• 제목/요약/키워드: P loading

검색결과 1,478건 처리시간 0.025초

The effect of embryo catheter loading technique on the live birth rate

  • Omidi, Marjan;Halvaei, Iman;Mangoli, Esmat;Khalili, Mohammad Ali;Razi, Mohammad Hossein
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제42권4호
    • /
    • pp.175-180
    • /
    • 2015
  • Objective: Embryo loading (EL) is a major step in embryo transfer (ET) and affect on the success of in vitro fertilization (IVF). This study aimed to compare the effect of two different EL techniques on the rates of pregnancy and delivery in IVF/ET cycles. Methods: 207 fresh ET and 194 Frozen-thawed ET (FET) cycles were included in this retrospective study. Two groups (A and B) were defined based on the EL technique used. In group A, the entire catheter was flushed with Ham's F-10 medium. The embryos were then drawn into the catheter using one air bracket. In group B, $70{\mu}L$ of air was aspirated into the syringe and the catheter was flushed using Ham's F10 medium. The medium, air, embryos, air, and finally another layer of medium were then sequentially drawn into the catheter. The main outcome measures were the pregnancy and delivery rates. Results: The groups did not differ with respect to the etiology of infertility, the source of spermatozoa, the quality of the embryos, the type of EL catheter, and the ease of transfer. The pregnancy rate was similar between two groups. In fresh ET cycles, a higher delivery rate was observed in group B than it group A (78.1% vs. 60%, p=0.1). In FET cycles, the rate of delivery was significantly higher in group B than in group A to a nonsignificant extent (88.9% vs. 58.8%, p=0.06). Conclusion: EL techniques did not have a significant impact on the delivery rate in either fresh or FET cycles.

평판막 및 실관막 모듈에 의한 단백질의 친화성 크로마토그래피에 관한 연구 (A Study on Affinity Chromatography of Protein by Flat and Hollow-Fiber Membrane Module)

  • 이광진;염경호
    • 멤브레인
    • /
    • 제8권1호
    • /
    • pp.50-58
    • /
    • 1998
  • Polysulfone 재질의 다공성 평판막 및 실관막에 키토산 피막층을 형성시킨 후 반응성 염료인 Cibacron Blue 3GA를 고정화시켜 human serum albumin(HSA)의 결합용량이 최대 70 $\mu{g/cm}^2$인 단백질 친화성 막을 제조하였다. 친화성 평판막 모듈을 대상으로 HSA에 대한 용출 크로마토그래피 실험을 수행하여 eluent 용액의 최적 환경조건을 결정하였는바, 1M KCl이 첨가된 농도 0.06 M, pH 10의 universal buffer를 eluent로 사용했을 때 리간드와 결합된 단백질의 용출이 가장 우수하였다. 친화성 평판막 및 실관막 모듈을 대상으로 HSA의 전열 크로마토그래피 실험을 수행하여 단백질에 대한 동적 결합용량을 측정하였다. 이 결과 동적 결합용량은 평판막 모듈의 경우에는 loading 용액의 유량과 HSA의 농도가 증가함에 따라 평형 결합용량 값으로부터 크게 감소하였으나, 실관막 모듈의 경우에는 loading 용액의 유량과 HSA의 농도에 관계없이 항상 평형 결합용량 수준을 유지하였는바, 따라서 실관막 모듈이 평판막 모듈보다 단백질 친화성 크로마토그래피 분리관으로서 더 효과적이었다.

  • PDF

강우시 임하호 유입수 수질변동과 오염물질의 공간적 이동 특성 (Characteristics of Inflow Water Quality Variations and Pollutants Transport in Imha Reservoir during a Rainfall Event)

  • 이흥수;신명종;윤성완;정세웅
    • 한국물환경학회지
    • /
    • 제29권1호
    • /
    • pp.97-106
    • /
    • 2013
  • The temporal and spatial variations of water quality in a stratified reservoir are fully dependent on the characteristics of inflow loading from its watershed and the transport regimes of pollutants after entering the reservoir. Because of the meteorological and hydrological conditions in Korea, the pollutants loading to reservoirs are mostly occur during rainfall events. Therefore it is important to understand the characteristics of pollutants loading from upstream rivers and their spatial propagation through the stratified reservoir during the rainfall events. The objectives of this study were to characterize the water quality variations in upstream rivers of Imha Reservoir during a rainfall event, and the transport and spatial variations of pollutants in the reservoir through extensive field monitoring and laboratory analysis. The results showed that the event mean concentration (EMC) of SS, BOD, $COD_{Mn}$, T-N, T-P, $PO_4-P$ are 8.6 ~ 362.1, 2.5 ~ 5.1, 1.5 ~ 5.1, 1.1 ~ 1.9, 8.3 ~ 57.1, 5.6 ~ 25.7 times greater than the mean concentrations of these parameters during non-rainfall period. The turbidity and SS data showed good linear correlations, but the relationships between flow and SS showed large variations because of hysteresis effect during rising and falling periods of the flood. The ratio of POC to TOC were 12.6 ~ 14.7% during the non-rainfall periods, but increased up to 28.2 ~ 41.7% during the flood event. The turbid flood flow formed underflow and interflow after entering the reservoir, and delivered a great amount of non-point pollutants such as labile and refractory organic matters and nutrients to the metalimnion layer of reservoir, which is just above the thermocline. Spatially, the lateral variations of most water quality parameters were marginal but the vertical variations were significant.

오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향 (Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System)

  • 김형중;김선주;윤춘경
    • 한국농공학회지
    • /
    • 제39권5호
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

Effect of bond slip on the performance of FRP reinforced concrete columns under eccentric loading

  • Zhu, Chunyang;Sun, Li;Wang, Ke;Yuan, Yue;Wei, Minghai
    • Computers and Concrete
    • /
    • 제24권1호
    • /
    • pp.73-83
    • /
    • 2019
  • Concrete reinforced with fiber reinforced polymer (FRP) bars (FRP-RC) has attracted a significant amount of research attention in the last three decades. A limited number of studies, however, have investigated the effect of bond slip on the performance of FRP-RC columns under eccentric loading. Based on previous experimental study, a finite-element model of eccentrically loaded FRP-RC columns was established in this study. The bondslip behavior was modeled by inserting spring elements between FRP bars and concrete. The improved Bertero-Popov-Eligehausen (BPE) bond slip model with the results of existing FRP-RC pullout tests was introduced. The effect of bond slip on the entire compression-bending process of FRP-RC columns was investigated parametrically. The results show that the initial stiffness of bond slip is the most sensitive parameter affecting the compression-bending performance of columns. The peak bond stress and the corresponding peak slip produce a small effect on the maximum loading capacity of columns. The bondslip softening has little effect on the compression-bending performance of columns. The sectional analysis revealed that, as the load eccentricity and the FRP bar diameter increase, the reducing effect of bond slip on the flexural capacity becomes more obvious. With regard to bond slip, the axial-force-bending-moment (P-M) interaction diagrams of columns with different FRP bar diameters show consistent trends. It can be concluded from this study that for columns reinforced with large diameter FRP bars, the flexural capacity of columns at low axial load levels will be seriously overestimated if the bond slip is not considered.

Long-term Retrospective Clinical Study Comparing Submerged Type with External Hex Connection and Non-submerged Type with Internal Morse Taper Connection Implants

  • Kwoen, Min-Jeong;Kim, Sang-Yun;Kim, Young-Kyun
    • Journal of Korean Dental Science
    • /
    • 제12권1호
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose: This study was aimed to compare the survival and success rates, and long-term crestal bone loss according to the use of 2 connection types of dental implants (submerged-USII and non-submerged-SSII; Osstem $Implant^{(R)}$) by analyzing the change in alveolar bone height after 1 year under load and during final follow-up period. Materials and Methods: Between December 2004 and August 2008, patients with two types of Osstem implants (USII and SSII) were retrieved retrospectively. A total of 92 patients with 284 implants (USII=60, SSII=224) was finally selected. Their mean follow-up period was 7.5 years. The mesial and distal alveolar crestal bone changes were measured using radiographic images and the average was calculated at 1 year after loading and during final follow-up period. Result: Among the 284 implants, 4 USII and 7 SSII implants were removed, indicating 93.3% and 96.9% survival rates. Of the survived implants, mean crestal bone loss 1 year after loading was 0.39 mm for USII and 0.19 mm for SSII (P=0.018). During the final follow-up, mean crestal bone loss was 0.63 mm and 0.35 mm for USII and SSII, respectively, without statistical significance (P=0.092). According to the criteria for the success and failure of the implant by Albreksson and colleagues, final success rate was estimated as 86.7% for USII and 91.5% for SSII, respectively. Conclusion At 1 year after loading, the average crestal bone loss was significantly different between USII and SSII; however, both types met the criteria for implant success. During the final follow-up, both groups showed insignificant bone resorption patterns and did not show any pathological clinical symptoms. Therefore, both implants exhibited high long-term stability.

Recycled Polypropylene (PP) - Wood Saw Dust (WSD) Composites : The Effect of Acetylation on Mechanical and Water Absorption Properties

  • Khalil, H.P.S.A.;Shahnaz, S.B. Sharifah;Ratnam, M.M.;Issam, A.M;Ahmad, Faiz;Fuaad, N.A Nik
    • Journal of the Korean Wood Science and Technology
    • /
    • 제34권2호
    • /
    • pp.10-21
    • /
    • 2006
  • Recycled polypropylene (RPP) - Wood Saw Dust (WSD) composites with and without acetylation of filler were produced at different filler loading (15%, 25%, 35% and 45% w/w) and filler size (300, 212 and $100{\mu}m$). The RPP-WSD was compounded using a Haake Rheodrive 500 twin screw compounder at $190^{\circ}C$ at 8 MPa for 30 minutes. The mechanical properties and water absorption properties of modified and unmodified WSD-PP composites were investigated. Acetylation of WSD improved the mechanical and water absorption characteristic of composites. The decrease of filler size (300 to $100{\mu}m$) of the unmodified and acetylated WSD showed increase of tensile strength and impact properties. The composites exhibited higher tensile modulus properties as the filler loading increased (15% to 45%). However tensile strength, elongation at break and impact strength showed the opposite phenomenon. Water absorption increased as the mesh number and filler loading increased. With acetylation, lower moisture absorption was observed as compared to unmodified WSD. The failure mechanism from impact fracture of the filler-matrix interface with and without acetylation was analyzed using Scanning Electron Microscope (SEM).

Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns

  • Goldsworthy, H.M.;Gardner, A.P.
    • Structural Engineering and Mechanics
    • /
    • 제24권4호
    • /
    • pp.463-478
    • /
    • 2006
  • The design of structural frameworks for buildings is constantly evolving and is dependent on regional issues such as loading and constructability. One of the most promising recent developments for low to medium rise construction in terms of efficiency of construction, robustness and aesthetic appearance utilises concrete-filled steel tubular sections as the columns in a moment-resisting frame. These are coupled to rigid or semi-rigid connections to composite steel-concrete beams. This paper includes the results of a pilot experimental programme leading towards the development of economical, reliable connections that are easily constructed for this type of frame. The connections must provide the requisite strength, stiffness and ductility to suit gravity loading conditions as well as gravity combined with the governing lateral wind or earthquake loading. The aim is to develop connections that are stiffer, less expensive and easier to construct than those in current use. A proposed fabricated T-stub connection is to be used to connect the beam flanges and the column. These T-stubs are connected to the column using "blind bolts" with extensions, allowing installation from the outside of the tube. In general, the use of the extensions results in a dramatic increase in the strength and stiffness of the T-stub to column connection in tension, since the load is shared between membrane action in the tube wall and the anchorage of the bolts through the extensions into the concrete.

Extreme Learning Machine Approach for Real Time Voltage Stability Monitoring in a Smart Grid System using Synchronized Phasor Measurements

  • Duraipandy, P.;Devaraj, D.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1527-1534
    • /
    • 2016
  • Online voltage stability monitoring using real-time measurements is one of the most important tasks in a smart grid system to maintain the grid stability. Loading margin is a good indicator for assessing the voltage stability level. This paper presents an Extreme Learning Machine (ELM) approach for estimation of voltage stability level under credible contingencies using real-time measurements from Phasor Measurement Units (PMUs). PMUs enable a much higher data sampling rate and provide synchronized measurements of real-time phasors of voltages and currents. Depth First (DF) algorithm is used for optimally placing the PMUs. To make the ELM approach applicable for a large scale power system problem, Mutual information (MI)-based feature selection is proposed to achieve the dimensionality reduction. MI-based feature selection reduces the number of network input features which reduces the network training time and improves the generalization capability. Voltage magnitudes and phase angles received from PMUs are fed as inputs to the ELM model. IEEE 30-bus test system is considered for demonstrating the effectiveness of the proposed methodology for estimating the voltage stability level under various loading conditions considering single line contingencies. Simulation results validate the suitability of the technique for fast and accurate online voltage stability assessment using PMU data.

고온호기성 소화공정 배가스 처리를 위한 바이오필터 성능평가 (Performance Evaluation of Biofilter Treating Autothermal Thermophilic Aerobic Digestion Offgas)

  • 배병욱;최기승
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.732-739
    • /
    • 2010
  • Two combined autothermal thermophilic aerobic digestion (ATAD) and biofilter (BF) systems were operated to treat the piggery wastewater and the ammonia offgas. Experimental results indicated that the organic removal efficiency of ATAD-2, operated with oxygen, was higher than that of ATAD-1, operated with air. The concentration of ammonia in ATAD-2 offgas was higher compared to ATAD-1 offgas, but the total amount of ammonia produced from ATAD-2 was less than that from ATAD-1 due to the lower oxygen flowrate. The ammonia gas produced from both ATAD reactors was successfully removed by the BF. The BF-1, connected with ATAD-1, removed 93% of ammonia at the loading rate of $9.4g\;NH_3-N/m^3/hr$. The BF-2, connected with ATAD-2, removed 95% of ammonia gas at the loading rate of $8.1g\;NH_3-N/m^3/hr$. As the nitrification process continued, pH value of recirculating solution continuously decreased due to the accumulation of nitrate. When the ammonia loading rate was less than $22.7g\;NH_3-N/m^3/h$, the proper replacing cycle of recirculating solution was in the range of 10 to 11 days. Almost 90% of total mass of nitrogen fed into the each BF was confirmed from the mass balance on nitrogen.