• Title/Summary/Keyword: P and T-wave

Search Result 240, Processing Time 0.024 seconds

The Performance of Micro Fluxgate Sensor with Magnetic Core Shape (자성체 코어 형상에 따른 마이크로 플럭스게이트 센서의 검출 특성)

  • 조중희;최원열
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.508-514
    • /
    • 2004
  • A fluxgate magnetic sensor consists of a solenoid excitation coil, pick-up coil, and magnetic core. We presents the effect of magnetic core shape in a micromachined fluxgate sensor. To observe the performance of fluxgate sensor with magnetic core side width and gap, side width of 125 ${\mu}{\textrm}{m}$, 250 ${\mu}{\textrm}{m}$, and 500 ${\mu}{\textrm}{m}$ were designed in a rectangular-ring shaped core and the gaps of 0 ${\mu}{\textrm}{m}$, 50 ${\mu}{\textrm}{m}$, and 100 ${\mu}{\textrm}{m}$ were also fabricated in a racetrack shaped core. The solenoid coils and magnetic core were separated by benzocyclobutane(BCB) which had high insulation and good planarization characters. Copper coil patterns of 10 ${\mu}{\textrm}{m}$ width and 6${\mu}{\textrm}{m}$ thickness were electroplated on Ti(300 $\AA$) / Cu(1500 $\AA$) seed layers. 3 ${\mu}{\textrm}{m}$ thick N $i_{0.8}$F $e_{0.2.}$(permalloy) film for the magnetic core was also electroplated under 2000 gauss to induce the magnetic anisotropy. The magnetic core had the high DC effective permeability of ∼1,300 and coercive field of ∼0.1 Oe. Because the magnetic cores of 500 ${\mu}{\textrm}{m}$ side width and 0 gap had a low magnetic flux leakage, high sensitivity of ∼350 V/T were measured at excitation condition of 3 $V_{P-P}$ and 2 MHz square wave. The power consumption of ∼14 ㎽ was measured. The fabricated fluxgate sensor had the very small actual size of 3.0${\times}$1.7 $\textrm{mm}^2$. When two fluxgates were perpendicularly aligned in terrestrial field, their two-axis output signals were very useful to commercialize an electronic azimuth compass for the portable navigation system.m.m.m.

A Study on Predominant Periods and Attenuation Characteristics of Ground Motion (지반 탁월주기와 지반 운동특성에 관한 연구)

  • Kim, So-Gu;Cha, Jeong-Sik;Jeong, Hyeong-Sik
    • Geotechnical Engineering
    • /
    • v.11 no.2
    • /
    • pp.139-156
    • /
    • 1995
  • A set of field investigations was performed to estimate accurately the predominant periods of seismic 8round motions and the attenuation characteristics of the seismic ground vibration. Predominant periods of ground motions were estimated from the measurement of the continuous microseismic vibratins of certain periods, inherent in the ground and in the buildings, utilizing the high sensitivity digital velocity seismometer consisting of 3-component geophones and a digital seismograph. Estimated predominant periods of microseismic vibraion of the ground(measured on'the ground surface) and the building (measured on the second floor) were in the range of 0.18~0.235 sec. and 0.26~0.31 sec. respectively. The subsurface structure of the site ground was surveyed by the seismic refraction method utilizing the digital seismicwave probing system. The ground structure was found to be a two-layered system : an upper top soil layer of 7m in thickness with the P-wave velocity of 662m1sec and a lower layer of silty-clayey soils with the P -wave velocity of 2210m1 sec. The attenuation characteristics of the seismic ground vibrations were determined by the amplitude decay measurement method us;ng the Seisgun, which produces strong artificial seismic energy. Measured spatial attenuation coefficients of the ground vibration in vertical(Z) longitudinal(X), transverse(Y) direction were 0.1137, 0.0025, and 0.0290 respectively. Estimated Spartial QP's (inverse of the specific dissipation constant w.r.t. shear waved of X, Y, and Z directions were in the range of 5.913~7.575, 32.371~41.452, 2.794~3.579 re spectively. This indicates that aseimic design of the structures on the site should take stronger consideration regarding the earthquake resistance characteristics of the structures against longitudinal ground motion.

  • PDF

Reliability Based Pile Bearing Capacity Evaluation (신뢰도에 근거한 말뚝의 지지력 평가)

  • Lee, In-Mo;Jo, Guk-Hwan;Lee, Jeong-Hak
    • Geotechnical Engineering
    • /
    • v.11 no.1
    • /
    • pp.9-22
    • /
    • 1995
  • The purpose of this study is to propose safety factors of pile bearing capacity based on the reliability analysis. Each prediction method involves various degrees of uncertainties. To account for these uncertainties in a systematic way, the ratios of the measured bearing capacity from pile load tests to the predicted bearing capacity are represented in the form of a probability density function. The safety factor for each design method is obtained so that the probability of pile foundation failure is less than 10-3. The Bayesian theorem is applied in a way that the distribution using static formulae is assumed to be the A-prior and the distribution using dynamic formulae or wave equation based methods is assumed to be the likelihood, and these two are combined to obtain the posterior which has the reduced uncertainty. The results of this study show that static formulae of the pile bearing capacity using the 5.p.7. N-value as well as dynamic formulae are highly unreliable and have to have the safety factor more than 7.4 : the wave equation analysis using PDA(Pile Driving Analyzer) system the most reliable with the safety factor close to 2.7. The safety factor could be reduced certain amount by adoption the Bayes methodology in pile design.

  • PDF

Injection Laryngoplasty for The Treatment of Vocal Fold Scar, and Sulcus (성대구증 및 성대 반흔 환자에서 주사후두성형술의 효과)

  • Woo, Joo Hyun;Baek, Min Kwan;Kim, Dong Young;Park, Hyoung-Min;An, Sanghee;Moon, Kwang Ha;Cha, Heung Eog
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.27 no.1
    • /
    • pp.25-29
    • /
    • 2016
  • Background and Objectives : The clinical reports for the treatment of vocal fold scar and sulcus vocalis are limited, also there is no best one for the treatment of them. This study is to evaluate the effect of Injection laryngoplasty (IL) for the treatment of vocal fold scar and sulcus vocalis. Materials and Methods : from January 2013 to May 2015, the Nineteen patients who were diagnosed as vocal fold scar, sulcus and atrophy, and underwent IL, were engaged in this study. Clinical information and voice parameters were analyzed by retrospective chart review. Pre and post voice parameters were compared. Results : Subgroups of diagnosis were classified into sulcus vocalis for 12 patients, vocal fold scar for 5, and atrophy for 2. IL was performed under local anesthesia through cricothyroid membrane except one patient. Atesense$^{(R)}$, Radiessess$^{(R)}$, and Rofilan$^{(R)}$ were used as injected materials in 9, 9, and 1 patients respectively. Maximal phonation time (p=0.0124), dynamic range (p=0.0028), pitch range (p=0.0141), voice handicap index (p=0.028), glottal closure (p=0.0229), and mucosal wave (p=0.0132) had significant improvement for post-IL voice assessment than Pre-IL. While GRBAS, Mean flow rate, Jitter, Shimmer, Harmony to Noise ratio didn't have improvement. Conclusion : IL is a feasible option for the treatment of glottis incompetence with normally mobile vocal folds such as sulcus vocalis and vocal fold scar.

  • PDF

Studies in Biomechanical Properties on Brain-spinal Cord Response Mechanism by Human Posture Control Ability (자세조절능력에 따른 뇌-척수 신경 반응기전의 역학적 해석)

  • Yoo, Kyoung-Seok
    • 한국체육학회지인문사회과학편
    • /
    • v.58 no.6
    • /
    • pp.449-459
    • /
    • 2019
  • The purpose of this study is to identify how postural mechanics affects postural control on balance and stability by using frequency analysis technique from the kinematic data acquired during the one leg standing posture. For this purpose, the experimental group consisted of two groups, the normal group (n=6) and the national Gymnastics group (n=6). Displacement data of CoP were analyzed by frequency analysis of rambling (RM) and trembling (TR) by FFT signal processing. As a results, there was a significant difference in evaluating the stabilization index between the two groups with the eyes open and closed one leg stnading (p <.05). The cause of the difference was found to be the output of the maximum amplitude of RM (f1) and TR (f2) (p <.05). In particular, in the low frequency RM of 8-9 Hz, which is a natural frequency of signal wave involved in postural feedback feedback, the main frequency appeared to be performs the exercise mechanism of stable brain posture control. And in the high frequency TM of 120-135 Hz, it is considered that the adaptation of the reflective muscle response is minimized to minimize posture shaking. In conclusion, this study provides evidence for the intrinsic main frequencies according to the postural control ability which affects the CNS in one leg standing.

The Brain Temperature Change after the Use of Mobile Phone (휴대전화 사용 후 뇌 온도의 변화)

  • Koo, Eun-Jung;Lee, Il-Keun;Kong, Hea-Won
    • Annals of Clinical Neurophysiology
    • /
    • v.5 no.1
    • /
    • pp.16-20
    • /
    • 2003
  • Background: Mobile phone has become a very popular device used in everyday our lives. However, the possible hazard to human body such as brain tumor has been proposed intermittently. This unwanted possibility was calmed down due to the absence of definite evidence of hazard. This study was performed to see the effect of mobile phone use on the brain temperature. Methods: In 20 volunteers, we performed 4 steps of temperature measuring procedure. Four steps are pre-use (S1, basal state), wire-phone (S2, conventional telephone), PCS phone (S3, using 1,750~1,900 MHz), cellular phone (S4, using 820 MHz) states. Brain temperatures were measured by radiothermometer at 10 sites (5 sites in each hemisphere) of the brain after 5minutes of telecommunication through the phones. The final data were compared using paired t-test. Results: In PCS phone user group (Average; $35.73708^{\circ}C$), brain temperature decreased (with statistical significance, p<0.05), compared to those of non-user group (Average; $35.9527^{\circ}C$) or conventional wire phone user group. In cellular phone user group (Average; $35.82155^{\circ}C$), brain temperature decreased slightly (without statistical significance, p>0.05) compared to those of non-user group (Average; $35.9527^{\circ}C$) or conventional wire phone user group (Average; $35.922^{\circ}C$). The temperature change was not limited to the mobile phone applied side but on both hemisphere of the brain. Conclusion: In conclusion, mobile phone (especially PCS phone) decreased brain temperature in both hemispheres without side-to-side temperature difference. In addition, this study suggests possibility of radiothermometer application to the study of electromagnetic wave effect and protection method research in the future.

  • PDF

qEEG Measures of Attentional and Memory Network Functions in Medical Students: Novel Targets for Pharmacopuncture to Improve Cognition and Academic Performance

  • Gorantla, Vasavi R.;Bond, Vernon Jr.;Dorsey, James;Tedesco, Sarah;Kaur, Tanisha;Simpson, Matthew;Pemminati, Sudhakar;Millis, Richard M.
    • Journal of Pharmacopuncture
    • /
    • v.22 no.3
    • /
    • pp.166-170
    • /
    • 2019
  • Objectives: Attentional and memory functions are important aspects of neural plasticity that, theoretically, should be amenable to pharmacopuncture treatments. A previous study from our laboratory suggested that quantitative electroencephalographic (qEEG) measurements of theta/beta ratio (TBR), an index of attentional control, may be indicative of academic performance in a first-semester medical school course. The present study expands our prior report by extracting and analyzing data on frontal theta and beta asymmetries. We test the hypothesis that the amount of frontal theta and beta asymmetries (fTA, fBA), are correlated with TBR and academic performance, thereby providing novel targets for pharmacopuncture treatments to improve cognitive performance. Methods: Ten healthy male volunteers were subjected to 5-10 min of qEEG measurements under eyes-closed conditions. The qEEG measurements were performed 3 days before each of first two block examinations in anatomy-physiology, separated by five weeks. Amplitudes of the theta and beta waveforms, expressed in ${\mu}V$, were used to compute TBR, fTA and fBA. Significance of changes in theta and beta EEG wave amplitude was assessed by ANOVA with post-hoc t-testing. Correlations between TBR, fTA, fBA and the raw examination scores were evaluated by Pearson's product-moment coefficients and linear regression analysis. Results: fTA and fBA were found to be negatively correlated with TBR (P<0.03, P<0.05, respectively) and were positively correlated with the second examination score (P<0.03, P=0.1, respectively). Conclusion: Smaller fTA and fBA were associated with lower academic performance in the second of two first-semester medical school anatomy-physiology block examination. Future studies should determine whether these qEEG metrics are useful for monitoring changes associated with the brain's cognitive adaptations to academic challenges, for predicting academic performance and for targeting phamacopuncture treatments to improve cognitive performance.

Liquid Crystalline Technology of Cosmetic Industry and Moisturizing Effect of Skin (화장품 산업의 액정기술과 피부보습효과)

  • 김인영;조춘구;유희창
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.279-294
    • /
    • 2004
  • This study described about a liquid crystalline technology that is used in cosmetics industry. Various intermediate phases may exist between solid and liquid. At high surfactant concentration, several liquid crystalline phases can be made to have formed. Although molecular arrangement with crystallization is not regular, it is known that more relative regular state is liquid crystalline or meso-phase than liquid phase. Usually, it described in detail about manufacturing method that explained about a kind of liquid crystalline technology in cosmetics, a new liquid crystalline technology, and makes liquid crystalline. Specialty, it introduced about kind of special an emulsifier to form liquid crystalline. There were hydrogenated lecithin, ceramide, dipalmitoylhydroxyproline, DEA-cetyl phosphate, Gemini-surfactant in representative raw material to form liquid crystalline. Liquid crystalline extent that used polarization microscope to observe formation, and appears best from 400times, 600times, 1,000times well appeared. Also, droplet particle size that liquid crystal is made best 1.0-10.0$\mu\textrm{m}$ be. General emulsion more than superior result that measures the skin moisturizing effect to take advantage of liquid crystalline technology of vitamin was seen. As presence at a clinical result, wave and general emulsion more than superior result (more than 20%) that measures skin moisturizing effect about liquid crystalline of vitamin B$\_$5/ were seen (ANOMA t-test, p<0.05)

Evaluation of mode-shape linearization for HFBB analysis of real tall buildings

  • Tse, K.T.;Yu, X.J.;Hitchcock, P.A.
    • Wind and Structures
    • /
    • v.18 no.4
    • /
    • pp.423-441
    • /
    • 2014
  • The high frequency base balance (HFBB) technique is a convenient and relatively fast wind tunnel testing technique for predicting wind-induced forces for tall building design. While modern tall building design has seen a number architecturally remarkable buildings constructed recently, the characteristics of those buildings are significantly different to those that were common when the HFBB technique was originally developed. In particular, the prediction of generalized forces for buildings with 3-dimensional mode shapes has a number of inherent uncertainties and challenges that need to be overcome to accurately predict building loads and responses. As an alternative to the more conventional application of general mode shape correction factors, an analysis methodology, referred to as the linear-mode-shape (LMS) method, has been recently developed to allow better estimates of the generalized forces by establishing a new set of centers at which the translational mode shapes are linear. The LMS method was initially evaluated and compared with the methods using mode shape correction factors for a rectangular building, which was wind tunnel tested in isolation in an open terrain for five incident wind angles at $22.5^{\circ}$ increments from $0^{\circ}$ to $90^{\circ}$. The results demonstrated that the LMS method provides more accurate predictions of the wind-induced loads and building responses than the application of mode shape correction factors. The LMS method was subsequently applied to a tall building project in Hong Kong. The building considered in the current study is located in a heavily developed business district and surrounded by tall buildings and mixed terrain. The HFBB results validated the versatility of the LMS method for the structural design of an actual tall building subjected to the varied wind characteristics caused by the surroundings. In comparison, the application of mode shape correction factors in the HFBB analysis did not directly take into account the influence of the site specific characteristics on the actual wind loads, hence their estimates of the building responses have a higher variability.

Wind characteristics observed in the vicinity of tropical cyclones: An investigation of the gradient balance and super-gradient flow

  • Tse, K.T.;Li, S.W.;Lin, C.Q.;Chan, P.W.
    • Wind and Structures
    • /
    • v.19 no.3
    • /
    • pp.249-270
    • /
    • 2014
  • Through comparing the mean wind profiles observed overland during the passages of four typhoons, and the gradient wind speeds calculated based on the sea level pressure data provided by a numerical model, the present paper discusses, (a) whether the gradient balance is a valid assumption to estimate the wind speed in the height range of 1250 m ~ 1750 m, which is defined as the upper-level mean wind speed, in a tropical cyclone over land, and (b) if the super-gradient feature is systematically observed below the height of 1500 m in the tropical cyclone wind field over land. It has been found that, (i) the gradient balance is a valid assumption to estimate the mean upper-level wind speed in tropical cyclones in the radial range from the radius to the maximum wind (RMW) to three times the RMW, (ii) the super-gradient flow dominates the wind field in the tropical cyclone boundary layer inside the RMW and is frequently observed in the radial range from the RMW to twice the RMW, (iii) the gradient wind speed calculated based on the post-landfall sea level pressure data underestimates the overall wind strength at an island site inside the RMW, and (iv) the unsynchronized decay of the pressure and wind fields in the tropical cyclone might be the reason for the underestimation.