• Title/Summary/Keyword: P-I 선도

Search Result 403, Processing Time 0.036 seconds

UV LINE EMISSIONS OF 44i BOOTIS (44i BOO의 자외선 방출연구)

  • 한동주;김용기;한원용;이우백
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.335-340
    • /
    • 1998
  • We obtained UV light curves of 44i Bootis, a W UMa type star from the IUE low dispersion spectra. In order to investigate variations of the emission lines from chromospheric activity and transition region, UV line intensity has been measured for CI, CII, ClV, SiIV, HeII lines. Through plotting the line intensity with the orbital phase, we found that emission lines showed maximum at $0^p.2;and;0^p.8$ of the light curves, indicating the chromospheric activity of contact binary, 44i Bootis. We found that the light curves of UV emission lines is strongly modulated by the variation of chromospheric activities of 44i Bootis.

  • PDF

Numerical Model to Evaluate Resistance against Direct Shear Failure and Bending Failure of Reinforced Concrete Members Subjected to Blast Loading (폭발하중을 받는 철근콘크리트 부재의 직접전단 파괴 및 휨 파괴 저항성능 평가를 위한 수치해석 모델 개발)

  • Ju, Seok Jun;Kwak, Hyo-Gyoung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.6
    • /
    • pp.393-401
    • /
    • 2021
  • In this paper, we proposed a numerical model based on moment-curvature, to evaluate the resistance of reinforced concrete (RC) members subjected to blast loading. To consider the direct shear failure mode, we introduced a dimensionless spring element based on the empirical direct shear stress-slip relation. Based on the dynamic increase factor equations for materials, new dynamic increase factor equations were constructed in terms of the curvature rate for the section which could be directly applied to the moment-curvature relation. Additionally, equivalent bending stiffness was introduced in the plastic hinge region to consider the effect of bond-slip. To verify the validity of the proposed model, a comparative study was conducted against the experimental results, and the superiority of this numerical model was confirmed through comparison with the analytical results of the single-degree of freedom model. Pressure-impulse (P-I) diagrams were produced to evaluate the resistance of members against bending failure and direct shear failure, and additional parametric studies were conducted.

X-Ray Fluorescence Analysis of Iron and Titanium in Iron Ores by Dilution Parameter Method (희석 파라미터법에 의한 철광석 중 철과 티탄의 X-선 형광분석)

  • Young Sang Kim;Lee Chong Wook
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.3
    • /
    • pp.183-189
    • /
    • 1981
  • Iron and titanium, the major constituents in iron ores, were X-ray spectrometrically determined by using the dilution parameter method. A standard and samples possessing a similar composition were diluted with the diluent $ZrO_2$ to their proper respective ratios. After measuring the intensity of the fluorescent X-ray, the dilution parameter was calculated from the following equation. $Pa=\frac{\frac{I_{as}}{(I_{as})_d}}{D-1}{^{-1}}$The dilution parameters were used to correct the difference between the matrix effect of the standard and that of the sample. The content of the major constituents was calculated, without using any standard calibration curves, from the following equation;$W_a=W_a^*{\cdot}{\frac{I_as}{I_{as}^*}{\cdot}\frac{P_a^*}{P_a}$where asterisks indicate the standard. The results agreed with those of the wet analysis within 2% of relative error, and the precision of the experiment was also tolerably good.

  • PDF

The comparison of the fatigue crack initiation life in a notch (노치부의 피로균열발생 수명 비교)

  • Kim, S.H.;Bae, S.I.;Ham, K.C.;Song, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.217-222
    • /
    • 2001
  • For the life evaluating of notched members, it is the best way that performing the real fatigue test of structure containing notch. But this method required generally much times and costs to evaluate fatigue life. So, generally we use the modified S-N curve or several methods to predict fatigue life. In this study, crack initiation life was evaluated by fatigue testing the SAE keyhole specimen and smooth specimen made of Al 7075-T6 alloys using the constant load then obtained S-N curve of smooth specimen and P-N curve of SAE keyhole specimen. And, fatigue lives of keyhole specimen are predicted using some life prediction methods (Nominal range I method, Nominal range II method, FEM analysis) for investigating experimented results, and that were compared with experimental data. Predicted fatigue lives by FEM analysis were corresponded with experimental data between 1/3times and 3times on the whole, and predicted fatigue lives using modified S-N curve (Nominal range I method, Nominal range II method) were nonconservative compared with that of FEM analysis.

  • PDF

비정질 실리콘을 이용한 방사선 계측시 Photoconductive Gain의 특성

  • Lee, Hyeong-Gu;Sin, Gyeong-Seop
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.307-313
    • /
    • 1997
  • he photoconductive gain mechanism in amorphus silicon devices was investigated in connection with applications to radiation detection. Various device types such as p-i-n, n-i-n and i-i-p-i-n structures were fabricated and tested. Photoconductive gain was measured in two time scales : one for short pulses of visible light(<$1{\mu}sec$) which simulate the transit of energetic charged particles or ${\gamma}$-rays, and the other for rather long pulses of light(1msec) which simulate x-ray exposure in medical imaging, We used two definitions of phtoconductive gain : current gain and charge gain which is an integration of the current gain. We obtained typical charge gains of 3~9 for short pulses and a few hundreds for long pulses at a dark current density level of 10mA/$cm^2$. Various gain results are discussed in terms of the device structure, applied bias and dark current density.

  • PDF

Analysis and Comparison of Physicochemical Characteristics of First-Grade Soils from Ecological and Nature Map -Focused on Igneous Rocks Area- (생태·자연도 1등급 토양의 물리화학적 특성에 대한 분석 및 비교 -화성암 지역을 중심으로-)

  • So-Jin Lee;Chang-Oh Choo;Gyo-Cheol Jeong;Jong-Tae, Kim
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.61-68
    • /
    • 2023
  • This study analyzed and compared the physicochemical characteristics of topsoil and subsoil of Grade 1 soil from an igneous rock area on the ecological and nature map. The water content and pH of the collected soil samples were measured, and X-ray fluorescence and X-ray diffraction analyses were performed. The results showed that the water content of the topsoil was higher than that of the subsoil, and its pH was more acidic than that of the subsoil. According to the X-ray fluorescence analysis results, sample I9 was closest to kaolinite, while sample I7 was most distant from kaolinite. All other samples were located between samples I7 and I9. The X-ray diffraction analysis showed that the average content of clay minerals was higher in the topsoil than in the subsoil. The most notable clay minerals produced included illite, vermiculite, kaolinite, chlorite, and gibbsite. The results of this study will be used as a basic data for topsoil restoration to convert subsoil into topsoil.

Analysis of the Signal Properties of Polycrystalline $HgI_2$ Film Detector under Radiographic Irradiation Condition (X-선촬영 조사 조건하에서 다결정 요오드화수은 박막검출기의 신호특성 분석)

  • Kim, Jong-Eon
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.289-294
    • /
    • 2010
  • The purpose of this study is an evaluation of the performance of a detector under radiographic irradiation condition by fabricating the polycrystalline $HgI_2$ film detector. The polycrystalline $HgI_2$ film detectors with thickness of 210 and $320\;{\mu}m$ were fabricated by screen print technology. Measurements of X-ray sensitivity and dark current were performed for two detectors. And measurements of the linearity of X-ray response and reproducibility were performed for the detector of thickness $320\;{\mu}m$. For applied electric field strengths from 0.05 to $2\;V/{\mu}m$ to the detector of thickness $320\;{\mu}m$, the X-ray sensitivities were measured from 233 to $1,408{\times}106\;electrons/mR{\cdot}mm^2$. And the dark currents were measured from 3.2 to $118\;pA/mm^2$. Compared with values reported by Zhong Su et al., the X-ray sensitivities exhibit about two times larger than the X-ray sensitivities measured by Zhong Su et al. And the dark currents exhibit about nine times larger than the dark currents measured by Zhong Su et al. The linearity of X-ray response acquired 0.988 as a coefficient of correlation (r). Reproducibility acquired 0.002 as a coefficient of variation. This study provides the performance data of fabricated polycrystalline $HgI_2$ film detector available for an active matrix flat panel imager under radiographic irradiation condition.

Density control of ZnO nanowires using PDOT:PSS (PDOT:PSS를 이용한 ZnO 나노선의 밀도조절)

  • No, I.J.;Shin, P.K.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1451-1452
    • /
    • 2011
  • ZnO 나노선을 수열합성법을 이용하여 합성 하였다. ZnO 나노선을 이용하여 고효울 소자 제작하기 위해 반듯이 필요한 조건인 밀도 조절을 위해 PDOT:PSS를 에어브로쉬를 이용하여 분사하여 Dot의 형태로 열처리 한후 나노선을 합성 하였고 SEM 이미지를 통하여 밀도가 조절된 것을 확인 하였다.

  • PDF

Electronic characteristics of nanowire-nanoparticle-based FETs (나노선-나노입자 결합에 따른 FETs 전기적 특성 고찰)

  • Kang, Jeong-Min;Keem, Ki-Hyun;Jeong, Dong-Young;Yoon, Chang-Joon;Yeom, Dong-Hyuk;Kim, Sang-Sig
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1339-1340
    • /
    • 2007
  • 본 연구에서는 이종 차원 나노선과 나노입자의 결합에 따른 단일 나노선 소자의 전기적 특성 및 메모리 효과를 연구하였다. 열증착법으로 성장 된 p 형 Si 나노선에 Atomic Layer Deposition (ALD) 방법으로 10nm의 $Al_{2}O_{3}$를 증착한 후 Low Precensure - Chemical Vapor Deposition (LP-CVD)를 이용하여 Polycrystalline Sicon(Poly-Si)을 Si 나노선 위에 5nm 증착하고 습식 에칭법을 이용하여 poly Si 내의 $SiO_x$를 제거하여 Si 나노입자를 Si 나노선 위에 형성시켰다. 그 후 포토리소그래피 공정을 이용하여 Top gate 형태의 나노선-나노입자 이종결합 Field-Effect Transistor (FET) 소자를 제작하여 게이트 전압에 따른 드레인 전류-전압($I_{DS}-V_{DS}$)의 변화를 측정하여 나노선의 전기 소자로서의 특성을 확인하고, 게이트 전압을 양방향으로 swing 하면서 인가하여 $I_{DS}$ 전류 특성이 변화하는 것을 통해 메모리 효과를 조사하였다. 또한 나노입자의 결합이 게이트 전압의 인가 시간에 따라 드레인 전류에 영향을 미치는 것을 확인하여 메모리 소자로서의 가능성을 확인하였다.

  • PDF

Experimental Study for Phase-contrast X-ray Imaging Based on a Single Antiscatter Grid and a Polychromatic X-ray Source (단일 비산란 그리드 및 다색광 x-선원 기반 위상대조 x-선 영상화 실험 연구)

  • Park, Yeonok;Cho, Hyosung;Lim, Hyunwoo;Je, Uikyu;Park, Chulkyu;Cho, Heemoon;Kim, Kyuseok;Kim, Guna;Park, Soyoung
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.215-222
    • /
    • 2015
  • In this work, we performed a proof-of-concept experiment for phase-contrast x-ray imaging (PCXI) based on a single antiscatter grid and a polychromatic x-ray source. We established a table-top setup which consists of a focused-linear grid having a strip density of 200 lines/inch, a microfocus x-ray tube having a focal-spot size of about $5{\mu}m$, and a CMOS-type flat-panel detector having a pixel size of $48{\mu}m$. By using our prototype PCXI system and the Fourier demodulation technique, we successfully obtained attenuation, scattering, and differential phase-contrast images of improved visibility from the raw images of several selected samples at x-ray tube conditions of $90kV_p$ and 0.1 mAs. Further, fusion image (e.g., the attenuation+the scattering) may have an advantage in displaying details of the sample's structures that are not clearly visible in the conventional attenuation image. Our experimental results indicate that single-grid-based approach seems a useful method for PCXI with great simplicity and minimal requirements on the setup alignment.