• Title/Summary/Keyword: PBU

Search Result 34, Processing Time 0.03 seconds

Seamless handover protocol to reduce handover latency (핸드오버 지연 시간을 줄일 수 있는 심리스 핸드오버 프로토콜 제안 및 성능 분석)

  • Jang, Jong-Min;Lee, Yu-Tae;Lee, Soong-Hee;Kim, Dong-Il;Choi, Sam-Gil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.2
    • /
    • pp.277-284
    • /
    • 2009
  • With significant development in wireless communication technologies, the needs to handover from one network to another have grown dramatically. Recently IETF developed MIPv6 and FMIPv6 which are used to handover between different access networks. These handover mechanisms have some known weaknesses. MIPv6 can not serve time-critical application because it causes long handover latency and packet loss. By these reasons, MIPv6 does not guarantee session continuity. FMIPv6 uses handover preparation phase to reduce DAD latency. However FMIPv66 still suffers from long handover latency, because it must perform binding update at the end of handover procedure. In this paper we propose new handover mechanism FMIPv6-PBU which eliminates binding update latency. The proposed mechanism has compatability with lagacy FMIPv6. In this paper propose FMIPv6-PBU handover procedure and explain its procedures and evaluate it with MIPv6 and FMIPv6.

Effects of Straight Leg Lifts and Double Leg Lowering Exercise on Abdominal Muscle Activity, Back Pain, and Flexibility in Patients with Chronic Low Back Pain in their 50s (50대 만성허리통증 환자들을 대상으로 다리들기와 다리내리기 운동이 배 근육의 활성도, 허리통증, 그리고 유연성에 미치는 영향)

  • Bae, Wonsik;Lee, Keoncheol;Park, Hankyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.61-69
    • /
    • 2019
  • Purpose : The purpose of this study was to investigate the effects of Straight leg lifts (SLL) and double leg lowering (DLL) exercise on abdominal muscle activity, visual analog scale (VAS), and flexibility in patients with chronic low back pain (LBP). Methods : A total of 30 LBP patients were divided into two groups: those with SLL exercise group 15 (male=8, female=7) and those with DLL exercise group 15 (male=7, female=8). Before the intervention, the abdominal muscle activity, VAS, and flexibility were measured. After 4 weeks of intervention, the above variables were measured in the same way. The SLL exercise bends the leg $45^{\circ}$ in the supine position, and the DLL exercise was performed as opposed to SLL. At this time, the pressure biofeedback unit (PBU) was placed behind the lumbar to reduce the instability of the pelvis and muscles. The subjects were instructed to use the PBU to maintain the target pressure determined (40 mmHg) during the exercise. Results : The external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) were significantly different in the SLL and DLL group, and EO, IO, and TrA activity improved more significantly increased in the DLL than SLL group (p<.05). The results on the VAS and flexibility were significantly different both group (p<.05). However, there was no significant difference between the groups (p>.05). Conclusion : SLL and DLL exercises in patients with LBP were able to confirm the increased activity of the abdominal muscles, decreased pain, and increased flexibility of the waist. In addition, DLL exercise is more effective in patients with LBP in terms of muscle activity.

Concurrent Validity and Test-retest Reliability of the Core Stability Test Using Ultrasound Imaging and Electromyography Measurements

  • Yoo, Seungju;Lee, Nam-Gi;Park, Chanhee;You, Joshua (Sung) Hyun
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.186-193
    • /
    • 2021
  • Background: While the formal test has been used to provide a quantitative measurement of core stability, studies have reported inconsistent results regarding its test-retest and intraobserver reliabilities. Furthermore, the validity of the formal test has never been established. Objects: This study aimed to establish the concurrent validity and test-retest reliability of the formal test. Methods: Twenty-two young adults with and without core instability (23.1 ± 2.0 years) were recruited. Concurrent validity was determined by comparing the muscle thickness changes of the external oblique, internal oblique, and transverse abdominal muscle to changes in core stability pressure during the formal test using ultrasound (US) imaging and pressure biofeedback, respectively. For the test-retest reliability, muscle thickness and pressure changes were repeatedly measured approximately 24 hours apart. Electromyography (EMG) was used to monitor trunk muscle activity during the formal test. Results: The Pearson's correlation analysis showed an excellent correlation between transverse abdominal thickness and pressure biofeedback unit (PBU) pressure as well as internal oblique thickness and PBU pressure, ranging from r = 0.856-0.980, p < 0.05. The test-retest reliability was good, intraclass correlation coefficient (ICC1,2) = 0.876 for the core stability pressure measure and ICC1,2 = 0.939 to 0.989 for the abdominal muscle thickness measure. Conclusion: Our results provide clinical evidence that the formal test is valid and reliable, when concurrently incorporated into EMG and US measurements.

Effect of universal adhesive pretreatments on the bond strength durability of conventional and adhesive resin cements to zirconia ceramic

  • Tae-Yub Kwon;Seung-Hee Han;Du-Hyeong Lee;Jin-Woo Park;Young Kyung Kim
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.105-114
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the effect of pretreatment of three different universal adhesives (Single Bond Universal [SBU], All-Bond Universal [ABU], and Prime&Bond universal [PBU]) on the bonding durability of an adhesive (Panavia F 2.0, PF) and a conventional (Duo-Link, DL) resin cements to air-abraded zirconia. MATERIALS AND METHODS. Rectangular-shaped zirconia specimens were prepared. The chemical composition and surface energy parameters of the materials were studied by Fourier transform infrared spectroscopy and contact angle measurement, respectively. To evaluate resin bonding to the zirconia, all the bonding specimens were immersed in water for 24 h and the specimens to be aged were additionally thermocycled 10000 times before the shear bond strength (SBS) test. RESULTS. The materials showed different surface energy parameters, including the degree of hydrophilicity/hydrophobicity. While the DL/CON (no pretreatment) showed the lowest SBS and a significant decrease in the value after thermocycling (P < .001), the PF/CON obtained a higher SBS value than the DL/CON (P < .001) and no decrease even after thermocycling (P = .839). When the universal adhesives were used with DL, their SBS values were higher than the CON (P < .05), but the trend was adhesive-specific. In conjunction with PF, the PF/SBU produced the highest SBS followed by the PF/ABU (P = .002), showing no significant decrease after thermocycling (P > .05). The initial SBS of the PF/PBU was similar to the PF/CON (P = .999), but the value decreased after thermocycling (P < .001). CONCLUSION. The universal adhesive pretreatment did not necessarily show a synergistic effect on the bonding performance of an adhesive resin cement, whereas the pretreatment was beneficial to bond strength and durability of a conventional resin cement.

Effect of Abdominal Draw In Maneuver in Sitting Position (앉은자세에서 실시하는 복부드로우인기법의 효과)

  • Kim, Seon-Chil;Kim, Shin-Gyun;Kim, Chang-sook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.207-214
    • /
    • 2017
  • The problem of trunk stability is a major factor in back pain.. Abdominal draw in maneuver(ADIM), One of the trunk stabilization exercises to relieve lumbar instability, is a method of inducing selective contraction of the transverse abdominis associated with anticipatory posture control among the abdominal stabilization muscles. ADIM is usually performed with a visual feedback by applying a pressure biofeedback unit(PBU) under the lumbar at the supine position, which is not functional compared to the sitting position. This study was conducted to investigate the effect of ADIM applied in supine and sitting position on 31 healthy men and women. In each posture, muscle activity was measured by rectal abdominis (RA), external oblique (EO), transverse abdominis (TrA)/internal obilique (IO) and erector spinae (ES) using wireless EMG. In the result, there was no significant difference between RA and EO between the two postures and there was a significant difference between TrA / IO and ES. In both postures, the activity of TrA/IO was higher than that of RA, and the effect of ADIM was shown to be the same, whereas TrA/IO and ES showed higher activity in sitting position. This means that the activity of the muscles involved in the postural stability and lumbar stability is increased further in the sitting position. Therefore, ADIM in sitting, which can be applied more easily in daily life, is useful for improving lumbar stability.

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

Evaluation of the usefulness of Images according to Reconstruction Techniques in Pediatric Chest CT (소아 흉부 CT 검사에서 재구성 기법에 따른 영상의 유용성 평가)

  • Gu Kim;Jong Hyeok Kwak;Seung-Jae Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.285-295
    • /
    • 2023
  • With the development of technology, efforts to reduce the exposure dose received by patients in CT scans are continuing with the development of new reconstruction techniques. Recently, deep learning reconstruction techniques have been developed to overcome the limitations of repetitive reconstruction techniques. This study aims to evaluate the usefulness of images according to reconstruction techniques in pediatric chest CT images. Patient study conducted a study on 85 pediatric patients who underwent chest CT scan at P-Hospital in Gyeongsangnam-do from January 1, 2021 to December 31, 2022. The phantom used in the Phantom Study is the Pediatrics Whole Body Phantom PBU-70. After the test, the images were reconstructed with FBP, ASIR-V (50%) and DLIR (TF-Medium, High), and the images were evaluated by obtaining SNR and CNR values by setting ROI of the same size. As a result, TF-H of deep learning reconstruction techniques had the lowest noise value compared to ASIR-V (50%) and TF-M in all experiments, and SNR and CNR had the highest values. In pediatric chest CT scans, TF images with deep learning reconstruction techniques were less noisy than ASiR-V images with adaptive statistical iterative reconstruction techniques, CNR and SNR were higher, and the quality of images was improved compared to conventional reconstruction techniques.

A Mechanism for Supporting 6LoWPAN Node Mobility based on Proxy Mobile IPv6 (Proxy Mobile IPv6 기반 6LoWPAN 노드의 이동성 지원 기법)

  • Kim, Jin-Ho;Lee, Hye-Chan;Hong, Choong-Seon
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06d
    • /
    • pp.470-475
    • /
    • 2008
  • 6LoWPAN 센서 노드의 이동성을 지원하기 위해 기존의 Mobile IPv6 (MIPv6)와 같은 프로토콜을 활용하는 것은 저전력에 제한적 사양의 하드웨어로 구성된 6LoWPAN 센서 노드에서 구동되는 것이 현실적으로 불가능하다. 따라서 Mobile Access Gateway (MAG)가 6LoWPAN 센서 노드의 이동시 발생하는 바인딩 시그널링을 대신 처리해주는 Proxy Mobile IPv6 (PMIPv6) 프로토콜을 6LoWPAN에 적용하면 효율적으로 이동성을 지원할 수 있다. 하지만 Proxy Mobile IPv6는 6LoWPAN 이동 센서 노드와 1홉으로 연결되는 경우에 6LoWPAN 이동 센서 노드의 이동을 인지하고 Proxy Binding Update(PBU)를 하게 되지만, 6LoWPAN 센서 네트워크와 같이 멀티 홉으로 구성되는 네트워크에는 Proxy Mobile IPv6를 바로 적용할 수 없다. 따라서 본 논문에서는 기존의 1홉 단위로 연결된 6LoWPAN 이동 센서 노드의 이동성을 지원하는 Proxy Mobile IPv6 프로토콜을 멀티를 환경의 6LoWPAN 센서 네트워크에 적용하기 위한 방법을 제안한다.

  • PDF

LC-GM2: Low-Cost Global Mobility Management Scheme in Proxy Mobile IPv6 Networks (프록시 모바일 IPv6 네트워크에서 저비용의 글로벌 이동성관리 기법)

  • Kim, Jongyoun;Park, Jongsun;Jeong, Jongpil
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.193-204
    • /
    • 2012
  • This paper specifies a low-cost global mobility management architecture and protocol procedure called LC-$GM^2$, which is based on Proxy Mobile IPv6. In LC-$GM^2$, mobility management is performed by the network entity. The benefit is the elimination of the wireless link data delivery tunnel overhead between a mobile node and the access router. To compare with the well-known Hierarchical Mobile IPv6 mobility management protocol and GPMIP, the location update, packet delivery, and total cost functions generated by a mobile node during its average domain residence time are formulated for each protocol based on Fluid-flow mobility model. Then, the impacts of various system parameters on the cost functions are analyzed. The analytical results indicate that the proposed global mobility management protocol can guarantee lower total costs.

Immediate Effects of Roller Massage for Posterior Neck Muscles on the Muscle Strength and Range of Motion for Cranio-Cervical Flexion in Subjects With Forward Head Posture

  • Kang, Seung-tak;Jung, Jang-hun;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.28 no.2
    • /
    • pp.138-145
    • /
    • 2021
  • Background: Forward head posture (FHP) causes various posture imbalances associated with the head and neck. Myofascial release is an effective treatment method used for relaxing muscles and reducing muscle hyperactivity, but no studies have been conducted on suboccipital and neck muscles related to FHP. Objects: The purpose of this study was to investigate the immediate effect of roller massages on the cranio-cervical flexion (CCF) range of motion (ROM) and CCF strength applied to suboccipital and neck muscles in subject with forward head posture. Methods: Twenty-four FHP subjects (male: 13, female: 11) were recruited for this study. All subjects were recruited with a craniovertebral angle (CVA) of 53 degrees or less and a head tilt angle (HTA) of 20.66 degrees or higher. CCF strength was measured using Pressure biofeedback unit (PBU) in the supine posture and CCF ROM was measured using smartphone-based inclinometer. Roller massage (RM) was applied to suboccipital and neck muscles for 2 minutes and CCF ROM and strength were remeasured. Results: These results of this study showed that CCF ROM was a significant difference in CCF ROM before and after RM (p < 0.05). CCF strength also showed a significant difference before and after RM (p < 0.05). Conclusion: RM method might be recommended to increase the immediate ROM and strength of CCF in subjects with forward head posture.