Characteristics of organic pollutants in discharged industrial waste in Korea - Focuse on metallic and plastic manufacturing processes and wastewater treatment plants - (국내 사업장 폐기물 중 유기오염물질의 배출특성 연구 - 금속과 플라스틱 제조공정 및 폐수처리시설 중심으로 -)

  • Yeon, Jin-Mo;Kang, Young-Yeul;Kim, Woo-Il;Shin, Sun-Kyoung;Jeong, Seong-Kyeong;Cho, Yoon-A;Kim, Na;Kim, Min-Sun
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.421-428
    • /
    • 2012
  • In this study, PCDD/PCDFs, PAHs and PCBs in wastes from metal, plastic and wastewater treatment facilities were analyzed. The concentrations of PCDD/PCDFs ranged from 7.37~432.20 ng-TEQ/kg in fly ash, 0.51~855.01 ng-TEQ/kg in incinerated ash and 0.37~385.81 ng-TEQ/kg in dust. Dioxin content was lower, compared to data in foreign countries. PAHs concentration was in the range of 0.0075~2.9225 mg/kg for process sludge and 0.0035~1.6716 mg/kg for wastewater sludge, which satisfied all of the two standards (Nap, Ant, B(a)F:4/0.8, Phen, B(a)A:5/1, Flt:10/2.5, B(a)P:4.5/0.9) of the Marine Environment Management Act. PAHs concentration in process sludge and wastewater sludge were slightly lower than those abroad. According to the analysis of seven types of PCBs (in comparison with the first standard, 0.15 mg/kg), concentration was found in the range of 0.0~0.65 mg/kg, while PCB-52, PCB-101, PCB-138, PCB-153 and PCB-180 isomers were detected in excessive value in some machine oil and hydraulic fluid.

Slagging treatment of MSW incineration ash by plasma system (플라즈마를 이용한 도시 쓰레기 소각재 용융처리 기술)

  • 박현서;지규일;장준섭;전석구;배희주;김형진;이시창;주성준;신범수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.65-68
    • /
    • 1999
  • A plasma melting system to vitrify ny ash from MSW(Municipal Solid Waste) incinerator has been operated in SHI(Samsung Heavy Industries) since 1996. Waste feeding rate was 200kg/hr. with maximum working power of 500㎾. Because of high melting temperature of fly ash, bottom ash was used as an additive to decrease melting temperature. Data analysis for discharged slag shows volume reduction up to 30% and no leaching of heavy metals such as Pb, Cd, Cr which were an obstacle for landfill and recycle. Atmospheric pollution gas like nitrogen oxides, carbon monoxide, and PCDD/PCDF were restrained below the regulatory limit.

  • PDF

The Study of distribution relationship of dioxin isomers in some environmental matrix (몇 가지 환경 시료 중에 함유된 다이옥신류 이성질체들의 분포에 대한 상관성 연구)

  • Kim, Yunje;Jun, Myung Yoon
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.419-424
    • /
    • 2005
  • In recent years, dioxins which were designated as persistent organic pollutants and endocrine disrupters are treated as substance of environmental pollution and studied about human health risk assessment, emission pollutants estimation, analytical methods and so on. It is easy that dioxins are accumulated to soil because of the atmosphere circulation of burning up the waste. This is the comparative studies on the distribution relationship of dioxin isomers in exhausted gas of industrial waste and urban waste incinerators, ambient air and soil. A basis of PCDDs and PCDFs based on OCDD was drawn up to the curve and they correspond to dioxin isomers in exhausted gas of industrial waste and urban waste incinerators and ambient air. On comparing these results, It was found that the ambient air and exhausted gas of industrial waste incinerators were very similar in curve and ratio. Consequently, environmental by exposed dioxin depends on the exhausted gas of industrial waste incinerators than urban waste incinerators. In case of soil, even though we can not completely rule out the possibility of pollution source bring on pesticide and other factors, and naturally biological dissociations, the curve shape is very similar to exhausted gas of industrial waste incinerators and ambient air. So, we inform here that it was mainly caused by these environmental factors.

Residue and Risk Assessment of Polychlorinated dibenzo-p-dioxin/dibenzofurans in the Korean Population (다이옥신류에 의한 한국인의 폭로 현황 및 리스크 평가)

  • Kang, Youn-Seok;Park, Jong-Sei;Min, Byung-Yoon
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.270-286
    • /
    • 2002
  • The human adipose and milk samples analyzed in this study were collected at hospitals in Seoul, Masan and Jinju. The mean values of International Dioxin Toxic Equivalents (I-TEQ) of PCDDs and PCDFs in human adipose samples from the three regions were calculated as 9 pg I-TEQ/g(0.2 ~ 30 pg TEQ/g, lipid weight basis) and 8 pg I-TEQ/g (0.8 ~ 25 pg TEQ/g), respectively. The residue levels of PCDDs-TEQ and PCDFs-TEQ in human milk collected from Masan were 13 pg I-TEQ/g (lipid wt.) and 4.8 pg I-TEQ/g, respectively. On the whole, the contamination levels of these compounds in the Korean population were lower than those in the other countries. Based on the analytical data and assuming a daily intake consumption of 800 mL milk with 3% fat, the average daily intake of PCDDs/DFs via human milk for a baby weighing 5 Kg could be calculated. The daily intake of PCDDs/DFs via breast-feeding was estimated to be 39 pg/kg body weight/day for 2,3,7,8-TeCDD and 86 pg/kg/day for TEQ. These levels are far above all virtually safe dose(VSD) or tolerable daily intake(TDI) values proposed by health authorities in various countries, ranging from 0.001(US EPA) to 4 pg/kag/day (WHO).

Analysis of PCDDs/PCDFs in Sediment by Isotope Dilution HRGC/HRMS (Isotope Dilution HRGC/HRMS 방법을 이용한 저니토중의 PCDDs/PCDFs 분석)

  • Jang, Seong Ki
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.789-801
    • /
    • 2000
  • This analysis was conducted for PCDDs/PCDFs in sediment by isotope dilution HRGC/HRMS method. From the result, the mean recovery of surrogate standard was in the range of 70.1-80.8%. Among the distribution of 2, 3, 7, 8-substituted isomers, the concentration of OCDD represented almost 40.6-78.5% of total concentration and that of OCDF showed 6.6-14.7% and 1, 2, 3, 4, 6, 7, 8-HpCDD showed 5.1-7.7%. The portion of PCDDs represented 62.4-86.9% of total PCDDs/PCDFs. In the TEQ concentration 1, 2, 3, 4, 7, 8-PeCDF concentration represented 22.7-35.6 % of total TEQ concentration.

  • PDF

Disposal of Polychlorinated Biphenyls(PCBs) by a Combined Chemical with Thermal Treatment (화학 및 열적 처리를 이용한 폴리염화바이페닐(PCB)의 제거)

  • Ryoo, Keon Sang
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.3
    • /
    • pp.286-293
    • /
    • 1999
  • A comnprehensive process which combines chemical with thermal treatment by controlled counterflow oxidation has been developed for disposal of PCBs in transformer oil. PCBs which not completely removed by chemical treatment, after being filtered with appropriate adsorbent during the oil circulations, was thermally treated. Destruction efficiencies of better than 99.99% was obtained, with no measurable formation of PCDDs (polychlorinated dibenzo-p-dioxins) or PCDFs (polychlorinated dibenzofurans). The combination also permits high recovery of oil and inorganic supports from scrap power transformers. The process is environmentally benign, easy to use and less capital intensive than other available technologies.

  • PDF

Source Estimation of Dioxin in Soil Using a Congener Pattern (이성체 정보를 이용한 토양 중 다이옥신 오염원 해석)

  • Kim, Jong-Guk;Kim, Kyoung-Soo;Kim, Jae-Sik;Shin, Sun-Kyoung;Chung, Young-Hee;Chung, Il-Rok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.316-322
    • /
    • 2005
  • In this study, the concentration of 17 dioxin congeners in the soil samples near a waste incinerator with respect to distance from incinerator and wind directions were investigated. The effect of PCB source was investigated using the cluster analysis method. The total concentration and I-TEQ concentration of dioxin ranged from 31.065 to 7,257.499 pg/g(dry weight) and from 0.099 to 35.191 pg I-TEQ/g(dry weight.), respectively. There was a weak correlation(not statistically significant) observed between soil concentration and wind direction, and the distance from the incinerator. The reason may be due to the presence of the local combustion sources other than the target incinerator. The fraction of PCDFs and PCDDs was also examined to study the effect of incinerator. The fraction of PCDFs was decreased with the distance from the incinerator. The influence of target incinerator was found within a 500-meter radius. The high concentration in the for site was due to small incinerators and the use of agricultural chemicals such as PCP. To investigate the relationship between soil near the incinerator and the sources, the cluster analysis was conducted using the congener pattern. As a result soil samples were divided into four groups and were qualitatively estimated the influence of sources such as incinerator and PCP by comparing the congener pattern of each roups. It was thought that a cluster analysis was a useful statistical method for the source estimation of dioxin.

A Temporal Trend of Dioxins Levels in Environmental Media

  • Park, Kyunghee;Daeil Kang;Junheon Youn;Lee, Choong;Sunghwan Jeon;Jingyun Na
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.148-148
    • /
    • 2003
  • This study is to investigate the environmental levels and trend of dioxins, which was the 3$\^$rd/ year of environmental monitoring research for endocrine disrupting chemicals since 1999. Total 282 samples were analyzed from 115 sites including 26 sites of airs, 43 sites of waters, 11 sites of sediments and 35 sites of soil, which were the same as those of investigated sites in 2000. Sampling period was from June 2001 to June 2002. Target chemicals were seventeen species of 2,3,7,8-chlorine-substituted PCDD and PCDF congeners and were analyzed by the standard methods, established by National Institute Environmental Research (NIER). The average concentration of dioxins in air decreased from 0.324 pg-TEQ/N㎥ in 2000 to 0.287 pg-TEQ/N㎥ in 2001, and those in water and soil were 0.073pg-TEQ/L and 1.703pg-TEQ/dry g, respectively, which was the less values detected in 2000. In sediment, however, the value was 0.086pg-TEQ/dry g, which was the increase from the value of the year 2000. The concentration range of dioxins in air for 26 sites in 17 regions detected were 0.013∼l.664pg-TEQ/N㎥, 4 sites from those were exceeded the Air Quality Standards of Dioxin in Japan (0.6 pg-TEQ/N㎥). The tolerable daily intake of dioxins was calculated at the highest level (1.664) in air, with referring the soil and food data from Japan, was calculated to be 2.85pg-TEQ/kg/day, which was below the level of 4 pg-TEQ/kg/day suggested in KFDA(Korea). While the average concentration of dioxins in 15 big cities was 0.190 pg-TEQ/N㎥, that in 8 medium/small cities constituting an industrial complex was 0.558 pg-TEQ/N㎥. In water, the concentration range detected were 0∼0.946pg-TEQ/L and the trend of the average concentrations shows an increase from those of 1999 but decreased from those of 2000, any sites however were not exceeded the Water Quality Standards of Dioxin in Japan (1 pg- TEQ/L). In soil. the detected range were 0∼43.333 pg-TEQ/dry g and the average concentration decreased, compared with the results of 2000. According to the monitoring results by land utilization, the detected range were 0∼43.333pg-TEQ/dry g in farmland, 0.017∼0.601 pg-TEQ/dry g in the industrial area, 0.005∼0.049pg-TEQ/dry g in the park and 0.008∼1.825 pg-TEQ/dry g in the rest. In sediment, the detected range increased from 0∼0.244 pg-TEQ/dry g to 0∼0.537 pg-TEQ/dry g, based on the results of 2000. For the proper control of dioxins, continuous monitoring needs to be performed and in addition, the dioxin inventory should be prepared for major sources through the dioxin emission survey. These results would provide sound and solid basis for proper decision making of dioxins management like establishment of environmental quality standards in Korea.

  • PDF