• Title/Summary/Keyword: PD pattern

Search Result 239, Processing Time 0.035 seconds

The surface propery change of multi-layer thin film on ceramic substrate by ion beam sputtering (이온빔 스퍼터링법에 의한 다층막의 표면특성변화)

  • Lee, Chan-Young;Lee, Jae-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.259-259
    • /
    • 2008
  • The LTCC (Low Temperature Co-fired Ceramic) technology meets the requirements for high quality microelectronic devices and microsystems application due to a very good electrical and mechanical properties, high reliability and stability as well as possibility of making integrated three dimensional microstructures. The wet process, which has been applied to the etching of the metallic thin film on the ceramic substrate, has multi process steps such as lithography and development and uses very toxic chemicals arising the environmental problems. The other side, Plasma technology like ion beam sputtering is clean process including surface cleaning and treatment, sputtering and etching of semiconductor devices, and environmental cleanup. In this study, metallic multilayer pattern was fabricated by the ion beam etching of Ti/Pd/Cu without the lithography. In the experiment, Alumina and LTCC were used as the substrate and Ti/Pd/Cu metallic multilayer was deposited by the DC-magnetron sputtering system. After the formation of Cu/Ni/Au multilayer pattern made by the photolithography and electroplating process, the Ti/Pd/Cu multilayer was dry-etched by using the low energy-high current ion-beam etching process. Because the electroplated Au layer was the masking barrier of the etching of Ti/Pd/Cu multilayer, the additional lithography was not necessary for the etching process. Xenon ion beam which having the high sputtering yield was irradiated and was used with various ion energy and current. The metallic pattern after the etching was optically examined and analyzed. The rate and phenomenon of the etching on each metallic layer were investigated with the diverse process condition such as ion-beam acceleration energy, current density, and etching time.

  • PDF

Characteristics of Mammary Paget's Disease in China: a National-wide Multicenter Retrospective Study During 1999-2008

  • Zheng, Shan;Song, Qing-Kun;Zhao, Lin;Huang, Rong;Sun, Li;Li, Jing;Fan, Jin-Hu;Zhang, Bao-Ning;Yang, Hong-Jian;Xu, Feng;Zhang, Bin;Qiao, You-Lin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.1887-1893
    • /
    • 2012
  • The aim of this study was to detail characteristics of mammary Paget's disease (PD) representing the whole population in China. A total of 4211 female breast cancer inpatients at seven tertiary hospitals from seven representative geographical regions of China were collected randomly during 1999 to 2008. Data for demography, risk factors, diagnostic imaging test, physical examination and pathologic characters were surveyed and biomarker status was tested by immunohistochemistry. The differences of demography and risk factors between PD with breast cancer and other lesions were compared using Chi-square test or t-test, with attention to physical examination and pathological characters. The percentage of PD was 1.6% (68/4211) in all breast cancers. The mean age at diagnosis was 48.1, and 63.2% (43/68) patients were premenopausal. There is no difference in demography and risk factors between PD with breast cancer and other breast cancer (P > 0.05). The main pattern of PD in physical exam and pathologic pattern were patients presenting with a palpable mass in breast (65/68, 95.6%) and PD with underlying invasive cancer (82.4%, 56/68) respectively. The rate of multifocal disease was 7.4% (5/68). PD with invasive breast cancer showed larger tumor size, more multifocal disease, lower ER and PR expression and higher HER2 overexpression than those in other invasive breast cancer (P < 0.05). These results suggested that PD in China is a concomitant disease of breast cancer, and that PD with underlying invasive cancer has more multiple foci and more aggressive behavior compared with other breast invasive cancer. We address the urgent needs for establishing diagnostic and therapeutic guidelines for mammary PD in China.

Characteristics of Brain Perfusion in Patients of Parkinson's Disease (파킨슨병 환자의 뇌관류 분석)

  • Jeong, Young-Jin;Park, Min-Jung;Kim, Jae-Woo;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.17-28
    • /
    • 2008
  • Purpose: It was well known that cerebral blood perfusion is normal or diffusely decreased in the majority of patients with Parkinson's disease (PD). Actually we interpreted brain perfusion SPECT images of PD patients in the clinical situation, we observed various cerebral perfusion patterns in patients with PD. So we performed brain perfusion SPECT to know the brain perfusion patterns of PD patients and the difference of perfusion patterns according to the sex and the age. Also we classified PD patients into small groups based on the brain perfusion pattern. Methods and Materials: Two hundred nineteen patients (M: 70, F: 149, mean age: $62.9{\pm}6.9$ y/o) who were diagnosed as PD without dementia clinically and 55 patients (M:15, F:40, mean age: $61.4{\pm}9.2$ y/o) as normal controls who had no past illness history were performed $^{99m}Tc$-HMP AO brain perfusion SPECT and neuropsychological test. Results: At first, we compared all patients with PD and normal controls. Brain perfusion in left inferior frontal gyrus, left insula, left transverse temporal gyrus, left inferior parietal lobule, left superior parietal lobule, right precuneus, right caudate tail were lower in patients with PD than normal controls. Secondly, we compared male and female patients with PD and normal controls, respectively. Brain perfusion SPECT showed more decreased cerebral perfusion in left hemisphere than right side in both male and female patients compared to normal controls. And there was larger hypoperfusion area in female patients compared with male. Thirdly, we classified patients with PD and normal controls into 4 groups according to the age and compared brain perfusion respectively. In patient below fifties, brain perfusion in both occipitoparietal and left temporal lobe were lower in PD group. As the patients with PD grew older, hypoperfusion area were shown in both frontal, temporal and limbic lobes. Fourthly, We were able to divide patients into small groups based on cerebral perfusion pattern. There was normal cerebral blood perfusion in 32 (14.7%) of 219 patients with PD, decreased perfusion on the frontal lobe in 45 patients (20.6%), the temporal lobe in 39 patients (17.4%), the parietal lobe in 39 patients (17.9%), the occipital lobe in 40 patients (18.3%), diffuse area in 14 patients (6.4%) and unclassified in 10 patients (4.6%). Fifthly, we compared the results of the neuropsychological test and cerebral perfusion pattern. There was no correlation between two tests except visuospatial function. Conclusion: Various perfusion state were found in patients with PD according to the age and sex. Also we were able to classify perfusion state into several groups and compare the neuropsychological test with cerebral perfusion.

Properties and Classification of Patterns of Air Discharges (기중방전의 방전원별 특성분석 및 패턴분류)

  • Park, Yeong-Guk;Lee, Gwang-U;Jang, Dong-Uk;Gang, Seong-Hwa;Jeong, Gwang-Ho;Kim, Wan-Su;Lee, Yong-Hui;Im, Gi-Jo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

Locating Particle by Ultrasonic Signal and Partial Discharge Signal Pattern in GIS (초음파 신호와 부분방전 신호의 패턴에 의한 GIS내 파티클 위치 추정)

  • 곽희로;이동준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.12-18
    • /
    • 2000
  • This paper describes the analysis of ultrasonic signal and partial discharge(PD) signal patterns for each location of particle in GIS. The characteristics of the ultrasonic signal and PD signal patterns for each location were as follows; in case of particle on the electrode, large ultrasonic signals and large PD signals occurred in positive half-cycle periodically; in case of particle on the spacer, ultrasonic signals and large PD signals occurred in negative half-cycle periodically; in case of the free moving particle, ultrasonic signals and large PD signals occurred by collision non-periodically. As a result, it was confirmed that particle in GIS could be located by the comparison and analysis of ultrasonic signal and PD signal patterns.

  • PDF

An application of the Novel Method to Detect Partial Discharges for GITR using Pockels Sensor (포켈스 센서를 이용한 부분 방전 측정 기술의 GITR 적용)

  • Lee, Jae-Ho;Chang, Yong-Moo;Koo, Ja-Yoon;Park, Ki-Jun;Lee, Young-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1997-1999
    • /
    • 2004
  • In this paper, a novel method has been proposed by use of HY-Pockels sensor for the detection of PD in GITR(Gas Insulated Transformer) in order to improve reliability and to overcome the shortcomings of other techniques which are currently employed. For this work, different types of the test specimen, simulating the winding of the real GITR, have been designed and fabricated to generate the PD. And then, the detection of PD has been realized by conventional methods according to IEC 270 and also the proposed novel sensor as well. Afterwards, their results are well compared to understand the correlation between the nature of the defects in the winding and their PD pattern.

  • PDF

Development of On-Line Monitoring System for Pumped Storage Generator/Motor (양수발전소 발전-전동기 운전중 감시 시스템의 개발)

  • 김희동;주영호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.168-174
    • /
    • 2004
  • On-line monitoring system(OMS) has been developed for the pumped storage generator/motor The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap between stator and rotor. The OMS consists of DAS(data acquisition system), main server system, gateway and display PC. The DAS measures the PD, the shorted-turn and air-gap from three sensors installed on the generator/motor. The gateway controls the data which sent by DAS. The main server system saves the data, analyzes the data and conducts the diagnostic algorithm. The display PC shows the diagnostic results of partial discharge, shorted-turn and air-gap. Field tests were conducted using PDA(partial discharge analyzer). The results of the OMS and PDA measurements can be directly correlated with normalized quantity number(NQN), PD magnitude(Qm) and PD pattern.

A Study on Pattern Characteristics of Multi-Defect Partial Discharge (다중결함 부분방전의 패턴특성 연구)

  • Lee, June-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.970-972
    • /
    • 1998
  • In practice, there may be various defects in an insulating system, so that the PD signals can be produces from these defect simultaneously. Regarding these situations, we have to discriminate the type of defect as well as to determine whether the PD occurs or not. In our research. some analysis results of the PD signals from multi-defects insulating system will be presented. We measure the PD signals using three kind of electrode system: IEC(b). Needle-Plane and mixed electrodes. To simulate multi-defect systems, we combine two electrode systems and apply test voltage simultaneously. Neural network, statistical analysis methods will be tested, and the possibilities and limitations of each method will be clarified.

  • PDF

A Fabrication and Characteristics of GaInAs/InP PIN Phtodiode Grown by LPE (LPE에 의한 GaInAs/InP PIN Photodiode의 제작 및 특성)

  • 박찬용;남은수;박경현;김상배;박문수;이용탁;홍창희
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.737-746
    • /
    • 1990
  • Ga0.47In0.53As PIN photodiodes(PD) having various areas have been fabricated by liquid phase epitaxial techniques. Ternary melt has been baked out at 675\ulcorner in H2 atmosphere for 20 hours before growth, which resulted in reduction of background carrier concentration of grown epi-layer. Also, lattice mismatch has been controlled within 0.01%. The room temperature performance of 10**-4cm\ulcornerarea PIN PD at a bias voltage of -5V were` quantum efficiency(with no antireflection coating)=60% for 1.3\ulcorner light source, dark current\ulcorner5nA, and capacitance\ulcornerpE. Frequency response measurement of packaged PIN PD has shown that cut-off frequency (f-3dB) was 961MHz. This PD has shown a good eye pattern when it was incorporated in a 565Mbps optical receiver.

  • PDF

Feature Extraction for Fault Signals of High Voltage Motor Stator Windings (고압전동기 결함신호의 특징추출에 관한 연구)

  • Park, Jae-Jun;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1154-1157
    • /
    • 2004
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[KV]and 6.67[KV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

  • PDF