on-chip backup clock change architecture for the automatic clock failure detection. For the this, we adopt the edge detector, noise canceller logic and glitch-free clock changer circuit. The implemented edge detector unit detects the abnormal low-frequency of the clock source and the delay chain circuit of the clock pulse by the noise canceller can cancel out the glitch clock. The externally invalid clock source by detecting the emergency status will be switched to back-up clock source by glitch-free clock changer circuit. The proposed circuits are evaluated by Verilog simulation and the fabricated IC is validated by using test equipment electrical field radiation noise

Design and Implementation of Optical Receiving Bipolar ICs for Optical Links

  • Nam Sang Yep;Ohm Woo Young;Lee Won Seok;Yi Sang Yeou1
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.717-722
    • /
    • 2004
  • A design was done, and all characteristic of photodetectr of the web pattern type which a standard process of the Bipolar which Si PIN structure was used in this paper, and was used for the current amplifier design was used, and high-speed, was used as receiving optcal area of high altitude, and the module which had a low dark current characteristic was implemented with one chip with a base. Important area decreases an area of Ie at the time of this in order to consider an electrical characteristic and economy than the existing receiving IC, and performance of a product and confidence are got done in incense. First of all, the receiving IC which a spec, pattern of a wafer to he satisfied with the following electrical optical characteristic that produced receiving IC of 5V and structure are determined, and did one-chip is made. On the other hand, the time when AR layer of double is $Si_{3}N_{4}/SiO_{2}=1500/1800$ has an optical reflectivity of less than $10{\%}$ on an incidence optical wavelength of 660 ,and, in case of photo detector which reverse voltage made with 1.8V runs in 1.65V, an error about a change of thickness is very the thickness that can be improved surely. And, as for the optical current characteristic, about 5 times increases had the optical current with 274nA in 55nA when Pc was -27dBm. A BJT process is used, and receiving IC running electricity suitable for low voltage and an optical characteristic in minimum 1.8V with a base with two phases is made with one chip. IC of low voltage operates in 1.8V and 3.0V at the same time, and optical link receiving IC is going to be implemented

  • PDF

The Properties of Beam Intensity Scanner(BInS) in IMRT with Phantom for Three Dimensional Dose Verification

  • Young W. Vahc;Park, Kwangyl;Byung Y. Yi;Park, Kyung R.;Lee, Jong Y.;Ohyun Kwon;Park, Kwangyl;Kim, Keun M.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.64-64
    • /
    • 2003
  • Objectives: Patient dose verification is clinically the most important parts in the treatment delivery of radiation therapy. The three dimensional(3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in intensity modulated radiation therapy(IMRT). We present Beam Intensity Scanner(BInS) system for the pre treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom made software for relative dose conversion of fluorescence signals from scintillator. Methods: This scintillator is fabricated by phosphor Gadolinium Oxysulphide and is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera will be processed by our custom made software to reproduce 3D relative dose distribution. For the intensity modulated beam(IMB), the BInS calculates absorbed dose in absolute beam fluence, which are used for the patient dose distribution. Results: Using BInS, we performed various measurements related to IMRT and found the followings: (1) The 3D dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimating of dynamic and/or static MLC system. This is mostly due to leaf transmission, leaf penumbra, scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multileaf opening. Conclusions: These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planing for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

A Study on Optimized Design of Wideband Pulsed Gamma-ray Detectors (광대역 펄스감마선 탐지센서 최적화설계에 관한 연구)

  • Jeong, Sang-hun;Lee, Nam-ho;Son, Eui-seung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1121-1124
    • /
    • 2015
  • In this paper, we propose and demonstrate an optimal design of wideband pulsed gamma-ray detectors. Pulsed gamma-ray detectors are designed to operate in a dose rate of $1{\times}10^6{\sim}1{\times}10^8rad(Si)/s$. The input parameter was derived based on the energy ratio of pulse gamma-ray spectrum and the time of the energy. The sensor output current was calculated based on the dose rate control circuit. Using the N-type Epi Wafer, the optimum condition detection sensor was designed based on TCAD. The simulation results show that the optimal Epi layer thickness is 45um when applied voltage 3.3V. The doping concentrations are as follows : N-type is an Arsenic as $1{\times}10^{19}/cm^3$, P-type is a Boron as $1{\times}10^{19}/cm^3$ and Epi layer is Phosphorus as $3.4{\times}10^{12}/cm^3$. Pulse gamma-ray detector diameter is the 1.3mm.

  • PDF

Low-noise reconstruction method for coded-aperture gamma camera based on multi-layer perceptron

  • Zhang, Rui;Tang, Xiaobin;Gong, Pin;Wang, Peng;Zhou, Cheng;Zhu, Xiaoxiang;Liang, Dajian;Wang, Zeyu
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2250-2261
    • /
    • 2020
  • Accurate localization of radioactive materials is crucial in homeland security and radiological emergencies. Coded-aperture gamma camera is an interesting solution for such applications and can be developed into portable real-time imaging devices. However, traditional reconstruction methods cannot effectively deal with signal-independent noise, thereby hindering low-noise real-time imaging. In this study, a novel reconstruction method with excellent noise-suppression capability based on a multi-layer perceptron (MLP) is proposed. A coded-aperture gamma camera based on pixel detector and coded-aperture mask was constructed, and the process of radioactive source imaging was simulated. Results showed that the MLP method performs better in noise suppression than the traditional correlation analysis method. When the Co-57 source with an activity of 1 MBq was at 289 different positions within the field of view which correspond to 289 different pixels in the reconstructed image, the average contrast-to-noise ratio (CNR) obtained by the MLP method was 21.82, whereas that obtained by the correlation analysis method was 5.85. The variance in CNR of the MLP method is larger than that of correlation analysis, which means the MLP method has some instability in certain conditions.