• 제목/요약/키워드: PD (Partial Discharge)

검색결과 501건 처리시간 0.021초

부분방전 전계 측정용 $LiNbO_3$ 프루브 센서 제작 (A development of $LiNbO_3$ probe sensor for detecting partial discharge)

  • 강원종;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1041-1043
    • /
    • 1999
  • In this work, a possible new PD detection technique, based on the electro-optic effect, has been proposed. A proto-type probe sensor for detection partial discharge is made by $LiNbO_3$ Pockels cell, diachroic sheet polarizer and right-angle prism. The Mach-Zehnder interferometer system is proposed by using this sensor and this system is applied to detecting high electric field. we show the characteristic of the proto-type probe sensor and the design of a proposed probe type sensor.

  • PDF

prototype 패치 안테나를 이용한 고압 회전기의 부분방전 측정 연구 (PD Diagnosis on High Voltage Rotating by Using New Prototype Patch Antenna Sensor)

  • 키아우소 륀;신동훈;임광진;공태식;김회동;박노준;박대회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.169-171
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the HV Rotating Machine with the new prototype patch antenna sensor. In this study, we design new type of patch antenna based on microstrip technology and make many experiments of elaine testing compare with the existing HFCT and EM probe on stator winding of HV generator in the laboratory. This paper will mention comparison of experimental results based on the three kinds of sensors.

  • PDF

고주파 부분방전 시험을 위한 필터 설계 (Filter Design for Detecting High-Frequency Partial Discharge)

  • 안종현;윤주호;최용성;최충석;박대희;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.68-71
    • /
    • 2007
  • In this paper, we developed HPF (high pass filter) consisted of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke probe and oscilloscope (TDS-3054, Tektronix).

  • PDF

가스절연개폐장치 고장예방을 위한 UHF 부분방전 상시 감시 시스템 (On-line UHF partial discharge monitoring system for Gas- insulated switchgears (GIS))

  • 최재옥;김영노;황철민;이영상;박기준;구선근;윤진열;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2066-2068
    • /
    • 2005
  • We developed an on-line Ultra-high frequency partial discharge monitoring system to prevent a catastrophic failure of gas- insulated switchgears. The system has been tested in the laboratory for detection of various UHF PD signals. We also performed detection sensitivity verification tests and compared them with conventional IEC60270 method.

  • PDF

모의 GIS내에서의 부분방전시 UHF 안테나를 이용한 방전위치측정 (The measurement of a discharging point using UHF Antenna with partial discharge in the model GIS)

  • 장효성;박광서;이현철;김인식;최병주;최상태;김기채;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1806-1808
    • /
    • 2003
  • 본 논문은 모의GIS(내에서 부분방전(partial discharge:PD) 발생 시 방사되는 전자파 신호를 두 개의 UHF(Ultra-High Frequency)타임 혼형안테나(Time-Do main Antennas: NBS-200)를 설계제작하여 오실로스코프를 이용한 부분방전의 위치검출에 관해 연구하였다. 실험조건은 GIS내에 금속 파티클을 넣고 전압을 32[kV]로 고정하여 파티클의 활발한 진동시에 방사되는 전자파 신호를 오실로스코프를 사용하여 측정된 두 신호의 시간차를 이용하여 추정하였다.

  • PDF

지능형 배전기기를 위한 UHF 부분방전 센서 개발 (Development of UHF Partial Discharge Sensor for Intelligent distribution Facilities)

  • 조용준;황철민;김영노;최재옥;송일근;이병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.161-162
    • /
    • 2007
  • This paper is analyzed the internal type UHF sensors that be able to monitor the condition of the distribution facilities and the location selecting of that sensors. It set the PD cell on the inside of 22.9kV load switchgear and then it executed Partial Discharge test. it introduced the result of the test.

  • PDF

Experimental Investigation on Dielectric and Thermal Characteristics of Nanosized Alumina Filler Added Polyimide Enamel

  • Sugumaran, C. Pugazhendhi
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.978-983
    • /
    • 2014
  • The polymer nano composite possess good priority recently for engineering applications. Especially the electrical insulating materials attract the high performance of nano composites. In this work the ballmill synthesiation process of nano sized Alumina ($Al_2O_3$), the preparation of new nano composite material with an content of enamel and synthesized Alumina as 1wt%, 3wt% and 5wt%. Experimental investigation has been carried out for the prepared nano composites materials with respect to dielectric parameter measurements such as dielectric loss (tan ${\delta}$), dielectric constant (${\varepsilon}$), dielectric strength under various temperature. The partial discharge level also measured for all the samples and the PD inception voltage is also observed and compared. Weight loss of the material has been analyzed through TGA. It has been experimentally proved that 3wt% of Alumina nano filler added enamel has significant improvement in the dielectric and thermal properties.

변압기 부분방전 위치검출을 통한 진단알고리즘 개발 (Development of Diagnostic Algorithm Using Location of PD at Transformer)

  • 이승환;오학준;신승식;윤만수;정찬수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2178-2180
    • /
    • 2001
  • This paper is the study for the separating noise signal that is the greatest problem in ultrasonic signal measurement which is one of the method of estimation of partial discharge signals location. Because we can measure the number and location of signal, it is possible to distinguish between the signal of partial discharge and the external noise. Therefore, we can develop the credibility of detecting of insulating deterioration in transformer.

  • PDF

초음파센서를 이용한 GIS내 부분방전원의 식별 (Identification of partial discharge sources in GIS using AEsensor)

  • 이용희;이강원;이용희;신양섭;서정민;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.200-202
    • /
    • 2002
  • The use of ultrasound is proposed as the most economic and practical nondestructive test method for the detectin of electrical degradation in insulating materials. This paper has studied identification and characterization of partial discharge signals according to defects in GIS using AE(acoustic emission)sensor. Analysis of PD signals use $\psi-v-n$, skewness and kurtosis.

  • PDF

대형변압기 절연상태 평가 (Assessment of Insulation Condition in Large Transformers)

  • 김희동;공태식;이영준;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.499-502
    • /
    • 2004
  • In order to detect of insulation problems an early, transformer has to be performed the several tests. The ac current and tan6 of transformer winding insulation were investigated by Schering bridge. Partial discharge(PD) tests are used to evaluate the insulation condition of transformer. The moisture content measurement was conducted using RVM(recovery voltage meter). The RVM test can show that the problem is affecting the paper insulation of transformer. The value of moisture content was 2.3% in main transformer. The insulations of four transformers were judged to be in good condition.

  • PDF