• Title/Summary/Keyword: PI algorithm

Search Result 547, Processing Time 0.024 seconds

An Improved Control Approach for DSTATCOM with Distorted and Unbalanced AC Mains

  • Singh, Bhim;Solanki, Jitendra
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.131-140
    • /
    • 2008
  • This paper presents a new control approach of DSTATCOM (distribution static compensator) for compensation of reactive power, unbalanced loading and harmonic currents under unbalanced non-sinusoidal ac mains. The control of DSTATCOM is achieved using Adaline based current estimator based on LMS algorithm to maintain source currents real and undistorted. The dc bus voltage of voltage source converter (VSC) working as DSTATCOM is maintained at constant voltage using a proportional-integral (PI) controller. The DSTATCOM system alongwith proposed control scheme is modeled in MATLAB to simulate the behavior of the system. The practical implementation of the DSTATCOM is carried out using dSPACE DS1104 R&D controller having TMS320F240 as a slave DSP. Simulated and implementation results are presented to demonstrate the effectiveness of the DSTATCOM with Adaline based control to meet the severe load perturbations with different types of loads (linear and non-linear) under distorted and unbalanced AC mains.

A Novel Control Scheme Based on the Synchronous Frame for APF

  • Wang, Yifan;Zheng, Hong;Wang, Ruoyin;Zhu, Wen
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1553-1562
    • /
    • 2017
  • For the purpose of enhancing the performance of the shunt active power filter (APF), this paper presents a novel Fast Weighted Compound Control (FWCC) strategy based on the synchronous frame. In this control strategy, the proposed new repetitive controller can work faster and more stably by reducing the internal model cycle and introducing a damping coefficient. In addition, the harmonic detector can be removed to simplify the structure of the APF owing to the improvements. Furthermore, a proportional-integral (PI) controller is added to work in parallel with the repetitive controller by using a weighted ratio. Then, a convergence speed analysis and design algorithm are given in detail. Simulation and experimental results show that the harmonic distortion is reduced from 2.91% to 1.89%. In addition, the content for each of the characteristic harmonic orders has decreased by more than three times.

Control Technology Based on the Finger Recognition of Robot Cleaners (손가락 인식을 기반으로 한 로봇청소기 제어기술)

  • Yoo, Hyang-Joon;Mok, Seung-Su;Kim, Jun-Seo;Baek, Ji-A;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.139-146
    • /
    • 2020
  • The disadvantage of the general robot cleaner is that it works only on the designated route, so it is impossible to clean the place outside the designated route. Therefore, in this study, the direction control methodology for searching the place other than the designated route based on the finger recognition technology was studied to compensate for the shortcomings of the existing cleaner. Raspberry Pi was used as the main controller and Open CV program was used to recognize the number of fingers. To verify the validity of the proposed methodology, a finger recognition algorithm was implemented using Python language, and as a result of adopting the Logitech C922, the success rate was 100% at 90cm and 70% at 110cm, respectively.

Analysis of a Harmonics Neutralized 48-Pulse STATCOM with GTO Based Voltage Source Converters

  • Singh, Bhim;Saha, Radheshyam
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.391-400
    • /
    • 2008
  • Multi-pulse topology of converters using elementary six-pulse GTO - VSC (gate turn off based voltage source converter) operated under fundamental frequency switching (FFS) control is widely adopted in high power rating static synchronous compensators (STATCOM). Practically, a 48-pulse ($6{\times}8$ pulse) configuration is used with the phase angle control algorithm employing proportional and integral (PI) control methodology. These kinds of controllers, for example the ${\pm}80MVAR$ compensator at Inuyama switching station, KEPCO, Japan, employs two stages of magnetics viz. intermediate transformers (as many as VSCs) and a main coupling transformer to minimize harmonics distortion in the line and to achieve a desired operational efficiency. The magnetic circuit needs altogether nine transformers of which eight are phase shifting transformers (PST) used in the intermediate stage, each rating equal to or more than one eighth of the compensator rating, and the other one is the main coupling transformer having a power rating equal to that of the compensator. In this paper, a two-level 48-pulse ${\pm}100MVAR$ STATCOM is proposed where eight, six-pulse GTO-VSC are employed and magnetics is simplified to single-stage using four transformers of which three are PSTs and the other is a normal transformer. Thus, it reduces the magnetics to half of the value needed in the commercially available compensator. By adopting the simple PI-controllers, the model is simulated in a MATLAB environment by SimPowerSystems toolbox for voltage regulation in the transmission system. The simulation results show that the THD levels in line voltage and current are well below the limiting values specified in the IEEE Std 519-1992 for harmonic control in electrical power systems. The controller performance is observed reasonably well during capacitive and inductive modes of operation.

A Study on layered Space Time Trellis codes for MIMO system based on Iterative Decoding Algorithm (MIMO 시스템에서 반복 복호 알고리즘 기반의 계층적 시공간 부호화 방식 연구)

  • Park, Tae-Doo;Jung, Ji-Won
    • Journal of Navigation and Port Research
    • /
    • v.36 no.10
    • /
    • pp.845-849
    • /
    • 2012
  • The next-generation wireless communication requires fast transmission speeds with various services and high reliability. In order to satisfy these needs we study MIMO system used layered space time coded system (LST) combining space time trellis codes (STTC) with turbo codes. In LST, two codes that are inner and outer codes are concatenated in the serial fashion. The inner codes are turbo Pi codes suggested in DVB-RCS NG system, and outer codes are STTC codes proposed by Blum. The interleaver technique is used to efficiently combine two codes. And we proposed and simulated that a full iteration method between turbo decoder and BCJR decoder to improve the performance instead of only processing inner-iteration turbo decoder. The simulation results of proposed effective layered method show improving BER performance about 1.3~1.5dB than conventional one.

A Study of the Adaptive Control System (適應制御裝置에 關한 硏究)

  • Ha, Joo-Shik;Choi, Kyung-Sam;Kim, Seung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.19-31
    • /
    • 1979
  • Recently the adaptive control system, which keeps the control system always optimal by adjusting the control parameters automatically according to the variations of the plant parameters, have become very important in the field of control engineering. The adaptive control systems are usally composed of the plant identification, the decision of the optimal control parameters, and the adjustment of the control parameters. This paper deals with a method of the adaptive control system when PI or PID controller is used in the feed back control system. Its controlled object (the plant) is assumed to be described by the transfer function of $\frac{ke^{-LS}}{1+TS}$ where k, T and L are steady state gain, time constant and pure dead time respectively, and their values are variable in accordance with the change of environmental circumstance. It has been known that a pseudo-random binary signal is quite effective for the measurement of an impulse response of a plant. In adaptive control systems, however, the impulse response itself is not appropriate to determine the control parameters. In this paper, the authors propose a method to estimate directly the parameters of the plant k, T and L by means of the correlation technique using 3 level M-sequence signal as a test signal. The authors also propose a method to determine the optimal parameters of the PI or PID controller in the sense of minimizing the square integral of the control error in the feed back control system, and the values of the optimal parameters are computed numerically for various values of T and L, and the results are examined and compared with those of the conventional methods. Finally the above-mentioned two methods are combined and an algorithm to struct an adaptive control system is suggested. The experiments for the indicial responses by means of both the model of the temperature control system using SCR actuater and the analog simulations have shown good results as expected, and the effectiveness of the proposed method is verified. The M-sequence generator and the time delay circuit, which are manufactured for the experiments, are operated in quite a good condition.

  • PDF

Analysis of CRC-p Code Performance and Determination of Optimal CRC Code for VHF Band Maritime Ad-hoc Wireless Communication (CRC-p 코드 성능분석 및 VHF 대역 해양 ad-hoc 무선 통신용 최적 CRC 코드의 결정)

  • Cha, You-Gang;Cheong, Cha-Keon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6A
    • /
    • pp.438-449
    • /
    • 2012
  • This paper presents new CRC-p codes for VHF band maritime wireless communication system based on performance analysis of various CRC codes. For this purpose, we firstly describe the method of determination of undetected error probability and minimum Hamming distance according to variation of CRC codeword length. By using the fact that the dual code of cyclic Hamming code and primitive BCH code become maximum length codes, we present an algorithm for computation of undetected error probability and minimum Hamming distance where the concept of simple hardware that is consisted of linear feedback shift register is utilized to compute the weight distribution of CRC codes. We also present construction of transmit data frame of VHF band maritime wireless communication system and specification of major communication parameters. Finally, new optimal CRC-p codes are presented based on the simulation results of undetected error probability and minimum Hamming distance using the various generator polynomials of CRC codes, and their performances are evaluated with simulation results of bit error rate based on the Rician maritime channel model and ${\pi}$/4-DQPSK modulator.

Design of Control Method for ON/OFF Type Actuation System Considering Actuation Limit (구동한계를 고려한 ON/OFF 형식 구동시스템의 구동위치 제어기법 설계)

  • Park, Jungwoo;Park, Iksoo;Park, Dongchang;Hwang, Kiyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.17-28
    • /
    • 2015
  • In this paper, it is accomplished to design a control method for such an actuation system of simplified ON/OFF mechanism with actuation command limit. First of all, based on experimental data, the modeling works for nonlinear/linear actuation dynamics are performed, which are govern by PWM command as a control input. Using the linearized model, a classical PI control method is designed to satisfy the aimed control performance requirements, and a control algorithm is proposed to realize the required control performance in the effective control region through resolving the issue for the PWM command limit which reduces the control performance. Finally, through control simulations, the design method is verified and the corresponding control performance improvement is evaluated.

Electronic Structure and Chemical Bonding of La7Os4C9 (La7Os4C9의 전자구조와 화학결합)

  • Kang, Dae-Bok
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.266-271
    • /
    • 2009
  • In the recently synthesized rare earth transition metal carbide $La_7O_{s4}C_9$ one finds one-dimensional organometallic $[O_{s4}C_9]^{21-}$ polymers embedded in a $La^{3+}$ ionic matrix. The electronic structure of the polymeric $[O_{s4}C_9]^{21-}$ chain was investigated by density of states (DOS) and crystal orbital overlap population (COOP), using the extended Huckel algorithm. A fragment molecular orbital analysis is used to study the bonding characteristics of the $C_2$ units in $La_7O_{s4}C_9$ containing $C_2$ units and single C atoms as well. The title compound contains partially filled Os and carbon bands leading to metallic conductivity. As the observed distances already indicated, the calculations show extensive Os-C interactions. The C-C bond distance in the diatomic $C_2$ units ($d_{C-C}$=131 pm) in the solid is significantly increased relative to $${C_2}^{2-}$$ or acetylene, because antibonding $1{\pi}_g$ orbitals are partially filled by the Os-$C_2(1\;{\pi}_g)$ bonding contribution found at and below the Fermi level.

Design and Realization of a Digital PV Simulator with a Push-Pull Forward Circuit

  • Zhang, Jike;Wang, Shengtie;Wang, Zhihe;Tian, Lixin
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.444-457
    • /
    • 2014
  • This paper presents the design and realization of a digital PV simulator with a Push-Pull Forward (PPF) circuit based on the principle of modular hardware and configurable software. A PPF circuit is chosen as the main circuit to restrain the magnetic biasing of the core for a DC-DC converter and to reduce the spike of the turn-off voltage across every switch. Control and I/O interface based on a personal computer (PC) and multifunction data acquisition card, can conveniently achieve the data acquisition and configuration of the control algorithm and interface due to the abundant software resources of computers. In addition, the control program developed in Matlab/Simulink can conveniently construct and adjust both the models and parameters. It can also run in real-time under the external mode of Simulink by loading the modules of the Real-Time Windows Target. The mathematic models of the Push-Pull Forward circuit and the digital PV simulator are established in this paper by the state-space averaging method. The pole-zero cancellation technique is employed and then its controller parameters are systematically designed based on the performance analysis of the root loci of the closed current loop with $k_i$ and $R_L$ as variables. A fuzzy PI controller based on the Takagi-Sugeno fuzzy model is applied to regulate the controller parameters self-adaptively according to the change of $R_L$ and the operating point of the PV simulator to match the controller parameters with $R_L$. The stationary and dynamic performances of the PV simulator are tested by experiments, and the experimental results show that the PV simulator has the merits of a wide effective working range, high steady-state accuracy and good dynamic performances.