• Title/Summary/Keyword: P-base

Search Result 2,517, Processing Time 0.032 seconds

Study about sacral base X-ray of Barge (Barge의 천골 기저부 X-ray에 대한 연구)

  • Min, Young-Kwang
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.1
    • /
    • pp.19-26
    • /
    • 2011
  • Objectives : The purpose of this study is to research the necessity of sacral base X-ray that Barge insisted. Methods : I have done a comparative analysis in side of short leg and side of sacral inferior with sacral base X-ray and pelvis A-P Xray pictures of 42 patients with lower back pain from December 1, 2010 to March 31, 2011. Results : Even though most of the subjects in study were male, 36 people had plateau of sacral base and 29 people had symmetry in sacral base X-ray. There was no statistical significance in the side of short leg and side of sacral base inferior in Sacral base X-ray, but there was a statistical significance in pelvis A-P x-ray. 22 people had same side of short leg and side of sacral base inferior in sacral base X-ray and pelvis A-P X-ray and 14 people didn't. 29 people had same side of sacral base inferior in sacral base X-ray and pelvis A-P X-ray and 13 people didn't. Conclusions : According to the result of the study, sacral base X-ray is necessary for correct sacral base inferior analysis.

  • PDF

The Comparison of Base Deficit, Lactate, and Strong Ion Gap as Early Predictor of Mortality in Trauma Patients (외상환자의 초기 사망 예측 지표로서의 내원 초기의 염기 결핍, 젖산 및 강이온 차이의 유용성 비교)

  • Park, Kyung Hye;Lee, Kang Hyun;Kim, Seon Hyu;Oh, Sung Bum;Moon, Joong Bum;Kim, Hyun;Hwang, Sung Oh;Kim, Heon Ju
    • Journal of Trauma and Injury
    • /
    • v.18 no.2
    • /
    • pp.127-134
    • /
    • 2005
  • Purpose: Currently, there is a variety of systems available for predicting prognosis of trauma patients such as trauma score, Injury severity score (ISS) and acid-base variables. But it is not clear that the initial acid-base variables are predictors of prognosis in trauma patients at the emergency department. The objective of this study is to compare the base deficit, lactate and strong ion gap as an early predictor of mortality in trauma patients. Methods: Retrospective record review of 136 trauma patients needed to admit to intensive care unit via emergency department (June 2004 to February 2005). Data included age, injury mechanism, ISS, Revised trauma score (RTS), Multiple organ dysfunction score (MODS), Acute physiology and chronic health evaluation III (APACHE III), Glasgow coma scale (GCS), laboratory profiles, calculated anion gap and strong ion gap. Patients were divided into survivors and non-survivors, shock group and non-shock group with comparison by t-test;significance was assumed for p<0.05. Correlation between acid-base variables and mean arterial blood pressure (MABP) was evaluated. Results: There was a significant difference between the RTS (p=0.00), APACHE III (p=0.00), MODS (p=0.00), GCS (p=0.00) of survivors and non-survivors. There was no significant difference between the ISS (p=0.082), lactate (p=0.541), base excess (p=0.468) and SIG (p=0.894) of survivors and non-survivors. There was a significant difference between the RTS (p=0.023), APACHE III (p=0.002), lactate (p=0.000), base excess (p=0.000) and SIG (p=0.000) of shock and non-shock group. There was no significant difference between the ISS (p=0.270), MODS (p=0.442) and GCS (p=0.432) of shock and non-shock group. The base excess was most correlated to MABP (r2=0.150). Conclusion: Initial base deficit, serum lactate and SIG are not predictors of mortality in moderate to severe trauma patients. Initial base deficit, serum lactate and SIG are correlated with the mean arterial blood pressure in trauma patients in emergency department.

Effects of Thermal and Mechanical Fatigue Stress on Bond Strength in Bracket Base Configurations (열적, 기계적 피로응력이 교정용 브라켓의 결합강도에 미치는 영향)

  • Kim, Jong-Ghee;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.625-642
    • /
    • 2000
  • The purpose of this study is to evaluate the effects of mechanical and thermal fatigue stress on the shear, tensile and shear-tensile combined bond strengths(SBS, TBS, CBS) in various orthodontic brackets bonded to human premolars with chemically cured adhesive(Ortho-one, Bisco, USA). Five types of commercially available metal brackets with various bracket base configurations of Photoetched base(Tomy, Japan), Non-Etched Foil Mesh base(Dentaurum, Germany), Micro-Etched Foil Mesh base(Ortho Organizers, USA), Chessboard base(Daesung, Korea), and Integral base(3M Unitek, USA) were used. Samples were divided into 3 groups, the first group was acted with shear-tensile combined loads($45^{\circ}$) of 200g for 4 weeks(mechanical fatigue stress), the second group was subjected to the 5,000 thermocycles of 15 second dwell time each in $5^{\circ}C\;and\;55^{\circ}C$ baths(thermal fatigue stress), and the third group was the control. Bond strengths were measured at the crosshead speed of 0.5mm/min. The cross-section of bracket base/adhesive interface and the fracture surface were examined with the stereoscope and the scanning electron microscope. The resin remnant on bracket base surface was assessed by ART(Adhesive Remnant Index). The obtained results were summarized as follows, 1. In static bond strength, Photoetched base bracket showed the maximum bond strength and Integral base bracket showed the minimum bond strength(p<0.05). In all brackets, shear bond strength(SBS) was in the greatest value and shear-tensile combined strength(CBS) was in the least value(p<0.05). 2. After mechanical fatigue test, Photoetched base bracket showed the maximum bond strength and Integral base bracket showed the minimum bond strength(p<0.05). In Photoetched base bracket and Micro-Etched Foil Mesh base bracket, shear bond strength(SBS), tensile bond strength(TBS) and shear-tensile combined strength(CBS) were decreased after mechanical fatigue test(p

  • PDF

Comparison of flexural strength according to thickness between CAD/CAM denture base resins and conventional denture base resins (CAD/CAM 의치상 레진과 열중합 의치상 레진의 두께에 따른 굴곡 강도 비교)

  • Lee, Dong-Hyung;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.183-195
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the flexural strength of CAD/CAM denture base resins with conventional denture base resins based on their thicknesses. Materials and Methods: For the conventional denture base resins, Lucitone 199® (C-LC) was used. DIOnavi - Denture (P-DO) and DENTCA Denture Base II (P-DC) were taken for the 3D printing denture base resins. For the prepolymerized PMMA resins, Vipi Block Gum (M-VP) and M-IVoBase® CAD (M-IV) were used. The final dimensions of the specimens were 65.0 mm x 12.7 mm x 1.6 mm / 2.0 mm / 2.5 mm. The 3-point bend test was implemented to measure the flexural strength and flexural modulus. Microscopic evaluation of surface of fractured specimen was conducted by using a scanning electron microscope (SEM). After testing the normality of the data, one-way ANOVA was adopted to evaluate the differences among sample groups with a significance level of P = 0.05. The Tukey HSD test was performed for post hoc analysis. Results: Under the same thicknesses, there are significant differences in flexural strength between CAD/CAM denture base resins and conventional denture base resins except for P-DO and C-LC. M-VP showed higher flexural strength than conventional denture base resins, P-DC and M-IV displayed lower flexural strength than conventional denture base resins. Flexural modulus was highest in M-VP, followed by C-LC, P-DO, P-DC, M-IV, significant differences were found between all materials. In the comparison of flexural strength according to thickness, flexural strength of 2.5 mm was significantly higher than that of 1.6 mm in C-LC. Flexural strength of 2.5 mm and 2.0 mm was significantly higher than that of 1.6 mm in P-DC and M-VP. In M-IV, as the thickness increases, significant increase in flexural strength appeared. SEM analysis illustrates different fracture surfaces of the specimens. Conclusion: The flexural strength of different CAD/CAM denture base resins used in this study varied according to the composition and properties of each material. The flexural strength of CAD/CAM denture base resins was higher than the standard suggested by ISO 20795-1:2013 at a thickness of 1.6 mm or more though the thickness decreased. However, for clinical use of dentures with lower thickness, further researches should be done regarding other properties at lower thickness of denture base resins.

Genetic Organization of an Inducible ${\beta}$-Lactamase Gene Isolated from Chromosomal DNA of Staphylococcus aureus (Staphylococcus aureus에서 분리된 유발성 ${\beta}$-Lactamase 유전자의 유전적 구성)

  • Kim, Young-Sun;Min, Kyung-Il;Byeon, Woo-Hyeon
    • Korean Journal of Microbiology
    • /
    • v.32 no.1
    • /
    • pp.20-27
    • /
    • 1994
  • An inducible ${\beta}$-lactamase gene (bla) was identified and isolated from the chromosomal DNA of multiple drug resistant strains of Staphylococcus aureus. Determined base sequence of bla and of its flanking region was compared with those of bla genes identified on the staphylococcal plasmids pPC1, pI258, pI1071, and pUB101. Base sequence of 843 base-long structural gene of our bla was same as that of pPCl-, pI258-, and pS1-bla. However, HindIII recognition site Which is found in most of the bla genes at 140 base upstream from the structural gene was moved to the site of 370 base upstream from the structural gene. And one of the two direct repeat sequence found in downstream flanking region of pI1071-bla was deleted in our bla. Amino acid sequence homology analysis of the ORF located around HindIII recognition site reveals that this 80 amino acids-long polypeptide is C-terminus of transposase of Tn4001.

  • PDF

Cloning and Base Sequence Determination of Replication Initiation Gene (rep) Isolated from Staphylococcus aureus DH1 R-plasmid pSBK203 (Staphylococcus aureus DH1에서 분리된 R-plasmid pSBK203의 복제 개시 유전자(rep) 분리 및 염기서열 결정)

  • Park, Seung-Moon;Kwon, Dong-Hyun;Byeon, Woo-Hyeon
    • Korean Journal of Microbiology
    • /
    • v.31 no.1
    • /
    • pp.44-47
    • /
    • 1993
  • A replication initiation gene was identified and its nucleotide sequence has been determined from a 3.8 kb, chloramphenicol acethyltransferase conferring R-plasmid pSBK203 of Staphylococcus aures. Location of the replication related region of pSBK 203 was determined by interuption with pUC 119 at XBaI and MspI sites which resulted in inactivation of replication in Bacilius subtilis. Base sequence of this region revealed on open reading frame of 942 base pairs, which encoded a 314 amino acid protein. Base sequence homology with other rep of pT181 family plasmids such as pT181, pC221, pC223, pS194, pU112, and pCW7 was ranged from 78% to 97% and the predicted amino acid sequence homology was from 72% to 95%.

  • PDF

Effect of chemical surface treatment on the flexural bond strength of heat curing denture base resin and reliners (화학적 표면처리가 열중합형 의치상 레진과 이장재간의 굴곡결합강도에 미치는 영향)

  • Choi, Esther;Han, Min-Soo;Kwon, Eun-Ja
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.219-227
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the effect of the chemical surface treatment on the flexural bond strength of heat curing denture base resin and reliners. Methods: Denture base resin surface was treated with MMA 95% and TEGDMA 5%, MMA 95% and silane coupling agent 5%, heat curing resin monomer. After denture reliners were injected, flexural bond strength was measured. Results: The repair resin of Vertex SC was higher than Lang, hard reliner of Kooliner was higher than Rebase. Soft reliner of Dura base and Coe-soft showed differently according to the surface treatment. The all chemical treatment groups on Vertex SC were significantly higher than control(p<0.05). In Lang group, 5% MPS treated group showed significantly higher flexural bond strength than others(p<0.05). In Kooliner group, all chemical treatment groups showed significantly higher than control(p<0.05). In Rebase group, the 5% MPS and the monomer denture base resin treated groups showed significantly higher than others(p<0.05). In Dura base group, 5% MPS treated group showed significantly higher flexural bond strength than others(p<0.05). In Coe-soft group, all treated groups were significantly higher than control group(p<0.05). Conclusion: TEGDMA, MPS, and the monomer of heat-cured denture base resin were effective to improve the bond strengths between denture base and denture relining materials. Especially, 5% MPS expected to strengthen effectively the bonding property of denture base and denture reliners within the results of this study.

The Effects of Cleansing oil on Skin by preferred Vegetable Base oil (선호하는 식물성 Base oil에 따른 클렌징 오일이 피부에 미치는 영향)

  • Kim, Jung-Eun;Lee, Jae-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.264-274
    • /
    • 2019
  • This study attempted to analyze the effects of cleansing oil on skin by preferred vegetable base oil. For this, a questionnaire survey was performed against 100 people, and their face washing habit and preferred vegetable base oils were examined. Based on the results, 4 different cleansing oils were prepared and experimented. The experiment was conducted against 10 adult women in their 20-30s, and moisture level, sebum level and trans-epidermal water loss (TEWL) before and after the experiment were measured. After the test, satisfaction was measured, and the results found the followings: When asked what cleansing oil is most preferred by vegetable base oil type, 'rose hip oil' was the highest, followed by 'olive oil', 'apricot kernel oil' and 'camellia oil'. According to the clinical trials, both moisture and sebum levels increased before and after cleansing in all four cleansing oil types by the preferred vegetable base oil (p<0.001, p<0.001). In addition, TEWL decreased with a difference by base oil (p<0.01). According to a subjective satisfaction survey which was performed after the experiment, rose hip oil-contained cleansing oil (RHC) was the highest in terms of cleansing effect and satisfaction level. Consequently, it was confirmed that the cleansing oil by vegetable base oil improved skin conditions by protecting a skin barrier with a positive effect on the improvement of sebum and moisture levels and TEWL. Even though a preferred oil type and a satisfaction level may differ by preferred oil and feeling after use, cleansing oil by vegetable base can be helpful as a skin care product which eases skin dryness and protects a skin barrier.

CONVERGENCE OF PREFILTER BASE ON THE FUZZY SET

  • Kim, Young-Key;Byun, Hee-Young
    • Korean Journal of Mathematics
    • /
    • v.10 no.1
    • /
    • pp.5-10
    • /
    • 2002
  • In this paper, we investigate the prefilter base on a fuzzy set and fuzzy net ${\varphi}$ on the fuzzy topological space (X,${\delta}$). And we show that the prefilter base $\mathcal{B}({\varphi})$ determines by the fuzzy net ${\varphi}$ converge to a fuzzy point $p$ iff the fuzzy net ${\varphi}$ converge to a fuzzy point $p$. Also we prove that if the prefilter base $\mathcal{B}$ converge to a fuzzy point $p$, then the $\mathcal{B}$ has the cluster point $p$.

  • PDF

A Study on the Breakdown Voltage Characteristics with Process and Design Parameters in Trench Gate IGBT (트렌치 게이트 IGBT 에서의 공정 및 설계 파라미터에 따른 항복 전압 특성에 관한 연구)

  • Shin, Ho-Hyun;Lee, Han-Sin;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.5
    • /
    • pp.403-409
    • /
    • 2007
  • In this paper, effects of the trench angle($\theta$) on the breakdown voltage according to the process parameters of p-base region and doping concentrations of n-drift region in a Trench Gate IGBT (TIGBT) device were analyzed by computer simulation. Processes parameters used by variables are diffusion temperature, implant dose of p-base region and doping concentration of n-drift region, and aspects of breakdown voltage change with change of each parameter were examined. As diffusion temperature of the p-base region increases, depth of the p-base region increases and effect of the diffusion temperature on the breakdown voltage is very low in the case of small trench angle($45\;^{\circ}$) but that is increases 134.8 % in the case of high trench angle($90\;^{\circ}$). Moreover, as implant dose of the p-base region increases, doping concentration of the p-base region increases and effect of the implant dose on the breakdown voltage is very low in the case of small trench angle($45\;^{\circ}$) but that is increases 232.1 % in the case of high trench angle($90\;^{\circ}$). These phenomenons is why electric field concentrated in the trench is distributed to the p-base region as the diffusion temperature and implant dose of the p-base increase. However, effect of the doping concentration variation in the n-drift region on the breakdown voltage varies just 9.3 % as trench angle increases from $45\;^{\circ}$ to $90\;^{\circ}$. This is why magnitude of electric field concentrated in the trench changes, but direction of that doesn't change. In this paper, respective reasons were analyzed through the electric field concentration analysis by computer simulation.