• Title/Summary/Keyword: PFP

Search Result 65, Processing Time 0.022 seconds

Pentafluorophenylprophyl Ligand-based Liquid Chromatography-Tandem Mass Spectrometric Method for Rapid and Reproducible Determination of Metformin in Human Plasma

  • Yang, Jeong Soo;Oh, Hyeon Ju;Jung, Jin Ah;Kim, Jung-Ryul;Kim, Tae-Eun;Ko, Jae-Wook;Lee, Soo-Youn;Huh, Wooseong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3284-3288
    • /
    • 2013
  • This paper describes first development and validation of pentafluorophenylprophyl ligand-based liquid chromatography coupled to tandem mass spectrometry (PFPLC-MS/MS) method to determine metformin, a highly polar compound, in human plasma. Metformin and Phenformin (internal standard) were extracted from human plasma 50 ${\mu}L$ with a single-step protein precipitation. The chromatographic separation was performed using a linear gradient elution of mobile phase involving 5.0 mM ammonium formate solution with 0.1% formic acid (A) and acetonitrile (B) over 3.0 min of run time on a Phenomenex Luna PFP column. The detection was performed using a triple-quadrupole tandem mass spectrometer (Waters Quattro micro) with electrospray ionization in the mode of positive ionization and multiple-reaction monitoring (MRM). The developed method was validated with 5.0 ng/mL of lower limit of quantification (LLOQ). The calibration curve was linear over 5-3000 ng/mL of the concentration range ($R^2$ > 0.99). The specificity, selectivity, carry-over effect, precision, accuracy and stability of the method met the acceptance criteria. The method developed in this study had had rapidness, simplicity and ruggedness. The reliable method was successfully applied to high throughput analysis of real samples for a practical purpose of a pharmacokinetic study.

Pharmacopuncture for Acute peripheral facial paralysis: A systematic review and meta-analysis of randomized controlled trials

  • Choi, Min-Sun;Kim, Dong Il;Jang, Su Hee
    • The Journal of Korean Medicine
    • /
    • v.36 no.2
    • /
    • pp.8-20
    • /
    • 2015
  • Objectives: This study aims to evaluate the efficacy of pharmacopuncture in the treatment of acute peripheral facial paralysis (APFP) through a meta-analysis of randomized controlled trials to assess the clinical evidence for pharmacopuncture as a treatment for PFP. Methods: Literature was searched using databases. The search terms used were "pharmacopuncture," "sweet BV," "apipuncture," "apitoxin," "injection acupuncture," and "herbal acupuncture" in English and "bongchim," "bongyakchim," and "yakchim" in Korean. The RevMan 5.2 program was used for meta-analysis. Results: In all, 1902 studies were screened and the full texts of 219 articles were reviewed. Of these, nine studies were included in the systematic review and nine studies were included in the meta-analysis. Treatments utilizing bee venom, sweet bee venom (SBV), Soyeom, Calculus Bovis Fel Ursi Moschus (BUM), Hominis Placenta, and Suseunghwagang (SSHG) were observed in nine RCTs. In the forest plot, the diamond favors the PA treatment against the control treatment. (95% CI: 0.34 [0.08, 0.60], Z = 2.57, P = 0.01), which Our meta-analysis in RevMan 5.2 confirmed the significant efficacy of PA in treating APFP. Conclusion: Our systematic review and meta-analysis suggest that treatments using Soyeom, bee venom, and BUM are effective in APFP and they reduce the duration of postauricular pain occurring at the acute stage of APFP. However, due to small effect size, further investigation is needed.

Development and validation of LC-MS/MS for bioanalysis of hydroxychloroquine in human whole blood

  • Park, Jung Youl;Song, Hyun Ho;Kwon, Young Ee;Kim, Seo Jin;Jang, Sukil;Joo, Seong Soo
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.130-139
    • /
    • 2018
  • This study aimed to analyze a high-performance liquid chromatography (HPLC) separation using a pentafluorophenyl column of parent drug hydroxychloroquine (HCQ) and its active metabolite, desethylhydroxchloroquine (DHCQ) applying to determine bioequivalence of two different formulations administered to patients. A rapid, simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for bioanalysis of HCQ and its metabolite DHCQ in human whole blood using deuterium derivative $hydroxychloroquine-D_4$ as an internal standard (IS). A triple-quadrupole mass spectrometer was operated using electrospray ionization in multiple reaction monitoring (MRM) mode. Sample preparation involves a two-step precipitation of protein techniques. The removed protein blood samples were chromatographed on a pentafluorophenyl (PFP) column ($50mm{\times}4.6mm$, $2.6{\mu}m$) with a mobile phase (ammonium formate solution containing dilute formic acid) in an isocratic mode at a flow rate of 0.45 mL/min. The standard curves were found to be linear in the range of 2 - 500 ng/mL for HCQ; 2 - 2,000 ng/mL for DHCQ in spite of lacking a highly sensitive MS spectrometry system. Results of intra- and inter-day precision and accuracy were within acceptable limits. A run time of 2.2 min for HCQ and 2.03 min for DHCQ in blood sample facilitated the analysis of more than 300 human whole blood samples per day. Taken together, we concluded that the assay developed herein represents a highly qualified technology for the quantification of HCQ in human whole blood for a parallel design bioequivalence study in a healthy male.

Whole genome sequence analyses of thermotolerant Bacillus sp. isolates from food

  • Phornphan Sornchuer;Kritsakorn Saninjuk;Pholawat Tingpej
    • Genomics & Informatics
    • /
    • v.21 no.3
    • /
    • pp.35.1-35.12
    • /
    • 2023
  • The Bacillus cereus group, also known as B. cereus sensu lato (B. cereus s.l.), is composed of various Bacillus species, some of which can cause diarrheal or emetic food poisoning. Several emerging highly heat-resistant Bacillus species have been identified, these include B. thermoamylovorans, B. sporothermodurans, and B. cytotoxicus NVH 391-98. Herein, we performed whole genome analysis of two thermotolerant Bacillus sp. isolates, Bacillus sp. B48 and Bacillus sp. B140, from an omelet with acacia leaves and fried rice, respectively. Phylogenomic analysis suggested that Bacillus sp. B48 and Bacillus sp. B140 are closely related to B. cereus and B. thuringiensis, respectively. Whole genome alignment of Bacillus sp. B48, Bacillus sp. B140, mesophilic strain B. cereus ATCC14579, and thermophilic strain B. cytotoxicus NVH 391-98 using the Mauve program revealed the presence of numerous homologous regions including genes responsible for heat shock in the dnaK gene cluster. However, the presence of a DUF4253 domain-containing protein was observed only in the genome of B. cereus ATCC14579 while the intracellular protease PfpI family was present only in the chromosome of B. cytotoxicus NVH 391-98. In addition, prophage Clp protease-like proteins were found in the genomes of both Bacillus sp. B48 and Bacillus sp. B140 but not in the genome of B. cereus ATCC14579. The genomic profiles of Bacillus sp. isolates were identified by using whole genome analysis especially those relating to heat-responsive gene clusters. The findings presented in this study lay the foundations for subsequent studies to reveal further insights into the molecular mechanisms of Bacillus species in terms of heat resistance mechanisms.

Interpretation of Receiver Operating Characteristics (ROC) (ROC(receiver operating characteristics) 해석)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.3
    • /
    • pp.155-158
    • /
    • 2000
  • The purpose of this paper is to explain the making procedure and the usage of receiver operating characteristic (ROC) curve for interpretation of radiographic images. The conventional radiograms obtained after the creation of the lesions in the acrylic plates and were enhanced in color. The observer were informed of which tooth to examine, the 'a priori' probability of a lesion present and the approximate diameter of the lesions. The two groups of films were interpreted separately by the same observer using the same rating scale. The following rating scale was used: A; definitely no lesion, B; probably no lesion, C; not sure, D; probably a lesion, and E; definitely a lesion. In analysis, for each observer the diagnostic results in terms of true positive (TP) and false positive (FP) decisions were plotted on a graph. The lowest point on the graph represents the TP and FP when only decisions designated as E according to the rating scale are included. The next point shows the TP and FP values when diagnoses designated as D are added and so forth. By connecting such plot points, a receiver operating characteristic (ROC) curves is obtained. The area under the curve represents the diagnostic accuracy resulting from a diagnostic performance at pure chance level and a value of 1.0 at perfect performance. This method has been known as an useful method to detect the minute difference for each radiographic technic, each observer and for the different lesion depths.

  • PDF