• Title/Summary/Keyword: P-D value

Search Result 2,143, Processing Time 0.038 seconds

The Relationship Between Smoke-Yields and Tipping Materials of the Cigarette (담배 연기발생과 Tipping 재료와의 상관성 연구)

  • Kim, Young-Hoh;Lee, Young-Taek;Kim, Sung-Han;Kim, Chung-Ryul;Kim, Jong-Yeol;Shin, Chang-Ho;Lee, Keun-Hoi
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.1
    • /
    • pp.131-138
    • /
    • 1998
  • In order to minimize the trial frequency in the new filter cigarette design, we studied the relationship between smoke yield and tipping materials of cigarette. A three levels full factorial design involving filament denier (X1,2.5-3.3d), Porosity of the acetate filter plug wrap (X2, 3,500-16,000CU) and porosity of the tip paper (X3, 400-1,200CU) was used. Three independent factors (Xl, X2, X3) were chosen for their effects on the various responses and the function was expressed in terms of a quadratic polynomial equation, Y : $\beta$o + $\beta$1Xl + $\beta$2X2 + $\beta$3X3 + $\beta$11Xl2 + $\beta$22X22+ $\beta$33X32 + $\beta$12X1X2 + $\beta$13XIX3 $\beta$23X2X3 which measures the linear, quadratic, and interaction effects. Twenty-nine trial numbers were obtained as a results of using a three levels full factorial design and it was analyzed by the multiple regression analysis with backward stepwise in STATISTICA/pc under restricted conditions. Tar yields of the cigarette was affected by porosity of tip paper (0.66), filament denier (0.47) and porosity of plug wrap (0.28) in the decreasing order, and linear effect of tip paper porosity (B3) and filament denier (91) were significant at a level of 0.01($\alpha$). The filament denier and tipping paper porosity interaction F ratio among three factors had a P-value of 0,000041, indicating higher interaction between these factors. Based on the analysis of variance, the model fitted for Tar (Y1) was significant at 5% confidence level and the coefficient of determination (0.96) was the proportion of variability in the data fitted for by the model.

  • PDF

Estimating the Ovulation Time Based on Plasma Estradiol-$17{\beta}$ and Progesterone Concentrations in Miniature Schnauzer Dogs (Miniature Schnauzer 견에서 혈중 Estradiol-$17{\beta}$와 Progesterone 농도 측정에 의한 배란시기 추정)

  • Kim, Jeong-Bae;Kim, Bang-Sil;Mun, Byeong-Gwon;Yun, Chang-Jin;Park, Chul-Ho;Moon, Jin-San;Suh, Guk-Hyun;Oh, Ki-Seok;Son, Chang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.25 no.2
    • /
    • pp.79-84
    • /
    • 2008
  • For estimating the ovulation time in Miniature Schnauzer dogs during the estrous cycle, radioimmunoassay of plasma estradiol-$17{\beta}$ and progesterone concentrations was conducted on blood samples in 21 pregnant and 13 non pregnant dogs. When Day 0 was that plasma progesterone concentrations exceeded 4.0 ng/ml, on Day 64, parturition day, progesterone declined below 1.0 ng/ml with $0.92\;{\pm}\;0.29\;ng/ml$ and when Day 0 was that plasma progesterone concentrations declined below 1.0 ng/ml, on Day -64, progesterone increased above 4.0 ng/ml with $4.56\;{\pm}\;0.87\;ng/ml$. Gestational length was $63.71\;{\pm}\;1.35$ (Mean${\pm}$S.D.) days from plasma progesterone concentrations exceeded 4.0 ng/ml and was $66.29\;{\pm}\;1.98$ days from first male acceptance. The plasma estradiol-$17{\beta}$ concentrations reached maximum value with $28.20\;{\pm}\;2.86\;pg/ml$ on Day .2, and plasma progesterone concentrations reached $5.90\;{\pm}\;0.36 ng/ml, 5.18\;{\pm}\;0.32 ng/ml on Day 0, and the maximum of 61.58\;{\pm}\;10.47 ng/ml on Day 19 and 56.05\;{\pm}\;8.86\;ng/ml$ on Day 16 in pregnant and non pregnant dogs, respectively. Afterward, plasma progesterone concentrations declined below 1.0 ng/ml on Day 64 with $0.92\;{\pm}\;0.29\;ng/ml$ in pregnant cycles and on Day 58 with $0.95\;{\pm}\;0.63\;ng/ml$ in non pregnant dogs. No difference were found pregnant and non pregnant dogs in plasma estradiol-$17{\beta}$ and progesterone concentrations (p<0.01). Based on first male acceptance (Day 0), the maximum of plasma estradiol-$17{\beta}$ concentrations ($29.31\;{\pm}\;3.61\;pg/ml$) occurred on Day -1 and plasma progesterone concentrations exceeded 4.0 ng/ml on Day 2 in pregnant ($5.37\;{\pm}\;0.76\;ng/ml$) and non pregnant ($4.25\;{\pm}\;0.80\;ng/ml$) dogs. These results suggest that in Miniature Schnauzers, the ovulation occurred when plasma progesterone concentrations exceeded 4.0 ng/ml, 3 days after plasma estradiol-$17{\beta}$ peak and 2 days after first male acceptance.

Antioxidant Activities of Rubus coreanus Miquel and Morus alba L. Fruits (복분자와 오디의 항산화 특성)

  • Jun, Hyun-Il;Kim, Young-Ae;Kim, Young-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.3
    • /
    • pp.381-388
    • /
    • 2014
  • The antioxidant activities of extracts from Rubus coreanus Miquel (black raspberry) and Morus alba L. (mulberry) fruits were investigated using 2,2-diphenyl-1-picrylhydrazyl (DPPH) assay, 2,2-azino-bis-(3-ethylbenzo-thiazoline-6-sulfonic acid) (ABTS) assay, and reducing power assay. Aqueous mixtures of ethanol, methanol, and acetone were analyzed in order to determine the most effective extraction solvent for the two fruits. Black raspberry and mulberry extracts with the 60:40 acetone-water mixtures (v/v) showed the highest DPPH radical scavenging activities (56.2 and 85.2%, respectively) compared to the other extraction solvents. The 60% acetone extract was finally selected as an extraction solvent and then sequentially fractionated according to solvent polarity. Among the fractions of the two fruits, the ethyl acetate fraction showed the highest antioxidant activity as well as total phenolic and total flavonoid contents. In addition, there were high correlation coefficients between antioxidant activities and their contents. The $EC_{50}$ value of the ethyl acetate fraction from mulberry fruit was 2.2 times lower than that of butylated hydroxytoluene (BHT) in DPPH assay. The major phenolic acid and anthocyanin of the two fruits were protocatechuic acid and cyanidin-3-glucoside, respectively.

Effect of Location, Season, and Variety on Yield and Quality of Forage Oat

  • Kim, J.D.;Kim, S.G.;Abue, S.J.;Kwon, C.H.;Shin, C.N.;Ko, K.H.;Park, B.G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.7
    • /
    • pp.970-977
    • /
    • 2006
  • Forage oat (Avena sativa L.) is grown extensively in a double-cropping system on dairy farms. Four oat varieties ('Swan', 'Targa', 'Foothill', and 'Nugene') were evaluated for forage production and forage quality during two growing seasons (spring and autumn) at two locations (central and southern region) in South Korea. The heading stage of four oat varieties was observed during spring, but the autumn season did not produce heading until harvest time except for the 'Swan' variety (early-maturing variety). The heading stage of 'Swan' in both locations was earlier compared to other varieties. The four varieties were resistant to both foliar disease and insects. Lodging resistance was higher during autumn except in 2002 at the central region, and late-maturing varieties ('Foothill' and 'Nugene') have lower lodging resistance. Dry matter (DM) content was significantly different between varieties (p<0.001). Comparing different varieties, 'Swan', an early-maturing variety, was highest in DM content. In DM, total digestible nutrients (TDN) and crude protein (CP) yield, the yield of oat varieties in the southern region was higher than in the central region, and forage yield of the oat varieties in the spring season was higher than during the autumn season. The DM and TDN yield showed significant differences between oat varieties. The CP content of oats grown in the central region (Cheonan) was lower than oats grown in the southern region (Daegu), and the spring season produced oats with lower CP compared to the autumn season. Among the four oat varieties, the CP content of late-maturing varieties was higher than the Swan variety (early-maturing variety). The acid detergent fiber (ADF) and neutral detergent fiber (NDF) contents were higher for the varieties grown in Cheonan and during the spring season. The ADF and NDF contents of late-maturing varieties were lower than the early-maturing variety. TDN and relative feed value (RFV) were higher for the varieties grown in Daegu and during the autumn season. Late-maturing variety had higher TDN and RFV than early-maturing variety. Our study showed differences in forage production and forage quality of oats grown in different locations, seasons and varieties. Forage quality as well as forage production was better in the southern region than in the central region. Forage quality was better during autumn, but forage production was better during spring. Late-maturing variety had better forage quality than the early-maturing variety. Therefore, late-maturing varieties are more suitable for use in the southern region.

Comparison by Measurement Sites in Temperature of Neonates : Ear-based rectal, Rectal, Axilla, Abdominal Temperature (측정부위별 신생아의 체온 비교 : 고막기준 직장체온, 직장체온, 액와체온, 복부체온)

  • 김화순;안영미
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.4
    • /
    • pp.903-916
    • /
    • 1999
  • The purpose of this study was to compare the ear-based rectal temperature measured with a tympanic thermometer with the rectal temperature measured with a glass mercury thermometer in order to test the accuracy of tympanic thermometer and to determine relationship among rectal, axilla, and abdominal temperature in neonates. The samples consisted of thirty four neonates admitted to the neonatal intensive care unit and nursery at an university affiliated hospital. The mean age of the subjects was 4.9 days. The ear-based rectal temperatures were taken with a tympanic thermometer in rectal mode (First Temp Genius 3000). Rectal and axilla temperatures were taken with a glass mercury thermometer, Abdominal temperature was continuously monitored with the probe connected to the servo controller of incubator. The results of the study can be summarized as follows : 1. Intrarater comparison : Agreement between the first and the second ear-based rectal temperature was 97% within 0.1$^{\circ}C$. 2. Comparison of ear-based rectal temperature and the rectal temperature from a glass mercury thermometer : ear-based rectal temperature ranged from 36.95$^{\circ}C$d to 37.95$^{\circ}C$, with a mean of 37.58$^{\circ}C$(SD=0.22$^{\circ}C$). Rectal temperature from a glass mercury thermometer ranged from 36.2$0^{\circ}C$ to 37.2$0^{\circ}C$, with a mean 36.75$^{\circ}C$(SD=0.29). The mean difference between both temperatures was 0.84$^{\circ}C$. The correlation coefficient between both temperatures was r=0.77(p=0.00). 3. Comparison of rectal and axilla temperature : Axilla temperature ranged from 35.8$0^{\circ}C$ to 37.1$0^{\circ}C$, with a mean of 36.55$^{\circ}C$. The mean absolute difference between the rectal and axilla temperature was 0.23$^{\circ}C$. The correlation coefficient between rectal and axilla was r=0.67. 4. Comparison of axilla and abdominal temperature : Abdominal temperature ranged from 36.2$0^{\circ}C$ to 37.0$0^{\circ}C$, with a mean of 36.58$^{\circ}C$. The mean absolute difference between axilla and abdominal temperature was only -0.03$^{\circ}C$. Findings of this study suggest that ear-based rectal temperature overestimates the actual rectal temperatures in neonates. Therefore, the interchangeble use of both temperatures in clinics seems problematic. The site offset(adjustment value) programmed in rectal mode of the tympanic thermometer needs to be readjusted. Choosing one optimal site for temperature measurement for each patient, and using the specific site consistently would result in more consistent measurements of changes in body temperature, and thus can be more effective in diagnosing fever or hypothermia.

  • PDF

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • Lee, Su-Won;Jeong, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Jeong, Yong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF

Transbuccal versus transoral approach for management of mandibular angle fractures: a prospective, clinical and radiographic study

  • Khandeparker, Purva Vijay Sinai;Dhupar, Vikas;Khandeparker, Rakshit Vijay Sinai;Jain, Hunny;Savant, Kiran;Berwal, Vikas
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.3
    • /
    • pp.144-150
    • /
    • 2016
  • Objectives: We compared the transbuccal and transoral approaches in the management of mandibular angle fractures. Materials and Methods: Sixty patients with mandibular angle fractures were randomly divided into two equal groups (A, transoral approach; group B, transbuccal approach) who received fracture reduction using a single 2.5 mm 4 holed miniplate with a bar using either of the two approaches. Intraoperatively, the surgical time and the ease of surgical assess for fixation were noted. Patients were followed at 1 week, 3 months, and 6 months postoperatively and evaluated clinically for post-surgical complications like scarring, infection, postoperative occlusal discrepancy, malunion, and non-union. Radiographically, the interpretation of fracture reduction was also performed by studying the fracture gap following reduction using orthopantomogram tracing. The data was tabulated and subjected to statistical analysis. A P -value less than 0.05 was considered significant. Results: No significant difference was seen between the two groups for variables like surgical time and ease of fixation. Radiographic interpretation of fracture reduction revealed statistical significance for group B from points B to D as compared to group A. No cases of malunion/non-union were noted. A single case of hypertrophic scar formation was noted in group B at 6 months postsurgery. Infection was noted in 2 patients in group B compared to 6 patients in group A. There was significantly more occlusal discrepancy in group A compared to group B at 1 week postoperatively, but no long standing discrepancy was noted in either group at the 6 months follow-up. Conclusion: The transbuccal approach was superior to the transoral approach with regard to radiographic reduction of the fracture gap, inconspicuous external scarring, and fewer postoperative complications. We preferred the transbuccal approach due to ease of use, minimal requirement for plate bending, and facilitation of plate placement in the neutral mid-point area of the mandible.

Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor ($BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교)

  • Choi, Jang-Yong;Park, Ji-Koon;Gong, Hyun-Gi;Ahn, Sang-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

Effects of Changes in Exercise Intensity on Resting Metabolic Rate (RMR) and Energy Expenditure in Young Men (운동강도의 차이가 안정시대사량 및 에너지 소비량에 미치는 영향)

  • Kawk Yi-Sub;Jin Young-Wan;Park Chan-Ho
    • Journal of Life Science
    • /
    • v.15 no.3 s.70
    • /
    • pp.352-358
    • /
    • 2005
  • The purpose of this study was to examine the effect of various exercise intensity on Resting Metabolic Rate (RMR), excess post exercise energy expenditure (EPEE), and thyroid hormonal changes in trained (TR) and untrained (UT) people. The subject of the present study were divided into two groups and four periods: trained (TR; n=6) and untrained (UT; n=6) group. And the periods were divided as follows; Resting (R), Maximal (M), High intensity (H), and Low intensity (L). The percent body fat and RMR of all subjects were measured at every periods. The RMR was measured early in the morning following a 12-hour fast using MMX3B gas analyzer and blood sample were collected from the anticubital vein to investigate thyroid hormonal (T3, T4, Free T3, Free T4, & TSH) changes. All the RMR values were expressed as absolute value/BSA $(kcal/d/m^2)$. And We also analyzed mean energy expenditure for 30 minutes during and after different intensity exercise. There was significant difference in RMR among different intensity of exercise. in TR (p < .05) not in the UT group. however, there was no significant different percent body fat in TR and in UT group. In the energy expenditure, there was significant different between TR and UT in HEE (high intensity exercise energy expenditure), LEE (low intensity exercise energy expenditure), HEEPE (high intensity exercise energy expenditure post exercise) & LEEPE (low intensity exercise expenditure post exercise). In the hormonal level, there was significant different in T4 level in the TR group at H period and in T4, Free T3, & Free T4 levels in TR group at L period, however there was no significant different in the UT group. The present cross-sectional study was design to investigate the relationship between exercise intensity and RMR. The focus of this investigation was to compare RMR in aerobically trained (TR) and untrained (VI). The relationship among RMR, exercise intensity and percent body fat would best be investigated using MMX3B and body composition analyzer. Each subject completed measurement of percent body fat, RMR, hormone in the period of maximal oxygen uptake exercise (M), high intensity exercise (H), and low intensity exercise (L). From the results, Low intensity of exercise (L), there was a trend for an increased RMR (kcal/day) in the TR not for the UT. This is best explained not by the reduced percent body fat but by the highly induced energy expenditure (during exercise and post exercise energy expenditure) and increased T4, Free T3, and Free T4 hormonal levels in the low intensity exercise for the TR group.

Changes of Soil Properties and Evaluation of Plant Utilization According to the Application of Compost Used with Phyllite (Phyllite를 이용한 퇴비 시용에 따른 토양 특성 변화 및 작물에 대한 효용성 평가)

  • Park, Young-Hee;Chang, Ki-Woon;Hong, Jei-Gu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.2
    • /
    • pp.92-99
    • /
    • 2002
  • The study was conducted to investigate the changes of soil properties and evaluation of plant utilization according to the application of compost used with phyllite. At this experiment, the plant cultivation test(lettuce and radish plant) was carried out to know about physico-chemical properties of compost, humus degradarion and stabilization degree, and some effects among rhe treatments were best at 20Mg/ha in PSPC 10(Phyllite, Saw dust, Pig manure Compost) plots and ar 10Mg/ha in PSPC 20 treatments, respectively. The EC value was high in the compost. Therefore the EC was appeared more than 2ds/m at the applied 40Mg/ha with compost. And in case of lettuce, Avail.-$P_2O_5$ and EC were more increased than in the radish plots, highly. In contrast, in case of radish, Toral-N, Total-C, and EC contents were decreased after plant cultivation. That is, it could know that radish was fond of absorprion of nitrogen. Also, BD values of soil physical properties were decreased according to increasing of phyllite addition ratio, however water holding capacity(WHC) was increased. The plant test had not been darnaged through the application of compost used with phyllite in soil and there had not been worse on changing of soil physico-chemical properties. Consequently, phyllite composts have been thought on agricultural utilized possibility.

  • PDF