• Title/Summary/Keyword: Ozone Generated

Search Result 146, Processing Time 0.024 seconds

A Study of Electrolytic Ozone Generator for Ozone Asher (Ozone Asher용(用) Ozone Generator 개발연구(開發硏究))

  • Moon, Jae-Duk;Woo, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.648-651
    • /
    • 1993
  • A parallel plate type electrolytic ozone generator for ozone asher has been fabricated and studied, and 4 kinds of ozone generation anode electrode having different slits have also been investigated. It is found that there were optimum conditions for the slits of electrode, which, however, controls the field in the interelectrode spacing, and allows sideflow waterpaths through the slits in the electrode. As a result, the generated ozone concentrations of A, B, C and D type electrode showed 2.2, 1.3, 1.5 and 3.0 ppm for 400 ml/min flowrate tap water test, and, ozone yields of 11, 13, 15 and 30 $mg/kWhcm^2$ respectively.

  • PDF

Electrochemical Characteristics of a Water-Pen Point Discharge in Atmosphere (수성(水性)펜침방전(針放電)의 전기화학적(電氣化學的) 특성(特性))

  • Lee, Dae-Hee;Kim, Jin-Gyu;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1378-1381
    • /
    • 1995
  • Some interesting electrochemical characteristics of waterpen point-to-plate airgaps for dc and ac powers have been investigated at room atmosphere in a metal chamber. It is found that the ac discharge on the Pt point generated much ozone, while the negative do discharge on the waterpen point generated the highest ozone. And, the ac discharges of the waterpen point and the Pt point produced a little $NO_x$. But the dc discharge of the Pt point and waterpen point did not generated $NO_x$ anyway. As a result, it could be said that the water on the pen point acts something to generate ozone and $NO_x$ in room atmosphere.

  • PDF

A study of dissolved characteristics by ozone contactor type and ozone generated quantify (오존 접촉조 형태 및 오존발생량에 따른 용존 특성 연구)

  • Cho, Kook-Hee;Kim, Young-Bae;Kim, Hag-Gyu;Lee, See-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.239-241
    • /
    • 2003
  • The development of industry environment honored dust matter is diversify industry part eliminate the source of pollution besides usually life in and around pollution by livestock farming pollution matter and pollution by used agricultural medicines particular eutrophic of in and around a reservoir present of occurrence accelerate. The paper is a study of dissolved characteristics by ozone contactor type and ozone generated quantity.

  • PDF

Eletrochemical Characteristics of Ozone Generator using Boron-doped Diamond Electrode (붕소가 도핑된 다이아몬드전극을 이용한 오존발생기의 전기화학적 특성)

  • Oh, One-Gyun;Kim, Gyu-Sik;Einaga, Yasuaki;Fujishima, Akira;Park, Soo-Gik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.585-588
    • /
    • 2001
  • Thin. Boron-doped conducting diamond films are expected to be excellent electrodes for industrial electrolysis. Boron-doped conducting diamond films were used as anode for generating ozone gas by electrolysis of acidic solution. In this work, we have studied ozone generating system using Boron-doped Diamond electrode. Electrochemical cell and ozone generating system were designed for decreasing the temperature of the system. which was elevated during the reaction. by circulation of electrolyte in the system. In order to determine the ozone generation properties of diamond electrode. experimental conditions, electrolyte concentration, temperature, flow rate and reaction time were varied diversely. As a result, we could confirm that ozone gas was generated successfully and the performance of diamond electrode was stable while $PbO_2$ electrode was disintegrated. Actually we are found that ozone amount increased by lowering the temperature of electrolyte.

  • PDF

A study on the regulation and means of compliance for the ozone concentration in the cabin (항공기 객실 내 오존농도의 규제와 적합성 입증방안에 대한 연구)

  • Choi, J.W.;Park, J.H.;Kim, I.Y.;Kwak, Y.P.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.11 no.2
    • /
    • pp.79-92
    • /
    • 2003
  • This study is to identify the hazard of ozone and to evaluate ozone effect that is flowed into the cabin when the airplane is flying at high altitude. For this purpose, it is studied that how ozone is generated in the air, what the effect on human body is due to the cabin ozone and what the design criteria is considering or preventing the ozone hazard. And, finally the regulations and means of compliance are studied and introduced to assure that the aircraft satisfies the design criteria related to ozone.

  • PDF

Eletrochemical Characteristics of Ozone Generator using Boron-doped Diamond Electrode (붕소가 도핑된 다이아몬드전극을 이용한 오존발생기의 전기화학적 특성)

  • ;;Yasuaki Einaga;Akira Fujishima
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.585-588
    • /
    • 2001
  • Thin, Boron-doped conducting diamond films are expected to be excellent electrodes for industrial electrolysis. Boron-doped conducting diamond films were used as anode for generating ozone gas by electrolysis of acidic solution. In this work, we have studied ozone generating system using Boron-doped Diamond electrode. Electrochemical cell and ozone generating system were designed for decreasing the temperature of the system, which was elevated during the reaction. by circulation of electrolyte in the system. In order to determine the ozone generation properties of diamond electrode, experimental conditions, electrolyte concentration, temperature, flow rate and reaction time were varied diversely. As a result, we could confirm that ozone gas was generated successfully and the performance of diamond electrode was stable while PbO$_2$ electrode was disintegrated. Actually we are found that ozone amount increased by lowering the temperature of electrolyte.

  • PDF

Evaluation of Ozone Concentration for the Oxide Thin Film Growth

  • Park, No-Bong;Iim, Jung-Kwan;Park, Yong-Pil;Lee, Hee-Kab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.579-582
    • /
    • 2003
  • Ozone is usually generated from oxygen gas using a silent discharge apparatus and its concentration is less then 10 mol%. Ozone is condensed by the adsorption method, which is widely used for the growth of oxidation thin films such as superconductor. Highly condensed ozone is analyzed by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is most effective in the highly condensed ozone region and its method is superior to Q-mass analyzer for determining ozone concentration because of the simplicity of the method.

  • PDF

Time Dependant Ozone Generation due to Oxidation of the Surface of Corona Discharge Wires (코로나방전선 표면 산화에 따른 오존발생량의 경시특성)

  • Jung, Sung-Jin;Park, Seung-Lok;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.22-25
    • /
    • 2000
  • Time dependent ozone generation characteristics of some oxide layers grown by ozone on the surface of corona discharge wires have been investigated experimentally in air ambience. Four wires of stainless steel, iron, silver and copper were used for the corona discharge wire of an ozone generator. And the effect of the metal oxide layers on ozone generation was studied and the contamination morphology of each layers was characterized. With the SEM images and the EDS spectra, it was found that all the surface of the corona wire were oxidized by the generated ozone and contaminated by airborne particles through the gradient force. As a result, the morphology and the electrical property of metal oxide layer grown on corona wire surface influenced on ozone generation characteristics i.e. discharge mechanisms.

  • PDF

Effect of Gas Composition on Ozone Generation in Silent Discharge Process

  • Chung, Jae-Woo;Suh, Hyun-Hyo;Park, Hyun-Geoun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E4
    • /
    • pp.169-175
    • /
    • 2003
  • The effect of gas composition on the discharge characteristics and the ozone production in silent discharge (SD) process was investigated. The major gas components, $N_2$, $O_2$, and $H_2O$ influence the discharge properties according to their relative magnitude of ionization thresholds and electron affinities. The generated amount of ozone increased with the discharge energy by increasing the electron mean energy. The higher oxygen content injected, the higher ozone produced. A small amount of water vapor significantly lowered the discharge onset voltage by the ionization threshold decreasing effect and high electrical conductivity. However, the further increase of water vapor contributes to decrease the electron density by the electron affinity The addition of water greatly reduced the ozone generation through the formation of OH radical and the catalytic ozone destruction process.

Improvement of Ozone Yield by a Multi-Discharge Type Ozonizer Using Super position of Silent Discharge Plasma (무성방전의 중첩을 이용한 다중방전형 오존발생기의 오존생성수율 개선)

  • Song, Hyun-Jig;Lee, Dong-Heon;Oh, Jin-Hoon;Park, Seong-Wook;Seo, Young-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.88-91
    • /
    • 2004
  • In order to improve ozone generation, we experimentally investigated the silent discharge plasma and ozone generation characteristics of a multi-discharge type ozonizer. Ozone in a multi-discharge type ozonizer is generated by superposition of a silent discharge plasma, which is simultaneously generated in separated discharge spaces. A multi-discharge type ozonizer is composed of three different kinds of superposed silent discharge type ozonizers, depending on the method of applying power to each electrode. We observed that the discharge period of the current pulse for a multi-discharge type ozonizer can be longer than that of silent discharge type ozonizer with two electrodes and one gap.Hence, ozone generation is improved up to 17185 ppm and 783 g/kwh for the superposed silent discharge type ozonizer for which an AC high voltages with a 180 phase difference were applied to the internal electrode and the external electrode, respectively, with the central electrode being ground

  • PDF