• Title/Summary/Keyword: P2P 제어

Search Result 974, Processing Time 0.033 seconds

The Effect of Recombinant Human Epidermal Growth Factor on Cisplatin and Radiotherapy Induced Oral Mucositis in Mice (마우스에서 Cisplatin과 방사선조사로 유발된 구내염에 대한 재조합 표피성장인자의 효과)

  • Na, Jae-Boem;Kim, Hye-Jung;Chai, Gyu-Young;Lee, Sang-Wook;Lee, Kang-Kyoo;Chang, Ki-Churl;Choi, Byung-Ock;Jang, Hong-Seok;Jeong, Bea-Keon;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.242-248
    • /
    • 2007
  • Purpose: To study the effect of recombinant human epidermal growth factor (rhEGF) on oral mucositis induced by cisplatin and radiotherapy in a mouse model. Materials and Methods: Twenty-four ICR mice were divided into three groups-the normal control group, the no rhEGF group (treatment with cisplatin and radiation) and the rhEGF group (treatment with cisplatin, radiation and rhEGF). A model of mucositis induced by cisplatin and radiotherapy was established by injecting mice with cisplatin (10 mg/kg) on day 1 and with radiation exposure (5 Gy/day) to the head and neck on days $1{\sim}5$. rhEGF was administered subcutaneously on days -1 to 0 (1 mg/kg/day) and on days 3 to 5 (1 mg/kg/day). Evaluation included body weight, oral intake, and histology. Results: For the comparison of the change of body weight between the rhEGF group and the no rhEGF group, a statistically significant difference was observed in the rhEGF group for the 5 days after day 3 of. the experiment. The rhEGF group and no rhEGF group had reduced food intake until day 5 of the experiment, and then the mice demonstrated increased food intake after day 13 of the of experiment. When the histological examination was conducted on day 7 after treatment with cisplatin and radiation, the rhEGF group showed a focal cellular reaction in the epidermal layer of the mucosa, while the no rhEGF group did not show inflammation of the oral mucosa. Conclusion: These findings suggest that rhEGF has a potential to reduce the oral mucositis burden in mice after treatment with cisplatin and radiation. The optimal dose, number and timing of the administration of rhEGF require further investigation.

A Study on Nutritive Values and Salt Contents of Commercially Prepared Take-Out Boxed-Lunch In Korea (한국형 시판 도시락의 영양가 및 식염함량)

  • Kim, Bok-Hee;Lee, Eun-Wha;Kim, Won-Kyung;Lee, Yoon-Na;Kwak, Chung-Shil;Mo, Sumi
    • Journal of Nutrition and Health
    • /
    • v.24 no.3
    • /
    • pp.230-242
    • /
    • 1991
  • This research was conducted on the 10 take-out boxed-lunches commercially prepared in the department stores. chain stores. and the public railroad trains in Korea. Sampling was conducted from February 1990 to March 1990. Nutritive values and sodium contents of the 10 boxed-lunch samples are summarized as follows : 1) The average weight(percentage) of the cooked rice and the side dishes were 304.6g(49.4) and 312.4(506%), respectively. The weight of these samples were significantly heavier than that of Japanese style boxed-lunches. 2) The average number of the side dishes was 12. The average numbers of food items classified by the five food groups were 6.1 in protein food group, 0.3 in calcium food group. 6.0 in vitamin and mineral food group. 1.5 in carbohydrate food group, and 1.5 in oil and fat food group. 3) They contained on the average 840.7kcal of energy, 38.9g of protein, 22.7g of fat, 120.4g of carbohydrate. 300.8mg of calcium. 410.8mg of phosphours, 6.61 mg of iron. 219.8 R.E. of vitamin A, 0.46mg of thiamin, 0.67mg of riboflavin, 10.5mg of niacin, 27.5mg of ascorbic acid. Thus. except vitamin t the content of all the nutrients were higher than the value of 1/3 of the RDA for adults. 4) The high priced group(group 2) had more protein, calcuim. iron and niacin contents than the cheaper group(group 1). Probably, it's because the group 2 had more animal foods than the group 1. 5) The average energy content per unit price(100 won) was 37.3kcal and the average protein content per unit price(100 won) was 1.64g. Korena style boxed-lunches had higher energy and protein contents per unit price than Japanese style, and the group 1 higher than the group 2. 6) The average energy Proportions of Protein, carbohydrate. and fat were 18.3%, 57.4%, and 24.3%, respectively. These proportions are good enough. 7) Frequency of cooking methods for the side dishes were found in the decreasing order : pan-frying, frying, braising, seasoning, kimchi, grilling, pickling, stir-frying, steaming and fermenting. Generally simple cooking methods were used, thus the menus were lack or varieties. 8) Frequency of colors for the side dishes were found in the decreasing order : red, brown. yellow, green, black, white. Too much red pepper was used. 9) The average capacity of the containers for the staples and the side dishes were 468.1ml and 590.6ml, respectively. And the containers could not keep the food items well seperated. 10) The average contensts of sodium and salt were 2.287mg and 5.76g, in the range of 1, 398mg to 3, 489mg and 3.53g to 8.80g, respectively. These are much higher values than the recommended amount of salt.

  • PDF

Comparison of the Mechanical Properties between Bulk-fill and Conventional Composites (Bulk-fill 복합레진과 전통적 복합레진의 물성비교)

  • Noh, Taehwan;Song, Eunju;Park, Soyoung;Pyo, Aeri;Kwon, Yonghoon;Kim, Jiyeon;Kim, Shin;Jeong, Taesung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.365-373
    • /
    • 2016
  • Composites are the most useful restorative material. However, composites have some disadvantages such as polymerization shrinkage, long working time, and susceptibility to water and contamination, which are stood out more especially when treating children. To solve these problems, bulk-fill composites have been developed. The aim of this study is to compare mechanical properties of bulk-fill and conventional composites. Bulk-fill composites (SureFil SDR flow (SDR), Tetric N-Ceram bulk fill (TBF)) and conventional composites (Filtek Z-350 (Z-350), Unifil Flow (UF), Unifil Loflo Plus (UL)) were used. The Vickers hardness tester was used to measure the microhardness of materials, and Fourier transform infrared spectroscopy was used to measure the degree of conversion. Polymerization shrinkage was measured by using a linometer. Flexural and compressive properties were measured by using the universal testing machine. Data were statistically analyzed by ANOVA and Scheffe's post hoc test. The level of significance was set to p < 0.05. Most conventional composites showed higher microhardness than bulk-fill composites. However, bulk-fill composites showed a higher top/bottom microhardness ratio than conventional composites. Bulk-fill composites showed a higher top/bottom degree of conversion ratio than conventional composites. The polymerization shrinkage was highest in UL and lowest in Z-350. The polymerization shrinkage of flowable composites was higher than that of non flowable composites. The compressive properties were highest in Z-350 and lowest in SDR and UL. In terms of flexural properties, Z-350 was the highest. However, none of the bulk-fill composites exhibited mechanical properties as good as those of conventional composites. Nonetheless, the ratio of microhardness and degree of conversion, which are important properties of bulk filling, were higher in bulk-fill composites. Therefore, the bulk-fill composites might be considered suitable restorative materials in pediatric dentistry.

Monitoring Bacillus cereus and Aerobic Bacteria in Raw Infant Formula and Microbial Quality Control during Manufacturing (영.유아용 식품원료의 Bacillus cereus와 일반세균 모니터링 및 제조공정 중 미생물 품질제어)

  • Jung, Woo-Young;Eom, Joon-Ho;Kim, Byeong-Jo;Ju, In-Sun;Kim, Chang-Soo;Kim, Mi-Ra;Byun, Jung-A;Park, You-Gyoung;Son, Sang-Hyuck;Lee, Eun-Mi;Jung, Rae-Seok;Na, Mi-Ae;Yuk, Dong-Yeon;Gang, Ji-Yeon;Heo, Ok-Sun;Yoon, Min-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.494-501
    • /
    • 2010
  • The purpose of this study was to examine the presence of Bacillus cereus, aerobic bacteria and coliforms in the raw material of infant formulas and investigate the manufacturing process in terms of microbial safety. Among ten kinds of raw infant formula material samples (n=20), Bacillus cereus appeared in two (n=4). Aerobic bacteria were not detected in raw infant formula material or maximum 4.15 log CFU/g. Eleven species of aerobic bacteria were isolated and 76% of them were Sphingomonas paucimobilis, Pseudomonas fluorescens, Rhizobium radiobactor, or Stenotrophomonas maltophilia. A Pearson's correlation analysis revealed that the most influential factors for detecting Bacillus cereus were aerobic bacteria and coliforms. In other words, when the measured values of aerobic bacteria and coliforms were higher, the possibility that Bacillus cereus would appear increased. In a regression model to predict Bacillus cereus, the rate of appearance was correlated with aerobic bacteria and coliforms, and its contribution rate for effectiveness was 86%. Improving microbial quality control by pasteurization, spray dry, popping and extrusion resulted in a decrease in the numbers of Bacillus cereus, aerobic bacteria and coliforms in the raw materials. The results suggest that a hazard analysis and critical control point system might be effective for reducing microbiological contamination.