• Title/Summary/Keyword: P-Y curves

Search Result 993, Processing Time 0.028 seconds

Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

  • Creanga, Adriana Gabriela;Geha, Hassem;Sankar, Vidya;Teixeira, Fabricio B.;McMahan, Clyde Alex;Noujeim, Marcel
    • Imaging Science in Dentistry
    • /
    • v.45 no.3
    • /
    • pp.153-158
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Materials and Methods: Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. Results: A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. Conclusion: CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption.

LC-MS Determination and Bioavailability Study of Imidapril Hydrochloride after the Oral Administration of Imidapril Tablets in Human Volunteers

  • Yun Ji Hye;Myung Ja Hye;Kim Hye Jin;Lee Sibeum;Park Jong-Sei;Kim Won;Lee Eun-Hee;Moon Cheol Jin;Hwang Sung-Joo
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.463-468
    • /
    • 2005
  • The purpose of the present study was to develop a standard protocol for imidapril hydrochloride bioequivalence testing. For this reason, a specific LC-MS method was developed and validated for the determination of imidapril in human plasma. A solid-phase extraction cartridge, $Sep-pak^{R}$ C18, was used to extract imidapril and ramipril (an internal standard) from deproteinized plasma. The compounds were separated using a XTerra $MS^{R}$?C18 column ($3.5 {\mu}m, 2.1\times150 mm$) and $acetonitrile-0.1\%$ formic acid (67:33, v/v) adjusted to pH 2.4 by 2 mmol/L ammonium formic acid, as mobile phase at 0.3 mL/min. Imidapril was detected as m/z 406 at a retention time of ca. 2.3 min, and ramipril as m/z 417 at ca. 3.6 min. The described method showed acceptable specificity, linearity from 0.5 to 100 ng/mL, precision (expressed as a relative standard deviation of less than $15\%$), accuracy, and stability. The plasma concentration-versus-time curves of eight healthy male volunteers administered a single dose of imidapril (10 mg), gave an $AUC_{12hr}$ of imidapril of $121.48\pm35.81 ng mL^{-1} h$, and $C_{max} and T_{max}$ values of $32.59\pm9.76 ng/mL and 1.75\pm0.27 h$. The developed method should be useful for the determination of imidapril in plasma with sufficient sensitivity and specificity in bioequivalence study.

Effects of Radix Stemonae on the Airway Smooth Muscle (기관지(氣管支) 평활근(平滑筋)에 미치는 백부근(百部根)의 효과(效果))

  • Kim Sung-Kyu;Woo Won-Hong;Ryu Do-Gon;Han Jong-Hyun
    • Korean Journal of Acupuncture
    • /
    • v.17 no.1
    • /
    • pp.67-73
    • /
    • 2000
  • The purpose of the present study is to determine the effect of Radix Stemonae on histamine induced tracheal smooth muscle contraction in guinea pigs. Guinea pig(500g, male) were killed by $CO_2$ exposure and a segment (8-10mm) of the thoracic trachea from guinea pig was cut into equal segments and mounted 'in pairs' in a tissue bath. Contractile force was measured with force displacement transducers under 0.5g loading tension. The dose of histamine (His) which evoked 50% of maximal response ($ED_{50}$) was obtained from cumulative dose response curves for histamine ($10^{-7}∼10^{-4}M$). Contractions evoked by His ($ED_{50}$) were inhibited significantly by Radix Stemonae. In guinea pig tracheal smooth muscle, the mean percent inhibition of histamine induced contraction was 87.4% (p<0.01) after $100{\mu}l/ml$ Radix Stemonae. Following treatment with propranolol, the mean percent inhibition caused by $100{\mu}l/ml$ Radix Stemonae fell to 16.2% in guinea pig induced by histamine contraction. Indomethacin and methylene blue($10^{-7}M$) did not significantly alter the inhibitory effect of Radix Stemonae. These results indicate that Radix Stemonae can relax histamine induced contraction of guinea pig tracheal smooth muscle, and that this inhibition involves sympathetic effects.

  • PDF

The Precipitation Phenomena of Al-2.1Li-2.9Cu alloy by Differential Scanning Calorimetry(III) - Aging behaviors - (열분석법에 의한 Al-2.1Li-2.9Cu합금의 석출현상(II) - 시효거동 -)

  • Park, Tae-Won
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.10 no.1
    • /
    • pp.63-70
    • /
    • 1997
  • A study was performed to examine the aging behaviors of Al-2.1Li-2.9Cu alloy by differential scanning calorimetry and transmission electron microscopy. DSC measurements were conducted over the temperature range of $25{\sim}550^{\circ}C$ at a heating rate of $5^{\circ}C$/min. for the specimens aged at 130, 160, $190^{\circ}C$ and $220^{\circ}C$ for various times after solution treatment at $540^{\circ}C$ for 30 minutes. The peaks due to the formation of G.P.zone were not detected in the specimens aged at 130 and $160^{\circ}C$, but those at 190 and $220^{\circ}C$ appeared in DSC curves. The heat absorption due to the dissolution of ${\delta}^{\prime}$ phase was increased with increasing aging time at $130^{\circ}C$ aging. In contrast, those values for the specimens aged at 160 and $190^{\circ}C$ were initially increased and inversely decreased at the transition time of 72 and 1 hour, respectively. The heat evolution due to the formation of $T_1$ phase was nearly unchanged at $130^{\circ}C$ aging, but at $160^{\circ}C$ and $190^{\circ}C$ aging, drastically decreased after the transition time. It can be considered that the increase of $T_1$ phase results in the decrease of ${\delta}^{\prime}$ phase when aging time is longer than the transition time. The hardness of the specimen aged at $190^{\circ}C$ is initially higher compared with that at $160^{\circ}C$, however, the peak hardness shows the lower value than that at $160^{\circ}C$.

  • PDF

Effects of Improving Alcohol Metabolism of Yeast Extract Mixtures and Hovenia dulcis Mixtures in Healthy Men - A Double-Blind, Randomized Crossover, Placebo-Controlled Trial - (효모추출복합물과 헛개나무 열매추출 복합물이 알코올 대사에 미치는 영향 - 무작위, 이중맹검, 위약 대조군, 교차 인체적용시험 -)

  • Cho, Bo-Ram;Nam, Choong-Woo;Choung, Se-Young;Jeong, In-Kyung;Moon, Min-Sun
    • The Korean Journal of Food And Nutrition
    • /
    • v.30 no.4
    • /
    • pp.735-741
    • /
    • 2017
  • This study was conducted to investigate if the supplement formula may improve alcohol metabolism in healthy adult men. In a double-blinded, randomized, crossover study, subjects were administrated yeast extract mixtures (YEM, n=15), Hovenia dulcis mixtures (HDM, n=15), placebo (PLA, n=15), and control (CON, n=15) in an oral dose followed by one week washout periods. At each visit (0, 1, 2, 3, 4 week), subjects drank 450 mL, 20.1 percent alcohol after administered mixtures. Blood was drawn periodically (0, 0.25, 0.5, 1, 2, 4, 6, 15 hours). Fifteen subjects completed the protocol and were included in the analysis. Plasma ethanol concentration was lower in YEM (10 percent) and the HDM (5 percent) groups. The area under the curves (AUC) and $C_{max}$ for plasma ethanol were significantly decreased only in the YEM group, when compared with the CON group. The AUC and $C_{max}$ for plasma acetaldehyde concentration were significantly decreased in the YEM (45 and 54 percent) and the HDM (35 and 53 percent) groups respectively, when compared with PLA (p<0.01). Together, these findings validate that YEM or HDM improved alcohol metabolism and hangover syndromes, leading to reduce alcohol concentration and acetaldehyde concentration without adverse effects.

Modelling and packed bed column studies on adsorptive removal of phosphate from aqueous solutions by a mixture of ground burnt patties and red soil

  • Rout, Prangya R.;Dash, Rajesh R.;Bhunia, Puspendu
    • Advances in environmental research
    • /
    • v.3 no.3
    • /
    • pp.231-251
    • /
    • 2014
  • The present study examines the phosphate adsorption potential and behavior of mixture of Ground Burnt Patties (GBP), a solid waste generated from cooking fuel used in earthen stoves and Red Soil (RS), a natural substance in fixed bed column mode operation. The characterization of adsorbent was done by Proton Induced X-ray Emission (PIXE), and Proton Induced ${\gamma}$-ray Emission (PIGE) methods. The FTIR spectroscopy of spent adsorbent reveals the presence of absorbance peak at $1127cm^{-1}$ which appears due to P = O stretching, thus confirming phosphate adsorption. The effects of bed height (10, 15 and 20 cm), flow rate (2.5, 5 and 7.5 mL/min) and initial phosphate concentration (5 and 15 mg/L) on breakthrough curves were explored. Both the breakthrough and exhaustion time increased with increase in bed depth, decrease in flow rate and influent concentration. Thomas model, Yoon-Nelson model and Modified Dose Response model were used to fit the column adsorption data using nonlinear regression analysis while Bed Depth Service Time model followed linear regression analysis under different experimental condition to evaluate model parameters that are useful in scale up of the process. The values of correlation coefficient ($R^2$) and the Sum of Square Error (SSE) revealed the Modified Dose Response model as the best fitted model to the experimental data. The adsorbent mixture responded effectively to the desorption and reusability experiment. The results of this finding advocated that mixture of GBP and RS can be used as a low cost, highly efficient adsorbent for phosphate removal from aqueous solution.

Edge perturbation on electronic properties of boron nitride nanoribbons

  • K.L. Wong;K.W. Lai;M.W. Chuan;Y. Wong;A. Hamzah;S. Rusli;N.E. Alias;S. Mohamed Sultan;C.S. Lim;M.L.P. Tan
    • Advances in nano research
    • /
    • v.15 no.5
    • /
    • pp.385-399
    • /
    • 2023
  • Hexagonal boron nitride (h-BN), commonly referred to as Boron Nitride Nanoribbons (BNNRs), is an electrical insulator characterized by high thermal stability and a wide bandgap semiconductor property. This study delves into the electronic properties of two BNNR configurations: Armchair BNNRs (ABNNRs) and Zigzag BNNRs (ZBNNRs). Utilizing the nearest-neighbour tight-binding approach and numerical methods, the electronic properties of BNNRs were simulated. A simplifying assumption, the Hamiltonian matrix is used to compute the electronic properties by considering the self-interaction energy of a unit cell and the interaction energy between the unit cells. The edge perturbation is applied to the selected atoms of ABNNRs and ZBNNRs to simulate the electronic properties changes. This simulation work is done by generating a custom script using numerical computational methods in MATLAB software. When benchmarked against a reference study, our results aligned closely in terms of band structure and bandgap energy for ABNNRs. However, variations were observed in the peak values of the continuous curves for the local density of states. This discrepancy can be attributed to the use of numerical methods in our study, in contrast to the semi-analytical approach adopted in the reference work.

Inspiratory Flow Rate for the Evaluation of Bronchodilator in Patients with COPD (만성폐쇄성폐질환 환자에서 기관지확장제 흡입에 대한 흡기환기지표의 반응)

  • Baik, Jae-Joong;Park, Keon-Uk;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.342-350
    • /
    • 1995
  • Background: Although there are improvements of clinical symtoms after bronchodilator inhalation in COPD patients, it has been noted that there was no increase of $FEV_1$ in some cases. $FEV_1$ did not reflect precisely the improvement of ventilatory mechanics after bronchodilator inhalation in these COPD patients. The main pathophysiology of COPD is obstruction of airway in expiratory phase but in result, the load of respiratory system is increased in inspiratory phase. Therefore the improvement of clinical symptoms after bronchodilator inhalation may be due to the decrease of inspiratory load. So we performed the study which investigated the effect of bronchodilator on inspiratory response of vetilatory mechanics in COPD patients. Methods: In 17 stable COPD patients, inspiratory and expiratory forced flow-volume curves were measured respectively before bronchodilator inhalation. 10mg of salbutamol solution was inhaled via jet nebulizer for 4 minutes. Forced expiratory and inspiratory flow-volume curves were measured again 15 minutes after bronchodilator inhalation. Results: $FEV_1$, FVC and $FEV_1$/FVC% were $0.92{\pm}0.34L$($38.3{\pm}14.9%$ predicted), $2.5{\pm}0.81L$($71.1{\pm}21.0%$ predicted) and $43.1{\pm}14.5%$ respectively before bronchodilator inhalation. The values of increase of $FEV_1$, FVC and PIF(Peak Inspiratory Flow) were $0.15{\pm}0.13L$(relative increase: 17.0%), $0.58{\pm}0.38\;L$(29.0%) and $1.0{\pm}0.56L$/sec(37.5%) respectively after bronchodilator inhalation. The increase of PIF was twice more than $FEV_1$ in average(p<0.001). The increase of PIF in these patients whose $FEV_1$ was not increased after bronchodilator inhalation were 35.0%, 44.0% and 55.5% respectively. Conclusion: The inspiratory parameter reflected improvement of ventilatory mechanics by inhaled bronchodilater better than expiratory parameters in COPD patients.

  • PDF

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD (침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구)

  • Kay, Kee-Sung;Chung, Chae-Heon;Kang, Dong-Wan;Kim, Byeong-Ok;Hwang, Ho-Gil;Ko, Yeong-Mu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF