• 제목/요약/키워드: PET / CT

검색결과 761건 처리시간 0.03초

PET/CT를 이용하여 진단한 구강암의 증례 (Oral cancer diagnosed using PET/CT: A case report)

  • 김영희;양병은;조영민;김성곤
    • Imaging Science in Dentistry
    • /
    • 제36권2호
    • /
    • pp.111-116
    • /
    • 2006
  • PET/CT is a new imaging technology that combines high-quality Positron Emission Tomography (PET) and Computed Tomography (CT). This imaging provides simultaneous anatomical and metabolic information. Therefore PET/CT is useful diagnostic modality for early detection of malignant tumor, accurate staging, decision on therapeutic plan, monitoring response to therapy and rapid detection of recurrence. We report oral and maxillofacial cancers diagnosed by using PET/CT and the usefulness of PET/CT in the evaluation of postoperative recurrence.

  • PDF

핵의학 영상장비 PET/CT의 정도관리와 성능평가 (Quality Assurance and Performance Evaluation of PET/CT)

  • 이병일
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.137-144
    • /
    • 2008
  • Positron emission tomography-computed tomography (PET/CT) provides both functional and anatomical images of high quality non-invasively with better precision in localization than PET alone. Increase in the use of PET/CT, coupled with increasing concerns about the quality of medical services accrued the demands for accurate evaluation of system performance and quality assurance. Thus, well designed programs for performance evaluation and quality assurance are needed. Widely used protocols for performance evaluation of PET are the methods proposed by National Electrical Manufacturers Association (NEMA) in 1994 and 2001. In addition, in order to maintain high quality of PET/CT images, quality assurance programs including periodic (daily, monthly, and yearly). Therefore, in this article, the methods and present state of performance evaluation and quality assurance of PET/CT are reviewed.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • 대한방사성의약품학회지
    • /
    • 제1권2호
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

PET/CT 검사 환자의 피폭선량 경감을 위한 연구 (Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam)

  • 김봉수;표성재;조용귀;신채호;조진우;김창호
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.10-16
    • /
    • 2009
  • 목적 : 환자의 피폭선량 감소를 위해 PET/CT검사 시Pitch를 조절하여 환자의 피폭선량을 줄일 수 있는 방법에 대해 고려해 보고 Pitch 조정이 CT 영상과 PET의 SUV값에 영향을 주어 변화가 있는지를 살펴 보고자 한다. 방법 : Siemens사의 Biograph Positron Emission Tomography (PET) Scanner (CT 형식 : TRCT-240-130 (WCT-240-130)을 사용하였다. 환자의 피폭선량 평가로는 CT 조사선량 측정기인 PTW-DIADOS 11003/1383를 사용하여 선량을 측정하였고 Pitch 조정이 CT 영상에 미치는 영향을 알아보기 위해 AAPM Standard Phantom을 이용하여 pitch 변화에 따른 CT 영상의 공간 분해능을 측정하여 비교하였다. 그리고, PET source consists of a solid radioactive cylinder phantom을 사용하여 Pitch 변화에 따른 Fusion 영상의 SUV값을 산출하여 PET/CT 영상에서 SUV값이 변하였는지 확인하였다. 결과 : 2slice CT scanner에서는 Pitch가 0.7~1.3까지는 방사선량이 크게 떨어지나 1.5~1.9까지는 방사선량의 감소가 작아졌으며 Pitch값이 커질수록 환자의 피폭선량이 작아지는 것을 알 수 있었다. 그리고 Pitch값의 증가에 따른 SUV값의 변화는 거의 없었으며. Pitch값이 PET SUV값에 영향을 주지 않는다는 것을 알 수 있었다. Pitch의 변화가 CT 영상에도 크게 영향을 주지 않는 것을 알 수 있었다. 결론 : 위의 결과로 PET/CT를 사용하는 병원은 영상의 왜곡이 없고 PET SUV값에 영향을 주지 않는 범위 내에서 각 병원에 맞는 Pitch값을 찾아서 환자의 피폭 경감을 위해 노력해야 할 것이다. 그리고 Multi-detector를 가진 CT scanner인 경우에 모두 해당 될 것이라 생각되며 향후 다른 장비에서도 이와 같은 실험이 필요하다 하겠다.

  • PDF

부신종양에서 $^{18}F-FDG$ PET 및 PET-CT의 임상 이용 (Clinical Application of $^{18}F-FDG$ PET and PET-CT in Adrenal Tumor)

  • 황경훈;최덕주;이민경;최원식
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권sup1호
    • /
    • pp.130-133
    • /
    • 2008
  • Adrenal tumors are increasingly detected by widespread use of anatomical imaging such as a, MRI, etc. For these adrenal tumors, differentiation between malignancy and benignancy is very important. In diagnostic assessment of adrenal tumor, $^{18}F-FDG$ PET and PET-CT have been reported to have high diagnostic performance, especially, very excellent performance in evaluation of adrenal metastasis in the oncologic patient. In cases of adrenal incidentalomas, $^{18}F-FDG$ PET or PET-CT is helpful if a or chemical-shift MRI is inconclusive. $^{18}F-FDG$ PET and PET-CT may be applied to the patients with MIBG-negative pheochromocytomas. In summary, $^{18}F-FDG$ PET and PET-CT are expected to be effective diagnostic tools in the management of adrenal tumor.

Barium 조영제의 농도 차이가 PET 검사에 미치는 영향 (Influence on PET Exam Caused by Density Differences of Barium-sulfate Contrast Media)

  • 최우준;신상기;남기표;박순기
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: The evaluation of SUV (Standardized Uptake Values) for quantitative analysis in PET exam is the most significant. In PET exam, we make attenuation correction images by using $^{68}Ge$, $^{137}Cs$ or CT data. At this time, a distorted attenuation map affects quantitative analysis. After the exam using barium-sulfate and high density of barium contrast make attenuation map distorted. And then it brings bed influences on SUV. The aim of this study is to verify the relationship between high density barium-sulfate and SUV in PET exam. Materials and Methods By using $^{18}F$-FDG, we made barium-sulfate powder, density of 0, 1.5, 3, 5, 10 and 15% respectively and acquired PET and PET/CT images per each density. And we examined SUV variations from PET and PET/CT images according to differences of barium's density. Moreover, we finally calculated SUV causing variations in HU (Hounsfield Units) values to justify whether the differences of barium density bring any changes in PET/CT exam. Results: From PET images acquired from transmission scan with $^{68}Ge$, we got SUV figures from 6.46 to 6.8 in barium density between 0 to 15 percent. On the other hand, In PET images acquired from Tx scan that using CT, SUV was 6.77 to 23.73, derived from the same barium density. And CT HU values range from 29 to 2004. Conclusion: PET images from Tx data using $^{68}Ge$ weren't affected by barium density and had no differences in SUV. But in the PET/CT images using CT Tx data, there's considerable variations in HU and SUV values according to a difference of barium density in HU values. To perform a precise examination, barium sulfate should be removed from a human body before performing a PET exam.

  • PDF

위암 환자의 수술 전 림프절 전이 평가를 위한 PET-CT의 진단적 유용성 (The Diagnostic Utility of PET-CT for the Preoperative Evaluation of Lymph Node Metastasis in Gastric Cancer Patients)

  • 박성혁;조민수;류훈;배금석;김익용;김대성
    • Journal of Gastric Cancer
    • /
    • 제8권4호
    • /
    • pp.250-255
    • /
    • 2008
  • 목적: PET-CT가 림프절 전이를 발견하는데 있어 그 정확도를 조사하여 수술 전 진단 도구로써의 유용성을 평가하였다. 대상 및 방법: 2006년 6월부터 2008년 7월까지 원주기독병원에서 위암으로 수술 전 복부(위)전산화단층촬영술 및 PET-CT를 시행 후 근치적 위절제술을 시행한 환자를 대상으로 복부(위)전산화단층촬영술과 PET-CT의 민감도, 특이도, 양성예측률, 음성예측률 그리고 정확도를 비교 평가하였다. 결과: 전체 119명의 PET-CT의 민감도는 32.6%, 복부(위)전산화단층촬영술의 민감도는 39.5%였다. 특이도는 PET-CT 86.8%였으며 복부(위)전산화단층촬영술은 76.3%였다. 양성예측률은 PET-CT 58.3%, 복부(위)전산화단층촬영술 48.6%, 음성예측률은 PET-CT 69.5%, 복부(위)전산화단층촬영술 69.0%였다. 정확도는 PET-CT 67.2%, 복부(위)전산화단층촬영술 63.0%였다. 조기 위암의 경우 PET-CT와 복부(위)전산화단층 촬영술의 특이도는 98.0%와 88.2%, 음성예측률 80.6%와 80.4%, 정확도 67.2%와 63.0%이었다. 진행성 위암인 경우에는 PET-CT와 복부(위)전산화단층촬영술의 민감도는 45.2%와 51.6%, 특이도 64.0%와 52.0%, 양성예측률 60.9%와 57.1%, 음성예측률 48.5%와 46.4%, 정확도 53.6%와 51.8%였다. 결론: 수술 전 PET-CT를 이용한 림프절 전이 여부 평가는 복부(위)전산화단층촬영술에 비해 치료 지침을 결정하는데 더 많은 도움을 줄 수 있을 것으로 사료된다.

  • PDF

두경부 편평상피암 환자에서 수술 전 경부림프절 전이 평가에 대한 F-18 FDG PET/CT의 정확도: CT/MRI와의 비교 (Accuracy of F-18 FDG PET/CT in Preoperative Assessment of Cervical Lymph Nodes in Head and Neck Squamous Cell Cancer: Comparison with CT/MRI)

  • 최승진;변성수;박선원;김영모;현인영
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권6호
    • /
    • pp.309-315
    • /
    • 2006
  • 목적: 두경부 편평상피암 환자에서 경부림프절전이에 대한 F-18 FDG PET/CT의 진단성적을 평가하고 CT/MRI와 비교하였다. 대상 및 방법: 수술전 조직검사로 편평상피암으로 진단받은 17명(남: 15명, 여: 2명, 평균나이: $59{\pm}11$세)의 환자를 대상으로 F-18 FDG PET/CT를 시행하였다. 경부림프절의 F-18 FDG섭취 정도는 세 등급(1=배후방사능, 2=간방사능보다 낮거나 같은 경우, 3=간방사능보다 높은 경우)으로 나누었고, 3등급일 때 전이로 진단하였다. 경부림프절전이에 대한 F-18 FDG PET/CT의 예민도와 특이도를 CT/MRI와 비교하였다. 결과: 17명의 환자에서 123개의 경부림프절이 절제되었고 이 중 29개가 전이로 확진되었다. F-18 FDG PET/CT의 예민도는 69%(20/29), 특이도는 99%(93/94), CT/MRI의 예민도는 62%(18/29), 특이도는 96%(90/94)로 경부림프절전이에 대한 두 검사의 진단성적은 유의한 차이가 없었다. 그러나 F-18 FDG PET/CT는 각각의 환자에서 간에 생긴 이차성 원발암과 늑골전이를 발견할 수 있었다. 결론: 두경부 편평상피암에서 경부림프절 전이에 대한 F-18 FDG PET/CT의 특이도는 매우 높았지만 예민도는 비교적 낮았고 CT/MRI와 유의하게 다르지 않았다. F-18 FDG PET/CT의 비교적 낮은 예민도의 원인은 최근 많이 절제되고 있는 잠재 전이의 가능성이 있는 작은 경부림프절을 발견하지 못하는 F-18 FDG PET/CT 의 한계 때문이었다. 그러나 F-18 FDG PET/CT는 이차성 원발암과 원격전이를 부가적으로 평가할 수 있어 환자의 치료 방침 결정에 유용하였다.

악성 골 및 연부조직 종양에서 $^{18}F$-FDG PET/CT의 임상적 적용 (Clinical Applications of $^{18}F$-FDG PET/CT in Malignant Bone and Soft Tissue Tumors)

  • 신덕섭
    • 대한골관절종양학회지
    • /
    • 제14권2호
    • /
    • pp.86-94
    • /
    • 2008
  • $^{18}F$-FDG PET/CT는 해부학적 영상과 함께 생리적인 변화를 보여주는 영상을 동시에 제공함으로써 진단적 영상검사에 많은 발전을 가져왔고, 근골격계 종양을 평가하는데 새롭고 독창적인 방법으로 등장 하였다. 최근 PET/CT는 골 전이를 찾는데, 골 연부조직 종양의 시기 결정 및 재시기 결정에 많이 사용되고 있다. 또한 악성 근골격계 종양의 치료에 대한 평가와 치료 후 추시에서 국소 재발이나 원격 전이를 찾아내는 데 유용하게 사용되고 있다. 향후 근골격계 종양에 대한 PET/CT의 연구 자료가 축적되고, 발전된다면 초기 진단에도 유용하게 쓰일 수 있을 것으로 사료된다. 이 논문은 근골격계 종양의 평가를 위한 $^{18}F$-FDG PET/CT의 효율적인 적용에 대하여 문헌 고찰과 함께 살펴보고자 한다.

  • PDF

조영증강 $^{18}F$-FDG PET/CT가 이중에너지 X-선 흡수 계측법을 이용한 골밀도 및 체성분 측정에 미치는 영향 (Effect of Contrast-Enhanced $^{18}F$-FDG PET/CT on Measurements of Whole Body Bone Mineral Density and Body Composition by Dual-Energy X-Ray Absorptiometry)

  • 김성수;이선도;이남주;신용철;모은희;이춘호
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.7-11
    • /
    • 2012
  • PET/CT에 사용되는 방사성의약품 FDG와 CT 조영제가 DXA를 이용하여 측정하는 BMC, BMD, TFM, LBM 등의 결과에 미치는 영향을 알아보고자 하였다. 2011년 12월부터 2012년 3월까지 본원 PET/CT를 시행한 환자 중 본 연구에 참여를 동의한 환자 총 22명을 대상으로 하였다. 실험은 두 집단으로 나누어 실험을 진행하였는데 첫 번째 집단은 17명으로 PET/CT 용 방사성의약품인 FDG 정맥 주사 전에 WB DXA를 시행한 다음 FDG 정맥주사 1시간 후 CT 조영제 사용 없이 PET/CT (Non-Contrast Enhancement $^{18}F$-FDG PET/CT)시행 후 즉시 다시 WB DXA를 진행하였다. 두 번째 집단은 총 5명으로 첫 번째 집단과 마찬가지로 FDG 정맥 주사 전 WB DXA를 시행한 다음 FDG 정맥 주사 1시간 후 CT 조영제 사용하여 PET/CT (Contrast Enhancement $^{18}F$-FDG PET/CT)시행 후 즉시 다시 WB DXA 진행하였다. 결과는 PET/CT 전 후 DXA에서 WB-BMC, WB-BMD, TFM 그리고 LBM 등을 측정하였고 각 항목의 변화율을 산출하여 비교하였다. Non-Contrast Enhancement $^{18}F$-FDG PET/CT 전 후의 골밀도 및 체성분의 변화율은 WB-BMC, +2.4%; WB-BMD, +1.8%; TFM, -6.8%; LBM, +2.2%였고 각 항목의 변화는 통계적으로 유의한 차이가 없었다. Contrast Enhancement $^{18}F$-FDG PET/CT 전 후의 변화율은 WB-BMC, +13.7%; WB-BMD, +9.3%; TFM, -34.1%; LBM, +13.6%였고 Contrast Enhancement $^{18}F$-FDG PET/CT 전과 후의 골밀도 및 체성분 측정치의 변화는 통계적으로 유의하였다. 본 연구에서 Non-Contrast Enhancement $^{18}F$ PET/CT 후에는 DXA 시행은 결과에 영향이 없어 가능할 것이라 생각되어지나 Contrast Enhancement $^{18}F$-FDG PET/CT검사 후에 시행한 DXA 검사의 결과는 신뢰도가 감소될 것으로 사료된다.

  • PDF