• Title/Summary/Keyword: PACS 보안평가

Search Result 4, Processing Time 0.02 seconds

Research on a Valuation Standard and the Actual Condition About Security Management in PACS (PACS에서 보안관리 평가기준 연구와 실태조사)

  • Jeong, Jae-Ho;Dong, Kyung-Rae;Kweon, Dae-Cheol;Son, Gi-Gyeong;Kim, Hyun-Soo;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.347-353
    • /
    • 2008
  • This study is to prepare an evaluation standard about personal information protection and security management of a medical institution and to build up a grade standard of evaluation in PACS environment. We built up evaluation index based on 10 detailed items in four big categories (political security, technical security, data management security and physical security) by referring to ISO17799 (BS 7799), HIPPA (Health Insurance and Portability and Accountability Act of 1996) and domestic medical law. We have investigated at the thirty places where medical facility with the extracted security criteria and security evaluation index. Average score of physical security list, one of the big categories, was 18.5/20 (93%) at all medical institutions. Political security score was 18.5/30 (62%), data management security score was 12/20 (60%) and technical security score was 17.5/30 (58%). Therefore, security evaluation score was average 67 in 30 general hospitals, which was 4th level. The results showed that it is necessary to establish evaluation and management standard about personal information protection and security consciousness which are weak in PACS environment.

  • PDF

Design and Performance Evaluation of the Secure Transmission Module for Three-dimensional Medical Image System based on Web PACS (3차원 의료영상시스템을 위한 웹 PACS 기반 보안전송모듈의 설계 및 성능평가)

  • Kim, Jungchae;Yoo, Sun Kook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.179-186
    • /
    • 2013
  • PACS is a medical system for digital medical images, and PACS expand to web-based service using public network, DICOM files should be protected from the man-in-the-middle attack because they have personal medical record. To solve the problem, we designed flexible secure transmission system using IPSec and adopted to a web-based three-dimensional medical image system. And next, we performed the performance evaluation changing integrity and encryption algorithm using DICOM volume dataset. At that time, combinations of the algorithm was 'DES-MD5', 'DES-SHA1', '3DES-MD5', and '3DES-SHA1, and the experiment was performed on our test-bed. In experimental result, the overall performance was affected by encryption algorithms than integrity algorithms, DES was approximately 50% of throughput degradation and 3DES was about to 65% of throughput degradation. Also when DICOM volume dataset was transmitted using secure transmission system, the network performance degradation had shown because of increased packet overhead. As a result, server and network performance degradation occurs for secure transmission system by ensuring the secure exchange of messages. Thus, if the secure transmission system adopted to the medical images that should be protected, it could solve server performance gradation and compose secure web PACS.

Using CR System at the Department of Radiation Oncology PACS Evaluation (방사선 종양학과에서 CR System을 이용한 PACS 유용성 평가)

  • Hong, Seung-Il;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.143-149
    • /
    • 2012
  • Today each hospital is trend that change rapidly by up to date, digitization and introducing newest medical treatment equipment. So, we introduce new CR system and supplement film system's shortcoming and PACS, EMR, RTP system's network that is using in hospital harmoniously and accomplish quality improvement of medical treatment and service elevation about business efficiency enlargement and patient Accordingly, we wish to introduce our case that integrate reflex that happen with radiation oncology here upon to PACS using CR system and estimate the availability. We measured that is Gantry, Collimator Star Shot, Light vs. Radiation, HDR QA(Dwell position accuracy) with Medical LINAC(MEVATRON-MX) Then, PACS was implemented on the digital images on the monitor that can be confirmed through the QA. Also, for cooperation with OCS system that is using from present source and impose code that need in treatment in each treatment, did so that Order that connect to network, input to CR may appear, did so that can solve support data mistake (active Pinacle's case supports DICOM3 file from present source but PACS does not support DICOM3 files.) of Pinacle and PACS that is Planning System and look at Planning premier in PACS. All image and data constructed integration to PACS as can refer and conduct premier in Hospital anywhere using CR system. Use Dosimetry IP in Filmless environment and QA's trial such as Light/Radition field size correspondence, gantry rotation axis' accuracy, collimator rotation axis' accuracy, brachy therapy's Dwell position check is available. Business efficiency by decrease and so on of unnecessary human strength consumption was augmented accordingly with session shortening as that integrate premier that is neted with radiation oncology using CR system to PACS. and for the future patient information security is essential.

A Study of Establishment of Softwaresystem Configuration for Improving Health Information Sharing (의료정보 공유기능 향상을 위한 소프트웨어시스템 기반구성 방법에 관한 연구)

  • Han, Soon-Hwa;Ju, Se-Jin
    • Journal of Digital Contents Society
    • /
    • v.15 no.1
    • /
    • pp.11-18
    • /
    • 2014
  • The strength of our country is based on high-speed networks to build a nationwide health information network to improve the quality of health care is needed. However, nature of the medical services in the hospital medical record form, so that all departments characterize each medical department, a common format that can be used for all disease is a very difficult challenge. This study is one of the ways to improve this priority issue on health information sharing medical information system(PACS/HIS) information linkage between the problem of information, compatibility and security issues derived. The problem is derived from the requirements of theorem 3 to 6 items. This is effective in order to improve sharing of medical information for the purpose of designing the software system. Sharing of medical information software system design are derived from stakeholders, requirements analysis, architecture design, software framework, configuration, architecture evaluation process. This study is based on the medical information standardization environmental diagnosis of a medical information system design. Software design philosophy is based on a new framework for deriving the function and mechanism made up.