• 제목/요약/키워드: P-1 radiation model

검색결과 176건 처리시간 0.021초

항문암의 동시 화학 방사선 요법 치료결과 (Concurrent Chemoradiotherapy Results in Patients with Anal Cancer)

  • 정원규;김수곤;이창걸;성진실;김귀언
    • Radiation Oncology Journal
    • /
    • 제12권1호
    • /
    • pp.99-107
    • /
    • 1994
  • Among the 63 patients with histopathologically proven primary squamous cell anal cancer who were managed in Presbyterian Medical Center and Yonsei University Cancer from Jan. 1971 to Dec. 1991, 34 patients, who were managed with surgery alone(abdominoperineal resection) or post-operative radiotherapy and concurrent chemoradiotherapy were analysed. With mean follow up time of 81.3 months, 30 Patients(88$ \% $) were followed up from 17 to 243 months. In methods, 10 patients were treated with surgery alone. 9 Patients were treated with combined surgery and postoperative radiotherapy(50$\∼$60 Gy in 28$\∼$30 fractions). 15 patients were treated with concurrent chemoradiotherapy. Chemotherapy (Mitomycin C 15 mg/squ, bolus injection day 1;5-FU, 750 mg/squ, 24hr infusion, day 1 to 5) and radiotherapy started the same day. A dose of 30 Gy was given to the tumor and to the pelvis including inguinal nodes, in 15 fractions. After 2 weeks a boost of radiotherapy(20 Gy) to the ano-perineal area and second cycle of chemotherapy completed the treatment. The overall 5-year survival rate was 56.2$ \% $. Concurrent chemoradiotherapy group was 70$ \% $ and surgery alone group was 16.7$ \% $. According to the cox proportional harzard model, there was significant difference between survival with concurrent chemoradiotherapy and surgery alone(p=0.0129), but post-operative radiotherapy was 64.8$ \% $, which was not stastically significant(p=0.1412). In concurrent chemoradiotherapy group, the anal funtion Preservation rate was 87$ \% $ and the severe complication rate(grade 3 stenosis and incontinence) was 13.3$ \% $. In conclusion, we conclude that the concurrent chemoradiotherapy may be effective treatment modality in patients with anal cancer.

  • PDF

유방암의 방사선치료에서 방사선학적 지표에 따른 폐 및 심장의 부작용 확률 (Probabilities of Pulmonary and Cardiac Complications and Radiographic Parameters in Breast Cancer Radiotherapy)

  • 노오규;박성호;안승도;최은경;이상욱;송시열;윤상민;김종훈
    • Radiation Oncology Journal
    • /
    • 제28권1호
    • /
    • pp.23-31
    • /
    • 2010
  • 목 적: 정상 장기의 부작용 확률(normal tissue complication probability, NTCP) 모델을 이용하여, 중심폐거리(central lung distance, CLD)와 최대심장거리(maximal heart distance)와 같은 이차원 방사선치료의 방사선학적 지표들과 삼차원 입체조형방사선치료의 부작용확률 사이의 관계를 평가해 보고자 하였다. 대상 및 방법: 2006년 11월부터 2007년 8월까지 서울아산병원에서 유방암으로 진단받고 수술 후 방사선치료를 시행 받은 110명을 무작위로 추출하여 분석하였다. 방사선치료는 2문 빗면 조사법, 3문 조사법, Reverse Hockey Stick법을 사용하였고, 유방 및 흉벽에는 5,040 cGy/28회, 쇄골 상부에는 4,500 cGy/25회로 조사하였고, 유방보존술을 시행한 경우에는 원발 병소에 1,000 cGy/4회의 추가치료를 하였다. 모든 환자에서 전산화단층촬영모의치료를 시행하였고, Eclipse Planning System을 사용하여 선량 계산을 시행 후 폐와 심장의 선량 부피 곡선(dose volume histogram, DVH)을 추출하였다. 추출된 DVH를 사용하여 modified Lymam model과 relative seriality model을 통해 NTCP를 계산하고 분석하였다. 결 과: 전체 환자의 방사선 폐렴과 심장 사망의 NTCP 값은 각각 0.5%, 0.7%로 낮은 수치를 보였다. 방사선 폐렴의 NTCP는 2문 조사법과 3문 조사법에 비해 Reverse Hockey Stick 법에서 높았다(0%, 0%, 3.1%, p<0.001). 방사선 폐렴의 NTCP 값은 중심폐거리가 커질수록 증가하였고, 심장 사망의 NTCP는 최대심장거리가 커질수록 증가하였다($R^2=0.808$). 결 론: 이차원 방사선치료의 방사선학적 지표들과 삼차원 입체조형방사선치료의 NTCP 값 사이에는 밀접한 관계가 있다. 이러한 연관성을 통해 과거의 부작용학률에 대한 자료들을 이차원 방사선치료의 방사선학적 지표들을 이용하여 NTCP 모델의 관점에서 재분석하는데 유용할 것으로 생각된다.

Treatment outcome and risk analysis for cataract after radiotherapy of localized ocular adnexal mucosa-associated lymphoid tissue (MALT) lymphoma

  • Park, Hee Hyun;Lee, Sea-Won;Sung, Soo Yoon;Choi, Byung Ock
    • Radiation Oncology Journal
    • /
    • 제35권3호
    • /
    • pp.249-256
    • /
    • 2017
  • Purpose: We retrospectively reviewed the results of radiotherapy for localized ocular adnexal MALT lymphoma (OAML) to investigate the risk factors of cataract. Methods: Sixty-seven patients with stage IE OAML treated with radiotherapy at Seoul St. Mary's Hospital from 2001 to 2016 were included. Median treatment dose was 30 Gy. Lens protection was done in 52 (76%) patients. Radiation therapy (RT) extent was as follows: superficial (82.1%), tumor mass (4.5%), and entire orbital socket (13.4%). The risk factors for symptomatic cataract were analyzed using the Cox proportional hazard model. Results: Median follow-up time was 50.9 months (range, 1.9 to 149.4 months). All patients were alive at the time of analysis. There were 7 recurrences and there was no local recurrence. Median time to recurrence was 40.4 months. There were 14 cases of symptomatic cataract. Dose >30 Gy had hazard ratio of 3.47 for cataract (p = 0.026). Omitting lens protection showed hazard ratio of 4.10 (p = 0.008). Conclusions: RT achieves excellent local control of ocular MALT lymphoma. Consideration of RT-related factors such as lens protection and radiation dose at the stage of RT planning may reduce the risk of RT-induced cataract after radiotherapy.

의료기관 형태별 방사선장해 방어행위 모형 (A Model for Protective Behavior against the Harmful Effects of Radiation based on Medical Institution Classifications)

  • 한은옥;권덕문;동경래;한승무
    • Journal of Radiation Protection and Research
    • /
    • 제35권4호
    • /
    • pp.157-162
    • /
    • 2010
  • 의료기관 영상의학과의 방사선사 1,322명을 대상으로 의료기관 형태별 방사선장해 방어행위에 영향을 미치는 요인을 설문조사하였다. 의료기관 형태별 방사선장해 방어행위 수준차이를 비교한 결과 병원과 의원은 차이가 없었고 대학병원과 종합병원이 병원과 의원에 비하여 평균이 높았다(p<0.001). 대학병원인 경우의 방사선장해 방어행위에 영향을 미치는 요인은 방사선장해 방어환경, 과제특수성 자기효능감, 자기효능감, 행위기대, 환자수, 교육회수, 방사선장해 방어태도로 나타났다($R^2$=0.528). 종합병원인 경우의 방사선장해 방어 행위에 영향을 미치는 요인은 방사선장해 방어환경, 행위기대, 방어태도로 나타났다($R^2$=0.686). 병원인 경우의 방사선장해 방어행위에 영향을 미치는 요인은 방사선장해 방어환경, 행위기대, 방어태도, 자기효능감으로 나타났다($R^2$=0.679). 의원인 경우의 방사선장해 방어행위에 영향을 미치는 요인은 방사선장해 방어환경 하나만 나타났다($R^2$=0.222).

이단중유연소 버너의 수치해석적 연구 (Flame simulation on the two stage heavy oil combustion)

  • 이승수;김혁주;박병식;김종진;최규성
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.209-214
    • /
    • 2002
  • Computations were performed to investigate the flow, temperature and pollutants in two stage heavy-oil combustion burner. The burner geometry and flow conditions were provided by a burner company. The goal of the study is to understand combustion phenomena according to each air inlet's velocity, excessive air ratio and air temperature through CFD. Air flow rates at two inlets are adjusted by a damper inside a burner. Here, injection conditions of liquid fuel are kept constant throughout all simulations. This assumption is made in order to limit the complexity of oil combustion though it may cause some disagreement. The final goal of this research is to design a Low-NOx heavy oil combustion burner through comparison between computational study and experimental ones. Besides experiments, simulation works can give us insights into heavy oil combustion and help us design a Low NOx burner while saving time and cost. The computational study is based on k-e model, P-1 radiation model(WSGGM) and PDF, and is implemented on a commercial code, FLUENT.

  • PDF

Thermal Radiation Pressure Force on Atmosphereless Bodies

  • Bach, Yoonsoo P.;Ishiguro, Masateru
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.64.1-64.1
    • /
    • 2019
  • Thermal fracture and cracking near the perihelion are found to be a possible mechanism to produce the dust trail of the near-Earth asteroid, (3200) Phaethon (Jewitt and Li, 2013, ApJ 771, L36). It is, however, not well understood how the debris particles were escalated from the regolith against the asteroid's gravity. Thus, the scenario that these debris particles are responsible for the detected activities (Li and Jewitt, 2013, ApJ, 145, 154), is not complete yet. Here, we hypothesize that the thermal radiation pressure around the perihelion passage would exert substantial force outwards from the regolith on dust grains, and they can be lifted up and contributes the dust tail formation with further help of solar radiation pressure. Our modeling indicates that particles with sizes of roughly ~1-10 micron can be ejected from Phaethon by the mechanism, while a detailed model of gravitational field is required for accurate estimation of the particle size range. Our idea is not necessarily limited to Phaethon case, but is applicable to any atmosphereless bodies.

  • PDF

Prognostic Significance of CYFRA21-1, CEA and Hemoglobin in Patients with Esophageal Squamous Cancer Undergoing Concurrent Chemoradiotherapy

  • Zhang, Hai-Qin;Wang, Ren-Ben;Yan, Hong-Jiang;Zhao, Wei;Zhu, Kun-Li;Jiang, Shu-Mei;Hu, Xi-Gang;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권1호
    • /
    • pp.199-203
    • /
    • 2012
  • Purpose: To evaluate the prognostic value of serum CYFRA21-1, CEA and hemoglobin levels regarding long-term survival of patients with esophageal squamous cell carcinoma (ESCC) treated with concurrent chemoradiotherapy (CRT). Methods: Age, gender, Karnofsky Performance Status (KPS), tumor location, tumor length, T stage, N stage and serum hemoglobin, and CYFRA21-1 and CEA levels before concurrent CRT were retrospectively investigated and related to outcome in 113 patients receiving 5-fluorouracil and cisplatin combined with radiotherapy for ESCC. The Kaplan-Meier method was used to analyze prognosis, the log-rank to compare groups, the Cox proportional hazards model for multivariate analysis, and ROC curve analysis for assessment of predictive performance of biologic markers. Results: The median survival time was 20.1 months and the 1-, 2-, 3-, 5- year overall survival rates were 66.4%, 43.4%, 31.9% and 15.0%, respectively. Univariate analysis showed that factors associated with prognosis were KPS, tumor length, T-stage, N-stage, hemoglobin, CYFRA21-1 and CEA level. Multivariate analysis showed T-stage, N-stage, hemoglobin, CYFRA21-1 and CEA level were independent predictors of prognosis. By ROC curve, CYFRA21-1 and hemoglobin showed better predictive performance for OS than CEA (AUC= 0.791, 0.704, 0.545; P=0.000, 0.000, 0.409). Conclusions: Of all clinicopathological and molecular factors, T stage, N stage, hemoglobin, CYFRA21-1 and CEA level were independent predictors of prognosis for patients with ESCC treated with concurrent CRT. Among biomarkers, CYFRA21-1 and hemoglobin may have a better predictive potential than CEA for long-term outcomes.

CBCT와 panorama 촬영시 위치에 따른 선량 비교 (Comparison of Dose Depending on the Position when Shooting Panorama and CBCT)

  • 정천수;김종일
    • 한국방사선학회논문지
    • /
    • 제7권3호
    • /
    • pp.175-179
    • /
    • 2013
  • 파노라마와 CBCT 같은 회전하는 방사선 발생장치에서 방사선작업종사자와 보호자의 적절한 피폭 방어 대책을 알아보고자 위치에 따른 방사선 조사선량을 비교 분석하였다. 사용된 장치로는 파노라마 DP-90-P PAX-500(Vatech, Korea)와 CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea)을 사용하였다. 조사선량 측정기는 Ion chamber model 2026과 Reader기 20X5-60E를 사용하였다. 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 실험결과 파노라마는 검사가 처음 시작하는 A지점이 81${\mu}R$ 으로 가장 높게 나왔고, 검사가 끝나는 D점이 53${\mu}R$ 으로 가장 낮게 나왔다. CBCT의 경우는 검사가 끝나는 D지점이 1,021${\mu}R$ 으로 가장 높게 나왔고, 검사가 시작하는 A지점이 809.67${\mu}R$ 으로 가장 높게 측정되었다. 부득이하게 보호자나 방사선작업종사자가 환자를 잡고 검사해야 할 경우에는 피폭선량이 가장 많은 지점을 피해서 X선관이 회전하기 시작하는 지점과 끝나는 지점의 가운데 위치해야 할 것이다. 그리고 장비의 특성상 기계의 반대편이며, 환자의 측면에서 지지하는 것보다 후방에서 지지하는 것이 가장 안전할 것이고, 적절한 방호기구를 착용해야 할 것이다.

Atomic displacement cross-sections for neutron irradiation of materials from Be to Bi calculated using the arc-dpa model

  • Konobeyev, A. Yu.;Fischer, U.;Simakov, S.P.
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.170-175
    • /
    • 2019
  • Displacement cross-sections for an advanced assessment of radiation damage rates were obtained for a number of materials using the arc-dpa model at neutron incident energies from $10^{-5}eV$ to 10 GeV. Evaluated data files, CEM03 and ECIS codes, and an approximate approach were applied for the calculation of recoil energy distributions in neutron induced reactions. Three sets of displacement cross-sections based on the use of low-energy data from JEFF-3.3, ENDF/B-VIII.0, and JENDL-4.0u were prepared. Files contain also cross-sections calculated using the standard NRT model. Special efforts were made to estimate the uncertainty of obtained displacement cross-sections.

방사선에 전신 조사된 마우스 음와 세포의 아포토시스 유도를 이용한 생물학적 선량 측정 모델 개발 연구 (Mouse model system based on apoptosis induction to crypt cells after exposure to ionizing radiation)

  • 김태환
    • 대한수의학회지
    • /
    • 제41권4호
    • /
    • pp.571-578
    • /
    • 2001
  • 방사선 피폭선량의 예측을 위한 방사선 민감 지표 모델 개발의 일환으로 apoptotic fragment assay법이 방사선에 피폭된 후 체내 피폭선량을 예측할 수 있는 지표로의 이용 가능성을 평가하기 위하여 코발트-60 감마선과 의료용 싸이크로트론 50MeV($p{\rightarrow}Be^+$) fast neutron 을 0.25Gy에서 1Gy의 선량을 마우스에 각각 전신 조사한 후 소장 음와세포내 apoptotic crypt cell의 수적 변화를 관찰하였다. 저선량 조사군에서 apoptotic crypt cell의 출현 빈도가 1Gy까지 급격하게 증가한 것으로 보아 방사선이 stem cell 지역에 있는 crypt cell의 형태학적 변화를 유발하는 것으로 나타났다. 이상의 결과는 아포토시스가 손상된 세포를 제거하므로 손상된 방사선 민감 표적 장기의 항상성 유지에 중요한 역할을 하는 것으로 판단되었다. Apoptotic fragments의 발생빈도에 대한 선량-반응 곡선에 있어서 음와세포는 중성자조사군이 $y=0.18+(9.728{\pm}0.887)D+(-4.727{\pm}1.033)D^2$ ($r^2=0.984$)으로, 반면에 감마선조사군은 $y=0.18+(5.125{\pm}0.601)D+(-2.652{\pm}0.7000)D^2$ ($r^2=0.970$)의 식을 얻었다. 이와 같이 중성자조사군과 감마선조사군은 공히 linear quadratic model 로 관찰되었다. apoptotic fragments 의 발생빈도와 조사 선량간에 유의한 효과가 있는 것으로 확인되었다. 이상의 결과에서 조사선량의 증가에 비례하여 방사선 민감 세포의apoptotic fragments 가 수적으로 증가하였으며, 고준위 방사선과 저준위 방사선은 선량 반응 관계식과 시간 경과에 따른 영향이 매우 유사하였으며, 마우스 음와세포의 apoptosis 유도에 대한 중성자선의 방사선 생물학적 효과비(RBE)는 2.072이였다. 그리고 모든 방사선조사군에서 방사선피폭 후 4시간과 6시간에 apoptosis 유도가 가장 많았으며, 음와세포의 형태학적 소견은 정상 대조군에서 관찰되지 않는 전형적인 apoptotic fragments 가 나타났다. 따라서 음와 세포에서의 아포토시스 유도는 방사선 피폭으로 발생된 세포 손상의 생물학적 영향 평가검색, 방사선 방호제의 민감도 검사, 방사성 동위원소의 체내 오염에 대한 체내 피폭선량 예측의 지표 및 방사선 민감 표적장기의 손상정도 파악에 이용 가능할 것임. Apoptotic fragment assay 법은 0.25Gy에서 1Gy 까지의 선량에서 간편하고 빠르며 재현성이 있는 지표로서 방사선 민감 표적 장기의 선량 반응 평가와 방사선 피폭후 조기 피폭선량 예측을 위한 방사선 생물학적 선량측정법의 좋은 지표로 사용할 수 있을 것으로 사료됨.

  • PDF