• Title/Summary/Keyword: P-e curve

Search Result 271, Processing Time 0.027 seconds

Application of Principle in Metal-Ligand Complexation to Remove Heavy Metals : Effects of Metal Concentration, pH and Temperature (금속(金屬)-Ligand 착염형성(錯鹽形成)에 의한 중금속(重金屬) 제거방법(除去方法)에 관(關)한 연구(硏究) : 중금속(重金屬) 농도(濃度), pH 및 온도(溫度)의 효과(效果))

  • Yang, Jae-E;Shin, Yong-Keon;Kim, Jeong-Je
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.1
    • /
    • pp.37-42
    • /
    • 1993
  • Influences of metal concentration, pH and temperature on metal-ligand precipitate formation were investigated, as a part of projects for removing heavy metals from aqueous solution employing the principles in metal-ligand complexation. Aqueous solutions of HA or FA were reacted with those of heavy metals with 1:1 ratio. Efficiency of humic (HA) or fulvic acid (FA) on removing metals was evaluated by separating the precipitates from soltuions with the filtering method. When HA was a counter ligand, there existed three ranges of metal concentrations affecting precipitation : precipitate fromation was not available, was reached to the maximum, and afterwards was decreased again. The concentration ratios of metal to HA for initiating complexation were dependent upon kinds of metal and concentrations of ligand. Amount of Pb to form maximum precipitates per unit mg of HA was 1.3 times higher than that of Cu. When FA was a counter ligand, concentrations of metal-FA precipitates were increased proportionally with the treated metal concentrations. Efficiency of FA fro removing Pb was nearly 100%, but it was ranged from 12 to 19% for Cu, depending on FA concentration. pH exerted a considerable effect on complexation between Pb and FA, showing precipitates were increased six times at most per unit increase of pH. Ranges of pH increasing significantly the mounts of precipitates were coincied with pH jump ranges of the titration curve of organic ligands. As increasing temperature from 15 to $55^{\circ}C$, increases of FA-Cu precipitates were doubled, but those of FA-Pb were accounted for only 6%, However, HA-metal complexation was not affected by temperature.

  • PDF

Metarercariae of Echinochusmus japonicus Encysted in a Fresh Water Fibh, Pseudorasboru purva, and Their Development in Experimental Mice (참붕어(Pseudorasbora parva)에서 분리한 Echinochasmus japonicus 피낭유충 및 마우스 실험감염)

  • 제종일;홍성종
    • Parasites, Hosts and Diseases
    • /
    • v.23 no.2
    • /
    • pp.221-229
    • /
    • 1985
  • The echinostomatid metacercariae encysted in the gill of the fresh water fish, Pseudorasbora larva were identified through obtaining adult worms after eBperimental infection to mice. In addition, a brief course of worm development and maturation was observed in this experimental host. The results were as follows: 1. The echinostomatid metacercariae were elliptical, golden yellow, 0.073∼0.078 mm long and 0.0541∼0.065 mm wide. Their head portions were characterized by the presence of a head crown armed with collar spines of total 24 in number and interrupted at the mid-dorsal side of the oral sucker. 2. The average rate of worm recovery froth 12 mice (on the 1-2lth postinfection days) was 19.4 % and the rate revealed no decrease in accordance with the increase of infection duration. The worms were collected chiefly from the lower part of the small intestine. 3. After the infection, their sexual maturation was attained in 5 days and their growth in size nearly completed in 7 days. The early growth curve of genital organs was S shape while that of nongenital organs was C form. In 5 day old worms, 1 or 2 eggs were found from their uteri and the stools of mice revealed echinostomatid eggs from the 5-6th postinfection day. 4. The 7 day old adult worms were ovoid in shape, 0.54-0.69 mm long and 0.29-0.34 mm wide, and characterized by a well developed head crown with 24 collar spines and vitelline follicles distributed from the acetabular level down to the posterior end of body. Based on these characters they were identified to be Echinochasmus japonicus Tanabe, 1926. From these results, it is verified that p. larva is one of the second intermediate hosts of 5. jatonicus in Korea.

  • PDF

The Optimal Tumor Mutational Burden Cutoff Value as a Novel Marker for Predicting the Efficacy of Programmed Cell Death-1 Checkpoint Inhibitors in Advanced Gastric Cancer

  • Jae Yeon Jang;Youngkyung Jeon ;Sun Young Jeong ;Sung Hee Lim ;Won Ki Kang;Jeeyun Lee ;Seung Tae Kim
    • Journal of Gastric Cancer
    • /
    • v.23 no.3
    • /
    • pp.476-486
    • /
    • 2023
  • Purpose: The optimal tumor mutational burden (TMB) value for predicting treatment response to programmed cell death-1 (PD-1) checkpoint inhibitors in advanced gastric cancer (AGC) remains unclear. We aimed to investigate the optimal TMB cutoff value that could predict the efficacy of PD-1 checkpoint inhibitors in AGC. Materials and Methods: Patients with AGC who received pembrolizumab or nivolumab between October 1, 2020, and July 27, 2021, at Samsung Medical Center in Korea were retrospectively analyzed. The TMB levels were measured using a next-generation sequencing assay. Based on receiver operating characteristic curve analysis, the TMB cutoff value was determined. Results: A total 53 patients were analyzed. The TMB cutoff value for predicting the overall response rate (ORR) to PD-1 checkpoint inhibitors was defined as 13.31 mutations per megabase (mt/Mb) with 56% sensitivity and 95% specificity. Based on this definition, 7 (13.2%) patients were TMB-high (TMB-H). The ORR differed between the TMB-low (TMB-L) and TMB-H (8.7% vs. 71.4%, P=0.001). The progression-free survival and overall survival (OS) for 53 patients were 1.93 (95% confidence interval [CI], 1.600-2.268) and 4.26 months (95% CI, 2.992-5.532). The median OS was longer in the TMB-H (20.8 months; 95% CI, 2.292-39.281) than in the TMB-L (3.31 months; 95% CI, 1.604-5.019; P=0.049). Conclusions: The TMB cutoff value for predicting treatment response in AGC patients who received PD-1 checkpoint inhibitor monotherapy as salvage treatment was 13.31 mt/Mb. When applying the programmed death ligand-1 status to TMB-H, patients who would benefit from PD-1 checkpoint inhibitors can be selected.

Development of a rapid HPLC method for the determination of penciclovir in human plasma using a monolithic column and its application to a bioequivalence study (모노리틱 칼럼을 이용한 혈장 중 펜시를로버의 HPLC 신속분석법 개발 및 이를 이용한 생물학적동등성시험)

  • Kim, Jin Hee;Park, Ah Yeon;Jung, Eun Ha;Lee, Cheol Woo;Lee, Tae Ho;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.323-330
    • /
    • 2007
  • A simple and rapid HPLC method with fluorescence detection(FLD) for quantitation of penciclovir in human plasma using a monolithic column was developed and validated. Penciclovir and ganciclovir(internal standard, I.S.) were separated on a Chromolith column RP-18e ($4.6{\times}100mm$) with a mobile phase consisting of a mixture of (A) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (3/97, pH 2.5) and (B) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (50/50, pH 2.5) at a flow gradient of $1.6{\sim}4.0mL/min$. The retention times of penciclovir and internal standard were less than 4.0 min. Calibration curve was linear ($R^2=0.9994$) over a concentration range of $0.1{\sim}5{\mu}g/mL$. Intra-day precision, accuracy and inter-day precision were 1.36~8.55 %, 92.8~100.0 % and 0.93~5.62 %, respectively with a limit of quantitation at $0.1{\mu}g/mL$. The present HPLC-FLD method is sensitive, precise and accurate. The method described herein has been successfully used for the bioequivalence study of a famciclovir formulation product after oral administration to healthy Korean volunteers.

Towards Efficient Aquaculture Monitoring: Ground-Based Camera Implementation for Real-Time Fish Detection and Tracking with YOLOv7 and SORT (효율적인 양식 모니터링을 향하여: YOLOv7 및 SORT를 사용한 실시간 물고기 감지 및 추적을 위한 지상 기반 카메라 구현)

  • TaeKyoung Roh;Sang-Hyun Ha;KiHwan Kim;Young-Jin Kang;Seok Chan Jeong
    • The Journal of Bigdata
    • /
    • v.8 no.2
    • /
    • pp.73-82
    • /
    • 2023
  • With 78% of current fisheries workers being elderly, there's a pressing need to address labor shortages. Consequently, active research on smart aquaculture technologies, centered on object detection and tracking algorithms, is underway. These technologies allow for fish size analysis and behavior pattern forecasting, facilitating the development of real-time monitoring and automated systems. Our study utilized video data from cameras outside aquaculture facilities and implemented fish detection and tracking algorithms. We aimed to tackle high maintenance costs due to underwater conditions and camera corrosion from ammonia and pH levels. We evaluated the performance of a real-time system using YOLOv7 for fish detection and the SORT algorithm for movement tracking. YOLOv7 results demonstrated a trade-off between Recall and Precision, minimizing false detections from lighting, water currents, and shadows. Effective tracking was ascertained through re-identification. This research holds promise for enhancing smart aquaculture's operational efficiency and improving fishery facility management.

Studies on the Derivation of the Instantaneous Unit Hydrograph for Small Watersheds of Main River Systems in Korea (한국주요빙계의 소유역에 대한 순간단위권 유도에 관한 연구 (I))

  • 이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.1
    • /
    • pp.4296-4311
    • /
    • 1977
  • This study was conducted to derive an Instantaneous Unit Hydrograph for the accurate and reliable unitgraph which can be used to the estimation and control of flood for the development of agricultural water resources and rational design of hydraulic structures. Eight small watersheds were selected as studying basins from Han, Geum, Nakdong, Yeongsan and Inchon River systems which may be considered as a main river systems in Korea. The area of small watersheds are within the range of 85 to 470$\textrm{km}^2$. It is to derive an accurate Instantaneous Unit Hydrograph under the condition of having a short duration of heavy rain and uniform rainfall intensity with the basic and reliable data of rainfall records, pluviographs, records of river stages and of the main river systems mentioned above. Investigation was carried out for the relations between measurable unitgraph and watershed characteristics such as watershed area, A, river length L, and centroid distance of the watershed area, Lca. Especially, this study laid emphasis on the derivation and application of Instantaneous Unit Hydrograph (IUH) by applying Nash's conceptual model and by using an electronic computer. I U H by Nash's conceptual model and I U H by flood routing which can be applied to the ungaged small watersheds were derived and compared with each other to the observed unitgraph. 1 U H for each small watersheds can be solved by using an electronic computer. The results summarized for these studies are as follows; 1. Distribution of uniform rainfall intensity appears in the analysis for the temporal rainfall pattern of selected heavy rainfall event. 2. Mean value of recession constants, Kl, is 0.931 in all watersheds observed. 3. Time to peak discharge, Tp, occurs at the position of 0.02 Tb, base length of hlrdrograph with an indication of lower value than that in larger watersheds. 4. Peak discharge, Qp, in relation to the watershed area, A, and effective rainfall, R, is found to be {{{{ { Q}_{ p} = { 0.895} over { { A}^{0.145 } } }}}} AR having high significance of correlation coefficient, 0.927, between peak discharge, Qp, and effective rainfall, R. Design chart for the peak discharge (refer to Fig. 15) with watershed area and effective rainfall was established by the author. 5. The mean slopes of main streams within the range of 1.46 meters per kilometer to 13.6 meter per kilometer. These indicate higher slopes in the small watersheds than those in larger watersheds. Lengths of main streams are within the range of 9.4 kilometer to 41.75 kilometer, which can be regarded as a short distance. It is remarkable thing that the time of flood concentration was more rapid in the small watersheds than that in the other larger watersheds. 6. Length of main stream, L, in relation to the watershed area, A, is found to be L=2.044A0.48 having a high significance of correlation coefficient, 0.968. 7. Watershed lag, Lg, in hrs in relation to the watershed area, A, and length of main stream, L, was derived as Lg=3.228 A0.904 L-1.293 with a high significance. On the other hand, It was found that watershed lag, Lg, could also be expressed as {{{{Lg=0.247 { ( { LLca} over { SQRT { S} } )}^{ 0.604} }}}} in connection with the product of main stream length and the centroid length of the basin of the watershed area, LLca which could be expressed as a measure of the shape and the size of the watershed with the slopes except watershed area, A. But the latter showed a lower correlation than that of the former in the significance test. Therefore, it can be concluded that watershed lag, Lg, is more closely related with the such watersheds characteristics as watershed area and length of main stream in the small watersheds. Empirical formula for the peak discharge per unit area, qp, ㎥/sec/$\textrm{km}^2$, was derived as qp=10-0.389-0.0424Lg with a high significance, r=0.91. This indicates that the peak discharge per unit area of the unitgraph is in inverse proportion to the watershed lag time. 8. The base length of the unitgraph, Tb, in connection with the watershed lag, Lg, was extra.essed as {{{{ { T}_{ b} =1.14+0.564( { Lg} over {24 } )}}}} which has defined with a high significance. 9. For the derivation of IUH by applying linear conceptual model, the storage constant, K, with the length of main stream, L, and slopes, S, was adopted as {{{{K=0.1197( {L } over { SQRT {S } } )}}}} with a highly significant correlation coefficient, 0.90. Gamma function argument, N, derived with such watershed characteristics as watershed area, A, river length, L, centroid distance of the basin of the watershed area, Lca, and slopes, S, was found to be N=49.2 A1.481L-2.202 Lca-1.297 S-0.112 with a high significance having the F value, 4.83, through analysis of variance. 10. According to the linear conceptual model, Formular established in relation to the time distribution, Peak discharge and time to peak discharge for instantaneous Unit Hydrograph when unit effective rainfall of unitgraph and dimension of watershed area are applied as 10mm, and $\textrm{km}^2$ respectively are as follows; Time distribution of IUH {{{{u(0, t)= { 2.78A} over {K GAMMA (N) } { e}^{-t/k } { (t.K)}^{N-1 } }}}} (㎥/sec) Peak discharge of IUH {{{{ {u(0, t) }_{max } = { 2.78A} over {K GAMMA (N) } { e}^{-(N-1) } { (N-1)}^{N-1 } }}}} (㎥/sec) Time to peak discharge of IUH tp=(N-1)K (hrs) 11. Through mathematical analysis in the recession curve of Hydrograph, It was confirmed that empirical formula of Gamma function argument, N, had connection with recession constant, Kl, peak discharge, QP, and time to peak discharge, tp, as {{{{{ K'} over { { t}_{ p} } = { 1} over {N-1 } - { ln { t} over { { t}_{p } } } over {ln { Q} over { { Q}_{p } } } }}}} where {{{{K'= { 1} over { { lnK}_{1 } } }}}} 12. Linking the two, empirical formulars for storage constant, K, and Gamma function argument, N, into closer relations with each other, derivation of unit hydrograph for the ungaged small watersheds can be established by having formulars for the time distribution and peak discharge of IUH as follows. Time distribution of IUH u(0, t)=23.2 A L-1S1/2 F(N, K, t) (㎥/sec) where {{{{F(N, K, t)= { { e}^{-t/k } { (t/K)}^{N-1 } } over { GAMMA (N) } }}}} Peak discharge of IUH) u(0, t)max=23.2 A L-1S1/2 F(N) (㎥/sec) where {{{{F(N)= { { e}^{-(N-1) } { (N-1)}^{N-1 } } over { GAMMA (N) } }}}} 13. The base length of the Time-Area Diagram for the IUH was given by {{{{C=0.778 { ( { LLca} over { SQRT { S} } )}^{0.423 } }}}} with correlation coefficient, 0.85, which has an indication of the relations to the length of main stream, L, centroid distance of the basin of the watershed area, Lca, and slopes, S. 14. Relative errors in the peak discharge of the IUH by using linear conceptual model and IUH by routing showed to be 2.5 and 16.9 percent respectively to the peak of observed unitgraph. Therefore, it confirmed that the accuracy of IUH using linear conceptual model was approaching more closely to the observed unitgraph than that of the flood routing in the small watersheds.

  • PDF

Isolation and Characterization of Lactic acid bacteria Leuconostoc mesenteroides DB3 from Camellia japonica Flower (백꽃으로부터 분리한 Leuconostoc mesenteroides DB3의 특성)

  • Sam Woong Kim;Da Hye Shin;Sang Wan Gal;Kyu Ho Bang;Da Som Kim;Won-Jae Chi
    • Journal of Life Science
    • /
    • v.33 no.11
    • /
    • pp.915-922
    • /
    • 2023
  • Lactic acid bacteria (LAB) are widespread in a variety of environments including fermented dairy products, gastroinstetinal and urogenital tracts of human and animals, plant, soil and water. Leuconostoc mesenteroides DB3 was detected by the strongest antibacterial activities among 24 Leuconostoc strains isolated from Camellia japonica flowers. Acid tolerance of L. mesenteroides DB3 existed up to pH 2.5, but the resistance did not show at pH 2.0, which relatively excellent acid resistance existed. Bile acid tolerance was very stable within the test range to 1.2%. L. mesenteroides DB3 exhibited the optimal growth at 30℃, and showed a slight slow growth when compared with L. mesenteroides KCTC3505, which reached a stationary phase at 18 hr. The pH was changed along with the growth curve, but was maintained above pH 3.98. L. mesenteroides DB3 had higher initial antibacterial activities when compared to L. mesenteroides KCTC3505, but it showed similar activities with the standard strain after the latter part of the logarithmic growth phase. Although lactic acid production in L. mesenteroides DB3 was induced by lower amount in the initial part to the standard strain, it was exhibited by similar amounts after the late logarithmic growth phase. Muicin adhesion of L. mesenteroides DB-3 maintained superior to L. mesenteroides KCTC3505. Both strains showed excellent emulsification ability for kerosene. In summary, we evaluate that L. mesenteroides DB-3 has a high potential for application as probiotics owing to its excellent antibacterial activity, acid resistance, bile acid resistance, and muicin adhesion.

Reevaluation of Lane Width Widenings on Horizontal Curve Sections (평면곡선부 확폭량 재설정에 관한 연구)

  • 최재성;백종대
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.4
    • /
    • pp.51-62
    • /
    • 2000
  • The objective of this study was to reevaluate current Korean design values for lane width widenings on horizontal currie sections and to develop a new method for derivation of design values based on low-speed offtracking. For this purpose, earlier research were reviewed and necessary equations were derived. Also, the method for derivation of widening values of Korea was compared with that for other countries. The result showed that present Korean method could not consider the variation of lane widths and design speeds of roads. In this Paper, to solve such problems, the new concept of widening was developed. That is the current concept of widening which concerns only the dimension of vehicles and radius of curves was replaced by a new concept that lane width widenings on horizontal curve sections is the difference between the width required on curries and tangents. The width required on a curve consists of the swept Path of a vehicle, lateral clearance, and additional allowance. The width of a tangent is calculated by multiplying lane width by the number of lanes The result of applying new concept shows that the values derived from new concept are higher than current design values for curries have same radius. This study was based only on low-speed offtracking. Therefor, it is recommended that further studies which consider the superelevation and high-speed effect on offtracking be made to derive more accurate widening values .

  • PDF

Analysis of Thermal Conductivities of Carbon/Phenolic and Silica/Phenolic Ablative Composites by Laser Pulse Method (레이저 섬광법을 이용한 Carbon/Phenolic 및 Silica/Phenolic 내열복합재료의 열전도도 분석)

  • Kim, H.Y.;Kim, P.W.;Hong, S.H.;Kim, Y.C.;Yeh, B.H.;Jung, B
    • Composites Research
    • /
    • v.12 no.3
    • /
    • pp.75-83
    • /
    • 1999
  • The thermal properties of carbon/phenolic and silica/phenolic ablative composites were investigated by measuring the heat capacity, thermal diffusivity and thermal conductivity. The heat capacities of carbon/ phenolic and silica/phenolic composites were calculated from differential scanning calorimeter curve. The thermal diffusivities of carbon/phenolic and silica/phenolic composites were measured by the laser flash method with varying laminated direction, i.e., with laminar direction and across laminar direction. The thermal diffusivities decreased with increasing temperature. The thermal conductivities of carbon/phenolic and silica/phenolic composites were calculated using the heat capacity, density and thermal diffusivity. The thermal conductivities increased with increasing temperature. The thermal conductivity of with laminar direction is two times higher than that of across-laminar direction in carbon/phenolic composite due to the directionality of thermal conductivity of carbon fiber. The thermal conductivities of two dimensional fiber reinforced composites were analyzed using the conductivities of constituents and volume fraction of each constituent. The thermal conductivities of carbon fiber and silica fiber were calculated from thermal conductivities of carbon/phenolic and silica/phenolic composites. The thermal conductivities of carbon/phenolic and silica/phenolic composites at RT were predicted from thermal conductivities of fiber and resin with varying the volume fraction of fiber.

  • PDF

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF