• Title/Summary/Keyword: P-1 radiation model

Search Result 173, Processing Time 0.034 seconds

Signal Transduction Factors on the Modulation of Radiosusceptibility in K562 Cells (K562 세포의 방사선 감수성 변화에 영향을 미치는 신호전달인자)

  • Yang Kwang Mo;Youn Seon-Min;Jeong Soo-Jin;Jang Ji-Yeon;Jo Wol-Soom;Do Chang-Ho;Yoo Y대-Jin;Shin Young-Cheol;Lee Hyung Sik;Hur Won Joo;Lim Young-Jin;Jeong Min-Ho
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.227-237
    • /
    • 2003
  • Purpose: The human chronic myelogenous leukemia cell line, K562, expresses the chimeric bcr-abl oncoprotein, whose deregulated protein tyrosine kinase activity antagonizes via DNA damaging agents. Previous experiments have shown that nanomolar concentrations of herbimycin A (HWA) coupled with X-irradiation have a synergistic effect in inducing apoptosis in the Ph-positive K562 leukemia cell line, but genistein, a PTK inhibitor, is non selective for the radiation-induced apoptosils on $p210^{bcr/abl}$ protected K562 cells. In these experiments, the cytoplasmic signal transduction pathways, the Induction on a number of transcription factors and the differential gene expression in this model were investigated. Materials and Methids: K562 cells in the exponential growth phase were used in this study. The cells were irradiated with 0.5-12 Gy, using a 6 Mev Linac (Clinac 1800, Varian, USA). Immediately after irradiation, the cells were treated with $0.25/muM$ of HMA and $25/muM$ of genistein, and the expressions and the activities of abl kinase, MAPK family, NF- kB, c-fos, c-myc, and thymidine kinase1 (TK1) were examined. The differential gene expressions induced by PTK inhibitors were also investigated. Results: The modulating effects of herbimycin A and genistein on the radiosensitivity of K562 cells were not related to the bcr-abl kinase activity. The signaling responses through the MAPK family of proteins, were not involved either in association with the radiation-induced apoptosis, which is accelerated by HMA, the expression of c-myc was increased. The combined treatment of genistein, with irradiation, enhanced NF- kB activity and the TK1 expression and activity. Conclusion: The effects of HMA and genistein on the radiosensitivity on the K562 cells were not related to the bcr-abl kinase activity in this study, another signaling pathway, besides the WAPK family responses to radiation to K562 cells, was found. Further evaluation using this model will provide valuable information for the optional radiosensitization or radioprotection.

Effects of Water Microspraying, Foliar Application of Calcium Carbonate and Kaolin Solution on Sunburn and Quality of Fruits in Satusma Mandarin (미세살수와 탄산칼슘 및 카올린 엽면살포가 온주밀감의 일소 발생과 과실 품질에 미치는 영향)

  • Joa, Jae-Ho;Kang, Seok-Beom;Park, Yo-Sup;Kim, Mi-Sun;Kim, Ha-Neul;Oh, Bok-Shim
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.261-269
    • /
    • 2022
  • This study was carried out to predict fruit surface temperature (FST) causing sunburn symptoms and assess the correlation between solar radiation and FST in satusma mandarin (Citrus unshiu Marc. 'Iwasaki'). And to reduce sunburn when ambient temperature was at 31℃, sprinkler system was repeated spraying every at 5 minutes of 30 minutes intervals and 1% calcium carbonate and 4% kaolin solution applied on citrus tree three times to investigate quality and sunburn of fruits. It showed highly significant positive correlation between FST and solar radiation (R = 0.788, p < 0.01), The FST increased up to 16℃ than ambient temperature at daytime. To estimate FST, a linear model y = 0.099 × (air temperature) + 0.018 × (solar radiation) + 20.779 (R = 0.687, p < 0.01) was derived. The canopy temperature of citrus trees was 5.1℃ lower in sprinkler system than in control. The incidence of sunburn showed at 2.1% in sprinkler system twice lower than in control and there was different significance. Fruit quality was similar between treatments. In conclusion, sunburn can be reduced by reflecting sunlight or downing of FST through sprinkler system.

Application of Numerical Model for the Effective Design of Large Scale Fire Calorimeter (화재발열량계의 효율적 설계를 위한 수치해석 모델의 적용)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.28-33
    • /
    • 2010
  • The present study develops a numerical model based on the computational fluid dynamics technique to analyse the thermal flow characteristics of large scale fire calorimeter and examine the characteristics of primary parameters affecting on the uncertainty of heat release rate measurement. ANSYS CFX version 12.1 which is a commercial CFD package is used to solve the governing equations of the thermal flow field and the eddy dissipation combustion model and P-1 radiation model are applied to simulate the fire driven flow. The numerical results shows that the horizontal duct system with $90^{\circ}$ bend duct was shown relatively high deviated asymmetric flow profiles at the sampling location and the deviation of the velocity field was higher than that of the temperature and species quantities. The present study shows that the computational model can be applicable to optimize the design process and operating condition of the large scale fire calorimeter based on the understanding of the detail flow field.

Result of Radiation Therapy of Cerebellar Medulloblastoma - with Emphasis on the Neuraxis Dose - (전중추신경계 조사선량을 중심으로 한 수아세포종의 방사선치료성적)

  • Kim Joo Young;Kim Il Han;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.69-77
    • /
    • 1993
  • Treatment of cerebellar medulloblastoma has been much improved with modern surgical technique for gross total tumor removal and adequate radiation therapy for the whole craniospinal axis. Questions have been arosen about the optimal radiation dose for the preventive treatment of whole cranium and whole spinal axis. Recently, many authors have reported their treatment results as comparable to older data, using lower than conventional dose of 3,600 cGy-4,000 cGy. For 50 patients treated between 1981 and 1990 at the Department of Radiation Therapy of SNUH, retrospective analysis was done for the treatment result, especially the neuraxis control, by radiation dose for the presymptomatic area of the disease. Analysis only by total spinal dose did not give any significant difference. But further analysis by following patient group; 3,600 cGy/150 cGy (n=6), 3,000 cGy/150 cGy (n=10), 2,400 cGy/150 cGy (n=17) and 2,400 cGy/100-120 cGy (n=11) showed significant improvement of neuraxis control by decreasing order (p =0.003). There was no significant difference in overall survival between the groups. For the 19 patients who had been confirmed initially as having no neuraxis disease, TDF 30 was the cur-off value that could prevent neuraxis failure (p =0.004). We couldn't define any TDF value that give reasonable control for the patient group with positive CSF study at initial diagnosis.

  • PDF

Prognostic Factors for Local Control in Early Glottic Cancer Treated with Radiation Therapy (방사선치료를 받은 조기 성문암 환자의 국소 종양 제어에 관한 예후 인자)

  • Chung Woong-Ki;Ahn Sung Ja;Nam Taek Keun;Nah Byung Sik;Cho Jae-Shik;Lim Sang-Chull
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.226-232
    • /
    • 2000
  • Purpose :This study was performed to find out the prognostic factors affecting local control in early glottic cancer treated with radiation therapy alone. Materials and Methods :We analysed 37 patients of histologically confirmed early glottic cancer treated at Chonnam National University Hospital between July Im and December 1995, retrospectively. Age of patients ranged from 30 to 73 years (median; 59 years). Thirty-five (95$\%$) patients were male. Histological type was all squamous cell carcinoma. According to the staging system of 1997 American Joint Committee on Cancer, 37 patients were restaged as follows: Tla; U (73$\%$), Tlb; 3 (8$\%$), 72: 7 (19$\%$). Radiation therapy was done using 6 MV X-ray of linear accelerator The range of total radiation dose delivered to the glottic lesion was between 5,040 cGy and 7,020 cGy (median; 6,600 cGy). Median follow-up period was U months. local control rates were calculated by Kaplan-Meier method. Generalized Wilcoxon test was used to evaluate the difference of control rates between comparable groups. Multivariate analysis using Cox proportional hazard model was done to find out prognostic factors affecting local control. Results:5 year survival rate of 37 patients was 89$\%$. Local control rate of 37 patients was 74$\%$ in 5 years. We included age, 7-stage, anterior commissure involvement, fraction size, total radiation dose, treatment time of radiotherapy as potential prognostic factors in univariate and multivariate analysis. As a result, treatment time had statistical significance in local control rate in both univariate (p=0.026) and multivariate (p=0.017) analysis. Complication was not recorded except one patient with hypothyroidism. Conclusion :This study revealed that overall treatment time of radiation was a significant factor affecting local control rate.

  • PDF

The apoptotic fragment assay in rat peripheral lymphocytes and crypt cells with whole body irradiation with 60Co ϒ-rays and 50 MeV cyclotron fast neutrons (코발트-60 감마선과 50 MeV 싸이크로트론 고속 중성자선에 전신조사된 랫드의 말초 임파구와 음와 세포의 아포토시스 유도를 이용한 생물학적 선량 측정 모델 개발 연구)

  • Kim, Tae-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.2
    • /
    • pp.203-210
    • /
    • 2001
  • Here, we compared the effectiveness of 50 MeV($p{\to}RBe^+$) cyclotron fast neutrons versus $^{60}Co$ ${\gamma}$-rays by the apoptotic fragment frequency in both rat peripheral lymphocytes and crypt cells to check a radiobiological endpoint. The incidence of apoptotic cell death was increased in all irradiated groups, and radiation at all doses trigger rapid changes in both crypt cells and peripheral lymphocytes. These data suggest that apoptosis may play an important role in homeostasis of damaged radiosensitive target organ by removing damaged cells. The curve of dose-effect relationship for these data of apoptotic fragments frequencies was $y=0.3+(6.512{\pm}0.279)D(r^2=0.975)$ after neutrons, while $y=0.3+(4.435{\pm}0.473)D+(-1.300{\pm}0.551)D^2(r^2=0.988)$ after ${\gamma}$-rays. In addition, $y=3.5+(118.410{\pm}10.325)D+(-33.548{\pm}12.023)D^2(r^2=0.992)$ after ${\gamma}$-rays in rat lymphocytes. A significant dose-response relationship was found between the frequency of apoptotic cell and dose. These data show a trend towards increase of the numbers of apoptotic cells with increasing dose. Dose-response curves for high and low linear energy transfer (LET) radiation modalities in these studies were different. The relative biological effectiveness (RBE) value for crypt cells was 1.919. In addition, there were significant peaks on apoptosis induction at 4 and 6h after irradiation, and the morphological findings of the irradiated groups were typical apoptotic fragments in crypt cells that were hardly observed in the control group. Thus, apoptosis induction in both crypt cells and peripheral lymphocytes could be a useful endpoint of rat model for studying screening test and microdosimetic indicator to evaluate the biological effects of radiation-induced cell damage.

  • PDF

The Crystal and Molecular Structure of Niclosamide monohydrate, $C_{13}H_8Cl_2N_2O_4\cdotH_2O$ (Niclosamide monohydrate, $C_{13}H_8Cl_2N_2O_4\cdotH_2O$의 결정 및 분자구조)

  • 김의성;신현소
    • Korean Journal of Crystallography
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 1993
  • The crystal structure of N-(2'-chloro-4'-vitrophenyl)-5-chlorosalicylamide( Niclosamide ) monohydrate has been determined from 1976 sig- nificant independent reflections collected on an automated CAD4 diffractometer using graphitemonochromated Mo-Ka radiation. The crystal is monoclinic, space group P211c, with unit cell dimensions, a=11.331 (3), b=16.964(2), c=7.347(4)A , P =98.20(3)° and Z=4 at T=293k. The structure was solved by direct method using seminvariants of ggg Parity group and refined by the full-matrix least-square method, resulting model with reliability factor, R=0.046. The feature of the molecule show planar structure in parallel to the ab crystal plane.

  • PDF

Association between dental X-ray exposure and the thyroid cancer risk: A meta-analysis of case-control studies

  • Hwang, Su-Yeon;Kim, Hae-Young;Song, Sun-Mi;Choi, Eun-Sil
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.269-279
    • /
    • 2020
  • Objectives: Previous studies have reported inconsistent findings in the association between dental diagnostic X-ray exposure and thyroid cancer. This study was a meta-analysis of case-control studies evaluating the association between exposure to dental radiation and the thyroid cancer risk. Methods: We searched the PubMed and EMBASE databases to identify studies on dental radiation and thyroid cancer risks that were published up to September 2018. Quality of studies was assessed using the Newcastle-Ottawa scale. A fixed-effects model was used to estimate pooled odds ratios (ORs) and 95% confidence intervals (CIs) using STATA 14.0. Potential publication biases were evaluated using Egger's test and Begg's funnel plot. Results: From the literature search, we included six case-control studies in this meta-analysis. The meta-analysis using the fixed-effects model found that dental X-ray exposure was associated with 2.34 times increased risk for thyroid cancer (OR=2.34, 95% CI=1.79-3.21). There was no heterogeneity in the data (p=0.662, I2 =0%). Egger's test showed that there was no publication bias (p=0.532). Conclusions: This meta-analysis confirmed the association of dental X-ray exposure and thyroid cancer risk. The current results underscore the importance of applying safety regulations at dental clinics to protect thyroid glands during dental radiography examinations.

Prediction of Water Quality in Haenam Estuary Reservoir Using Multiple Box Model (I) -Development and Application of Water Quality Subroutines- (Multiple Box 수질모형에 의한 해남호 수질예측 (I) - 수질부 모형의 개발과 적용 -)

  • 신승수;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.116-129
    • /
    • 1990
  • A rational management of water resources in estuary reservoirs necessiates the prediction of water quality. In this study, a multiple box model for the water quality prediction was developed as a tool for the purpose of examining an adequate way to improve and maintain the water quality. Some submodels that are suitable for simulating the mixing behavior of pollutant materials in a lake were considered in this model. The model was appiled for predicting water qualities of Haenam Esturay Reservoir. The result from this study can be summarized as follows : 1.A water quality simulation model that can predict the 10-day mean value of water qualities was developed by adding some submodels that simulate the concentrations of chlorophyll-a, BOD, T-P and T-N to the existing Multiple Box Model representing the mixing and circulating of materials by the hydarulic action. 2.As input data for the model developed, the climatic data including precipitation, solar radiation, temperature, cloudness, wind speed and relative humidity, and the water buget records including the pumping discharge and the releasing discharge by drainage gate were ollected. The hydrologic data for the inflow discharge from the watershed was obtained by simulation with the aid of USDAUL-74/SNUA watershed model. Also the water quality data were measured at streams and the reservoir. 3.As a result of calibration and verification test by using four comonents of water quality such as Chlorophyll-a, BOD, T-P and T-N, it was found that the correlation coefficeints between the observed and the simulated water qualities showed greater than 0.6, therefore the capability of the model to simulate the water quality was proved. 4.The result based on the model application showed that the water quality of the Haenam Estuary Reservoir varies seasonally with the harmonic trend, however the water quality is good in winter and get worse in summer. Also it may be concluded that the current grarde of water quality in the Heanam Esutary Reservoir is ranked as grade 4 suitable only for the agricultutal use.

  • PDF

Contrast Media in Abdominal Computed Tomography: Optimization of Delivery Methods

  • Joon Koo Han;Byung Ihn Choi;Ah Young Kim;Soo Jung Kim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2001
  • Objective: To provide a systematic overview of the effects of various parameters on contrast enhancement within the same population, an animal experiment as well as a computer-aided simulation study was performed. Materials and Methods: In an animal experiment, single-level dynamic CT through the liver was performed at 5-second intervals just after the injection of contrast medium for 3 minutes. Combinations of three different amounts (1, 2, 3 mL/kg), concentrations (150, 200, 300 mgI/mL), and injection rates (0.5, 1, 2 mL/sec) were used. The CT number of the aorta (A), portal vein (P) and liver (L) was measured in each image, and time-attenuation curves for A, P and L were thus obtained. The degree of maximum enhancement (Imax) and time to reach peak enhancement (Tmax) of A, P and L were determined, and times to equilibrium (Teq) were analyzed. In the computed-aided simulation model, a program based on the amount, flow, and diffusion coefficient of body fluid in various compartments of the human body was designed. The input variables were the concentrations, volumes and injection rates of the contrast media used. The program generated the time-attenuation curves of A, P and L, as well as liver-to-hepatocellular carcinoma (HCC) contrast curves. On each curve, we calculated and plotted the optimal temporal window (time period above the lower threshold, which in this experiment was 10 Hounsfield units), the total area under the curve above the lower threshold, and the area within the optimal range. Results: A. Animal Experiment: At a given concentration and injection rate, an increased volume of contrast medium led to increases in Imax A, P and L. In addition, Tmax A, P, L and Teq were prolonged in parallel with increases in injection time The time-attenuation curve shifted upward and to the right. For a given volume and injection rate, an increased concentration of contrast medium increased the degree of aortic, portal and hepatic enhancement, though Tmax A, P and L remained the same. The time-attenuation curve shifted upward. For a given volume and concentration of contrast medium, changes in the injection rate had a prominent effect on aortic enhancement, and that of the portal vein and hepatic parenchyma also showed some increase, though the effect was less prominent. A increased in the rate of contrast injection led to shifting of the time enhancement curve to the left and upward. B. Computer Simulation: At a faster injection rate, there was minimal change in the degree of hepatic attenuation, though the duration of the optimal temporal window decreased. The area between 10 and 30 HU was greatest when contrast media was delivered at a rate of 2 3 mL/sec. Although the total area under the curve increased in proportion to the injection rate, most of this increase was above the upper threshould and thus the temporal window was narrow and the optimal area decreased. Conclusion: Increases in volume, concentration and injection rate all resulted in improved arterial enhancement. If cost was disregarded, increasing the injection volume was the most reliable way of obtaining good quality enhancement. The optimal way of delivering a given amount of contrast medium can be calculated using a computer-based mathematical model.

  • PDF