• 제목/요약/키워드: PD (Partial Discharge)

검색결과 501건 처리시간 0.038초

UV 투과율 향상 필터 기술을 이용한 전력설비 방전 검출용 자외선 코로나 카메라 개발 (Development of UV Corona Camera for the Detecting of Discharge on Power Facility using UV Transmittance Improvement Filter)

  • 김영석;최명일;김종민;방선배;송길목
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1656-1661
    • /
    • 2012
  • UV inspection technology is being used for predictive maintenance of power facility together with IR-thermography and ultrasonic devices. In this paper, the UV corona camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. The UV corona camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The transmission between 250 to 280nm was 11% ($12.5%{\times}88%{\times}98%$) by combing the transmission on absorption film, window and other filter(UG 5, nickel sulphate and so on). In a distance of 5m with the UV corona camera it is possible to detect partial discharge with a PD level of 2.5pC and a RIV level of $3.6dB{\mu}V$.

개질된 전력용 케이블절연체의 부분방전 특성 해석 (PD Characteristics Analysis of Improved Insulating Materials for Power Cables)

  • 송일근;곽희로
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권5호
    • /
    • pp.93-102
    • /
    • 1997
  • 본 논문은 성능이 우수한 전력케이블용 절연재료 개발에 대한 기초자료를 얻기 위한 연구로서, 초음파 센서를 사용하여 폴리에틸렌의 부분방전 특성을 측정하고 측정된 신호의 정량화를 시도하여 폴리에틸렌에서 발생되는 부분방전을 억제시킬 수 있는 방안에 관한 연구를 수행하였다. 이러한 결과로부터 기본 수지인 저밀도 폴리에틸렌을 적당히 개질하면 폴리에틸렌의 부분방전이 억제될 수 있음을 알았고, 이를 검증하기 위하여 폴리에틸렌을 아크릴산으로 개질하여 아크릴산 그라프트 폴리에틸렌을 제조하였으며, 이에 대한 부분방전 특성을 평가하였다. 평가결과, 본 연구에서는 아크릴산이 0.03 wt〔%〕정도 그라프트되면 폴리에틸렌의 부분방전이 크게 억제됨을 발견하였다. 이러한 결과로부터 폴리에틸렌을 적당한 화학성분으로 개질하면 폴리에틸렌의 부분방전이 크게 억제되었다.

  • PDF

22.9 kV XLPE 전력케이블에서 부분방전 측정을 위한 Planar Patch Sensor 설계 및 제작 연구 (A Study on the Design and Fabrication for Partial Discharge Measurement in 22.9kV XLPE Power Cable using Planar Patch Sensor)

  • 임광진;양상현;;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.265-266
    • /
    • 2008
  • The objective of this paper is to effectively detect partial discharges in XLPE power cables. In this field, we have been usually applied several sensors for such partial discharges. This study used a type of beyond compare antenna based on the influence of background noises. Also, we designed a new structure that is able to easily apply in the adhesion of planar patch types for XLPE power cables in measurement sensitiveness elevation. A high frequency simulation tool (CST-MWS) was applied to the antenna used in this study, and it was used to evaluate certain characteristics. We fabricated an antenna using the simulation data obtained from a specific test. After checking the sensitivity of this Planar Patch Sensor in the Lab, it was tested in an actual site. This paper analyzed the data as a part of time and frequency domain using an oscilloscope and spectrum analyzer, respectively.

  • PDF

22.9kV급 지중전력케이블의 부분방전 측정을 위한 평면루프센서 설계 및 제작 연구 (A Study on the Design and Fabrication for Partial Discharge Measurment in 22.9kV Underground Power Cable using Planar Loop Sensor)

  • 신동훈;임광진;;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.210-211
    • /
    • 2007
  • The objective of this paper is to effectively detect partial discharges in underground power cables. In this field, we have been usually applied several sensors for such partial discharges. This study used a type of beyond compare antenna based on the influence of background noises. Also, we designed a new structure that is able to easily apply in the adhesion of planar loop types for underground power cables in measurement sensitiveness elevation. A high frequency simulation tool (CST-MWS) was applied to the antenna used in this study, and it was used to evaluate certain characteristics. We fabricated an antenna using the simulation data obtained from a specific test. After checking the sensitivity of this Planar Loop Sensor in the Lab, it was tested in an actual site. This paper analyzed the data as a part of time and frequency domain using an oscilloscope and spectrum analyzer, respectively.

  • PDF

부분방전 패턴을 이용한 가교폴리에틸렌에서의 트리성장에 관한 연구 (The Study on tree growth in XLPE using PD patterns)

  • 강대용;오광영;신창면;박명섭;조규복;황보승;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.941-943
    • /
    • 1998
  • Exploitation of equipment with cross linked polyethylene (XLPE) insulation requires its condition monitoring and diagnostic. Traditionally diagnostics of insulation is carried out by means of partial discharge detection. Many researchers have developed a lot of methods to identify the defect by the PD form. However, such identification of a defect, for example, void, inclusion or treeing, does not say about its danger from a point of view of full insulation gap breakdown and insulation construction failure. The information about the form and size of formed upon high voltage treeing is necessary for prediction of the remained resource of XLPE insulation. For this purpose we carry out experimental research for determination of the dependencies between PD characteristics in XLPE upon time and three dimension PD patterns of corresponding treeing. The investigations were carried out by means of electrical measurement of PD current and simultaneous optical recording of treeing image. Test results show that the PD patterns can be applied for detecting tree growth well.

  • PDF

원자력발전소 전력케이블 부분방전 진단 사례 (PD Diagnosis of Power Cables for Nuclear Power Plant)

  • 한성흠;주광호;하체웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.804.1-805
    • /
    • 2011
  • 1980년대 건설된 국내 원자력발전소는 30년 정도의 운전 년수를 기록하고 있다. 가동연한의 증가에 따라 원자력발전소에 설치되어 있는 전력케이블은 열화진단 및 유지보수의 필요성이 증대되고 있다. 주기적 안전성 평가(Periodic Safety Review) 및 계속운전과 관련하여서도 고압케이블의 관리방안이 지속적으로 요구되고 있다. 본 논문에서는 원자력발전소에 설치되어 있는 13.8kV 고압케이블의 건전성을 확인하기 위하여 국내 최초 원자력발전소 운전 중 부분방전 진단을 수행하였다. 특히 측정장비별 특성 및 신뢰성을 제고하기위하여 Techimp사의 PD-Base I 장비와 OMICRON사 MPD600 장비 두가지를 가지고 케이블 부분방전(Partial Discharge; PD)열화진단을 수행 하였고 결과를 비교하였다.

  • PDF

폴리머 애자의 내전압 특성에 따른 부분방전 측정과 자외선 검출 (PD Measure and UV Detection in according to Withstand Voltage Characteristics of Polymer Insulator)

  • 송길목;김영석;김종서;정진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.76-77
    • /
    • 2008
  • The purposes of this paper ensure for the economical efficiency, accuracy, and good applications in domestic site set up the power installations. For the efficient conduct of these purposes, there are measured the partial discharge(PD) used by current probe and compared with detected signal of UV sensor. As the results, PD generated about 35% of breakdown voltage in polymer insulator. UV signal due to high voltage in polymer insulator is detected from about 1.7mV at 30kV to about 3mV at 70kV. Signal detected by ultra-sonic is increased at about 75% of breakdown voltage abruptly. It appears that error range is increased in boundary. UV sensor is needed must use from the practical and economical points of view.

  • PDF

VLF 및 HFCT-PD 장비를 이용한 원자력발전소 고압케이블 진단 방법 (Diagnostic Method of High Voltage Cable for Nuclear Power Plants using VLF and HFCT-PD Devices)

  • 하체웅;주광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2067-2068
    • /
    • 2011
  • 국내 원자력발전소에 설치되어 있는 고압케이블은 장기 운전에 따라 열화진단 및 유지보수의 필요성이 증대되고 있으며, 주기적 안전성 평가(Periodic Safety Review) 및 계속운전과 관련하여서도 고압케이블의 관리방안이 지속적으로 요구되고 있다. 본 논문에서는 원자력발전소에서 경년열화로 진단되어 철거된 케이블을 수거하여 VLF(Very Low Frequency) 장비를 사용하여 가압을 한 후 HFCT(High Frequency Current Transformer)를 이용한 부분방전(Partial Discharge ; PD) 측정을 수행하여 향후 원자력발전소 계획예방정비 시 케이블을 대상으로 Off-line 부분 방전 진단이 가능한지를 검토하였고, 그 결과를 기술하였다.

  • PDF

PSA를 이용한 PRPDA의 불명확성 개선에 대한 연구 (A study on the improvement of indefiniteness in PRPDA by use of PSA)

  • 이호근;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.226-228
    • /
    • 2003
  • This paper deals with the improvement of indefiniteness in PRPDA(Phase Resolved Partial Discharge Analysis) through analyzing the relation between PRPDA and PSA(Pulse Sequence Analysis). For the analysis we adopted PD data from artificial defects in XLPE HV cable systems and performed PRPDA and PSA. As a results, we confirmed that PSA was more useful than PRPDA in classifying PD patterns with the degradation stages. Therefore, it is possible to improve the indefiniteness of PD pattern recognition using the relation between PRPDA and PSA.

  • PDF

GIS PD검출을 위한 초광대역 UHF 커플러의 비교 연구 (A comparative study on UWB UHF couplers for GIS PD detection)

  • 이상화;최재구;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.207-210
    • /
    • 2003
  • 가스절연개폐장치(Gas-Insulated Switchgear, GIS) 내부에서 발생하는 부분방전(Partial Discharge, PD) 신호는 1ns이하의 상승시간(rising time)을 가지므로, 이 신호를 효과적으로 측정하기 위해서는 초광대역(Ultra Wide Band, UWB)특성을 갖는 커플러가 필요하다. 본 논문에서는 이러한 UWB 특성을 구현하기 위해, 대수주기 톱니형 평면 안테나(log-periodic toothed planar antenna)와 등각 스파이럴 패치안테나(equi-angular spiral patch antenna)형태의 두 가지 초광대역 UHF 커플러를 설계 제작하였다. 제작한 커플러들의 특성을 파악하기 위해 안테나의 급전부에, 자체 설계한 매칭 회로인 발룬(balun, balance to unbalance)을 장착하여, 반사계수, 모의펄스에 의한 검출신호, 스펙트럼 둥을 측정하였다.

  • PDF