• Title/Summary/Keyword: PD pattern

Search Result 240, Processing Time 0.03 seconds

Some Considerations on the On-site Applicability of PSA(Pulse Sequence Analysis) as a Partial Discharge Analysis Method (부분방전 해석 방법으로 PSA(Pulse Sequence Analysis)의 현장 적용성에 대한 고찰)

  • Kim, Jeong-Tae;Lee, Ho-Keun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.5
    • /
    • pp.484-489
    • /
    • 2005
  • Because of its effectiveness for the PD(Partial Discharge) pattern recognition, PSA(Pulse Sequence Analysis) has been considered as a new analytic method instead of conventional PRPDA(Phase Resolved Partial Discharge Analysis). However, it is generally thought that PSA has some possibility to misjudge patterns in case of data-missing resulting from poor sensitivity because it analyses the correlation between sequential pulses, which leads to hesitate to apply it to on-site. Therefore, in this paper, the problems of PSA such as data-missing and noise-adding cases were investigated. for the purpose, PD data obtained from various defects including noise-adding data were used and analyzed. As a result, it was shown that both cases could cause fatal errors in recognizing PD patterns. In case of the data missing, the error was dependant on the kinds of defect and the degree of degradation Also, it could be noticed that the error due to adding noises was larger than that due to some data missing.

HFPD Characteristic Analysis of Simulated Transformer According To Applied Voltage (인가전압에 따른 모의변압기의 HFPD 특성분석)

  • Kim, Duck-Keun;Im, Young-Sham;Lim, Jang-Seob;Moon, Chae-Joo;Lee, Jin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1957-1959
    • /
    • 2000
  • The PD measurement method is very useful to detect insulation degradation. Recently, the HFPD(High Frequency Partial Discharge) measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires in-service diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In this study, simulated transformer is manufactured and HFPD occurred from simulated transformer is measured with broad band antenna and active-line RF measurement system in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages. Also the PD pattern which was measured with EMC analyzer and RF measurement system is compared.

  • PDF

Electronic Structure of Pd(111) using Angle-Resolved Phothemission Spectroscopy (각분해 광전자 분광법을 이용한 Pd(111)의 전자구조 연구)

  • Hwang, Do-Weon;Kang, Jeong-Soo;Hong, Jae-Hwa;Jeong, Jae-In;Moon, Jong-Ho;Kim, Kun-Ho;Lee, Jeoung-Ju;Lee, Young-Pak;Hong, Soon-Cheol;Min, Byung-Il
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.1
    • /
    • pp.14-24
    • /
    • 1996
  • We have investigated atomic and electronic structures of a clean Pd(111) surface using low energy electron diffraction (LEED) and angle-resolved photoemission spectroscopy (ARPES). A typical clean LEED pattern with a 3-fold symmetry has been observed, corresponding to that for an fcc (111) surface. ARPES measurements have been performed along the $\Gamma-M,\Gamma-K,\Gamma-M$TEX> symmetry lines, from which the experimental band structure of Pd(111) has been determined. The experimental band structure and work function of Pd(111) surface are found to agree well with the calculated band structure of bulk Pd and the calculated work function of Pd(111), respectively. However, the peak positions in the experimental band structure are located closer to the Fermi level than in the theoretical band structure by 0.1~0.8 eV, depending on the $\kappa$-points in the Brillouin zone. In additin, the experimental band widths are narrower than the theoretical band widths by about 0.5eV. The effects of the localized surface Pd 4d states and the Coulomb interaction between Pd 4d bulk electrons have been discussed as possible origins of such discrepancies between experiment and theory.

  • PDF

Phase Equilibria of the System Pd-Sb-Te and Its Geological Implications (팔라듐-안티몬-테루르 계(系)의 상평형(相平衡)과 지질학적(地質學的) 의의(意義))

  • Kim, Won-Sa;Chao, George Y.
    • Economic and Environmental Geology
    • /
    • v.26 no.3
    • /
    • pp.327-335
    • /
    • 1993
  • Phase relations in the system Pd-Sb-Te were investigated at $1000^{\circ}$, $800^{\circ}$, and $600^{\circ}C$, using the sealed-capsule technique; the quenched products were studied by reflected light microscopy, X-ray diffraction, and electron microprobe analysis. At $1000^{\circ}C$, the solid phases Pd, $Pd_{20}Sb_7$, $Pd_8Sb_3$, $Pd_{31}Sb_{12}$, and $Pd_5Sb_2$ are stable with a liquid phase that occupies most of the isothermal diagram. Additional solid phases at $800^{\circ}C$ are $Pd_5Sb_3$, PdSb, $Pd_8Te_3$, $Pd_7Te_3$, and a continuous $Pd_{20}Te_7-Pd_{20}Sb_7$ solid solution becomes stable. At $600^{\circ}$, $PdSb_2$, $Pd_{17}Te_4$, $Pd_9Te_4$, PdTe, $PdTe_2$, $Sb_2Te_3$, and Sb and continuous PdSb-PdTe and $PdTe-PdTe_2$ solid solutions are stable. All the solid phases exhibit solid solution, mainly by substitution between Sb and Te to an extent that varies with temperature of formation. The maximum substitution (at.%) of Te for Sb in the Pd-Sb phases is: 44.3 in $Pd_8Sb_3$, 52.0 in $Pd_{31}Sb_{12}$, 46.2 in $Pd_5Sb_2$ at $800^{\circ}C$; 15.3 in $Pd_5Sb_3$, 68.3 in $PdSb_2$ at $600^{\circ}C$. The maximum substitution (at.%) of Sb for Te in the Pd-Te phases is 34.5 in $Pd_5Sb_3$ at $800^{\circ}C$, and 41.6 in $Pd_7Te_3$, 5.2 in $Pd_{17}T_4$, 12.4 in $Pd_9Te_4$, and 19.1 in $PdTe_2$ at $600^{\circ}C$. Physical properties and X-ray data of the synthetic $Pd_9Te_4$, PdTe, $PdTe_2$, $Pd_8Sb_3$, PdSb, and $Sb_2Te_3$ correspond very well with those of telluropalladinite, kotulskite, merenskyite, mertieite II, sudburyite, and tellurantimony, respectively. Because X-ray powder diffraction data consistently reveal a 310 peak ($2.035{\AA}$), the $PdSb_2$ phase is most probably of cubic structure with space group $P2_13$. The X-ray powder pattern of a phase with PdSbTe composition, synthesized at $600^{\circ}C$, compares well with that of testibipalladite. Therefore, testibiopalladite may be a member of the $PdSb_2-Pd(Sb_{0.32}Te_{0.68})$ solid solution series which is cubic and $P2_13$ in symmetry. Thus the ideal fonnula for testibiopalladite, presently PdSbTe, must be revised to PdTe(Sb, Te). Borovskite($pd_3SbTe_4$) has not been found in the synthetic system in the temperature range $1000^{\circ}-600^{\circ}C$.

  • PDF

Synthesis of Palladium Nanocubes/Nanorods and Their Catalytic Activity for Heck Reaction of Iodobenzene

  • Ding, Hao;Dong, Jiling
    • Applied Microscopy
    • /
    • v.46 no.2
    • /
    • pp.105-109
    • /
    • 2016
  • Palladium has been used as a catalyst not only in Suzuki and Heck cross coupling reaction in organic chemistry, but also in automobile industry for the reduction of vehicle exhausts. The catalytic activity of Pd nanoparticles depends strongly on their size and exposed crystalline facets. In this study, the single crystalline palladium nanocubes/nanorods were prepared in the presence of polyvinyl pyrrolidone (PVP) and potassium bromide (KBr) using the polyol method. Selected area diffraction pattern and high-resolution transmission electron microscopy (TEM) were performed by TEM. The result shows that the ratio of KBr/PVP is the key factor to determine whether the product is cubes or rods. The as-prepared Pd nanocubes were highly uniform in both size and shape. The ordered packing structures including monolayer and multilayer can be fabricated via the rate-controlled evaporation of solution solvent. The catalytic activity of these Pd nanocubes towards heck reaction of iodobenzene with acrylate or acrylic acid was found to be higher than that of Pd nanorods. We suspect it is caused by the difference of energy state while Pd nanocubes is {100} plane and nanorods is {111} plane.

A Comparative Study of The PD Pattern Analysis Based on PRPD and CAPD for The Diagnosis of Gas Insulated Transformer (GITr(Gas Insulated Transformer) 내부에 발생되는 PD 신호의 패턴분석을 위한 PRPD와 CAPD 적용결과 비교)

  • Jung, Seung-Yong;Koo, Ja-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.308-312
    • /
    • 2006
  • Partial Discharge (PD) phenomena occurred by different nature of insulating defects has been regarded as a random process by which Phase Resolved Partial Discharge Analysis(PRPDA) has been proposed and then commercially accepted for the diagnosis of the power apparatus since more than three decades. Moreover, for the same purpose, a novel approach based on the Chaotic Analysis(CAPD) has been proposed since 2000, in which Partial Discharge(PD) phenomena is suggested to be considered as a deterministic dynamical process. In this work, for the diagnosis of Gas Insulated Transformer(GITr), four different types of specimen were fabricated as a model of the possible defects that might possibly cause its sudden failures such as turn to turn insulation, inter coil insulation, free moving particle and protrusion. For this purpose, these defects are introduced into the Gas Insulated Transformer(GITr) mock-up and experimental investigations have been carried out in order to analyze the related Partial Discharge(PD) patterns by means of both Phase Resolved Partial Discharge Analysis(PRPDA) and Chaotic Analysis(CAPD) respectively and then their comparisons are made systematically.

A comparative study of the PD pattern analysis based on PRPD and CAPD for the diagnosis of Gas Insulated Transformer (GITr(Gas Insulated Transformer) 내부에 발생되는 PD 신호의 패턴분석을 위한 PRPD와 CAPD 적용 결과 비교)

  • Jung, Seung-Yong;Lim, Yun-Sok;Koo, Ja-Youn;Chang, Yong-Moo;Kang, Chang-Won;Lee, Yung-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2060-2062
    • /
    • 2005
  • Partial Discharge (PD) phenomena occurred by different nature of insulating defects has been regarded as a random process by which Phase Resolved Partial Discharge Analysis (PRPDA) has been proposed and then commercially accepted for the diagnosis of the power apparatus since more than three decades. Moreover, for the same purpose, a novel approach based on the Chaotic Analysis(CAPD) has been proposed since 2000, in which PD phenomena is suggested to be considered as a deterministic dynamical process. In this work for the diagnosis of GITr, four different types of specimen were fabricated as a model of the possible defects that might possibly cause its sudden failures such as turn to turn insulation, inter coil insulation, free moving particle and protrusion. For this purpose, these defects are introduced into the GITr mock-up and experimental investigations have been carried out in order to analyze the related PD patterns by means of both PRPDA and CAPD respectively and then their comparisons are made systematically.

  • PDF

Trend in UHF Technique for On-Line PD Monitoring of Transformer (변압기의 온라인 PD 모니터링을 위한 UHF 기술의 동향)

  • Oh, Yong;Yun, Ju-Ho;Kim, Yun-Seok;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.527-528
    • /
    • 2007
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of a 220kV transformer in a substation. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

The study of the c($2{\times}2$) ordered Mn surface alloy Pd(001)

  • Jung, J.W.;Kim, S.H.;Park, C.Y.;Seo, J.K.;Min, H.G.;Byun, D.H.;Kim, J.S.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.4 no.3
    • /
    • pp.68-72
    • /
    • 2000
  • We have deposited Mn on Pd(oon) at RT up to 30 ML. LEED pattern changed from p($1{\times}1$) to c($2{\times}2$) order below 0.5 ML Mn deposition. During Mn deposition, we have not found any changes in the peak position and the intensity of LEED I/V curve. Using LEED I/V curve analysis for each coverage, we found atomic structure and surface composition of c($2{\times}2$) ordered Mn alloy on Pd(001) surface. Above 1 Ml Mn, in the first layer the Mn subplane lies above the Pd subplane by 0.32 ${\AA}$. This result is very different from the earlier result of Jona et al., who contended that after annealing at 200 for 2 min, a buckled first layer with the Mn subplane lower than the Pd subplane by 0.2 ${\AA}$.

  • PDF

Design of Shape Memory Alloy Manipulator for Position Control (위치 제어를 위한 SMA(Shape Memory Alloy) 매니퓰레이터 설계)

  • Lee, Seung-Yeol;Yu, Seok-Jong;Yu, Byung-Gab;Han, Chang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.957-962
    • /
    • 2007
  • This paper describes a new mechanism for improving the force of actuators based on shape memory alloys (SMA) by increasing the number at which a coil pattern SMA spring can evenly be heated. This structure accomplishes a high efficient transformation between force and displacement overcoming the main mechanical drawback of shape memory alloys, that being the limit strain. A pantograph manipulator actuated by the introduced new mechanism has been designed for this research. Mechanical structure and driving mechanism of this manipulator are described in detail, and its control algorithm and current amplifier circuit in a position control system are designed.

  • PDF