• 제목/요약/키워드: Ozone Concentration

검색결과 758건 처리시간 0.031초

대구시 고농도 오존 사례일인 경우 대기 오염물질 농도의 일변화 특성 (Characteristics of Diurnal Variation of the Atmospheric Pollutants Concentration in High-Ozone Episode day in Daegu)

  • 손임영;윤일희;김희종
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1253-1259
    • /
    • 2002
  • This study analyzes the surface ozone, NO and $NO_2$ concentration data from 1997 to 1999 in Daegu. It investigates effect on precursor during high-ozone episode days. The high-ozone episode is defined when a daily maximum ozone concentration is higher than 100 ppb(ambient air quality standard of Korea) in at least one station among six air quality monitoring stations. The frequency of episodes is 13 days(33 hours). The frequency is the highest in May and September, and the area with the highest frequency is Nowondong and Manchondong. The average value of daily maximum ozone concentration with high ozone episode is 81.6 ppb, and that of 8-hour average ozone concentration is 58.6 ppb. It means that ozone pollution is continuous and wide-ranging in Daegu. The daily variation of NO, $NO_2$ and $O_3$ in high-ozone episodes are inversely proportional one another. Nowondong an industrial area, is affected by pollutants that are emitted from the primary sources, while Manchondong a residential area, is affected by the advection of $O_3$ or by the primary pollutants like VOCs.

Analysis of Ozone Concentration by TD and Q-mass Method

  • Lee, Dong-Gyu;Lee, Joon-Ung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제5권4호
    • /
    • pp.161-165
    • /
    • 2004
  • In order to get oxidizing power enough for growth of a superconductive thin film with oxide gas, concentrated ozone was used. As a method for concentrating ozone, a method for concentrating ozone by adsorbing ozone selectively into silica-gel beads is adopted, and this concentration is analyzed by the ultraviolet absorption method, the thermal decomposition method and the Q-mass analyzing method. Thermal decomposition method is most effective for measurement of a high concentration of ozone. Ozone as concentrated by the adsorption method got to have a concentration of 97 mol % at the maximum, and it was identified that the concentration of the ozone gas was stable for the time while a thin film was formed.

서울시 대기중 오존의 오염도와 그 영향인자 분석 (An Analysis of Influencing Factors on Ozone Concentration in the Ambient Air in Seoul)

  • 정용;장재연;권숙표
    • 한국대기환경학회지
    • /
    • 제2권1호
    • /
    • pp.73-79
    • /
    • 1986
  • This study is carried out to determine the concentration of the ozone and the factors affecting the variation of ozone concentration in the ambient air in Seoul. The one-hour average concentration of ozone $(O_3)$, sulfur dioxide $(SO_2)$, nitrogen oxides (NO and $NO_2$), suspended particulate (TSP), carbon monoxide (CO) and non-methane hydrocarbon (NMHC) at 5 sites in Seoul measured from September to October in 1983 and 1984 were analysed statistically along with meteorological data for the same period. The results were as follows; 1. The average concentrations of ozone at 5 sites during the period ranged from 3.3 to 9.1 ppb, they were below 20 ppb of the ambient air quality standard of Korea. 2. The maximum hourly concentration of ozone occurred between 2 and 3 p.m. in a day and concentration at night were very low but higher concentrations were observed at around 4 a.m. 3. The concentration ratio between NO and $NO_2$ in Seoul was relatively lower than that for the cities of foreign countries reported so far. 4. The ozone concentration has negative correlationships with the concentration of other primary pollutants$(SO_2, NO, NO_2, CO and NMHC)$ in simple regression analyses. 5. The ozone concentration was positively correlated to wind speed, temperature and insolation intensity but negatively correlated to relative humidity. 6. Stepwise multiple regression analysis of the ozone concentration to the pollutants and meteorological factors indicate that insolation intensity and $[NO_2]/[NO]$ were the primary influencing factors. 7. The three factors of insolation intensity, $[NO_2]/[NO] and NO_2$ concentration had a significant combined effect on the ozone concentration $(r^2 = 0.47-0.57)$.

  • PDF

고 에너지 방사선에 기인된 방사선치료실 내 평균 오존 농도의 변화 (Variation of Indoor Average Ozone Concentration within the Radiation Therapy Room by High Energy Radiation)

  • 이진국;이효영;임인철;유윤식
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.171-180
    • /
    • 2016
  • 본 연구는 고 에너지 방사선 조사에 기인된 방사선치료실 내 오존 농도의 변화를 비교 분석하고자 하였다. 이를 위하여 치료실 주변 대기 중 오존 농도와 치료실 내 배경 오존 농도를 분석하여 고 에너지 방사선 조사에 기인된 치료실 내 평균 오존 농도를 비교하였다. 치료실 내 배경 오존 농도는 평균 $17.4{\pm}7.9ppb$로 방사선치료실 주변의 대기 중 오존 농도(평균 $36.8{\pm}22.3ppb$)보다 약 50% 정도 통계적으로 유의하게 낮게 나타났다(p<0.05). 고 에너지 방사선 조사에 기인된 치료실 내 오존 농도는 방사선이 조사됨과 동시에 배경 오존 농도의 약 2배 수준으로 급격하게 증가되었으며 조사시간이 증가함에 따라 기울기가 일정한 증가 추이를 보이다가 약 130초에서 180초 부근에서 최대 오존 농도를 이루고 점차 포화되는 경향을 보였으며 배경 오존 농도로 감소하는데 소요되는 시간은 약 10분 이상이었다. 본 연구 결과를 토대로 고 에너지 방사선 조사에 기인된 방사선치료실 내 오존 농도는 후각을 자극하는 오존의 특이한 냄새를 맡거나 순간적인 호흡 곤란과 마른기침으로 가슴 통증 등의 신체적 증상이 나타날 수 있는 수준으로 밀폐된 방사선치료실에서 고농도 오존에 장시간 노출될 경우 폐 질환을 악화시킬 수 있기 때문에 각별한 주의가 요구된다.

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

부산 연안역의 야간 고농도 오존 발생 특성과 기상학적 관련성 (Characteristics of nocturnal maximum ozone and meteorological relevance in Pusan coastal area)

  • 전병일
    • 한국환경과학회지
    • /
    • 제8권3호
    • /
    • pp.287-292
    • /
    • 1999
  • This study was performed to investigate the characteristics of nocturnal maxiumu ozone occurrence and the meteorological relevance using to hourly ozone data and meteorological data for 1995~1996 in Pusan coastal area. Kwangbokdong showed the highest occurrence of nocturnal maximum ozone as 36.9%, and Deokcheondong showed the lowest occurrence(9.2%) for research period in Pusan. The occurrence rates of nocturnal maximum ozone concentration were decreased toward land area. The low maximum temperature, high minimum temperature, low diurnal range, high relative humidity, high wind speed, high could amount, low sunshine and low radiation were closely related to the main meteorological characteristics occuring the nocturnal maximum concnetration of ozone. It was shown that normal daily variation of ozone concentration by strong photochemical reaction at the before day of nocturnal maximum ozone. The concnetration of nocturnal maximum ozone were occured by entrainment of ozone from the upper layer of developed mixing layer. There are no ozone sources near the ground at night, so that the nighttime ozone should be entrained from the upper layer by forced convection.

  • PDF

연안 도시 대기오염 물질의 농도분포 특성 (Characteristics of Concentration Distribution of Coastal Urban Air Pollutants)

  • 박종길;석경하;김지형;차주완
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1243-1252
    • /
    • 2002
  • This paper aims to find the characteristics of concentration distribution of coastal urban air pollutants. For this purpose, It was used the daily meteorological data and the hourly concentration data for $O_3$and NO$_2$ in Busan metropolitan city from 1994 to 1996. It was investigated the annual and monthly distribution of ozone and nitrogen dioxide concentration at each site in Busan, and also investigated the characteristics of concentration change of air pollutants with time under the sea breeze. As a results, the concentration of nitrogen dioxide and ozone tend to be increased every year and nitrogen dioxide concentration is higher than ozone concentration at all sites in Busan. The concentration of ozone is high in summer season and low in winter season, but the concentration of nitrogen dioxide have a reversed trend. The monthly peak concentration of ozone occurred in April and September, while the monthly minimum concentration of nitrogen dioxide occurred in August. Their trend were identified by sites near the coastline than sites stands apart from the coastline. The sea breeze occurred annual mean 81 day in Busan from 1994 to 1996. The main wind direction of sea breeze was classified into southwesterly and southeasterly. In case of southwesterly, It was pronounced the south wind and southwest wind. In case of southeasterly, the occurrence frequency of east wind was high. Especially, the concentrations of urban air pollutants, such as ozone and nitrogen dioxide, were high on time which the sea breeze flow, and the areas that ozone concentration was high moved from outside part to central part of city with time. In costal urban such as Busan, the wind direction of sea breeze is influenced the change of ozone and nitrogen dioxide concentration on time which the sea breeze flow at each site and also influenced the change of air pollutants concentration of sites on the pathway of sea breeze.

외기 오존 농도에 따른 반도체 작업환경 및 사무실에서의 오존 농도 변화 연구 (A Study of Ozone Variations in a Semiconductor Fabrication Facility and Office Related to the Ozone Concentration in the Outdoor Air)

  • 이지은;정명구;최광민
    • 한국산업보건학회지
    • /
    • 제26권2호
    • /
    • pp.188-197
    • /
    • 2016
  • Objectives: The purpose of this study was to evaluate the ozone exposure levels and the variations in ozone concentration in a semiconductor fabrication facility and office in relation to the ozone concentration in the outdoor air. Methods: This study was performed in an office, semiconductor fabrication facility(such as etching, diffusion, diffusion plenum), and outdoors from June to August, 2015. Measurements were taken six times at the same places using an active sampler(pumped) and real-time equipment. Ozone monitoring by the active sampler method and analysis were carried out by OSHA Method ID-214. Real-time measurement was carried out by ozone measuring equipment using a non-dispersive ultraviolet absorption method. Results: Ozone concentrations in the semiconductor fabrication facility and office were 0.7~7.1 ppb in area samples and 0.72~4.07 ppb in real-time measurement, which were 0.88~8.88% of the occupational exposure limit. The concentration of ozone generated by a laser printer in the office was less than 2 ppb. There was not a significant difference between ozone concentrations before and after using the laser printer. The indoor/outdoor concentration ratio(I/O ratio) in the semiconductor fabrication facility and office was 0.05 and 0.06, respectively. Conclusions: All the samples contained ozone levels lower than the occupational exposure limit and it was confirmed that the concentration of outdoor ozone had no significant effect on indoor ozone concentration.

전산유체역학을 이용한 실규모 오존 접촉에서의 수리거동과 유효 체적 평가에 관한 연구 (Evaluating Effective Volume and Hydrodynamic Behavior in a Full-Scale Ozone Contactor with CFD Simulation)

  • 박노석;;;배철호;이선주
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.656-665
    • /
    • 2004
  • An Ozone reaction model combined with CFD(Computational Fluid Dynamics) technique was developed in this research, in the simulation of ozonation, hydrodynamic behavior as well as reaction model is important because ozone is supplied to treated water as gas ozone. In order to evaluate hydrodynamic behavior in an ozone contactor, CFD technique was applied. CFD technique elucidated hydrodynamic behavior in the selected ozone contactor, which consisted of three main chambers. Three back-mixing zones were found in the contactor. The higher velocities of water were observed in the second and third compartments than that in the first compartment. The flow of the opposite direction to the main flow was observed near the water surface. Based on the results of CFD simulation, the ozone contactor was divided into small compartments. Mass balance equations were established were established in each compartment with reaction terms. This reaction model was intended to predict dissolved ozone concentration, especially. We concluded that the model could predict favorably the mass balance of ozone, namely absorption efficiency of gaseous ozone, dissolved ozone concentration and ozone consumption. After establishing the model, we discussed the effect of concentration of gaseous ozone at inlet, temperature and organic compounds on dissolved ozone concentration.

고도정수처리공정에서 오존의 유기물 분해능 (Decomposition of Organic Matters by Ozonation in Advanced Water Treatment Process)

  • 윤태경;이강춘;노병일
    • 한국환경과학회지
    • /
    • 제14권3호
    • /
    • pp.327-333
    • /
    • 2005
  • The performance of ozone contactor in ozone-BAC advanced water treatment process was evaluated by the degree of decomposition of organic matters. The degree was measured by the analyses of $UV_{254}$ absorbance and the concentrations of DOC and BDOC for the sand filtered water and the ozone treated water, respectively. In addition, the ozone concentration in the contactor, required for the maximum BDOC concentration, was selected as the optimum concentration, and the appropriate residential time of ozone treated water in a reservoir was recommended based on the residual ozone concentration in the treated water. The following results were obtained from the pilot scale experiments. By ozonation $UV_{254}$ absorbance was decreased, and BDOC concentration was increased. The change of DOC concentration by ozonation was negligible, but the excess input of ozone resulted in the removal of the small amount of BDOC by complete oxidation. The optimum ozone concentration was 0.58mg $O_3/mg$ DOC. In order to remove residual ozone, 20minutes of the residential time were enough after ozonation.