• Title/Summary/Keyword: P-base

Search Result 2,509, Processing Time 0.027 seconds

Study of the Device Characteristics of The Base Resistance Controlled Thyristor With The Self-Align Corrugated P-base (자기정렬된 물결모양 P-베이스를 갖는 베이스 저항 제어 사이리스터의 소자특성에 관한 연구)

  • Lee, Yu-Sang;Byeon, Dae-Seok;Lee, Byeong-Hun;Kim, Du-Yeong;Han, Min-Gu;Choe, Yeon-Ik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.3
    • /
    • pp.167-172
    • /
    • 1999
  • The device characteristics of the base resistance controlled thyristor with self-align corrugated p-base is demonstrated for the first time with varying the n+ cathode width and the temperature form room temperature to $125^{\circ}C$. The experimental results show that the snap-back in the CB-BRT is significantly suppressed irrespective of the various n+ cathode width and the temperature as compared with that of the conventional BRT. The maximum controllable current of the CB-BRT is uniformly higher when compared with that of the conventional BRT over the temperature range from room temperature to $125^{\circ}C$.

  • PDF

A COMPARATIVE STUDY OF BOND STRENGTH OF RECYCLED BRACKETS (재생 브라켓의 전단접착강도에 관한 비교 연구)

  • Shur, Cheong-Hoon;Choi, Eun-Ah
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.641-657
    • /
    • 1998
  • This study was undertaken to compare the bond strength and the fracture site of new and recycled brackets according to the base design. 252 sound premolars extracted for orthodontic treatment were collected and Type I, Type II, Type III brackets were divided into four groups by recycling method Each bracket was then bonded to an extracted premolar. Instron Universal Testing Machine(model W) was used to measure the shear bond strength, and the surface of the recycled brackets were viewed in SEM For the analysis of the results, one way ANOVA and Scheffe's multiple range test was executed using the SPSSWIN program. 1. The shear bond strength showed statistically significant difference according to the bracket base design(p<0.001). Type III bracket(round indentation base, micro-etched) showed the highest bond strength, Type I bracket(foil-mesh base) was second, and Type II bracket(grooved integral base, micro-etched) was last. 2. The effect of recycling on the bond strength was different according to bracket type. The shear bond strength of Type I, Type II brackets showed the smallist reduction when treated for 1 minute in Big Jane(p<0.05), but the shear bond strength of Type III brackets showed no statistically significant difference according to recycling method(p>0.05). 3. In Type I, Type II brackets, frequent fracture site was bracket-resin interface, but in Type III brackets, about half of the resin was retained on the tooth surface frequently. 4. The shear bond strength was highest when about half of the resin was retained on the tooth surface(p<0.05). 5. The resin remnant on the bracket base after recycling had no effect on the shear bond strength.

  • PDF

CYTOTOXICITY OF DENTURE BASE RESINS (의치상 레진의 세포독성에 관한 연구)

  • Kim Seong-Kyun;Chang Ik-Tae;Heo Seong-Joo;Keak Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.309-322
    • /
    • 2002
  • The purpose of this study was to investigate the cytotoxicity and mutagenicity of denture base resins. According to manufacturer's instructions, resin specimens were made. Group 1 : heat-polymerizing acrylic resin (Luciton $199^{(R)}$) Group 2 : heat-polymerizing acrylic resin containing polyhedraloligosilsesquioxane(POSS resin) Group 3 : auto-polymerizing acrylic resin (Repair $Acrylic^{(R)}$) Group 4 : direct relining auto-polymerizing acrylic resin (Tokuso $Rebase^{(R)}$). Fresh specimens 24 hrs. and 72 hrs. soaked specimens in distil)ed water were made. Responses with metabolic assay and mutagenesis assay to eluates from resin specimens were measured. Cultures with medium alone provided controls. Cytotoxicity was assessed with agar overlay test. The results were as follows; 1. Group 4 showed higher cytotoxicity than Group 1, Group 2 and Group 3 in fresh, 24-an4 72-hour immersion caries (p<.05). Group 3 showed higher cytotoxicity than Group 2 in fresh cases and showed higher cytotoxicity than Group 1 and Group 2 in 24-and 72-hour immersion cases (p<.05) . Group 1 and Group 2 showed no significant difference. 2. All acrylic denture base resins skewed significant increase of cell activity as immersion time increased (p<.05). 3. Auto-polymerizing acrylic denture base resins skewed higher cytotoxicity than heat-polymerizing acrylic denture base resins (p<.05). 4. All acrylic denture base resins showed lower mutagenicity than controls (p<.05).

Nostril Base Augmentation Effect of Alveolar Bone Graft

  • Lee, Woojin;Park, Hyung Joon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.542-545
    • /
    • 2013
  • Background The aims of alveolar bone grafting are closure of the fistula, stabilization of the maxillary arch, support for the roots of the teeth adjacent to the cleft on each side. We observed nostril base augmentation in patients with alveolar clefts after alveolar bone grafting. The purpose of this study was to evaluate the nostril base augmentation effect of secondary alveolar bone grafting in patients with unilateral alveolar cleft. Methods Records of 15 children with alveolar clefts who underwent secondary alveolar bone grafting with autogenous iliac cancellous bone between March of 2011 and May of 2012 were reviewed. Preoperative and postoperative worm's-eye view photographs and reconstructed three-dimensional computed tomography (CT) scans were used for photogrammetry. The depression of the nostril base and thickness of the philtrum on the cleft side were measured in comparison to the normal side. The depression of the cleft side pyriform aperture was measured in comparison to the normal side on reconstructed three-dimensional CT. Results Significant changes were seen in the nostril base (P=0.005), the philtrum length (P=0.013), and the angle (P=0.006). The CT measurements showed significant changes in the pyriform aperture (P<0.001) and the angle (P<0.001). Conclusions An alveolar bone graft not only fills the gap in the alveolar process but also augments the nostril base after surgery. In this study, only an alveolar bone graft was performed to prevent bias from other procedures. Nostril base augmentation can be achieved by performing alveolar bone grafts in children, in whom invasive methods are not advised.

DNA Mediated Energy Transfer from 4',6-Diamidino-2-phenylindole to tetra- and bis-cationic Porphyrins at Low Binding Densities

  • Gong, Lindan;Ryu, Jae-Ki;Kim, Bok-Jo;Jang, Yoon-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.529-534
    • /
    • 2012
  • The fluorescence of 4',6-diamidino-2-phenylindole (DAPI) bound to DNA at a [DAPI]/[DNA base] ratio of 0.005 was quenched by meso-tetrakis(N-methylpyridinium-4-yl)porphyrin (TMPyP) or cis-bis(N-methylpyridinium-4-yl)porphyrin (BMPyP) when both DAPI and either porphyrin spontaneously bound to the same DNA strand. The quenching was investigated using the "one-dimensional inner sphere" and the "F$\ddot{o}$rster resonance energy transfer" (FRET) models. Total quenching occurred when DAPI and TMPyP were up to 19.3 base pairs or $66\AA$ apart. BMPyP could quench the fluorescence up to 13.9 base pairs or $47\AA$. TMPyP, which intercalated between the DNA base-pairs, appeared to be a better acceptor than BMPyP, which stacked along the DNA stem. The higher quenching and higher resonance energy transfer efficiency of TMPyP was due to the larger overlap integral between its absorption spectrum and the emission spectrum of DNA-bound DAPI.

Comparison of morphometric traits between small yellow croaker (Larimichthys polyactis) and yellow croaker(L. crocea) (참조기(Larimichthys polyactis)와 부세(L. crocea) 간의 외부계측형질 비교)

  • Park, In-Seok;Oh, Ji Su
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.4
    • /
    • pp.507-517
    • /
    • 2020
  • Several methods including morphometric analysis were used to distinguish small yellow croaker (Larimichthys polyactis) from yellow croaker (Larimichthys crocea), which have very similar external shapes. Morphometric analysis showed four considerable differences (p<0.05) among the total 48 morphometric dimensions, but no differences were seen in the classical dimensions (p>0.05). Rather, significant differences were seen in two truss dimensions: Insertion of dorsal fin base - origin of pectoral fin base and origin of anal fin base - origin of pectoral fin base, and two head part dimension: most anterior extension of the head - above of eye and above of eye - posterior aspect of operculum(p<0.05). However, the yellow croaker had higher values than the small yellow croaker in the other three morphometric dimensions except for the head part dimension of above of eye - posterior aspect of operculum of the four morphometric dimensions (p<0.05). The X-ray photographs indicated that the small yellow croaker (45.1±2.34°) had 8.4% more curved vertebral column than the yellow croaker(38.4±1.82°). A diamond-shaped cranium was found when the skin was peeled off from both fish but the commonly held fact that only the small yellow croaker has a diamond-shaped cranium is not accurate. Our results confirmed that the two fish could be definitely distinguished by their external body shape.

Content-based Extended CAN to Support Keyword Search (키워드 검색 지원을 위한 컨텐츠 기반의 확장 CAN)

  • Park, Jung-Soo;Lee, Hyuk-ro;U, Uk-dong;Jo, In-june
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.103-109
    • /
    • 2005
  • Research about P2P system have recently a lot of attention in connection of form that pass early Centralized P2P and is Decentralized P2P. Specially, Structured P2P System of DHT base have a attention to scalability and systematic search and high search efficiency by routing. But, Structured P2P System of DHT base have problem, file can be located only their unique File IDs that although user may wish to search for files using a set descriptive keyword or do not have the exact File ID of the files. This paper propose extended-CAN mechanism that creates File ID of Contents base and use KID and CKD for commonness keyword processing to support keyword search in P2P System of DHT base.

  • PDF

A STUDY OF THE STRESS TRANSMISSION OF VARIOUS ARTIFICIAL TEETH AND DENTURE BASE MATERIALS TO THE UNDER-LYING SUPPORTING TISSUES (인공치와 의치상의 재질에 따른 의치상 하부 지지조직에의 응력전달에 관한 연구)

  • Chung, Hyun-Gun;Chung, Moon-Kyu;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.79-100
    • /
    • 1989
  • The Purpose of this study was to investigate material differences in stress transmission among various artificial teeth and denture base materials. For this study, a two-dimensional finite element model and a two-dimensional photoelastic model of a mandible with complete denture were made. A resin tooth and a porcelain tooth were used as artificial teeth, and a resin base, a metal lined base, and a soft-liner lined base were used as denture bases. An occlusal load was applied and principal stresses generated in the supporting tissues were compared. To test the impact stress transmission, strain gauge attached to the denture base specimens made of the different materials were made in thick and thin groups. Voltage outputs from hitting the specimen with a steel ball were compared. The results were as follows : 1. In FEM, increasing the mucosal thickness reduced the maximum principal stresses in the supporting tissues, but altering the tooth materials and the base materials induced no difference in the stresses. 2. In photoelastic model study, no difference in fringe order among the specimens were observed, but the thick mucosa group and the soft-liner lined group revealed a more uniform distribution of the load. 3. In strain measuring, the impact force transmission was highest in the soft-liner lined group, and was the lowest in the metal lined group(p<0.01). 4. In the thin group using the resin base, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the thick group. In the soft-liner lined group, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the metal lined group. 5. The thick group showed lower impact stress transmission than the thin group(p<0.01).

  • PDF

Platybasia in 22q11.2 Deletion Syndrome Is Not Correlated with Speech Resonance

  • Spruijt, Nicole E.;Kon, Moshe;Molen, Aebele B. Mink Van Der
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.344-349
    • /
    • 2014
  • Background An abnormally obtuse cranial base angle, also known as platybasia, is a common finding in patients with 22q11.2 deletion syndrome (22q11DS). Platybasia increases the depth of the velopharynx and is therefore postulated to contribute to velopharyngeal dysfunction. Our objective was to determine the clinical significance of platybasia in 22q11DS by exploring the relationship between cranial base angles and speech resonance. Methods In this retrospective chart review at a tertiary hospital, 24 children (age, 4.0-13.1 years) with 22q11.2DS underwent speech assessments and lateral cephalograms, which allowed for the measurement of the cranial base angles. Results One patient (4%) had hyponasal resonance, 8 (33%) had normal resonance, 10 (42%) had hypernasal resonance on vowels only, and 5 (21%) had hypernasal resonance on both vowels and consonants. The mean cranial base angle was $136.5^{\circ}$ (standard deviation, $5.3^{\circ}$; range, $122.3-144.8^{\circ}$). The Kruskal-Wallis test showed no significant relationship between the resonance ratings and cranial base angles (P=0.242). Cranial base angles and speech ratings were not correlated (Spearman correlation=0.321, P=0.126). The group with hypernasal resonance had a significantly more obtuse mean cranial base angle ($138^{\circ}$ vs. $134^{\circ}$, P=0.049) but did not have a greater prevalence of platybasia (73% vs. 56%, P=0.412). Conclusions In this retrospective chart review of patients with 22q11DS, cranial base angles were not correlated with speech resonance. The clinical significance of platybasia remains unknown.

Optimization of 4H-SiC DMOSFETs by Adjustment of the Dimensions and Level of the p-base Region (P형 우물 영역의 도핑 농도와 면적에 따른 4H-SiC 기반 DMOSFET 소자 구조의 최적화)

  • Ahn, Jung-Joon;Bahng, Wook;Kim, Sang-Chul;Kim, Nam-Kyun;Jung, Hong-Bae;Koo, Sang-Mo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.513-516
    • /
    • 2010
  • In this work, a study is presented of the static characteristics of 4H-SiC DMOSFETs obtained by adjustment of the p-base region. The structure of this MOSFET was designed by the use of a device simulator (ATLAS, Silvaco.). The static characteristics of SiC DMOSFETs such as the blocking voltages, threshold voltages, on-resistances, and figures of merit were obtained as a function of variations in p-base doping concentration from $1\;{\times}\;10^{17}\;cm^{-3}$ to $5\;{\times}\;10^{17}\;cm^{-3}$ and doping depth from $0.5\;{\mu}m$ to $1.0\;{\mu}m$. It was found that the doping concentration and the depth of P-base region have a close relation with the blocking and threshold voltages. For that reason, silicon carbide DMOSFET structures with highly intensified blocking voltages with good figures of merit can be achieved by adjustment of the p-base depth and doping concentration.