• 제목/요약/키워드: P.S.N curve

검색결과 190건 처리시간 0.028초

Finite Element Analysis and Development of Interim Consolidated 5-N Curve for Fatigue Design of Welded Structure (용접구조물의 피로설계를 위한 유한요소 해석 및 통합 피로선도 초안 개발)

  • Kim, Jong-Sung;Jin, Tae-Eun;Hong, Jeong-Kyun;P. Dong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제27권5호
    • /
    • pp.724-733
    • /
    • 2003
  • Fatigue design rules for welds in the ASME Boiler and Pressure Vessels Code are based on the use of Fatigue Strength Reduction Factors(FSRF) against a code specified fatigue design curve generated from smooth base metal specimens without the presence of welds. Similarly, stress intensification factors that are used in the ASME B3l.1 Piping Code are based on component S-N curves with a reference fatigue strength based on straight pipe girth welds. But the determination of either the FSRF or stress intensification factor requires extensive fatigue testing to take into account the stress concentration effects associated with various types of component geometry, weld configuration and loading conditions. As the fatigue behavior of welded joints is being better understood, it has been generally accepted that the difference in fatigue lives from one type of weld to another is dominated by the difference in stress concentration. However, general finite element procedures are currently not available for effective determination of such stress concentration effects. In this paper, a mesh-insensitive structural stress method is used to re-evaluate the S-N test data, and then more effective method is proposed for pressure vessel and piping fatigue design.

Pleural Carcinoembryonic Antigen and Maximum Standardized Uptake Value as Predictive Indicators of Visceral Pleural Invasion in Clinical T1N0M0 Lung Adenocarcinoma

  • Hye Rim Na;Seok Whan Moon;Kyung Soo Kim;Mi Hyoung Moon;Kwanyong Hyun;Seung Keun Yoon
    • Journal of Chest Surgery
    • /
    • 제57권1호
    • /
    • pp.44-52
    • /
    • 2024
  • Background: Visceral pleural invasion (VPI) is a poor prognostic factor that contributes to the upstaging of early lung cancers. However, the preoperative assessment of VPI presents challenges. This study was conducted to examine intraoperative pleural carcinoembryonic antigen (pCEA) level and maximum standardized uptake value (SUVmax) as predictive markers of VPI in patients with clinical T1N0M0 lung adenocarcinoma. Methods: A retrospective review was conducted of the medical records of 613 patients who underwent intraoperative pCEA sampling and lung resection for non-small cell lung cancer. Of these, 390 individuals with clinical stage I adenocarcinoma and tumors ≤30 mm were included. Based on computed tomography findings, these patients were divided into pleural contact (n=186) and non-pleural contact (n=204) groups. A receiver operating characteristic (ROC) curve was constructed to analyze the association between pCEA and SUVmax in relation to VPI. Additionally, logistic regression analysis was performed to evaluate risk factors for VPI in each group. Results: ROC curve analysis revealed that pCEA level greater than 2.565 ng/mL (area under the curve [AUC]=0.751) and SUVmax above 4.25 (AUC=0.801) were highly predictive of VPI in patients exhibiting pleural contact. Based on multivariable analysis, pCEA (odds ratio [OR], 3.00; 95% confidence interval [CI], 1.14-7.87; p=0.026) and SUVmax (OR, 5.25; 95% CI, 1.90-14.50; p=0.001) were significant risk factors for VPI in the pleural contact group. Conclusion: In patients with clinical stage I lung adenocarcinoma exhibiting pleural contact, pCEA and SUVmax are potential predictive indicators of VPI. These markers may be helpful in planning for lung cancer surgery.

Characterization of Nitrogen-Doped $TiO_2$ Thin Films Prepared by Metalorganic Chemical Vapor Deposition (유기금속 화학 기상증착법으로 실리콘 기판위에 증착된 질소치환 $TiO_2$ 박막의 특성분석)

  • 이동헌;조용수;이월인;이전국;정형진
    • Journal of the Korean Ceramic Society
    • /
    • 제31권12호
    • /
    • pp.1577-1587
    • /
    • 1994
  • TiO2 thin films with the substitution of oxygen with nitrogen were deposited on silicon substrate by metalorganic chemical vapor deposition (MOCVD) using Ti(OCH(CH3)2)4 (titanium tetraisopropoxide, TTIP) and N2O as source materials. X-ray diffraction (XRD) results indicated that the crystal structure of the deposited thin films was anatase TiO2 with only (101) plane observed at the deposition temperatures of 36$0^{\circ}C$ and 38$0^{\circ}C$, and with (101) and (200) plane at above 40$0^{\circ}C$. Raman spectroscopic results indicated that the crystal structure was anatase TiO2 in accordance with the XRD results without any rutile, fcc TiN, or hcp TiN structure. No fundamental difference was observed with temperature increase, but the peak intensity at 194.5 cm-1 increased with strong intensity at 143.0 cm-1 for all samples. The crystalline size of the films varied from 49.2 nm to 63.9 nm with increasing temperature as determined by slow-scan XRD experiments. The refractive index of the films increased from 2.40 to 2.55 as temperature increased. X-ray photoelectron spectroscopy (XPS) study showed only Ti 2s, Ti 2p, C 1s, O 1s and O 2s peaks at the surface of the film. The composition of the surface was estimated to be TiO1.98 from the quatitative analysis. In the bulk of the film Ti 2s, Ti 2p, O 1s, O 2s, N 1s and N 2s were detected, and Ti-N bonding was observed due to the substitution of oxygen with nitrogen. A satellite structure was observed in the Ti 2p due to the Ti-N bonding, and the composition of titanium nitride was determined to be about TiN1.0 from the position of the binding energy of Ti-N 2p3/2 and the quatitative analysis. The spectrum of Ti 2p energy level could be the sum of a 4, 5, or 6 Gaussian curve reconstruction, and the case of the sum of the 6 Gaussian curve reconstruction was physically most meaningful. From the results of Auger electron spectroscopy (AES), it was known that the composition was not varied significantly throughout the whole thickness of the film, and silicon oxide was not observed at the interface between the film and the substrate. The composition of the film was possible (TiO2)1-x.(TiN)x or TiO2-2xNx and in this experimental condition x was found to be about 0.21-0.16.

  • PDF

A CHARACTERIZATION OF HYPERBOLIC SPACES

  • Kim, Dong-Soo;Kim, Young Ho;Lee, Jae Won
    • Bulletin of the Korean Mathematical Society
    • /
    • 제55권4호
    • /
    • pp.1103-1107
    • /
    • 2018
  • Let M be a complete spacelike hypersurface in the (n + 1)-dimensional Minkowski space ${\mathbb{L}}^{n+1}$. Suppose that every unit speed curve X(s) on M satisfies ${\langle}X^{\prime\prime}(s),X^{\prime\prime}s){\rangle}{\geq}-1/r^2$ and there exists a point $p{\in}M$ such that for every unit speed geodesic X(s) of M through the point p, ${\langle}X^{\prime\prime}(s),X^{\prime\prime}s){\rangle}=-1/r^2$ holds. Then, we show that up to isometries of ${\mathbb{L}}^{n+1}$, M is the hyperbolic space $H^n(r)$.

Assessment of Pollution Levels in the Jangsungcheon Watershed Using Load Duration Curves and Analysis of the Causes

  • Cho, Sohyun;Bak, Jonghun;Lee, Yeong Jae;Kim, Kyunghyun;Jung, Kang Young
    • Journal of Environmental Science International
    • /
    • 제28권10호
    • /
    • pp.873-885
    • /
    • 2019
  • In this study, a load duration curve was applied to the Jangseongcheon, one of the tributaries of the Yeongsan River, to assess whether the target water quality was achieved. In addition, pollution of the water body was investigated to develop and suggest the optimal management time with respect to polluted flow sections and monthly conditions. The average flow rates of sections JS1 and JS2 were $0.25m^3/s$ and $1.08m^3/s$, respectively. The BOD and T-P for water-quality standards at JS1 were rated at II, whereas the COD and TOC were rated at III, thus indicating a fair level of water quality. By contrast, the BOD at JS2 was rated at III, the T-P at IV, and the TOC at V, indicating poor water quality in this section. The load duration curve was plotted using the actual flow data measured in eight-day intervals for eight years from 2011 to 2018 at locations JS1 and JS2 in the Jangsungcheon Basin. In an assessment using the load duration curve on whether the target water quality was met at location JS1, all of the water quality parameters (BOD, COD, TOC, T-N, T-P, and SS) satisfied the target water quality. By contrast, at location JS2, parameters COD, TOC, T-N, and T-P exceeded target values by more than 50%, indicating the target water quality was not met. The discharge loads of locations JS1 and JS2 were analyzed to identify the reasons the target water quality was exceeded. Results revealed that the land system contributed considerably. Furthermore, the discharge load of JS2 accounted for more than 80% of the load on the entire basin, excluding that of JS1. Therefore, the best method for restraining the inflow of pollutants into the stream near location JS2 must be applied to manage the water quality of the Jangsungcheon.

A Study on the Knee Point of Low-cycle Fatigue Life in High Formability Titanium Alloy SP-700 (티탄계 초소성합금 SP-700의 저사이클 피로수명곡선의 절곡현상에 대하여)

  • ;淸水 眞佐男
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제5권1호
    • /
    • pp.129-135
    • /
    • 1997
  • Previous studies has shown that the curve of low-cycle fatigue life was not expressed with the single line subjected to Manson-Coffin's law type and bent to short life in low ${\Delta}{\varepsilon}_p$ region. The main cause of this phenomenon has been considered that the localization of plastic strain in the crack initiation process fosters the crack initiation. In this study, the low-cycle fatigue life was investigated for each specimens omitted crack initiation process and it was found that fatigue life curve in log(${\Delta}{\varepsilon}_p$)-log($N_f$)was bent in low ${\Delta}{\varepsilon}_p$ region as ever. Therefore, the main cause of appearance of knee point in fatigue life curve is not found in the crack initiation process but in the crack propagation process. In the crack propagation process, the localization of the plastic strain in the vicinity of crack tip and the influence of test environment on the crack propagation rate were observed and these inclinations were more remarkable in low ${\Delta}{\varepsilon}_p$ region. Hence, it was concluded that these two phenomena in the crack propagation process were proved to the main cause which accelerates the crack propagation in low ${\Delta}{\varepsilon}_p$ region and bent the fatigue life curve in result.

  • PDF

Microstructure, Tensile Strength and Probabilistic Fatigue Life Evaluation of Gray Cast Iron (회주철의 미세구조와 인장거동 분석 및 확률론적 피로수명평가)

  • Sung, Yong Hyeon;Han, Seung-Wook;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제41권8호
    • /
    • pp.721-728
    • /
    • 2017
  • High-grade gray cast iron (HCI350) was prepared by adding Cr, Mo and Cu to the gray cast iron (GC300). Their microstructure, mechanical properties and fatigue strength were studied. Cast iron was made from round bar and plate-type castings, and was cut and polished to measure the percentage of each microstructure. The size of flake graphite decreased due to additives, while the structure of high density pearlite increased in volume percentage improving the tensile strength and fatigue strength. Based on the fatigue life data obtained from the fatigue test results, the probability - stress - life (P-S-N) curve was calculated using the 2-parameter Weibull distribution to which the maximum likelihood method was applied. The P-S-N curve showed that the fatigue strength of HCI350 was significantly improved and the dispersion of life data was lower than that of GC300. However, the fatigue life according to fatigue stress alleviation increased further. Data for reliability life design was presented by quantitatively showing the allowable stress value for the required life cycle number using the calculated P-S-N curve.

Aquatic Plants for Wastewater Treatment (수생식물을 이용한 수질정화에 관한 연구)

  • 나규환;권성환;이장훈
    • Journal of Environmental Health Sciences
    • /
    • 제22권3호
    • /
    • pp.49-55
    • /
    • 1996
  • Water parsley(Oenanthe javanica(Blume) DC) was raised with varying population density(S) in the laboratory aquarium unit to determine the growth equation. The population density was measure after 7 days. The resultant growth curve was well fit to the equation 1/S = A+B (1/S0) with a high correlation coefficient ($R^2$ = 0.999). The maximum specific absorption rate was $9.011 \times 10^{-5}$ kg $NO_x-N/kg$ water parsley$\cdot$day and $1.31 \times 10^{-5}$ kg $PO_4-P/kg$ water parsley$\cdot$day when the average population density was $2.62 kg/m^2$. The relationship between population density and nutrient absorption rate, the absorption rate of $NO_x-N$ was 5.04~5.24 mg/l$\cdot$day when the population density was $7.51~10.0 $mg/m^2\cdot day$ and the absorption rate of $PO_4-P$ was 0.56~0.78 mg/l$\cdot$day when the population density was 5.02~10.0 $kg/m^2\cdot day$. Taking into account the nutrient absorption rate and growth rate, the population density between $7.0 kg/m^2\cdot day$ and $8.0 kg/m^2 \cdot day$ was selected. The removal rate of nutrient was investigated after 7 days culture. Removal rate of $NO_x-N$ was 95.6~99.95% with initial concentration of 35 mg $NO_x-N/l$, and the removal rate of $PO_4-P$ was also high, indicating 80.24~98.9% with initial concentration of 5.95 mg $PO_x-P/l$.

  • PDF

Bonding and debonding behavior of FRP sheets under fatigue loading

  • Iwashita, Kentaro;Wu, Zhishen;Ishikawa, Takashi;Hamaguchi, Yasumasa;Suzuki, Toshio
    • Advanced Composite Materials
    • /
    • 제16권1호
    • /
    • pp.31-44
    • /
    • 2007
  • The purpose of this study is to improve the examining and understanding of the bonding behavior of Fiber Reinforced Polymer (FRP) sheets bonded to concrete blocks and steel plates under fatigue loading. First, a series of experimental investigations is summarized in the paper. The fatigue behavior of bonding surface between FRP sheets and concrete is finally characterized by the conducted P-S-N diagram representing the relationship among the probability of FRP debonding (P), the bond stress amplitudes (S), and the number of cycles (N) at debonding on a semi-logarithmic scale. The different debonding modes for various fracturing surface are also investigated and evaluated.

A Study on the Fatigue Fracture Behavior in Butt Welded Joints of Steel Structures (강구조물(鋼構造物) 맞대기 용접연결부(鎔接連結部)의 피로파괴거동(疲勞破壞擧動)에 관한 연구(硏究))

  • Park, Je Seon;Chung, Yeong Wha;Kim, Jeong Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제6권3호
    • /
    • pp.53-62
    • /
    • 1986
  • For the research on the fatigue fracture behavior in the welded joints of steel structures, base metal specimens and welded ones were selected, and the direct fatigue tests were carried out. Thereafter, fatigue-life (S-N) curves, plastic strain-number of cycles (${\varepsilon}_p$-N) curve, the extrapolated fatigue-life (${\varepsilon}_p$-$N_c$) curve, and da/dN-${\Delta}K$ curves were plotted. By these results the followings were obtained. It was shown that the ratio of fatigue strength at $2{\times}10^6$ cycles of the welded specimen to that of the base metal one was 0.6, and that 0.72 for the base metal and 0.65 for the welded one were the ratio of fatigue strength at $2{\times}10^6$ cycles to yielding stress. The S-N curve for the welded specimen was separated into two sections, the low gradient section and the steep section. As this result, it was shown that the more stress became to reduce, the more the reduction of fatigue strength became to be great. It was shown that fatigue strength at $2{\times}10^6$ cycles from this case was about 83 % of that from the S-N curve plotted with one section. It was thought that the reason was that weld flaw acted greatly on the fatigue strength within the low stress range. It was shown that at the instart of crack initiation plastic strain increased abrupt1y in the case of the welded specimen more than the case of the base metal specimen, and increased abruptly in the upper stress range in both cases. It was shown that the experimental constant ${\alpha}$, 0.42, in the base metal nearly accorded with Manson-Coffin's result, but this made a great difference with the case in the welded specimen. It was thought that it was due to the abrupt change of plastic strain and the influence of weld flaw.

  • PDF