• Title/Summary/Keyword: PD algorithm

Search Result 273, Processing Time 0.028 seconds

Comparison of Classification Rate Between BP and ANFIS with FCM Clustering Method on Off-line PD Model of Stator Coil

  • Park Seong-Hee;Lim Kee-Joe;Kang Seong-Hwa;Seo Jeong-Min;Kim Young-Geun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.138-142
    • /
    • 2005
  • In this paper, we compared recognition rates between NN(neural networks) and clustering method as a scheme of off-line PD(partial discharge) diagnosis which occurs at the stator coil of traction motor. To acquire PD data, three defective models are made. PD data for classification were acquired from PD detector. And then statistical distributions are calculated to classify model discharge sources. These statistical distributions were applied as input data of two classification tools, BP(Back propagation algorithm) and ANFIS(adaptive network based fuzzy inference system) pre-processed FCM(fuzzy c-means) clustering method. So, classification rate of BP were somewhat higher than ANFIS. But other items of ANFIS were better than BP; learning time, parameter number, simplicity of algorithm.

A Novel AE Based Algorithm for PD Localization in Power Transformers

  • Mehdizadeh, Sina;Yazdchi, Mohammadreza;Niroomand, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1487-1496
    • /
    • 2013
  • In this paper, a novel algorithm for PD localization in power transformers based on wavelet de-noising technique and energy criterion is proposed. Partial discharge is one of the main failures in power transformers. The localization of which could be very useful for maintenance systems. Acoustic signals due to a PD event are transient, irregular and non-repetitive. So wavelet transform is an efficient tool for this signal processing problem that gives a time-frequency demonstration. First, different wavelet based de-noising methods are analyzed. Then, a reasonable structure for threshold value determining and applying manner on signals is presented. Evaluated errors are good evidences for choices. Next, applying the elimination low energy frequency bands is discussed and developed as a de-noising method. Time differences between signals are used for PD localization. Different ways in time arrival detection are introduced and a novel approach in energy criterion method is presented. At the end, the quality of algorithm is verified through the different assays in lab.

Hybrid PD-Servo State Feedback Control Algorithm for Swing up Inverted Pendulum System

  • Nundrakwang, Songmoung;Benjanarasuth, Taworn;Ngamwiwit, Jongkol;Komine, Noriyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.690-693
    • /
    • 2005
  • In this paper, a hybrid PD-servo state feedback control algorithm for swing up inverted pendulum system is proposed. It consists of two parts. The first part is the PD position control for swinging up the pendulum from the natural pendent position to around the upright position and the second part is the servo state feedback control for stabilizing the inverted pendulum in upright position. The first controller is PD controller and it is tuned to control the position of the pendulum by moving the cart back and forth until the pendulum swings up around the upright position. Then the second controller will be switched to stabilize the inverted pendulum in its upright position. The controller in this stage is the servo state feedback controller designed by pole placement. Experimental results of PD type swinging up control system, of stabilizing servo state feedback control system and of the proposed hybrid PD-servo state feedback control system to swing up and stabilize inverted pendulum show that the proposed method is effective and reliable for actual implementation while it is simple.

  • PDF

Location of Partial Discharge in Power Transformer Using Ultrasonic Signal's Characteristic with Medium. (매질에 따른 초음파 신호의 특성을 이용한 변압기내 부분방전 위치 추정)

  • Seo, In-Chul;Kim, Young-No;Jeon, Young-Jae;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.136-138
    • /
    • 2000
  • This paper describes an efficient location detection algorithm for a partial discharge(PD) source in the transformer. The algorithm is previously proposed is not suitable for PD source detection because ultrasonic signal is diminished through the inner structure. In this paper, the proposal algorithm find PD source using geometry method and 3th sensor on the one side of transformer without diminution of ultrasonic signal. The proposed algorithm demonstrates the effectiveness and validity on model transformer.

  • PDF

Design of PD controller for WMR using a Neural Network

  • Kim, Kyu-Tae;Kim, Sung-Hee;Park, Chong-Kug;Bae, Jun-Kyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.180.5-180
    • /
    • 2001
  • This paper presents A Design of WMR Controller that being composed of cooperative relation between PID controller and optimized neural network algorithm, it operate a variable control by velocity. Some proposed algorithm in the past just depended on PID controller for the control of position of WMR but for more efficient control we design a variable controller that operate control by PD controller using neural network if it is satisfied with any given condition. it adjust gain of PD controller for real time control using a fast feedforward algorithm which is different with Form of the standard backpropagation algorithm.

  • PDF

An Application of NN on Off-line PD Diagnosis to Stator Coil of Traction Motor (견인전동기용 고정자 코일의 Off-line 부분방전 진단을 위한 NN의 적용)

  • Park, Seong-Hee;Lim, Kee-Joe;Kang, Seong-Hwa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.766-771
    • /
    • 2005
  • In this study, PD(partial discharge) signals which occur at stator coil of traction Motor are acquired these data are used for classifying the PD sources. NN(neural network) has recently applied to classify the PD pattern. The PD data are used for the learning process to classify PD sources. The PD data come from normal specimen and defective specimens such as internal void discharges, slot discharges and surface discharges. PD distribution parameters are calculated from a set of the data, which is used to realize diagnostic algorithm. NN which applies distribution parameters is useful to classify the PD patterns of defective sources generating in stator coil of traction motor.

Identification of Void Diameters for Cast-Resin Transformers (몰드변압기의 보이드 결함 크기 판별)

  • Jeong, Gi-woo;Kim, Wook-sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.570-573
    • /
    • 2022
  • This paper presents the identification of void diameters for a cast-resin transformer using an artificial neural network (ANN) model. A PD signal was measured by the Rogowski coil sensor which has the planar and thin structures fabricated on a printed circuit board (PCB), and the PD electrode system was fabricated to simulate a PD defect by a void. In addition, void samples with different diameters were fabricated by injecting air in a cylindrical aluminum frame using a syringe during the epoxy curing process. To identify the diameter of void defects, PD characteristics such as the discharge magnitude, pulse count, and phase angle were extracted and back propagation algorithm (BPA) was designed using virtual instrument (VI) based on the Labview program. From the experimental results, the BPA algorithm proposed in this paper has over 90% accurate rate to identify the diameter of void defects and is expected to use reference data of maintenance and replacement of insulation for cast-resin transformers in the on-site PD measurement.

  • PDF

Studies on control mechanism and performance of a novel pneumatic-driven active dynamic vibration absorber

  • Kunjie Rong;Xinghua Li;Zheng Lu;Siyuan Wu
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.117-127
    • /
    • 2023
  • To efficiently attenuate seismic responses of a structure, a novel pneumatic-driven active dynamic vibration absorber (PD-ADVA) is proposed in this study. PD-ADVA aims to realize closed-loop control using a simple and intuitive control algorithm, which takes the structure velocity response as the input signal and then outputs an inverse control force to primary structure. The corresponding active control theory and phase control mechanism of the system are studied by numerical and theoretical methods, the system's control performance and amplitude-frequency characteristics under seismic excitations are explored. The capability of the proposed active control system to cope with frequency-varying random excitation is evaluated by comparing with the optimum tuning TMD. The analysis results show that the control algorithm of PD-ADVA ensures the control force always output to the structure in the opposite direction of the velocity response, indicating that the presented system does not produce a negative effect. The phase difference between the response of uncontrolled and controlled structures is zero, while the phase difference between the control force and the harmonic excitation is π, the theoretical and numerical results demonstrate that PD-ADVA always generates beneficial control effects. The PD-ADVA can effectively mitigate the structural seismic responses, and its control performance is insensitive to amplitude. Compared with the optimum tuning TMD, PD-ADVA has better control performance and higher system stability, and will not have negative effects under seismic wave excitations.

Hybrid I-PD control for pneumatic cylinders with fuzzy theory

  • Inohana, Kenichiro;Fujiwara, Atsushi;Ishida, Yoshihisa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.193-196
    • /
    • 1996
  • A pneumatic cylinder has been used in the production facilities of various industries. However, it is difficult to achieve deciding the precise position of the piston rod, due to the nonlinear properties arising from the air compression and the friction. In recent years, the fuzzy control algorithm has been frequently applied to various kinds of systems on account of its simple algorithm, good adaptability to complex or nonlinear systems and so on. On the other hand, the PID or I-PD control has been used in many engineering fields because of the excellent performance. However, it is known that each one of them has disadvantages. In this paper, we propose a hybrid control which is strived to obtain the advantages of each other. It is shown that the proposed hybrid control performs better than the conventional I-PD control through the experimental results.

  • PDF

A GA based on-line tuning of robust minimax I-PD controller with penalty on manipulated variable

  • Kawabe, Tohru;Tagami, Takanori;Katayama, Tohru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.428-431
    • /
    • 1995
  • In this paper we propose an on-line tuning method by using genetic algorithm for robust minimax I-PD controller based on new criterion. The new criterion is the Integral of Squared Error (ISE) with a penalty of the derivative of manipulated variable. The work focuses on robust tuning of I-PD controller's parameters in the presence of plant parameter uncertainty. The result of several simulation studies are provided to illustrate the performance of this robust tunig method.

  • PDF