Characteristics of Contamination and Fate for PCDD/Fs in Ambient Air, Cheongju (청주지역 대기 중 PCDD/Fs 오염특성 및 거동)

  • Kim, Kyoung-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.294-299
    • /
    • 2009
  • To investigate the pollution levels and behavior of PCDD/Fs in ambient air, gaseous and particulate phase concentrations were measured at Cheongju city in 2008. The samples were collected at 3 sites (industrial, residential/commercial and rural region) by season (winter, spring and summer). The concentrations and TEQ concentrations of PCDD/DFs ranged from 0.73 to 2.43 pg/$m^3$ and from 0.007 to 0.122 pg TEQ/$m^3$, respectively. These levels were similar or lower than that of other domestic researches (from n.d. to 2.149 pg TEQ/$m^3$). The concentration of PCDD/Fs in particulate phase (from 54% to 98% against total concentration) were higher than that of gas phase. As a results of comparison of congener patterns and statistical analysis, PCDD/Fs was mainly influenced by a combustion process in ambient air, Cheongju city.

Distribution characteristics of dioxin concentration in pyrolysis-gasification-melting process facilities (생활폐기물 열분해-가스화-용융공정시설에서 다이옥신의 분포특성)

  • Son, Jihwan;Kim, Kiheon;Kang, Youngyeol;Park, Sunku
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.10-16
    • /
    • 2007
  • This research was designed to investigate the formations of hazardous air pollutants in the MSWs pyrolysis-gasification-melting process. In this survey, PCDDs/PCDFs (polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofuran) were investigated in the two facilities (A and B facilities). In A facility, the PCDDs/DFs concentrations were 0.88, 2.29, 0.16 ng I-TEQ/$m^3$ respectively on the secondary incinerator, boiler and stack. In B facility, the PCDDs/PCDFs concentrations were 0.22, 0.05 ng I-TEQ/$m^3$ respectively on the pyrolysis-gasification-melting furnace and stack. The concentrations of PCDDs/PCDFs increased due to resynthesis during cooling process in the both facilities. High concentrations of PCDDs/PCDFs isomers were founded as 2, 3, 4, 7, 8-PeCDF, 2, 3, 4, 6, 7, 8-HxCDF and 1, 2, 3, 6, 7, 8-HxCDF orderly in A facility, and 2, 3, 4, 7, 8-PeCDF, 1, 2, 3, 7, 8-PeCDD and 2, 3, 4, 6, 7, 8-HxCDF orderly in B facility.

Characteristics of organic pollutants in discharged industrial waste in Korea - Focuse on metallic and plastic manufacturing processes and wastewater treatment plants - (국내 사업장 폐기물 중 유기오염물질의 배출특성 연구 - 금속과 플라스틱 제조공정 및 폐수처리시설 중심으로 -)

  • Yeon, Jin-Mo;Kang, Young-Yeul;Kim, Woo-Il;Shin, Sun-Kyoung;Jeong, Seong-Kyeong;Cho, Yoon-A;Kim, Na;Kim, Min-Sun
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.421-428
    • /
    • 2012
  • In this study, PCDD/PCDFs, PAHs and PCBs in wastes from metal, plastic and wastewater treatment facilities were analyzed. The concentrations of PCDD/PCDFs ranged from 7.37~432.20 ng-TEQ/kg in fly ash, 0.51~855.01 ng-TEQ/kg in incinerated ash and 0.37~385.81 ng-TEQ/kg in dust. Dioxin content was lower, compared to data in foreign countries. PAHs concentration was in the range of 0.0075~2.9225 mg/kg for process sludge and 0.0035~1.6716 mg/kg for wastewater sludge, which satisfied all of the two standards (Nap, Ant, B(a)F:4/0.8, Phen, B(a)A:5/1, Flt:10/2.5, B(a)P:4.5/0.9) of the Marine Environment Management Act. PAHs concentration in process sludge and wastewater sludge were slightly lower than those abroad. According to the analysis of seven types of PCBs (in comparison with the first standard, 0.15 mg/kg), concentration was found in the range of 0.0~0.65 mg/kg, while PCB-52, PCB-101, PCB-138, PCB-153 and PCB-180 isomers were detected in excessive value in some machine oil and hydraulic fluid.

A Temporal Trend of Dioxins Levels in Environmental Media

  • Park, Kyunghee;Daeil Kang;Junheon Youn;Lee, Choong;Sunghwan Jeon;Jingyun Na
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.148-148
    • /
    • 2003
  • This study is to investigate the environmental levels and trend of dioxins, which was the 3$\^$rd/ year of environmental monitoring research for endocrine disrupting chemicals since 1999. Total 282 samples were analyzed from 115 sites including 26 sites of airs, 43 sites of waters, 11 sites of sediments and 35 sites of soil, which were the same as those of investigated sites in 2000. Sampling period was from June 2001 to June 2002. Target chemicals were seventeen species of 2,3,7,8-chlorine-substituted PCDD and PCDF congeners and were analyzed by the standard methods, established by National Institute Environmental Research (NIER). The average concentration of dioxins in air decreased from 0.324 pg-TEQ/N㎥ in 2000 to 0.287 pg-TEQ/N㎥ in 2001, and those in water and soil were 0.073pg-TEQ/L and 1.703pg-TEQ/dry g, respectively, which was the less values detected in 2000. In sediment, however, the value was 0.086pg-TEQ/dry g, which was the increase from the value of the year 2000. The concentration range of dioxins in air for 26 sites in 17 regions detected were 0.013∼l.664pg-TEQ/N㎥, 4 sites from those were exceeded the Air Quality Standards of Dioxin in Japan (0.6 pg-TEQ/N㎥). The tolerable daily intake of dioxins was calculated at the highest level (1.664) in air, with referring the soil and food data from Japan, was calculated to be 2.85pg-TEQ/kg/day, which was below the level of 4 pg-TEQ/kg/day suggested in KFDA(Korea). While the average concentration of dioxins in 15 big cities was 0.190 pg-TEQ/N㎥, that in 8 medium/small cities constituting an industrial complex was 0.558 pg-TEQ/N㎥. In water, the concentration range detected were 0∼0.946pg-TEQ/L and the trend of the average concentrations shows an increase from those of 1999 but decreased from those of 2000, any sites however were not exceeded the Water Quality Standards of Dioxin in Japan (1 pg- TEQ/L). In soil. the detected range were 0∼43.333 pg-TEQ/dry g and the average concentration decreased, compared with the results of 2000. According to the monitoring results by land utilization, the detected range were 0∼43.333pg-TEQ/dry g in farmland, 0.017∼0.601 pg-TEQ/dry g in the industrial area, 0.005∼0.049pg-TEQ/dry g in the park and 0.008∼1.825 pg-TEQ/dry g in the rest. In sediment, the detected range increased from 0∼0.244 pg-TEQ/dry g to 0∼0.537 pg-TEQ/dry g, based on the results of 2000. For the proper control of dioxins, continuous monitoring needs to be performed and in addition, the dioxin inventory should be prepared for major sources through the dioxin emission survey. These results would provide sound and solid basis for proper decision making of dioxins management like establishment of environmental quality standards in Korea.

  • PDF

Study on the Formation of Byproducts and the Decomposition of o-Chlorophenol by Addition of NaOH in Supercritical Water (초임계수 중에서 NaOH 첨가에 의한 o-chlorophenol의 분해 및 부산물 생성에 관한 연구)

  • Song, Byung-Joo;Kim, Jong-Guk;Lee, Geun-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.273-279
    • /
    • 2005
  • The degradation of o-chlorophenol(o-CP) in the presence of NaOH and the byproducts formed were investigated in a supercritical water(SCW) destruction process. The conversion of o-CP in the absence of NaOH was less than 20%, however it showed 100% conversion in the presence of NaOH(mole ratio[NaOH]/[o-CP] over than 2) with a residence time of less than 1 second. The formation of PAHs and the phenolic compounds formed were decreased in the presence of NaOH. The results revealed that the formation of byproducts during the destruction of o-CP in SCW was effected by the addition of NaOH. Phenol, cresols, chlorinated phenols, PAHs, p,p'-dihydroxybiphenyl and oxygenated polyaromatic compounds such as 1-indanone, dibenzofuran and dibenzo-p-dioxin were detected in both conditions(presence and absence of NaOH). At the same time, in the presence of NaOH, 2-ethylphenol, o-hydroxyacetophenone, hydroquinone, 4-allylphenol, 3-phenoxyphenol and 4,4'-oxybisphenol were also detected. The observed results suggest that the destruction of o-CP in SCW with NaOH occurs through a number of complicated reaction pathways. Dibenzofuran and dibenzo-p-dioxin were also detected during destruction of o-CP by SCW. The above observation suggests that there may be a common relationship between the thermal incineration process and SCW decomposition process.

Evaluation of accuracy for measurement of Dioxins (PCDDs/PCDFs) by using certified reference material (CRM) (인증표준물질(Certified reference materials, CRM)을 이용한 이옥신류(PCDDs/PCDFs) 측정의 정확도 평가)

  • Youn, Yeu Young;Park, Deok Hie;Lim, Young Hee;Cho, Hye Sung
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.376-385
    • /
    • 2009
  • In our study, the accuracy for measurement of seventeen 2,3,7,8-substituted PCDDs/PCDFs in certified reference material (CRM) which is the sample of homogeneous sediment matrix taken from an area known to have significant chemical contamination, particularly PCBs (polychlorinated biphenyls), was evaluated. Though the methodology in this study followed the official method of unintentionally produced persistent organic pollutants (UPOPs) announced by the Ministry of Environment of the Republic of Korea in 2007, there were slight changes using additional purification step by activated carbon column because the interferences of sample were not sufficiently removed when only multi-silica column and alumina column have been used for purification. The |En| number proposed by the Korea Research Institute of Standards and Science was used for a valuation basis of the accuracy. The |En| numbers of seventeen 2,3,7,8-substituted PCDDs/PCDFs have been indicated as 1 and below, they were decided "Pass" in this test, when DB-5MS column and SP-2331 column were used together. Because 1,2,3,7,8-PeCDD and #169-HxCB were not separated on DB-5MS column, the ions of 1,2,3,7,8-PeCDD were selected at M/M+2 instead of M+2/M+4 suggested by EPA 1613. It is possible to distinguish them in HRGC/HRMS analysis.