• Title/Summary/Keyword: PET (Positron Emission Tomography)

Search Result 485, Processing Time 0.035 seconds

Radiolabeled 2D graphitic nanomaterials and their possibility for molecular imaging applications

  • Kang, Seok Min;Kim, Chul Hee;Kim, Dong Wook
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.2
    • /
    • pp.115-120
    • /
    • 2018
  • In recent years, many researchers have attempted to make use of 2D nanoparticles as molecular imaging probes since extensive investigations proved that 2D nanoparticles in the body tends to accumulate certain lesions by enhanced permeability and retention (EPR) effect. For example, graphene and carbon nitride which have high surface area and modifiable properties showed good biocompatibility and targetability when it used as imaging probes. However, poor dispersibility in physiological mediums and its uncontrolled size limited its usage in bio-application. Therefore, oxidation process and mechanical exfoliation have been developed for overcoming these problems. In this paper, we highlight the several major methods to synthesize biocompatible 2D nanomaterials like graphene and carbon nitride especially for molecular imaging study including positron emission tomography (PET).

Diagnostic imaging of malignant insulinoma in a dog

  • Choi, Jihye;Keh, Seoyeon;Kim, Sungsoo;Lee, Su-Hyung;Kim, Hyejin;Choi, Heeyeon;Lim, Younji;Kim, Hyunwook;Kim, Ahyoung;Kim, Dae-Yong
    • Korean Journal of Veterinary Research
    • /
    • v.52 no.3
    • /
    • pp.205-208
    • /
    • 2012
  • Endocrine test data from a 13-year old intact female Maltese was indicative of the presence of an insulinoma, however ultrasonography identified a pancreatic mass only after 10 months after the first admission. Following identification of both pancreatic tumor and hepatic metastasis on computed tomography (CT), surgical excision of the mass was attempted. However, total excision failed because of tumor adhesion to adjacent large vessels. The pancreatic mass was monitored over the next 25 months via ultrasonography, CT, and positron emission tomography-computed tomography (PET-CT). Histopathological and immunohistochemical data confirmed the diagnosis of insulinoma with hepatic metastasis.

Primary Diffuse Large B-Cell Lymphoma of the Seminal Vesicle: a Case Report

  • Kwag, Kyung Su;Jang, Suk Ki;Yeon, Jae Woo;Kwon, Kye-Won;Son, Jeong Hwan;Kim, Hyuk Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.259-263
    • /
    • 2016
  • Primary diffuse large B-cell lymphoma of the seminal vesicle is an extremely rare disorder, with only two cases reported in the English literature. Here, we present imaging findings of a case of primary diffuse large B-cell lymphoma of the seminal vesicle. On transrectal ultrasonography, the mass presented as a 3.0-cm-sized heterogeneous, hypoechoic lesion in the right seminal vesicle. Computed tomography (CT) revealed a mass with rim-like enhancement in the right seminal vesicle. On magnetic resonance imaging (MRI), the tumor showed iso-signal intensity on T1-weighted images and heterogeneously intermediate-high signal intensity on T2-weighted images. The tumor showed rim-like and progressive enhancement with non-enhancing portion on dynamic scanning. Diffusion restriction was observed in the mass. On fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) imaging, a high standardized uptake value (maxSUV, 23.5) by the tumor was noted exclusively in the right seminal vesicle.

Evaluation of energy correction algorithm for signals of PET in heavy-ion cancer therapy device

  • Niu, Xiaoyang;Yan, Junwei;Wang, Xiaohui;Yang, Haibo;Ke, Lingyun;Chen, Jinda;Du, Chengming;Zhang, Xiuling;Zhao, Chengxin;Kong, Jie;Su, Hong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.101-108
    • /
    • 2020
  • In order to solve the contradiction between requirements of high sampling rate for acquiring accurate energy information of pulses and large amount of data to be processed timely, the method with an algorithm to correct errors caused by reducing the sampling rate is normally used in front-end read-out system, which is conductive to extract accurate energy information from digitized waveform of pulse. The functions and effects of algorithms, which mainly include polynomial fitting with different fitting times, double exponential function fitting under different sampling modes, and integral area algorithm, are analyzed and evaluated, and some meaningful results is presented in this paper. The algorithm described in the paper has been used preliminarily in a prototype system of Positron Emission Tomography (PET) for heavy-ion cancer therapy facility.

Optimization of the Coupling and the Reflector Material in the DOI PET Detector Module using the WLS Fiber (파장변이섬유를 사용하는 반응 위치 측정 양전자방출 단층촬영기기 검출기 모듈의 연결물질과 반사체 물질의 최적화)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2019
  • We developed a novel depth-of-interaction positron emission tomography (PET) detector using wavelength shifting (WLS) fibers and optimized it. The optimization module was designed by using two scintillators and three WLS fibers and attaching a sensor to the end of the WLS fiber. Optimum combinations were obtained through the light collection efficiency and the light collection ratio between sensors depending on coupling materials and reflectors of scintillators, WLS fibers and sensors. The highest light collection efficiency and the light collection ratio between sensors were obtained in the combination of the epoxy (coupling materials)-diffuse reflector (scintillators)-specular reflector (WLS fibers).

Prognostic Significance of 18F-fluorodeoxyglucose Positron Emission Tomography (PET)-based Parameters in Neoadjuvant Chemoradiation Treatment of Esophageal Carcinoma

  • Ma, Jin-Bo;Chen, Er-Cheng;Song, Yi-Peng;Liu, Peng;Jiang, Wei;Li, Ming-Huan;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2477-2481
    • /
    • 2013
  • Aims and Background: The purpose of the research was to study the prognostic value of tumor 18F-FDG PET-based parameters in neoadjuvant chemoradiation for patients with squamous esophageal carcinoma. Methods: Sixty patients received chemoradiation therapy followed by esophagectomy and two 18FDG-PET examinations at pre- and post-radiation therapy. PET-based metabolic-response parameters were calculated based on histopathologic response. Linear regression correlation and Cox proportional hazards models were used to determine prognostic value of all PET-based parameters with reference to overall survival. Results: Sensitivity (88.2%) and specificity (86.5%) of a percentage decrease of SUVmax were better than other PET-based parameters for prediction of histopathologic response. Only percentage decrease of SUVmax and tumor length correlated with overall survival time (linear regression coefficient ${\beta}$: 0.704 and 0.684, P<0.05). The Cox proportional hazards model indicated higher hazard ratio (HR=0.897, P=0.002) with decrease of SUVmax compared with decrease of tumor size (HR=0.813, P=0.009). Conclusion: Decrease of SUVmax and tumor size are significant prognostic factors in chemoradiation of esophageal carcinoma.

Electroencephalography for Early Detection of Alzheimer's Disease in Subjective Cognitive Decline

  • YongSoo Shim;Dong Won Yang;SeongHee Ho;Yun Jeong Hong;Jee Hyang Jeong;Kee Hyung Park;SangYun Kim;Min Jeong Wang;Seong Hye Choi;Seung Wan Kang
    • Dementia and Neurocognitive Disorders
    • /
    • v.21 no.4
    • /
    • pp.126-137
    • /
    • 2022
  • Background and Purpose: Early detection of subjective cognitive decline (SCD) due to Alzheimer's disease (AD) is important for clinical research and effective prevention and management. This study examined if quantitative electroencephalography (qEEG) could be used for early detection of AD in SCD. Methods: Participants with SCD from 6 dementia clinics in Korea were enrolled. 18F-florbetaben brain amyloid positron emission tomography (PET) was conducted for all the participants. qEEG was performed to measure power spectrum and source cortical activity. Results: The present study included 95 participants aged over 65 years, including 26 amyloid PET (+) and 69 amyloid PET (-). In participants with amyloid PET (+), relative power at delta band was higher in frontal (p=0.025), parietal (p=0.005), and occipital (p=0.022) areas even after adjusting for age, sex, and education. Source activities of alpha 1 band were significantly decreased in the bilateral fusiform and inferior temporal areas, whereas those of delta band were increased in the bilateral cuneus, pericalcarine, lingual, lateral occipital, precuneus, posterior cingulate, and isthmus areas. There were increased connections between bilateral precuneus areas but decreased connections between left rostral middle frontal area and bilateral frontal poles at delta band in participants with amyloid PET (+) showed. At alpha 1 band, there were decreased connections between bilateral entorhinal areas after adjusting for covariates. Conclusions: SCD participants with amyloid PET (+) showed increased delta and decreased alpha 1 activity. qEEG is a potential means for predicting amyloid pathology in SCD. Further longitudinal studies are needed to confirm these findings.

Development of SiPM-based Small-animal PET

  • Lee, Jin Hyung;Lee, Seung-Jae;Chung, Yong Hyun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.324-329
    • /
    • 2015
  • A decreased number of readout method is investigated to provide precise pixel information for small-animal positron emission tomography (PET). Small-animal PET consists of eight modules, and each module is composed of a $6{\times}6$ array of $2{\times}2{\times}20mm^3$ lutetium yttrium orthosilicate (LYSO) crystals optically coupled to a $4{\times}4$ array of $3{\times}3mm^2$ silicon photomultipliers (SiPMs). The number of readout channels is reduced by one-quarter that of the conventional method by applying a simplified row and column matrix algorithm. The performance of the PET system and detector module was evaluated with Geant4 Application for Emission Tomography (GATE) 6.1 and DETECT2000 simulations. In the results, all pixels of the $6{\times}6$ LYSO array were decoded well, and the spatial resolution and sensitivity, respectively, of the PET system were 1.75 mm and 4.6% (@ center of field of view, energy window: 350-650 keV).

Effectiveness of Positron Emission Tomography in the Pre-operative Staging of Gastric Cancer (위암환자의 술 전 병기 결정에서 PET-CT의 유용성)

  • Park, Shin-Young;Bae, Jung-Min;Kim, Se-Won;Kim, Sang-Woon;Song, Sun-Kyo
    • Journal of Gastric Cancer
    • /
    • v.9 no.3
    • /
    • pp.110-116
    • /
    • 2009
  • Purpose: The aim of this study was to examine the usefulness of positron emission tomography (PET)-computed tomography (CT) in the pre-operative staging of gastric cancer. Materials and Methods: Between February 2006 and August 2008, PET-CT and CT were performed on 70 patients diagnosed with gastric cancer by gastrofiberscopic biopsy. The sensitivities, specificities, Positive predictive value (PPV), and negative predictive value (NPV) of PET-CT and CT imaging for the detection of gastric cancer TNM staging were compared. Results: The detection rates for the primary tumor were as follows: PET-CT, 81.4% (57/70); and CT, 42.9% (30/70). For both early gastric cancer (EGC) and advanced gastric cancer (AGC), PET-CT was more accurate than CT in detecting the lesions. As the size of the tumor exceeded 3 cm, the detection rate increased. The sensitivities, specificities, PPV, and NPV of PET-CT for lymph node staging were 55.6%, 81%, 86.2%, and 45.9%, while the sensitivities, specificities, PPV, and NPV of CT were 40.0%, 85.7%, 85.7% and 40%, respectively. One case of multiple liver metastasis and two cases of dual primary cancer (rectal and pancreatic cancers) were detected by PET-CT. PET-CT also had a higher detection rate for all histologic types of primary tumors. PET-CT was more accurate than CT in detecting primary gastric cancer lesions. The detection of nodal metastasis by PET-CT was similar to CT; small-sized tumors or EGC detection rates were not high. However, PET-CT provided additional information to detect distant metastases and dual primary cancers and reduced unnecessary laparotomies to detect peritoneal seeding or carcinomatosis. Conclusion: It would be useful to make a pre-operative diagnosis of gastric cancer and determine treatment if PET-CT were added to other routine pre-operative studies.

  • PDF

Dopamine Transporter Imaging in Neurodegenerative Disorders (신경계 퇴행성 질환에서의 도파민 운반체 영상)

  • Kim, Jae-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • The dopamine transporter (DAT) is responsible for the re-uptake of dopamine from the synaptic cleft and is located on dopaminergic nerve terminals only. DAT single photon emission computed tomography (SPECT) and positron omission tomography (PET) imaging, therefore, offer the unique opportunity to study via striatal uptake the integrity of presynaptic dopaminergic nerve terminals in vivo. In recent years SPECT and PET using specific ligands binding to DAT have evolved as an useful tool for diagnosing and monitoring progression of neurodegenerative disorders affecting dopaminergic systems. This article briefly reviews the literature dealing with DAT SPECT and PET imaging in parkinsonism and other neurodegenerative disorders.