• Title/Summary/Keyword: P-Y curves

Search Result 993, Processing Time 0.034 seconds

Structural, Optical, and Electrical Characterization of p-type Graphene for Various AuCl3 Doping Concentrations (AuCl3를 도핑하여 제작한 p형 그래핀의 도핑농도에 따른 구조적, 광학적, 및 전기적 특성 연구)

  • Kim, Sung;Shin, Dong Hee;Choi, Suk-Ho
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.270-275
    • /
    • 2013
  • Single-layer graphene layers have been synthesized by using chemical vapor deposition, subsequently transferred on 300 nm $SiO_2/Si$ and quartz substrates, and doped with $AuCl_3$ by spin coating for various doping concentrations ($n_D$) from 1 to 10 mM. Based on the $n_D$-dependent variations of Raman frequencies/peak-intensity ratios, sheet resistance, work function, and Dirac point, measured by structural, optical, and electrical analysis techniques, the p-type nature of graphene is shown to be strengthened with increasing $n_D$. Especially, as estimated from the drain current-gate voltage curves of graphene field effect transistors, the hole mobility is very little varied with increasing $n_D$, in strong contrast with the $n_D$-dependent large variation of electron mobility. These results suggest that $AuCl_3$ is one of the best p-type dopants for graphene and is promising for device applications of the doped graphene.

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF

Microcomputer Based Vacuum Drying System and its Application to the Vacuum Drying of Green Red Pepper (마이크로컴퓨터 감압건조(減壓乾燥)시스템의 제작운영(製作運營)과 풋고추의 감압건조특성(減壓乾燥特性))

  • Chun, Jae-Kun;Kang, Jun-Soo
    • Applied Biological Chemistry
    • /
    • v.30 no.1
    • /
    • pp.65-70
    • /
    • 1987
  • In Girder to measure the pressure and weight decrease of drying sample during the vacuum drying process of food, sensing devices were designed and constructed with strain gauge. Microcomputer based vacuum drying system was made up of these devices interfaced to apple II microcomputer. The electrical output signal from vacuum sensor which constituted with Bourdon tube whereon strain gauge attached were digitalized and input to microcomputer through the MC 6821 interface I.C. chip. The relationship between read-out digital value (D) from microcomputer and readings of vacuum gauge (P, mmHg) was P=-146.136+3.620D'(r=0.9994) The pressure control of vacuum dryer was successfully conducted in the range of $400{\sim}600\;mmHg$ accuracy. The digitalized load cell output (D) could be correlated with the real weight (W, g) as W=-14,000+0.585D (r=0.9998) Drying curves of green red pepper under $64^{\circ}C$, $400{\sim}600\;mmHg$ was similar to those of red pepper and differently affected by the degree of vacuum pressure but was varied according to their shape (cut or whole). Moisture movement of green red pepper during the vacuum drying process was fitted to Page model. The empirical equations obtained were $M-M_e/M_o-M_e={\exp}\;(-0.0673{\theta}^{1.177})$ and $M-M_e/M_o-M_e={\exp}\;(-0.0655\;{\theta}^{1.477})$ for whole and cut green red pepper, respectively.

  • PDF

Changes in Textural Properties of Korean Radish and relevant Chemical, Enzymatic Activities during Salting (염장과정 중 무의 조직감과 이와 관련된 화학적, 효소활성 변화)

  • Rhee, Hee-Seoup;Lee, Gui-Ju
    • Journal of the Korean Society of Food Culture
    • /
    • v.8 no.3
    • /
    • pp.267-274
    • /
    • 1993
  • This study was aimed to investigate the changes in textural properties of Korean radish and relevant chemical, enzymatic activities during salting. During salting, pH was decreased and total acidity was increased. The maximum compression and puncture forces of Korean radish were decreased significantly whereas cutting force was increased. From the force-distance curves, the break point and maximum force point disappeared in salted Korean radish whereas these appeared apparently in fresh one. Also, the number of peak obtained by three types of test from salted Korean radish was decreased. Hot water soluble pectin and 0.4% Na-hexametaphosphate soluble pectin were increased whereas 0.05 N-HCl soluble pectin were decreased significantly. Polygalacturonase activity were increased in Korean radish solid(RS) and Korean radish juice(RJ) until 4 days of salting. Pectin esterase activity were decreased in RS and RJ. Cx-cellulase activity did not appear initially, however, they began to show their activities after 2 days of salting and were increased in RJ although it was low.

  • PDF

Actual Uses and Water Qualities of Irrigation Water from Agricultural Reservoir and Pumping Station (관개용 저수지 및 양수장의 농업용수 공급량 및 수질)

  • Choi, Jin-Kyu;Han, Kang-Wan;Koo, Ja-Woong;Son, Jae-Gwon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.3
    • /
    • pp.205-212
    • /
    • 2001
  • Joongpyong reservoir and Guiseok pumping station were selected as the hydrologic monitoring sites for the water level gauging and amount of irrigation water use, and water samples were taken and analysed periodically. Rating curves were derived from the relations water level and discharge data, and water supply through culvert of the Joongpyong reservoir was $593,200m^3$ and irrigation water $2,913,000m^3$ from the Guiseok pumping station. Changes of stream water qualities such as water temperature, pH, EC, total nitrogen, total phosphorus were examined, pH was 6.98.1 lower than the criteria of agricultural water 6.0~8.5, total nitrogen $0.9{\sim}4.5mg\;L^{-1}$, total phosphorus $0.008{\sim}0.036mg\;L^{-1}$. The results from this study could be offered as a basic data for the irrigation plan and water quality management.

  • PDF

Threshold Voltage Variation of ZnS:Mn/ZnS:Tb Thin- film Electroluminescent(TFEL) Devices (ZnS:Mn/ZnS:Tb 박막 전계발광소자의 문턱전압 변화)

  • 이순석;윤선진;임성규
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.21-27
    • /
    • 1998
  • Electrical and optical characteristics of ZnS:Mn/ZnS:Tb multilayer TFEL devices were investigated for multi-color electroluminescent display applications. Emission spectra of M $n^{2+}$ and T $b^{3+}$ ions were observed from ZnS:Mn/ZnS:Tb multi-layer TFEL devices, and were very broad from 540 nm to 640 nm. Saturation luminance measured at 155 V was 1025 Cd/$m^2$. C-V, $Q_{t}$ - $V_{p}$ curves showed that the phosphor capacitance ( $C_{p}$ ) and the insulator capacitance ( $C_{i}$ ) were 13.5nF/$\textrm{cm}^2$ and 60 nF/$\textrm{cm}^2$, respectively. Threshold voltage( $V_{thl}$) was shown to decrease from 126 V to 93 V due to the increase of the applied voltage from 155 V to 185 V, which was attributed to the increase of the polarization charge. The equation for the calculation of the threshold voltage as a function of the applied voltage was proposed for the first time. The calculated threshold voltage agreed well with the data obtained from the measurement.t.t.t.

  • PDF

Simultaneous Determination of Tetracycline Antibiotics by 3-Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME) and HPLC-UV/Vis (3-상 속빈 섬유-액체상 미량추출법(HF-LPME)과 HPLC-UV/Vis을 이용한 Tetracycline류 항생제 동시분석)

  • Oh, Woong Kyo;Myung, Seung-Woon
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.6
    • /
    • pp.535-542
    • /
    • 2014
  • A simple and efficient preconcentration method was developed using three-phase liquid phase microextraction prior to HPLC-UV for simultaneous extraction and determination of tetracycline antibiotics (tetracycline, oxytetracycline, and chlortetracycline). The tetracycline antibiotics were separated simultaneously on a column ($C_8$, $3.0{\times}150mm$, $3{\mu}m$) with high selectivity and sensitivity using gradient elution. Under optimized conditions (extraction solvent, heptanal; pH of donor, 9.0; pH of acceptor, 1.0; stirring speed, 700 rpm; NaCl salt, 0%; and extraction time, 60 min), enrichment factors (EF) were between 5.6 and 22.3. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of $0.08{\sim}0.8{\mu}g/mL$ and $0.4{\sim}1.6{\mu}g/mL$, respectively. The calibration curves were linear within the range of $0.1{\sim}32{\mu}g/mL$ with the square of the correlation coefficient being more than 0.995. The precision (as a relative standard deviation, RSD) and accuracy (as a relative recovery) within working range were 1.3~9.1% and 84~118%, respectively.

Response of Photobacterium phosphoreum to Heavy Metal (Photobacterium phosphoreum의 중금속에 대한 반응성)

  • 정계훈;김현숙;이은수;정성제;이정건;김은기;전억한
    • KSBB Journal
    • /
    • v.14 no.3
    • /
    • pp.342-350
    • /
    • 1999
  • Photobacterium phosphoreum was used in order to study response to heavy metal including $HgCl_2$, $CdCl_2$, $MnSO_4$ and $ZnSO_4$ in view of developing monitoring system for toxic substances. The concentrations of heavy metal causing 50% reduction($EC_{50}$) in bioluminescence intensity were determined with both free and immobilized P. phosphoreum. The bioluminescence responses were examined at various concentrations of heavy metal after 10, 20 and 30 min of exposure. The linear correlation between Gamma values and concentrations of heavy metal was obtained and $EC_{50}$ was calculated from the linear correlation. The significant inhibitory concentrations for bioluminescence emission were found to be 0.05mg/L for $HgCl_2$, 25mg/L for $CdCl_2$, 50mg/L for $MnSO_4$ and 12.5mg/L for $ZnSO_4$, respectively. The free cell and disc type were shown to be more sensitive to heavy metal than cells mixed with Na-alginate or immobilized on Sr-alginate. However, the linear regression curves were derived from the Sr-alginate immobilized cells indicating the immobilization method is a useful tool for monitoring of heavy metal under more stable condition of bioluminescence.

  • PDF

Prognostic Significance of 14-3-3γ Overexpression in Advanced Non-Small Cell Lung Cancer

  • Raungrut, Pritsana;Wongkotsila, Anusara;Lirdprapamongkol, Kriengsak;Svasti, Jisnuson;Geater, Sarayut Lucien;Phukaoloun, Monlika;Suwiwat, Supaporn;Thongsuksai, Paramee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3513-3518
    • /
    • 2014
  • The 14-3-3 protein has been shown to be involved in the cancer process. However, there is no understanding of the relationship between 14-3-$3{\gamma}$ (14-3-3 gamma) expression and prognosis in advanced non-small cell lung cancer. In this study, we therefore investigated the association between protein levels by immunohistochemistry and clinicopathological features of advanced NSCLC patients. Survival curves were estimated using the Kaplan-Meier method and tested by log-rank. Multivariate analysis was conducted with the Cox's regression model to determine independence of factors. p values less than 0.05 were considered significant. A total 153 patients were studied, with 54.3% being stage III and 45.8% stage IV. Fifty-one cases (33.3%) were squamous cell carcinomas, and 98 cases (64.1%) were adenocarcinomas. High 14-3-$3{\gamma}$ expression was seen in 59.5% and significantly correlated with lymph node metastasis (p=0.010) and distant metastasis (p=0.017). On Kaplan-Meier analysis, high 14-3-$3{\gamma}$ expression was associated with poorer survival with a marginal trend toward significance (p=0.055). On multivariate analysis, age, treatment, and 14-3-$3{\gamma}$ expression proved to be independent prognostic parameters. In vitro experiments indicated that 14-3-$3{\gamma}$ overexpression also played a potential role in cancer invasion. In conclusion, our data suggest that 14-3-$3{\gamma}$ overexpression is associated with invasion and a poor prognosis. Therefore, 14-3-$3{\gamma}$ may be a potential prognostic marker of advanced non-small cell lung cancer.

An Experimental Investigation of the Variations of the Elastic Wave Velocities with Compaction Energy for Railway Roadbed Materials (다짐 에너지를 고려한 노반 성토 재료의 탄성파 속도 변화의 실험적 분석)

  • Kim, Hak-Sung;Jung, Young-Hoon;Mok, Young-Jin;Lee, Jin-Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1037-1047
    • /
    • 2013
  • A systematic laboratory compaction testing was performed with the laboratory seismic measurements of the compacted specimens sampled from various compaction fills and was supplemented with in-situ seismic testing to investigate the effects of compaction energy on the elastic wave velocities of the railway roadbed materials. The both variances of the compressive and shear wave velocities with moisture content curve ($V_p$-w and $V_s$-w curves) are similar to the general trend of the density-moisture content curve(${\gamma}_d$-w curve). At the wet side of optimal moisture content (OMC), either $V_p$ or $V_s$ does not significantly increase, which is well reflecting the no gaining in density with the increasing compaction energy exceeding modified-D compaction effort. $V_p$ increases linearly with ${\gamma}_d$ at the dry side of OMC, while it does exponentially at the wet side. The in-situ wave velocities were found to be influenced by the level of confinement and $V_s$ was more sensitive to compaction energy than $V_p$.