• Title/Summary/Keyword: PCDD

Search Result 77, Processing Time 0.027 seconds

Slagging treatment of MSW incineration ash by plasma system (플라즈마를 이용한 도시 쓰레기 소각재 용융처리 기술)

  • 박현서;지규일;장준섭;전석구;배희주;김형진;이시창;주성준;신범수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.65-68
    • /
    • 1999
  • A plasma melting system to vitrify ny ash from MSW(Municipal Solid Waste) incinerator has been operated in SHI(Samsung Heavy Industries) since 1996. Waste feeding rate was 200kg/hr. with maximum working power of 500㎾. Because of high melting temperature of fly ash, bottom ash was used as an additive to decrease melting temperature. Data analysis for discharged slag shows volume reduction up to 30% and no leaching of heavy metals such as Pb, Cd, Cr which were an obstacle for landfill and recycle. Atmospheric pollution gas like nitrogen oxides, carbon monoxide, and PCDD/PCDF were restrained below the regulatory limit.

  • PDF

The Study of distribution relationship of dioxin isomers in some environmental matrix (몇 가지 환경 시료 중에 함유된 다이옥신류 이성질체들의 분포에 대한 상관성 연구)

  • Kim, Yunje;Jun, Myung Yoon
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.419-424
    • /
    • 2005
  • In recent years, dioxins which were designated as persistent organic pollutants and endocrine disrupters are treated as substance of environmental pollution and studied about human health risk assessment, emission pollutants estimation, analytical methods and so on. It is easy that dioxins are accumulated to soil because of the atmosphere circulation of burning up the waste. This is the comparative studies on the distribution relationship of dioxin isomers in exhausted gas of industrial waste and urban waste incinerators, ambient air and soil. A basis of PCDDs and PCDFs based on OCDD was drawn up to the curve and they correspond to dioxin isomers in exhausted gas of industrial waste and urban waste incinerators and ambient air. On comparing these results, It was found that the ambient air and exhausted gas of industrial waste incinerators were very similar in curve and ratio. Consequently, environmental by exposed dioxin depends on the exhausted gas of industrial waste incinerators than urban waste incinerators. In case of soil, even though we can not completely rule out the possibility of pollution source bring on pesticide and other factors, and naturally biological dissociations, the curve shape is very similar to exhausted gas of industrial waste incinerators and ambient air. So, we inform here that it was mainly caused by these environmental factors.

Residue and Risk Assessment of Polychlorinated dibenzo-p-dioxin/dibenzofurans in the Korean Population (다이옥신류에 의한 한국인의 폭로 현황 및 리스크 평가)

  • Kang, Youn-Seok;Park, Jong-Sei;Min, Byung-Yoon
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.270-286
    • /
    • 2002
  • The human adipose and milk samples analyzed in this study were collected at hospitals in Seoul, Masan and Jinju. The mean values of International Dioxin Toxic Equivalents (I-TEQ) of PCDDs and PCDFs in human adipose samples from the three regions were calculated as 9 pg I-TEQ/g(0.2 ~ 30 pg TEQ/g, lipid weight basis) and 8 pg I-TEQ/g (0.8 ~ 25 pg TEQ/g), respectively. The residue levels of PCDDs-TEQ and PCDFs-TEQ in human milk collected from Masan were 13 pg I-TEQ/g (lipid wt.) and 4.8 pg I-TEQ/g, respectively. On the whole, the contamination levels of these compounds in the Korean population were lower than those in the other countries. Based on the analytical data and assuming a daily intake consumption of 800 mL milk with 3% fat, the average daily intake of PCDDs/DFs via human milk for a baby weighing 5 Kg could be calculated. The daily intake of PCDDs/DFs via breast-feeding was estimated to be 39 pg/kg body weight/day for 2,3,7,8-TeCDD and 86 pg/kg/day for TEQ. These levels are far above all virtually safe dose(VSD) or tolerable daily intake(TDI) values proposed by health authorities in various countries, ranging from 0.001(US EPA) to 4 pg/kag/day (WHO).

Optimal Operation of Medium Sized Incinerator to Minimize PCDD/Fs Emission (중형 소각로 다이옥신 배출 저감을 위한 최적 운전인자)

  • Yoo, Dong-Joon;Koo, Ja-Kong;Jeong, Seung-Ik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.4
    • /
    • pp.44-49
    • /
    • 2013
  • An establishment of dioxin-reduction operating skill for medium sized incineration facility is urgently needed in Korea with nearly 90% of medium sized incineration. Using lattice stoker incineration processing the capacity of 20 tons industrial general waste per day, similar properties of the household waste, dioxin-reduction is derived in optimum operating condition and parameters. As a result, CO haunting which is the minimization of frequency is found as the major parameter to minimize dioxin.

PCDD/Fs Levels and Congener Pattern Characteristics in Stack Gas and Fly Ash from Waste Incinerators, Environmental Media, Food, and Human Tissues: An Overview (국내 폐기물소각시설 배출가스와 소각재, 환경 매질, 식품 및 인체에서 검출된 다이옥신 농도수준 및 이성질체 유형 특성)

  • Kim Su-Jin;Park Soyoung;Choi Seung-Pil;Lee Dong Soo
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.1
    • /
    • pp.1-24
    • /
    • 2004
  • Since dioxins became a serious concern in Korea, a significant number of investigations have been conducted to address diverse issues related to dioxins. However, the results have not been organized for ready access and use. The principal purposes of the work were to ⅰ) provide an archive of dioxin researches in Korea and ⅱ) give an overview of dioxin contamination. The focus of this work was placed on the contamination levels and characteristics concerning the waste incinerators emissions, environmental media, and biological samples(fishes/shellfishes, foods, and human body). Principal component analysis was conducted to identify common and/or unique features and the important variables associated with the congener patterns. From a comprehensive search of academic journals, research and monitoring project reports, dissertations, and periodicals of other forms, a total of 115 counts were found that met the purposes of this study. The contamination levels of various samples were summarized and compared to those reported in foreign literatures. The congener patterns varied largely with environmental media and distinguished particularly by OCDD, 1,2,3,4,6,7,8-HpCDF, and OCDF for the samples within the same media. The proximity to emission sources differentiated the congener patterns in air and soil samples by the fraction of OCDD.

Analysis of PCDDs/PCDFs in Sediment by Isotope Dilution HRGC/HRMS (Isotope Dilution HRGC/HRMS 방법을 이용한 저니토중의 PCDDs/PCDFs 분석)

  • Jang, Seong Ki
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.789-801
    • /
    • 2000
  • This analysis was conducted for PCDDs/PCDFs in sediment by isotope dilution HRGC/HRMS method. From the result, the mean recovery of surrogate standard was in the range of 70.1-80.8%. Among the distribution of 2, 3, 7, 8-substituted isomers, the concentration of OCDD represented almost 40.6-78.5% of total concentration and that of OCDF showed 6.6-14.7% and 1, 2, 3, 4, 6, 7, 8-HpCDD showed 5.1-7.7%. The portion of PCDDs represented 62.4-86.9% of total PCDDs/PCDFs. In the TEQ concentration 1, 2, 3, 4, 7, 8-PeCDF concentration represented 22.7-35.6 % of total TEQ concentration.

  • PDF

Disposal of Polychlorinated Biphenyls(PCBs) by a Combined Chemical with Thermal Treatment (화학 및 열적 처리를 이용한 폴리염화바이페닐(PCB)의 제거)

  • Ryoo, Keon Sang
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.3
    • /
    • pp.286-293
    • /
    • 1999
  • A comnprehensive process which combines chemical with thermal treatment by controlled counterflow oxidation has been developed for disposal of PCBs in transformer oil. PCBs which not completely removed by chemical treatment, after being filtered with appropriate adsorbent during the oil circulations, was thermally treated. Destruction efficiencies of better than 99.99% was obtained, with no measurable formation of PCDDs (polychlorinated dibenzo-p-dioxins) or PCDFs (polychlorinated dibenzofurans). The combination also permits high recovery of oil and inorganic supports from scrap power transformers. The process is environmentally benign, easy to use and less capital intensive than other available technologies.

  • PDF

Estimation of PCDDs/PCDFs Intake for Korean Children and Their Mothers Through Daily Foods (음식물을 통한 어린이와 그들의 어머니에 대한 PCDDs/PCDFs 섭취량 평가)

  • Moon, Chan-Seok;Paik, Jong-Min
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.11-15
    • /
    • 2007
  • This study was performed to evaluate the congeners of polychlorinated dibenzo-p-dioxins(PCDDS) and polychlorinated dibenzofurans(PCDFs) in Korean foods among children in Korea, in comparison with the findings in their mothers. The PCDDs and PCDFs intakes of 24-h diet duplicates were estimated from the previous Korean reports. In Korean children and their mothers of this study, major sources of lipid intake were plant-based foods(62% for children, 66% for their mothers). The women took 34% of lipid from animal sources, among which meats were leading sources of animal lipids(30%). Fish and shellfish were accounted for 4% in total lipid intake. Daily intake of PCDDs and PCDFs in the children md their mothers were 0.002-3.188 and 0.002-2.717 pg WHO-TEQ/day in animal sources and ND-0.283 and ND-0.296 pg WHO-TEQ/day in plant sources, respectively. PCDDs/PCDFs intake from animal origin was the major exposure source for both children and their mothers in Korea. Among the 17 PCDD/Fs congeners, 2,3,4,7,8-pentachlorodibenzofuran was assumed to be the effective exposure marker for diet intake.

Optimized Design of Dioxin Analysis for Water Sample

  • Choi, Jaewon;Lee, Jaehee;Kim, Kyoungsim;Kim, Sunheong;Bae, Kyunghee
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.219-229
    • /
    • 2005
  • The analytical methods for dioxins in water sample from wastewater to tap water were reviewed. For extraction method, liquid-liquid extraction (LLE) has been widely used, however, this process needs too much time and man power. New approach including solid phase extraction (SPE) is now applicable to large volume of water sample with high extraction efficiency. Column clean up in classical analytical methods were very complex and time consuming procedures during decade. Modifications were tried to decrease solvent and reagents volume. Moreover, use of column connection method has been demonstrated in the environmental matrices. Instrumental configurations also have been improved, in which GC/MS/MS with large volume injection approach can analyze picogram levels. Absolute sensitivities of HRMS increased compared to old versions of double focusing sector type mass spectrometers. Based on these analytical evolutions during last 10 years, we tried to optimize the analytical method for dioxins in water sample from sample extraction to instrumental analysis.

Analysis of 2,3,7,8-substituted PCDDs, PCDFs, and DL-PCBs in muscle of crucian carp (Carassius auratus and Carassius cuvieri) from major rivers and lakes (주요 하천 및 호수에 서식하는 붕어 (Carassius auratus and Carassius cuvieri) 근육에 축적된 2,3,7,8-치환 PCDDs, PCDFs 및 DL-PCBs 분석)

  • Jeong, Gi-Ho;Moon, Ji-Yong;Moon, Dong-Ho
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.484-492
    • /
    • 2011
  • Bioaccumulation status and distribution characteristics of PCDDs, PCDFs and DL-PCBs in cruian carp collected from the four representative sites of major river systems in Korea were investigated. The recovery rates of PCDDs and PCDFs ranged from 50.6% to 88.3%, and those of DL-PCBs ranged from 52.3% to 93.2%. The mean, median and concentration range of ${\sum}$dioxins, which represents the total concentratons of PCDDs, PCDFs and DL-PCBs accumulated in the muscle of crucian carp, were 0.39, 0.14 and 0.047-1.0 pg TEQ/g wet wt., respectively. DL-PCBs were detected above the detection limit from all the samples, whereas PCDDs and PCDFs were detected from limited crucian samples. The relative contribution of DL-PCBs to ${\sum}$dioxins was remarkably larger than those for PCDDs and PCDFs. The percent contribution was 83.6% for DL-PCBs, and followed by 12.7% and 3.7% for PCDFs and PCDDs, respectively.