• 제목/요약/키워드: PI Current control

검색결과 416건 처리시간 0.029초

Output Voltage Regulation for Harmonic Compensation under Islanded Mode of Microgrid

  • Lim, Kyungbae;Choi, Jaeho
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.464-475
    • /
    • 2017
  • This study examines a P+multi resonant-based voltage control for voltage harmonics compensation under the islanded mode of a microgrid. In islanded mode, the inverter is defined as a voltage source to supply the full local load demand without the connection to the grid. On the other hand, the output voltage waveform is distorted by the negative and zero sequence components and current harmonics due to the unbalanced and nonlinear loads. In this paper, the P+multi resonant controller is used to compensate for the voltage harmonics. The gain tuning method is assessed by the tendency analysis of the controller as the variation of gain. In addition, this study analyzes the slight voltage magnitude drop due to the practical form of the P+multi resonant and proposes a counter method to solve this problem by adding the PI-based voltage restoration method. The proposed P+multi resonant controller to compensate for the voltage harmonics is verified through the PSIM simulation and experimental results.

Multi-loop PID Control Method of Brushless DC Motors via Convex Combination Method

  • Kim, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.72-77
    • /
    • 2017
  • This paper proposes the explicit tuning rule of multi-loop PID controller for brushless direct current motors to predict the system behaviors in time and frequency domains, using properties of the convex combination method. The convex set of the proposed controllers formulates the envelope to satisfy the performances in time and frequency domains. The final control parameters are determined by solving the convex optimization problem subject to the constraints which are represented as convex set of time domain performances. The effectiveness of the proposed control method is shown in the numerical simulation, in which controller tuning algorithm and dynamics of brushless DC motor are well taken into account.

PSCAD/EMTDC를 이용한 전압 Sag 보상을 위한 배전용 정지형 보상기의 LQR 제어기 설계 (Design of LQR Controller of DSIATCOM for Compensating Voltage Sag Using PSCAD/EMTDC)

  • 이명언;정수영;최규하
    • 에너지공학
    • /
    • 제13권1호
    • /
    • pp.68-74
    • /
    • 2004
  • 본 논문에서는 전압 sag 보상을 위한 배전용 정지형 보상기 (DSTATCOM) 제어기를 설계하고 PSCAD/EMTDC로 확인하였다. DSIATCOM의 전류성분을 dq분해 해석을 통하여 상태방정식을 유도하고 부하모델과 네트워크의 제약조건을 고려하여 결합 모델을 제시하였다. 1선 지락 사고시 PI 제어기보다 LQR 제어기의 응답 특성이 우수함을 검증하고 전압 Sag가 개선됨을 보였다.

전압 플리커 및 고조파 보상을 위한 배전용 STATCON의 제어알고리즘 개발 (Development of Control Algorithm of D-STATCON(Distribution STATic-CONden: Compensations of Voltage Flicker and Harmonics)

  • 전영수;오관일;이기선;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1282-1286
    • /
    • 1999
  • This paper presents the DQ transfomation and space vector modulation method to develop a control algorithm of distribution STATCON(STATic CONdenser) for line voltage regulation, dc link voltage regulation and harmonics compensation. The Performance analysis of a PI with ramp comparision and synchronous reference frame current controller is carried out. Based on these analysis, the control performances are desirable to compensate the harmonics and to regulate de link and line voltage of Distribution line.

  • PDF

영구자석 동기전동기의 강인한 센서리스 속도제어 (Robust Speed Control of Sensorless PMSM)

  • 이동희;손문경;권영안
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.112-114
    • /
    • 1997
  • Recently sensorless PMSM is much studied for the industrial applications and home appliances. Most of sensorless algorithm are based on the motor equations of which coefficients are motor parameters. However, uncertainty of motor parameter effects the accuracy of speed estimation of PMSM. This paper investigates the robust speed control of sensorless PMSM which has robustness to parameter uncertainty or variation. The parameter compensation is performed through PI control of the speed error between the estimated speed and the real speed obtained from the measured current. The proposed algorithm is verified through the experiment.

  • PDF

Sliding Mode Controller Applied to Coupled Inductor Dual Boost Inverters

  • Fang, Yu;Cao, Songyin;Wheeler, Pat
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1403-1412
    • /
    • 2019
  • A coupled inductor-dual boost-inverter (CIDBI) with a differential structure has been presented for application to a micro-inverter photovoltaic module system due to its turn ratio of a high-voltage level. However, it is difficult to design a CIDBI converter with a conventional PI regulator to be stable and achieve good dynamic performance, given the fact that it is a high order system. In view of this situation, a sliding mode control (SMC) strategy is introduced in this paper, and two different sliding mode controllers (SMCs) are proposed and adopted in the left and right side of two Boost sub-circuits to implement the corresponding regulation of the voltage and current. The schemes of the SMCs have been elaborated in this paper including the establishment of a system variable structure model, selection of the sliding surface, determination of the control law, and presentation of the reaching conditions and sliding domain. Finally, the mathematic analysis and the proposed SMC are verified by experimental results.

IMV를 이용한 굴착기 작업장치 궤적제어 (Trajectory Control of Excavator Actuators Using IMV)

  • 정규홍
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권2호
    • /
    • pp.45-54
    • /
    • 2020
  • The IMV is a combination of four two-way valve systems which replace a conventional four-way spool valve to improve efficiency mostly in excavator hydraulics. As the environmental regulations for construction equipment have tightened, some overseas advanced companies have released commercial excavators in which the MCV is implemented with the IMVs. Development of the IMV type MCV relies on the control algorithm as well as the robust performance of proportional flow control valves. In this study, the IMV controller was designed and verified with experiments for the excavator working unit, which determines the IMV mode of operation and the extent of the valve opening in consideration of the load conditions on hydraulic actuators. First, the open-loop controller was designed with a joystick command vs. a PSV reference current map comprising several control parameters in to compensate for the different flow characteristics and non-linearities of two-way flow control valves. Second, the closed-loop controller was designed with the PI control fed by the actuator displacement and outputs actuator percent effort equivalent to the operator's joystick command. Finally, the performance of the IMV type MCV was verified with the trajectory control of position references derived from the energy consumption test standard. Experimental results showed the control performance of the IMV developed in this study, and suggest that future studies to be conducted to advance technical progress.

Control Strategy for Three-Phase Grid-Connected Converters under Unbalanced and Distorted Grid Voltages Using Composite Observers

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.469-478
    • /
    • 2013
  • This paper proposes a novel scheme for the current controller for the grid-side converter (GSC) of permanent-magnet synchronous generator (PMSG) wind turbines to eliminate the high-order harmonics in the grid currents under grid voltage disturbances. The voltage unbalance and harmonics in three-phase systems cause grid current distortions. In order to mitigate the input current distortions, multi-loop current controllers are applied, where the positive-sequence component is regulated by proportional-integral (PI) controllers, and the negative-sequence and high-order harmonic components are regulated by proportional-resonance (PR) controllers. For extracting the positive/negative-sequence and harmonic components of the grid voltages and currents without a phase delay or magnitude reduction, composite observers are applied, which give faster and more precise estimation results. In addition, an active damping method using PR controllers to damp the grid current component of the resonant frequency is employed to improve the operating stability of VSCs with inductor-capacitor-inductor (LCL) filters. The validity of the proposed method is verified by simulation and experimental results.

전압형 PWM 인버터에서의 새로운 데드 타임 보상 기법 (New Dead Time Compensation Method in Voltage-Fed PWM Inverter)

  • 류호선;김봉석;이주현;임익헌;황선환;김장목
    • 전력전자학회논문지
    • /
    • 제11권5호
    • /
    • pp.395-403
    • /
    • 2006
  • 본 논문에서는 전압형 PWM 인버터에서의 새로운 데드 타임 보상 기법을 제안하였다. 전압형 PMW 인버터의 경우 데드 타임 영향과 스위칭 소자의 비선형적인 특성에 의해 전압 왜곡이 발생한다. 특히, 전압 왜곡은 정지 좌표계 상전류에 5차와 7차, 그리고 동기 좌표계 상전류에는 6차 고조파를 발생시킨다. 그 결과 d축 동기 PI 전류 제어기의 적분기 출력은 인버터 기본파 주파수의 6배에 해당하는 맥동을 가지고 있다. 본 논문에서는 d축 전류 제어기의 적분기 출력 신호를 데드 타임 보상을 위한 제어 신호로 사용하였다. 제안된 방법은 실험과 시뮬레이션을 통해 타당성을 검증하였다.

마이크로 프로세서에 의한 영구자석동기 전동기의 구동 (Microprocessor Based Permanent Magnet Synchronous Motor Drive)

  • Yoon, Byung-Do
    • 대한전기학회논문지
    • /
    • 제35권12호
    • /
    • pp.541-554
    • /
    • 1986
  • This paper presents the results of driving performance analysis of permanent magnet synchronous motor using a microprocessor based control system. The system consists of three phase power transistor inverters, three phase controlled rectifier, three central processing units, and sensors. The three CPUs are, respectively, used to generate PWM control signals for the inverter generating three phase sine wave, to generate the gate control signals for firing the converter, and to supervise other two CPUs. The supervisor is used to compute PI control algtorithm to three phase reference sine wave for the inverter. It is also used to maintain a constant voltage frequency ratio for the converter operating as a constant torque controller. The inverter CPU retrieves precomputed PWM patterns from look up tables because of computation speed limitations found in almost available microprocessors. The converter CPU also retrieves precomputed gate control patterns from another look-up tables. For protecting the control ststem from any damage by extraordinary over currents, the supervisor receives the data from current sensor, CT, and break down the CB to isolate the circuits from source. A resolver has a good performance characteristics of overall speed range, especially on low speed range. Therefor the speed control accuracy is impoved. The microprocessor based PM synchronous motor control system, thus, has many advantages such as constant torque characteristics, improvement of wave, limitation on extraordinary over currents, improvement of speed control accuracy, and fast response speed control using multi-CPU and look-up tables.

  • PDF