• 제목/요약/키워드: P axis

검색결과 966건 처리시간 0.031초

임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향 (Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants)

  • 윤보혁;신현모;윤미정;허중보;정창모;강은숙
    • 대한치과의사협회지
    • /
    • 제53권9호
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

호흡기류 계측모듈의 교정과 성능 비교를 위한 실용적인 표준기류 생성 시스템 (A Practical standard Air Flow Generator System to Calibrate and Compare Performance of Two Different Respiratory Air Flow Measurement Modules)

  • 이인광;박미정;이상봉;김경옥;차은종;김경아
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.115-122
    • /
    • 2015
  • A standard air flow generator system was developed to generate air flows of various levels simultaneously applied to two different air flow transducer modules. Axes of two identical standard syringes for spirometer calibration were connected with each other and driven by a servo-motor. Linear displacement transducer was also connected to the syringe axis to accurately acquire the volume change signal. The user can select either sinusoidal or square waveform of volume change and manually input any volume as well as maximal flow rate levels ranging 0~3 l and 0~15 l/s, respectively. Various volume and flow levels were input to operate the system, then the volume signal was acquired followed by numerical differentiation to obtain the air flow signal. The measured volumes and maximal air flow rates were compared with the user input data. The relative errors between the user-input and the measured stroke volumes were all within 0.5%, demonstrating very accurate driving of the system. In case of the maximal flow rate, relatively large error was observed when the syringe was driven very fast within a very short time duration. However, except for these few data, most measured flow rates revealed relative errors of approximately 2%. When the measure and user-input stroke volume and maximal flow rate data were analyzed by linear regression analysis, respectively, the correlation coefficients were satisfactorily higher than 0.99 (p < 0.0001). These results demonstrate that the servo-motor controls the syringes with enough accuracy to generate standard air flows. Therefore, the present system would be very much practical for calibration process as well as performance evaluation and comparison of two different air flow transducer modules.

게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가 (The Evaluation of Clinical Usefulness on Application of Half-Time Acquisition Factor in Gated Cardiac Blood Pool Scan)

  • 이동훈;유희재;이종훈;정우영
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.192-198
    • /
    • 2008
  • Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.

  • PDF

섬유근통 증후군 환자에서 Somatomedin C (Insulin-Like Growth Factor 1)의 농도와 임상증상과의 관계 (A Controlled Study on Serum Insulin-Like Growth Factor 1 (Somatomedin C) Levels in Fibromyalgia)

  • 유병훈;강정권;오완수;연준흠;김정원;홍기혁;송찬우
    • The Korean Journal of Pain
    • /
    • 제12권1호
    • /
    • pp.27-35
    • /
    • 1999
  • Background: Fibromyalgia is a common syndrome of musculoskeletal pain and fatigue. Lacking distinctive histological or laboratory abnormality in diagnosis, it has often been considered a form of "psychogenic rheumatism". Fibromyalgia causes much distress to the affected patients and often frustrates physicians, who are unable to start rational therapy on any logical disease pathology. Methods: Growth hormone is essential for muscular homeostasis. In the present study, the notion that the stage-4 sleep anomaly typically seen in the fibromyalgia syndrome may disrupt growth hormone secretion was tested. Because growth hormone has a very short half-life, serum levels of somatomedin C were measured; somatomedin C is the major mediator of growth hormone's anabolic actions and is a prerequisite for normal muscle homeostasis. Serum levels of somatomedin C using acid-extraction procedure and two-site immunoradiome-tric assay (IRMA) and number of tender points were measured in 27 female patients with fibromyalgia from 40 to 60 years old and 27 healthy controls. Results: There were no differences in the concentration of somatomedin C between fibromyalgia patients and controls ($mean{\pm}SD$: $178.3{\pm}75.5$ ng/ml versus $166.3{\pm}76.6$ ng/ml; p=0.55). And there were no correlations between number of tender point and serum somatomedin C level by linear regression analysis. Conclusions: These findings did not support that there is a distinctive disruption of the growth hormone-somatomedin C neuroendocrine axis in a fibromyalgia syndrome. But we can not discard the hypothesis that disturbed sleep predispose to muscle pain.

  • PDF

Hot Wall Epitaxy (HWE)에 의한 $CdGa_2Se_4$ 단결정 박막 성장과 특성 (Growth and Characterization of $CdGa_2Se_4$ Single Crystal Thin Films by Hot Wall Epitaxy)

  • 최승평;홍광준
    • 센서학회지
    • /
    • 제10권6호
    • /
    • pp.328-337
    • /
    • 2001
  • 수평 전기로에서 $CdGa_2Se_4$ 다결정을 합성하여 HWE 방법으로 $CdGa_2Se_4$ 단결정 박막을 반절연성 GaAs(100) 위에 성장하였다. $CdGa_2Se_4$ 단결정 박막은 증발원과 기판의 온도를 각각 $630^{\circ}C$, $420^{\circ}C$로 성장하였다. 10K에서 측정한 광발광 exciton 스펙트럼과 이중결정 X-선 요동곡선(DCRC)의 반치폭(FWHM)을 분석하여 단결정 박막의 최적 성장 조건을 얻었다. Hall 효과는 van der Pauw 방법에 의해 측정되었으며, 온도에 의존하는 운반자 농도와 이동도는 293K에서 각각 $8.27{\times}10^{17}/cm^3$, $345\;cm^2/V{\cdot}s$였다. 광전류 봉우리의 10K에서 단파장대의 가전자대 갈라짐(splitting)에 의해서 측정된 ${\Delta}Cr$ (crystal field splitting)은 106.5 meV, ${\Delta}So$ (spin orbit splitting)는 418.9 meV였다. 10K의 광발광 측정으로부터 고품질의 결정에서 볼 수 있는 free exciton 과 매우 강한 세기의 중성 주개 bound exciton등의 피크가 관찰되었다. 이때 중성 주개 bound exciton의 반치폭과 결합 에너지는 각각 8 meV와 13.7 meV였다. 또한 Haynes rule에 의해 구한 불순물의 활성화 에너지는 137 meV 였다.

  • PDF

치근단육아종(齒根端肉芽腫)과 치근단양종(齒根端襄腫)의 전자현미경적(電子顯微鏡的) 연구(硏究) (AN ELECTRON MICROSCOPIC STUDY OF THE PERIAPICAL GRANULOMA AND THE PERIAPICAL CYST)

  • 여인호;임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제13권2호
    • /
    • pp.283-294
    • /
    • 1988
  • The purpose of this study was to investigate the characteristic features of the cells and tissues of the chronic periapical lesions using light microscope and electron microscope. Fifteen dental periapical lesions were obtained from the patients undergoing periapical surgery. Each specimen was divided into two parts along the tooth axis. One part was routinely processed for histopathologic examinations. 12 periapical lesions were diagnosed as granuloma and 3 periapical specimens as periapical cyst. The other part was fixed in 2.5% glutaraldehyde in 0.1M sodium cacodylate buffer at pH 7.4 and 1% osmic acid in same buffer. They were embedded in Epon 812. The semithin sections were used for the orientation of the lesions and the ultrathin sections were stained conventionally and examined with AEI Corynth 500 electron microscope. The results were as follows. 1. PMN and macrophages, which were dominant cell type, were scattered in small or large numbers throughout the central destructive area of granuloma. In the granulomatous area, plasma cells and lymphoytes were found in significant number and a lot of new capillary formation were revealed. Clefts caused by cholesterol were often seen in the connective tissue. Occasionally foam cells became collected in groups and epithelial proliferation were present. 2. In both granuloma and cyst, some plasma cells contained narrow cisternae of granular endoplasmic reticulum of which was tightly packed with electron dense materials, and other cells exhibited dilated profiles of granular endoplasmic reticulum. 3. In the area where plasma cells and lymphocytes were collected in groups, lymphocytes with well developed nucleolus and profuse cytoplasm were found and differentiating plasma cells were also present. 4. In the epithelial strands of the granulomatous area, epithelial cells contained enlarged endoplasmic reticulum, tonofilaments and ribosoms. Toward the intercellular space epithelial cells protruded a few microvilli. In the intercellular space, exudate-like electron dense materials, most of which was attached to the plasma membrane, appeared. 5. Some foam cells filled with numerous lipid droplets and others had lipid droplets and crystal-like structures. 6. Cyst epithelium consisted of bright cells and dark cells. The former had bright cytoplasm and small amounts of ribosoms, and the latter dark cytoplasm, many ribosoms, mitochondria and elongated microvilli. 7. Epithelial cells near the cyst lumen protruded a lot of long microvilli toward intercellular space and cyst lumen.

  • PDF

3차원 불균질 횡등방성 매질에 대한 탄성파 초동 주시 모델링 (Seismic First Arrival Time Computation in 3D Inhomogeneous Tilted Transversely Isotropic Media)

  • 정창호;서정희
    • 지구물리와물리탐사
    • /
    • 제9권3호
    • /
    • pp.241-249
    • /
    • 2006
  • 한국의 지질 환경은 암석 분포가 매우 다양하고 복잡한 구조 활동의 영향을 받아 지하매질의 이방성 특성이 국부적으로 심하게 변화한다. 기존의 이방성 주시 모델링의 경우 지질 모델을 2차원으로 단순화시킴으로써 이러한 복잡한 지질 환경을 제대로 고려할 수 없었다. 또한 약 이방성 가정을 사용하여 실제로 나타날 수 있는 지하 매질의 심각한 이방성 영향을 주시 모델링에서 고려할 수 없었다. 이에 이 연구에서는 보다 실제적이고 복잡한 3차원 횡등방성 매질(transversely isotropic media)에서 q-P파의 초동 주시 양상을 모사할 수 있는 주시 모델링 알고리듬을 개발하였다. 이 알고리듬에서는 2차원 비선형 주시 내삽(2D nonlinear traveltime interpolation) 기법과 주시의 3차원 격자 채움법(mapping)을 이용한 직접 전파법(direct calculation)을 통해 급격한 물성의 변화에도 주시 계산이 가능하도록 하였다. 또한, 최소 주시 계산과정에서 수치 미분을 통한 최대 경사법(steepest descent method)을 사용하여 약 이방성 가정을 극복하였다. 개발된 알고리듬은 해석해와 비교하여 그 타당성을 검증하였고 3차원 2층구조에 대한 주시 계산을 수행하여 물성이 급격히 변화하는 모델에 대해서도 안정적으로 주시 계산이 이루어짐을 확인하였다. 이 연구에서 개발한 3차원 주시 모델링 알고리듬은 향후 구조보정이나 토모그래피 알고리듬 개발에 사용될 수 있을 것으로 기대한다.

Effects of Korean Red Ginseng (Panax ginseng), urushiol (Rhus vernicifera Stokes), and probiotics (Lactobacillus rhamnosus R0011 and Lactobacillus acidophilus R0052) on the gut-liver axis of alcoholic liver disease

  • Bang, Chang Seok;Hong, So Hyung;Suk, Ki Tae;Kim, Jin Bong;Han, Sang Hak;Sung, Hotaik;Kim, Eun Ji;Kim, Myoung Jo;Kim, Moon Young;Baik, Soon Koo;Kim, Dong Joon
    • Journal of Ginseng Research
    • /
    • 제38권3호
    • /
    • pp.167-172
    • /
    • 2014
  • Background: Roles of immune reaction and toll-like receptor-4 (TLR-4) have widely been established in the pathogenesis of alcoholic liver disease (ALD). Methods: We evaluated the biologic efficacy of Korean Red Ginseng (KRG), urushiol, and probiotics (Lactobacillus rhamnosus R0011 and Lactobacillus acidophilus R0052) in mouse models of ALD. Sixty C57BL/6 mice were equally divided into six feeding groups for 10 weeks: normal diet, alcohol, control, alcohol + KRG, alcohol + urushiol, and alcohol + probiotics. Alcohol was administered via a LiebereDeCarli liquid diet containing 10% alcohol. TLR-4 expression, proinflammatory cytokines, and histology, as well as the results of liver function tests were evaluated and compared. Results: No between-group differences were observed with regard to liver function. TLR-4 levels were significantly lower in the KRG, urushiol, and probiotics groups than in the alcohol group ($0.37{\pm}0.06ng/mL$, $0.39{\pm}0.12ng/mL$, and $0.33{\pm}0.07ng/mL$, respectively, vs. $0.88{\pm}0.31ng/mL$; p < 0.05). Interleukin-$1{\beta}$ levels in liver tissues were decreased among the probiotics and KRG groups. The tumor necrosis factor-${\alpha}$ level of liver tissue was decreased in the KRG group. Conclusion: The pathological findings showed that alcohol-induced steatosis was significantly reduced by KRG and urushiol. As these agents improve immunologic capacity, they may be considered in potential anti-ALD treatments.

Evaluation of the fracture resistance of all-ceramic zirconia posts by 3 different methods

  • Jeong, Seung-Mi;Chung, Chae-Heon;Kang, Dong-Wan;Ludwig, Klaus;Kern, Matthias;Huels, Alfons
    • 대한치과보철학회지
    • /
    • 제38권6호
    • /
    • pp.757-764
    • /
    • 2000
  • Statement of the problem. All-ceramic post-and-core restorations offer a number of advantages compared with systems that use metal build-ups. In certain clinical cases, however, fractures at the joint between the post and core build-up have been reported. Purpose. The objective, therefore, is to improve the joint between the post and the core build-up. Material and methods. Three different methods were used to prepare all-ceramic post-and-core restorations; pressing IPS Empress core build-ups to CosmoPost zirconia posts, cement-ing IPS Empress core build-ups to CosmoPost zirconia posts and Celay-milling of zirconia blanks. A series of ten restorations was prepared for each of the three methods. The post-and-core complexes were tested to failure with the load applied perpendicular to the post axis. The load and deflection at fracture were recorded. Results. The highest breaking load and highest deflection were recorded for the cementing technique with values of 25.3 N and $394{\mu}m$, respectively, The corresponding values for the pressed core build-ups and the milled zirconia core build-ups were 22 N and $301{\mu}m$, and 13 N and $160{\mu}m$, respectively. All the differences are statistically significant (p=0.05). Regarding the load-dependence of the deflection, the cemented core build-ups again demonstrated the highest value with $15.5{\mu}m/N$. The difference in the values of $13.6{\mu}m/N\;and\;13{\mu}m/N$ recorded for the pressed-on and milled core build-ups, respectively, were statistically insignificant. Conclusion. In regard to the high fracture resistance of zirconia post, adhesive cementing the core build-up to the post offers a viable alternative to the conventional pressing technique. The elastic bond between the rigid high-strength zirconia post and the core build-up presents an additional advantage.

  • PDF

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).