• Title/Summary/Keyword: P-P bonding

Search Result 887, Processing Time 0.027 seconds

THE EFFECT OF CYANATE METHACRYLATE ON THE SHEAR BOND STRENGTHS TO DENTIN (Cyanate methacrylate가 상아질 결합강도에 미치는 영향)

  • Kim, Hyang-Kyung;Choi, Kyung-Kyu;Choi, Gi-Woon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.236-247
    • /
    • 2007
  • The purpose of this study was to evaluate the effects of cyanate methacylate on the shear bond strengths to bovine dentin surfaces as a dentin primers. Seven experimental adhesives were made with different mass fraction of Isocyanatoetylme-thacrylate (IEM), 40wt% HEMA (Wako Pure Chemical Industries Osaka, Japan), 0.6% camphoroquinone, 0.4% amine and ethanol as balance dentin bonding agents (0, 2, 4, 6, 8, 10, 12%) were made and applied on the surface of bovine dentin specimens of 7 experimental groups. Shear bond strengths were measured using a universal testing machine (Instro 4466). To identify the ratio and modes of cohesive failures, microscopic examinationn was performed. The ultra-structure of resin tags were observed under scanning electron microscope. The results were as follows ; 1) A higher shear bond strengths (33.62 MPa) in group 8% of Cyanate methacrylate to dentin were found, but there were no statistically significancy between Groups (p > 0.05). 2) The higher ratio of cohesive failures mode in group 2, 6, an 10% could be seen than that in any other groups. 3) A shorter resin tags were observed in all experimental groups. This could be resulted that the preventing from the cyanate methacrylate penetrate into dentin owing to reacting it with dentin collagen. Therefore the resin tags were shorter in lengths. Whether the higher bonding strengths of dentin bonding agents can be affected was not been assured with statistic results. The results indicated that the relation between tensile strengths of the dentin adhesives to bovine dentin and resin tags formed into the dentin could not affected. The main reason of increasing the shear bond strength to bovine dentin in experimental groups could not be assured.

A STUDY ON THE SHEAR BOND STRENGTH AND SCANNING ELECTRON MICROSCOPIC INVESTIGATION OF DENTIN BONDING AGENTS (상아질 접착제의 전단결합강도 및 주사전자현미경적 연구)

  • Lee, Gi-Hwan;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.289-302
    • /
    • 1995
  • The purpose of this study was to estimate the shear bond strength and observe the fractured and interfacial surfaces of various dentin bonding agents used conjunction with a visible light cured composite. The senentytwo human premolars and molars extracted due to periodontal or orthodontic reasons were used and randomely divided into six groups. All the prepared dentin surfaces were treated with Superbond D-liner, Scotchbond Multi-Purpose, All-Bond 2 and Prisma Universal Bond 3 accroding to the manufacturer's instructions. Six specimens were then demineralized in 10 % HCl for 24 hours and the other six specimens were not demineralized in order to observe the interfacial surfaces with Hitachi X-450 SEM at 25Kv. Also shear bond strength were obtained using an Instron Testing Machine with a crosshead speed of 1mm/min. The following results were obtained : 1. Although shear bond strength of Superbond D-Liner(17.35 MPa) and Scotch-bond Multi-Purpose group(17.29 MPa) were higher than the All-Bond 2(12.80 MPa) and Prisma Universial Bond 3 (13.43 MPa), there were no significant statistic differences in the shear bond strength between 4 groups.(P<0.05) As a result of etching to dentin in Prism a Universial BOND 3 experimentally, the resin tag was formed, but shear bond strength was decreased. 2. The resin tag into the opened dentinal tubule was formed in Superbond D-Liner, Scotchbond Multi-Purpose, All-Bond 2(etching) and Prisma Universial Bond 3(etching), but not in the All-Bone 2 and Prism a Universial Bond 3(non-etching). 3. Strong, durable bonds between dentin and dentinal bonding agents are essential, not only resin tag into the dentinal tubules, but also hybrid layer.

  • PDF

Effect of adhesive primers on bonding strength of heat cure denture base resin to cast titanium and cobalt-chromium alloy

  • Kim, Su-Sung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.41-46
    • /
    • 2009
  • STATEMENT OF PROBLEM. The poor chemical bonding of a denture base resin to cast titanium framework often introduces adhesive failure and increases microleakage. PURPOSE. This study evaluated the shear bond strengths of a heat cure denture base resin to commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy using two adhesive primers. MATERIAL AND MATHODS. Disks of commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy were cast. Specimens without the primer were also prepared and used as the controls. The shear bond strengths were measured on a screw-driven universal testing machine. RESULTS. The primers significantly(P < .05) improved the shear bond strengths of the heat cure resin to all metals. However, the specimens primed with the Alloy $primer^{(R)}$(MDP monomer) showed higher bond strength than those primed with the MR $bond^{(R)}$(MAC-10 monomer) on titanium. Only adhesive failure was observed at the metal-resin interface in the non-primed specimens, while the primed specimens showed mixed failure of adhesive and cohesive failure. CONCLUSIONS. The use of appropriate adhesive metal primers makes it possible not only to eliminate the need for surface preparation of the metal framework before applying the heat cure resins, but also reduce the need for retentive devices on the metal substructure. In particular, the Alloy $primer^{(R)}$, which contains the phosphoric acid monomer, MDP, might be clinically more acceptable for bonding a heat cure resin to titanium than a MR $bond^{(R)}$, which contains the carboxylic acid monomer, MAC-10.

Orthodontic bracket bonding to glazed full-contour zirconia

  • Kwak, Ji-Young;Jung, Hyo-Kyung;Choi, Il-Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Objectives: This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods: Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at $37^{\circ}C$, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results: Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z ($4.60{\pm}1.08MPa$) and all other groups ($13.38{\pm}2.57-15.78{\pm}2.39MPa$, p < 0.05). For AA-Z, most of the adhesive remained on the bracket. Conclusions: For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

A COMPARISON OF FRACTURE STRENGTHS OF PORCELAIN-FUSED-TO-TITANIUM CROWN AMONG TITANIUM SURFACE COATING TREATMENTS (타이타늄 표면 코팅 처리에 따른 타이타늄도재관의 파절강도 비교)

  • Kim, Ji-Hye;Park, Sang-Won;Vang, Mong-Sook;Yang, Hong-So;Park, Ha-Ok;Lim, Hyun-Pil;Oh, Gye-Jeong;Kim, Hyun-Seung;Lee, Kwang-Min;Lee, Kyung-Ku
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.203-215
    • /
    • 2007
  • Statement of problem: Titanium and its alloy, with their excellent bio-compatibility and above average resistance to corrosion, have been widely used in the field of dentistry. However, the excessive oxidization of titanium which occurs during the process of firing on porcelain makes the bonding of titanium and porcelain more difficult than that of the conventional metal-porcelain bonding. To solve this problem related to titanium-porcelain bonding, several methods which modify the surfaces, coat the surfaces of titanium with various pure metals and ceramics, to enable the porcelain adhesive by limiting the diffusion of oxygen and forming the adhesive oxides surfaces, have been investigated. Purpose: The purpose of this study was to know whether the titanium-porcelain bonding strength could be enhanced by treating the titanium surface with gold and TiN followed by fabrication of clinically applicable porcelain-fused-to-titanium crown Material and method: The porcelain-fused-to-titanium crown was fabricated after sandblasting the surface of the casting titanium coping with $Al_2O_3$ and treating the surface with gold and TiN coating followed by condensation and firing of ultra-low fusing porcelain. To compare with porcelain-fused-to-titanium crowns, porcelain-fused-to-gold crowns were fabricated and used as control groups. The bonding strengths of porcelain-fused-to-gold crowns and porcelain-fused-totitanium crowns were set for comparison when the porcelain was fractured on purpose to get the experimental value of fracture strength. Then, the surface were examined by SEM and each fracturing pattern were compared with each other Result:Those results are as follows. 1. The highest value of fracture strength of porcelain-fused-to-titanium crowns was in the order of group with gold coating, group with TiN coating, group with $Al_2O_3$ sandblasting. No statistically significant difference was found among the three (P>.05). 2. The porcelain-fused-to-gold crowns showed the highest value in bonding strength. The bonding strength of crowns porcelain-fused-to-titanium crowns of rest groups showed bonding strength reaching only 85%-94% of that of PFG, though simple comparision seemed unacceptable due to the difference in materials used. 3. The fracturing patterns between metal and porcelain showed mixed type of failure behavior including cohesive failure and adhesive failure as a similar patterns by examination with the naked eye and SEM. But porcelain-fused-to-gold crowns showed high incidence of adhesive failure and porcelain-fused-to-titanium crowns showed high incidence of cohesive failure. Conclusion: Above results proved that when fabricating porcelain-fused-to-titanium crowns, treating casting titanium surface with gold or TiN was able to enhance the bonding strength between titanium and porcelain. Mean value of masticatory force was found to showed clinically acceptable values in porcelain bonding strength in all three groups. However, more experimental studies and evaluations should be done in order to get better porcelain bonding strength and various surface coating methods that can be applied on titanium surface with ease.

Business Relationships and Structural Bonding: A Study of American Metal Industry (산업재 거래관계와 구조적 결합: 미국 금속산업의 분석 연구)

  • Han, Sang-Lin;Kim, Yun-Tae;Oh, Chang-Yeob;Chung, Jae-Moon
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.3
    • /
    • pp.115-132
    • /
    • 2008
  • Metal industry is one of the most representative heavy industries and the median sales volume of steel and nonferrous metal companies is over one billion dollars in the case America [Forbes 2006]. As seen in the recent business market situation, an increasing number of industrial manufacturers and suppliers are moving from adversarial to cooperative exchange attitudes that support the long-term relationships with their customers. This article presents the results of an empirical study of the antecedent factors of business relationships in metal industry of the United States. Commitment has been reviewed as a significant and critical variable in research on inter-organizational relationships (Hong et al. 2007, Kim et al. 2007). The future stability of any buyer-seller relationship depends upon the commitment made by the interactants to their relationship. Commitment, according to Dwyer et al. [1987], refers to "an implicit or explicit pledge of relational continuity between exchange partners" and they consider commitment to be the most advanced phase of buyer-seller exchange relationship. Bonds are made because the members need their partners in order to do something and this integration on a task basis can be either symbiotic or cooperative (Svensson 2008). To the extent that members seek the same or mutually supporting ends, there will be strong bonds among them. In other words, the principle that affects the strength of bonds is 'economy of decision making' [Turner 1970]. These bonds provide an important idea to study the causes of business long-term relationships in a sense that organizations can be mutually bonded by a common interest in the economic matters. Recently, the framework of structural bonding has been used to study the buyer-seller relationships in industrial marketing [Han and Sung 2008, Williams et al. 1998, Wilson 1995] in that this structural bonding is a crucial part of the theoretical justification for distinguishing discrete transactions from ongoing long-term relationships. The major antecedent factors of buyer commitment such as technology, CLalt, transaction-specific assets, and importance were identified and explored from the perspective of structural bonding. Research hypotheses were developed and tested by using survey data from the middle managers in the metal industry. H1: Level of technology of the relationship partner is positively related to the level of structural bonding between the buyer and the seller. H2: Comparison level of alternatives is negatively related to the level of structural bonding between the buyer and the seller. H3: Amount of the transaction-specific assets is positively related to the level of structural bonding between the buyer and the seller. H4: Importance of the relationship partner is positively related to the level of structural bonding between the buyer and the seller. H5: Level of structural bonding is positively related to the level of commitment to the relationship. To examine the major antecedent factors of industrial buyer's structural bonding and long-term relationship, questionnaire was prepared, mailed out to the sample of 400 purchasing managers of the US metal industry (SIC codes 33 and 34). After a follow-up request, 139 informants returnedthe questionnaires, resulting in a response rate of 35 percent. 134 responses were used in the final analysis after dropping 5 incomplete questionnaires. All measures were analyzed for reliability and validity following the guidelines offered by Churchill [1979] and Anderson and Gerbing [1988]., the results of fitting the model to the data indicated that the hypothesized model provides a good fit to the data. Goodness-of-fit index (GFI = 0.94) and other indices ( chi-square = 78.02 with p-value = 0.13, Adjusted GFI = 0.90, Normed Fit Index = 0.92) indicated that a major proportion of variances and covariances in the data was accounted for by the model as a whole, and all the parameter estimates showed statistical significance as evidenced by large t-values. All the factor loadings were significantly different from zero. On these grounds we judged the hypothesized model to be a reasonable representation of the data. The results from the present study suggest several implications for buyer-seller relationships. Theoretically, we attempted to conceptualize the antecedent factors of buyer-seller long-term relationships from the perspective of structural bondingin metal industry. The four underlying determinants (i.e. technology, CLalt, transaction-specific assets, and importance) of structural bonding are very critical variables of buyer-seller long-term business relationships. Our model of structural bonding makes an attempt to systematically examine the relationship between the antecedent factors of structural bonding and long-term commitment. Managerially, this research provides industrial purchasing managers with a good framework to assess the interaction processes with their partners and, ability to position their business relationships from the perspective of structural bonding. In other words, based on those underlying variables, industrial purchasing managers can determine the strength of the company's relationships with the key suppliers and its state of preparation to be a successful partner with those suppliers. Both the supplying and customer companies can also benefit by using the concept of 'structural bonding' and evaluating their relationships with key business partners from the structural point of view. In general, the results indicate that structural bonding gives a critical impact on the level of relationship commitment. Managerial implications and limitations of the study are also discussed.

  • PDF

EFFECT OF CAVITY DISINFECTANT ON THE BOND STRENGTH AND MICROLEAKAGE OF DENTIN BONDING AGENTS (와동 세척제가 상아질 결합제의 결합에 미치는 영향)

  • Song, Seung-Ho;Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.595-603
    • /
    • 2005
  • Incomplete removal of bacteria contaminated dentin or enamel associated with caries is a potential problem in restorative dentistry Secondary or residual caries, pulpal inflammation and hypersensitivity may result from bacteria left after the initial preparation, especially if an adequate seal against microleakage is not obtained. A possible solution to eliminate residual bacteria left in a cavity preparation would be to treat the cavity with cavity disinfectant wash. But a potential problem with using a cavity disinfectant with dentin bonding agents could be their interference with the ability of the resin to bond to the tooth micromechanically. The purpose of this study was to evaluate the effect of 2% chlorhexidine containing cavity disinfectant ($Consepsis^{(R)}$) on shear bond strength and microleakage of dentin bonding agents, $Adper ^{TM}$ $Scotchbond^{TM}$ Multi-Purpose, $Adper^{TM}$ Single Bond and $Adper^{TM}\;Prompt^{TM}\; L-Pop^{TM}$ Sixty and sixty sound human third molar teeth, respectively, were used for shear bond strength and microleakage test. For experimental group, cavity disinfectant was applied before dentin bonding agents, and was not applied for the control group. The result from the this study can be summarized as follows ; 1. Use of 2% chlorhexidine containing cavity disinfectant($Consepsis^{(R)}$) does not significantly affect the shear bond strength of dentin bonding agents. 2. Use of 2% chlorhexidine containing cavity disinfectant($Consepsis^{(R)}$) does not significantly affect the microleakage of dentin bonding agents.

  • PDF

Tensile Bond Strength of Glass Ionomer Cements (글라스 아이오노대 시멘트의 인장접착강도)

  • BYUN, Seung Min;KWON, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.317-324
    • /
    • 1996
  • This study was conducted to evaluate the tensile bond strength of three commercially available glass ionomer cements as orthodontic bracket adhesives. 120 premolars extracted for orthodontic treatment were prepared for bonding and standard edgewise brackets were bonded with Shofu Glaslonomer Cement (Shofu Co., U.S.A.), GC Fuji ItGC Co., Japan), KETAC-CEM(ESPE Co., West Germany) with different P/L ratio. The tensile bond strength was tested by Instron testing device after 24hours and 3months from bonding. After debracketing, bracket bases were examined to determine the failure sites. The results of this study were as follows: 1. KETAC CEM showed the highest bond strength other than measurement after 24 hours and at its original P/L ratio, and seemed to have clinically a proper bond strength. It seemed, however, that both Shofu Giaslonomer Cement and GC Fuji I had an inappropriate bond strength. 2. The incorporation of additional powder into the mixture improved the tensile bond strength. 3. Prolonged storage time improved the tensile bond strength. 4. Of the failure, failure occured at the tooth-adhesive interface(54.2%) was the most common type. The second type of failure(36.7%) was combination type, where part of the adhesive remained on the tooth and part on the bracket. And the last type of failure(9.1%) occured at the adhesive-bracket interface.

  • PDF

COMPARISON OF SHEAR BOND STRENGTH AND MARGINAL LEAKAGE OF RESIN MODIFIED GLASS IONOMER CEMENTS (강화형 글라스 아이오노머 합착용 시멘트의 접합강도 및 변연누출에 대한 연구)

  • Park, Hye-Yang;Oh, Nam-Sik;Lee, Keun-Woo;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.647-661
    • /
    • 1997
  • The resin modified glass ionomer cements(RMGICs) have been used for years since 1989. Recently it has been developed for luting of fixed restorations. To evaluate the bond strength and marginal leakage of RMGICs for luting usage, the 80 extracted human molars which had uniform area of exposed dentin were cemented with 3 types of RMGICs(Fuji Duet, Advance, Vitremer), a conventional Glass Ionomer Cement(GIC-Fuji I), and a resin cement (Panavia 21) to base metal alloy(Ni-Cr-Be). After thermocycling the specimens were immersed in basic fuschin dye for measuring marginal leakage. The shear bond strength was measured with Instron and the maximum dye penetration was measured to 0.1mm. The types of fractured patterns were determined with stereoscope(${\times}7.5$). The results are as follows. 1. The difference between 3 RMGICs and a conventional GIC in shear bond strength was not statistically significant. It seemed that RMGICs had lower shear bond strength than resin cement. (p<0.01) 2. The mean scores of marginal leakage had no significant difference between the resin cement and 3 RMGICs but it was much higher in conventional GIC than the RMGICs (p<0.05) 3. It was determined that the manufacturer and the methods of dentin pretreatment determined the pattern of fracture surfaces and the frequency of adhesive failure between teeth and 3 RMGICs standed as in following order - Vitremer, Advance, Fuji Duet. (p<0. 01) When the fracture pattern was analyzed, it could be said that the materials and the method of dentin pretreatment have much effect on bonding states. This means that the dentin bonding agents should be improved. But the limited products in this experiment can not evaluate the physical properties of the entire RMGICs. Therefore a further study which can evaluate various RMGICs should be in progress to develope better cements.

  • PDF

Soft x-ray Synchrotron Radiation Spectroscopy Study of Molecule-based Nano Bioparticles Containing Fe (철원소를 함유한 분자기반 생체물질 나노입자들의 연 x선 방사광 분광 연구)

  • Lee, Eun-Sook;Kim, D.H.;Hwang, Ji-Hoon;Lee, Ki-Ho;Kang, J.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.125-129
    • /
    • 2012
  • By employing soft x-ray absorption spectroscopy (XAS) and soft x-ray magnetic circular dichroism (XMCD), the electronic structures of molecule-based nano bioparticles, such as Helicobacter pylori ferritin (H. pylori ferritin), Heme, $NaM[Fe(CN)_6]{\cdot}H_2O$-type Prussian Blue (M=Co, Ni) analogue, have been investigated. The measured Fe 2p XAS spectra reveal that Fe ions are trivalent ($Fe^{3+}$) in H. pylori ferritins, while they are in the $Fe^{2+}-Fe^{3+}$ mixed-valent states in $NaM[Fe(CN)_6]{\cdot}H_2O$ Prussian Blue analogues (M=Co, Ni). According to the Fe 2p XMCD spectrum of high-state H. pylori ferritin, all the $Fe^{3+}$ ions have the same local symmetry and their magnetic moments are aligned in the same direction. It is also found that the Fe 3d orbitals in $NaM[Fe(CN)_6]{\cdot}H_2O$ have a strong covalent bonding to $(CN)^-$ ligands, but with a very weak bonding to the 2p orbitals of O ligands.