• Title/Summary/Keyword: PD (Partial Discharge)

Search Result 501, Processing Time 0.031 seconds

A Study on the Ultrasonic Measurement of Partial Discharge (부분방전의 초음파 측정에 관한 연구)

  • Sun, J.H.;Ryoo, H.S.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1562-1564
    • /
    • 1994
  • In this paper, we describe that the acoustic PD detection is examined in the various structures and position shapes of sensors. We find that the acoustic waves rate the complexity in various structures and position shapes of sensors may reduce the complexity of the acoustic wave in the PD detection of transformers.

  • PDF

Detection and Location of Partial Discharge in Oil Filled Transformer

  • Lee, Seung-Whan;Oh, Hak-Joon;Chung, Chan-Soo;Yun, Man-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.98.3-98
    • /
    • 2001
  • The research for detecting of insulating deterioration in transformer has been studied from long ago. Analysis method of combustible gas, which is included in insulating oil, has been widely used in detection of transformer pre-fault detection due to the effectiveness of its method. Recently the fault effect of the large transformer is very critical in a power system, therefore the on-line monitoring and diagnostic system is needed. In addition, the more accurate method of detecting a Partial Discharge (PD) location should be developed. For preventive maintenance against discharge failures, it is important not only to detect the discharges, but also to accurately estimate their positions. However ...

  • PDF

A Life Prediction of Insulation Degradation Using Complex Sensing System (복합 감지 시스템을 이용한 부분방전의 절연열화 수명추정)

  • Kim, S.H.;Kim, J.H.;Park, J.J.;Choi, J.K.;Yoon, H.J.;Lee, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.348-350
    • /
    • 1997
  • Because of internal voids ininsulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation. We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. Finally using statically operator such as the center of gravity(G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF

Discrimination of Insulation Defects in a Gas Insulated Switchgear (GIS) by use of a Neural Network Based on a Chaos Analysis of Partial Discharge (CAPD)

  • Jung, Seoung-Yong;Ryu, Cheol-Hwi;Lim, Yun-Sok;Lee, Ja-Ho;Koo, Ja-Yoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.118-122
    • /
    • 2007
  • In this work, experimental investigation is carried out in order to design and fabricate the UHF sensor that is able to detect the partial discharges produced from 10 artificial defects introduced into the real scale 70kV GIS mock-up under high voltage within a well shielded room. As well, in order to verify the on-site applicability of our method, the newly proposed CAPD (chaos analysis of partial discharge) is combined with spectral analysis for identifying the nature of 10 artificial defects under investigation. The PD pattern recognition of each defect has been fulfilled by applying our ANN software. The result indicates that the recognition rate reaches up to 80% by the newly proposed method while the traditional PRPD analysis method allows us to obtain 41%. In consequence, it can be pointed out that the proposed method seems likely to be applicable to the real GIS at the site.

The Analysis and Diagnosis on Location of Partial Discharge in Underground Distribution Cable (지중 배전케이블 부분방전 위치추정 진단 및 분석)

  • Yoon, Ji-Sub;Kim, Woo-Bin;Yoon, Sung-Ho;Choi, Won;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1160-1161
    • /
    • 2015
  • In order to analyze and diagnosis on Location of partial discharge in underground distribution cable, partial discharges were measured using eletromagnetic sensors, oscilloscope, PDMS system at on-site underground multi-circuit switches. Throughout the analysis using 3-phase simultaneous pulse analysis and pulse polarity comparison of circuits, it is possible to separate noises and PD pulses and to find out the location of the pulses.

  • PDF

Aging Diagnosis of Model Coil of HV Induction Motor Using HFPD and Neural Networks (HFPD 및 신경회로망을 이용한 고압 유도전동기 모델코일 열화진단)

  • Kim, Deok-Geun;Im, Jang-Seop;Yeo, In-Seon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.361-367
    • /
    • 2002
  • Many failures in high voltage equipment are preceded by partial discharge activity. In this paper deals with the application of the high frequency partial discharge measurement technique in motorette. HFPD measurement is very effective method to detect the PD occurred in motorette which is the called name of test specimen for accelerating test of stator winding[1] In this study, CT type HFPD sensor is used to detect the partial discharges and a measured HFPD pattern is analyzed by fractal mathematics. The neural network algorithm is used to pattern recognition and ageing diagnosis. As a result of this study, the fractal dimensions are increased along to applied voltage and HFPD pattern recognition using neural network shown excellent recognition rate. Also, the ageing diagnosis of motorette has been Possible.

Om-site Application of External UHF PD Sensor for the Identification of Partial Discharge Location (UHF대역 PD신호검출에 의한 GIS 결함위치표정의 현장적용 연구)

  • Lee, Chang-R.;Hong, C.Y.;Yoon, C.Y.;Yoon, J.H.;Nam, G.C.;Lee, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1766-1768
    • /
    • 2004
  • This paper describes the prediction of location of PD signals in GIS using the difference in the measured time between first and second wave arrival by the external-type PD sensors. It is well accepted that the electromagnetic wave in GIS propagates at the velocity of $3{\times}10^8$m/s. Consequently, we could identify the location of PD with high accuracy. The experience at the fields and the problems for the judgment are also discussed in detail.

  • PDF

Feature Extraction Technique for Insulation Fault of High Voltage Motor Stator Winding (고압전동기 고정자권선의 절연결함에 대한 특징추출기법)

  • Park Jae-Jun;Lee Sung-Young;Mun Dae-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.976-983
    • /
    • 2006
  • Multi-resolution Signal Decomposition (MSD) Technique of Wavelet Transform has interesting properties of capturing the embedded horizontal, vertical and diagonal variations within an image in a separable form. This feature was exploited to identify individual partial discharge sources present in multi-source PD pattern, usually encountered during practical PD measurement. Employing the Daubechies wavelet, feature were extracted from the third level decomposed and reconstructed horizontal and vertical component images. These features were found to contain the necessary discriminating information corresponding to the individual PD sources and multi-PD soruces.

Partial Discharge Characteristics at a Internal Void Using a Pulse Superimposing Technique (펄스 중첩법을 이용한 내부 보이드에서의 부분방전 특성.)

  • Kang, Ji-Hoon;Shin, Doo-Sung;HwangBo, Seung;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1624-1626
    • /
    • 1997
  • In this paper, a new PD measurement technique of pulse superposition method was proposed in order to investigate both PD mechanism and phase related PD patterns. From the experimental results, we could find that the polarity and the phase angle of the superposed pulse take great effects on PD characteristics and these method make it possible to get the physical information which statistical approach can not give. We could conclude that the changes of PD characteristics in the void surrounded by polymers may be attributed to the injection of charge carriers thereby formation of space charge in the surface and/or the bulk of the polymer.

  • PDF

The analysis of field condition for GIS partial discharge using PD Counter (PD 카운터를 이용한 GIS 부분방전 현장조사결과 분석)

  • Jeong, Jae-Ki;Yoon, Si-Young;Moon, Jong-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.174-175
    • /
    • 2008
  • 초고압 변전소의 주요설비인 가스절연개폐장치(GIS: Gas Insulated Switchgear)의 신뢰도를 높이기 위해서는 절연체 내부에서 발생하는 부분방전을 사전에 진단하여 예방을 하는 것이 중요하다. 현재 이에 대한 진단장치 개발이 이루어지고 있으며 GIS On-line System 장치 및 휴대용 진단장비가 국내에서 제작되고 있으나 On-line System은 고가의 비용이 들고 휴대용 진단장비는 상시감시가 어렵다는 단점을 가지고 있다. 이러한 단점을 보완하기 위해서 본 연구내용에서는 저가이면서 상시 PD 감시능력을 가진 PD 카운터에 대해 설명하고 GIS 현장에 실제 적용한 자료와 휴대용 진단장비와 함께 비교 적용한 자료를 가지고 PD 카운터의 특성을 확인하는데 역점을 두었다.

  • PDF