• Title/Summary/Keyword: PC5

Search Result 3,306, Processing Time 0.033 seconds

An Experimental Study on Thermal Damage under Tunnel Fire Scenario to Concrete PC Pannel Lining (터널 화재시나리오에 따른 콘크리트 PC패널라이닝의 열적손상에 관한 실험적 연구)

  • Kim, Heung-Youl;Park, Kyung-Hun;Kim, Hyung-Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.477-480
    • /
    • 2008
  • In tunnel, though the frequency of fire occurrence is relatively lower than other structures, the characteristics of sealed space tends to cause the temperature to rapidly rise to more than $1000^{\circ}C$ within 5 minutes after fire, which might eventually lead to a large fire that usually results in a loss of lives and the damage to the properties, not to mention a huge cost necessary for repair and maintenance after fire. Referring to foreign tunnel fire scenarios, it clarified the heat transfer characteristics of concrete PC panel lining depending on fire intensity (ISO, MHC, RWS), and to identify the range of thermal damage, the evaluation was carried out using ITA standard. As a result, 39mm under ISO fire condition, 50mm under MHC and 100mm under RWS were measured. And when it comes to spalling, 30mm was measured under RWS. When PC panel was designed to serve the support, a fire resistance to the minimum depth of 100mm of the concrete that might be damaged under the fire shall be maintained, and in case of a non-support structure, PC lining shall have at least 100mm thickness.

  • PDF

Trapping centers due to native defects in the $CdIn_2S_4$ films grown by hot wall epitaxy

  • Hong, Myung-Seuk;Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.167-168
    • /
    • 2007
  • $CdIn_2S_4$ (110) films were grown on semi-insulating GaAs (100) by a hot wall epitaxy method. Using photocurrent (PC) measurement, the PC spectra in the temperature range of 30 and 10 K appeared as three peaks in the short wavelength region. It was found that three peaks, A-, B-, and C-excitons, correspond to the intrinsic transition from the valence band states of ${\Gamma}_4(z),\;{\Gamma}_5(x),\;and\;{\Gamma}_5(y)$ to the exciton below the conduction band state of ${\Gamma}_1(s)$, respectively. The 0.122 eV crystal field splitting and the 0.017 eV spin orbit splitting were obtained. Thus, the temperature dependence of the optical band gap obtained from the PC measurement was well described by $E_g$(T)=2.7116eV - $(7.65{\times}10^{-4}\;eV/K)T^2$/(425+T). But, the behavior of the PC was different from that generally observed in other semiconductors. The PC intensities decreased with decreasing temperature. This phenomenon had ever been reported at a PC experiment on the bulk crystals grown by the Bridgman method. From the relation of log $J_{ph}$ vs 1/T, where $J_{ph}$ is the PC density, two dominant levels were observed, one at high temperatures and the other at low temperatures. Consequently, the trapping centers due to native defects in the $CdIn_2S_4$ film were suggested to be the causes of the decrease in the PC signal with decreasing temperature.

  • PDF

Effects of Chelidonine on L-DOPA-Induced Cytotoxicity in PC12 Cells (Chelidonine이 PC12 세포내의 L-DOPA-유도 세포독성에 미치는 영향)

  • Kim, Yu-Mi;Lee, Jae-Joon;Jin, Chun-Mei;Yang, Yoo-Jung;Kang, Min-Hee;Lee, Myung-Koo
    • Korean Journal of Pharmacognosy
    • /
    • v.34 no.3 s.134
    • /
    • pp.242-245
    • /
    • 2003
  • The effects of chelidonine, a benzophenanthridine isoquinoline alkaloid, on L-DOPA-induced cytotoxicity in PC12 cells were investigated. The treatment of PC12 cells with chelidonine $(1-4\;{\mu}M)$ decreased dopamine content in a dose-dependent manner (30.2% inhibition at $4\;{\mu}M)$. Chelidonine was not cytotoxic up to $4\;{\mu}M)$. However, chelidonine at concentrations higher than $5\;{\mu}M$ caused a cytotoxicity in PC12 cells. L-DOPA at concentrations higher than $50\;{\mu}M$ led to cell damage by oxidative stress in PC12 cells. Chelidonine at non-cytotoxic concentration ranges of $1-4{\mu}M$ aggravated L- DOPA $(20-50\;{\mu}M)$-induced cytotoxicity in PC12 cells. The L-DOPA-induced cytotocxicity was synergistically stimulated by chelidonine at concentrations grader than $5\;{\mu}M$. These data demonstrate that chelidonine exacerbates L-DOPA-induced cytotoxicity. Therefore, it is proposed that the long-term L-DOPA therapeutic patients with chelidonine may need to be checked for the adverse symptoms.

Development of Form to Improve the Productivity of PC Structure Connections -Focused on Apartment Buildings- (PC구조 접합부공사의 생산성 향상을 위한 거푸집 개발 -공동주택을 중심으로-)

  • Kim, Seon-Hyung;Lee, Won-Suk;Kim, Sun-Kuk;Lee, Dong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.11-20
    • /
    • 2010
  • With the amendment to the Building Act in November of 2005 that offered incentives in terms of floor area ratio and number of stories to apartment buildings adopting the Rahmen structure to facilitate remodeling, the construction industry is paying more attention to PC structures. As connections between PC columns and beams require complex design, it is very difficult to install and remove forms. Since forms made of plywood for such connections are fabricated and installed on site, a significant amount of labor is required, and constructability is low. Furthermore, after concrete casting, the forms are removed in a state in which they cannot be recycled, which leads to a significant amount of construction waste. For this reason, a solution to address such issues needs to be studied. However, many researchers have focused only on the structural performance of PC structures in Korea and elsewhere, ignoring the need for research on the forms used in building PC structure connections. Therefore, this research aims to develop a form that can improve the productivity of PC structure connection construction, and compare it with conventional forms to highlight its contribution to gains in productivity and economic viability.

Secondhand Smoke Exposure in Commercial Personal Computer Rooms (PC 방 금연구역의 간접흡연 노출)

  • Sohn, Hong-Ji;Oh, Ae-Ri;Kim, Ok-Gum;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.288-293
    • /
    • 2010
  • In this study, exposure to secondhand smoke (SHS) was evaluated in commercial personal computer (PC) rooms with different separation types of non-smoking areas. The particulate matter less than 2.5 ${\mu}m$ ($PM_{2.5}$) level was simultaneously measured by aerosol spectrometers in the non-smoking and smoking areas of these commercial PC rooms. Average $PM_{2.5}$ concentrations in non-smoking and smoking areas were $75\;{\mu}g/m^3$ and $136\;{\mu}g/m^3$, respectively. Although the $PM_{2.5}$ concentrations in non-smoking areas were significantly less than those in smoking areas (p<0.01), the levels still exceeded the US National Ambient Air Quality Standard of $35\;{\mu}g/m^3$. Average $PM_{2.5}$ concentrations in non-smoking areas were not significantly different with regard to area separation type, with $73\;{\mu}g/m^3$ in the no-wall type, $83\;{\mu}g/m^3$ in the wall-type, and $39\;{\mu}g/m^3$ in the separated-floor-type areas (p>0.1). Separation of the non-smoking area thus did not eliminate SHS exposure in commercial PC rooms, regardless of the type of area separation. This study demonstrates that simple separation of non-smoking areas in commercial PC rooms does not protect users from SHS.

A Study on the Influence of Franchise PC Game Rooms Store Attributes on Store Selection Behavior (프랜차이즈 피씨방 점포선택속성이 점포선택행동에 미치는 영향)

  • Seong, Baiksoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.3
    • /
    • pp.231-240
    • /
    • 2015
  • This study empirically analyzed the relationship between the franchise pc game rooms selection behavior and revisit, recommendations. Select Properties from the franchise pc game rooms store is ease of access, computer specifications, pleasant environment, brand power and pricing strategy. Korean franchise industry is in spite of the short history of just over 30 years growing very fast. Especially pc game rooms store is 14,782 in 2012 years, pc game rooms store is operated by franchise form 10.6%, 87.9% operated by private, co-operation was confirmed at 1.5%. Conclusions are as follows. First, factors that significantly affect the degree of revisit has been identified as computer specifications, pleasant environment, brand power. Second, the recommendation is an important factor of the computer specifications, brand power, pricing strategy. Finally, franchise pc game rooms successful strategy has excellent computer's specifications, it needs a promotion strategy to attract pc game tournaments to be notified of brand power. We can also see that running is an important factor in a pleasant environment and a flexible pricing strategy.

Verification of the Use of Architectural PC for Improving the productivity in an Apartment Housing Project (공동주택 공사에서의 건축 외관용 PC 활용에 따른 생산성 향상 분석)

  • Lee, Hyun-Seok;Lee, Sang-Hyo;An, Byung-Ju;Lee, Yoon-Sun;Kim, Jae-Jun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.670-673
    • /
    • 2007
  • In Korea, it has recently occurred that problems of productivity and construction duration in the construction industry. If five days per week system come into effect, they'll become more urgent. The productivity of construction industry and competitive construction duration in Korea are too low. If post sale system becomes effective, construction companies will strive to improve productivity. Therefore, the objective of this study is to draw up Architectural PC as the alternative for productivity improving and analyze possibility of productivity improving by comparing with established method of construction.

  • PDF

In situ Structural Investigation of Iron Phthalocyanine Monolayer Adsorbed on Electrode Surface by X-ray Absorption Fine Structure

  • Kim, Seong Hyeon;Toshiaki Ohta;Gang, Gwang Hun
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.6
    • /
    • pp.588-594
    • /
    • 2000
  • Structural changes of an iron phthalocyanine (FePC) monolayer induced by adsorption and externally applied potential on high area carbon surface have been investigated in situ by iron K-edge X-ray absorption fine structure (XAFS) in 0.5 M $H_2S0_4.$ Fine structures shown in the X-ray absorption near edge structure (XANES) for microcrystalline FePC decreased upon adsorption and further diminished under electrochemical conditions. Fe(II)PC(-2) showed a 1s ${\rightarrow}$ 4p transition as poorly resolved shoulder to the main absorption edge rather than a distinct peak and a weak 1s ${\rightarrow}$ 3d transition. The absorption edge position measured at half maximum was shifted from 7121.8 eV for Fe(lI)PC(-2) to 7124.8 eV for $[Fe(III)PC(-2)]^+$ as well as the 1s ${\rightarrow}$ 3d pre-edge peak being slightly enhanced. However, essentially no absorption edge shift was observed by the 1-electron reduction of Fe(Il)PC(-2), indicating that the species formed is $[Fe(II)PC(-3)]^-$. Structural parameters were obtained by analyzing extended X-ray absorption fine structure (EXAFS) oscillations with theoretical phases and amplitudes calculated from FEFF 6.01 using multiple-scattering theory. When applied to the powder FePC, the average iron-to-phthalocyanine nitrogen distance, d(Fe-$N_p$) and the coordination number were found to be 1.933 $\AA$ and 3.2, respectively, and these values are the same, within experimental error, as those reported ( $1.927\AA$ and 4). Virtually no structural changes were found upon adsorption except for the increased Debye-Wailer factor of $0.005\AA^2$ from $0.003\AA^2.$ Oxidation of Fe(II)PC(-2) to $[Fe(III)PC(-2)]^+$ yielded an increased d(Fe-Np) (1 $.98\AA)$ and Debye-Wailer factor $(0.005\AA^2).$ The formation of $[Fe(II)PC(-3)]^-$, however, produced a shorter d(Fe-$N_p$) of $1.91\AA$ the same as that of crystalline FePC within experimental error, and about the same DebyeWaller $factor(0.006\AA^2)$.