• Title/Summary/Keyword: Oxygen permeation

Search Result 134, Processing Time 0.025 seconds

Sorption and Permeation Characteristics of Oxygen and Nitrogen for Polysulfone Hollow-Fiber Membrane (폴리폰설 중공사막에 대한 산소와 질소의 수착 및 투과특성)

  • 조정식;김종수;이광래
    • Membrane Journal
    • /
    • v.9 no.1
    • /
    • pp.25-35
    • /
    • 1999
  • The sorption and permeation experiments with $O_2$ and $N_2$ were performed with poly sulfone hollow-fiber membrane to obtain oxygen-enriched air. Sorption of $O_2$ on poly sulfone membrane was 1.5'||'&'||'not;2.0 times higher than that of N2. Sorption of oxygen and nitrogen in poly sulfone membrane was described satisfactorily with "dual-mode sorption model". In the low pressure range below 3kgr!cm', about 85% of total sorption was Langmuir-type sorption and only 15% was Henry-type sorption. In the higher pressure above 3kgf/${cm}^2$, Langmuir sorption sites became almost saturated and reached asymptote, and the increase in total sorption with pressurizing might be due to the Henry~type sorption. The ideal separation factor ( P $O_2$/ P $N_2$) was in the range of 2~4, while the actual separation factor for the mixture was reduced to the value of 1.7~2.2.2.2.

  • PDF

Oxygen Permeation and Syngas Production of La0.7Sr0.3Ga0.6Fe0.4O Oxygen Permeable Membrane (La0.7Sr0.3Ga0.6Fe0.4O 분리막의 산소투과특성 및 합성가스의 생성)

  • 이시우;이승영;이기성;정경원;김도경;우상국
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.594-600
    • /
    • 2003
  • L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ perovskite-type mixed conducting membranes, which could permeate oxygen selectively, have been fabricated and the microstructural features developed by varying the sintering conditions have been analyzed. The effects of surface modification and the membrane thickness on oxygen permeability have been evaluated under He/air environment. With increasing a grain boundary fraction, the overall oxygen permeability decreased. The syngas (CO+ $H_2$) has been produced by partial oxidation reaction of methane with the oxygen permeated through the membrane. Methane conversion and syngas yield have been evaluated as functions of the compositional ratio of feed gas and reaction temperature. In long-term duration test for 600 h, under C $H_4$+He/air environment, L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membrane showed a highly stable performance.

Oxygen Permeability and Resistance to Carbon Dioxide of SrCo0.8Fe0.1Nb0.1O3-δ Ceramic Membrane (SrCo0.8Fe0.1Nb0.1O3-δ 세라믹 분리막의 산소투과 특성 및 이산화탄소에 대한 내성)

  • Kim, Eun Ju;Park, Se Hyoung;Park, Jung Hoon;Baek, Il Hyun
    • Membrane Journal
    • /
    • v.25 no.5
    • /
    • pp.415-421
    • /
    • 2015
  • $SrCo_{0.8}Fe_{0.1}Nb_{0.1}O_{3-{\delta}}$ oxide was synthesized by solid state reaction method. Dense ceramic membrane was prepared using as-prepared powder by pressing and sintering at $1250^{\circ}C$. XRD result of membrane showed single perovskite structure. The oxygen permeability were measured under 0.21 atm of oxygen partial pressure ($P_{O_2}$) and between 800 and $950^{\circ}C$. The oxygen permeation flux of $SrCo_{0.8}Fe_{0.1}Nb_{0.1}O_{3-{\delta}}$ membrane was increased with the increasing temperature. The maximum oxygen permeation flux was $1.839mL/min{\cdot}cm^2$ at $950^{\circ}C$. Long period permeability experiment was carried out to confirm the phase stability and $CO_2$-tolerance of membrane containing Nb in the condition of air with $CO_2$ (500 ppm) as feed stream at $900^{\circ}C$. The phase stability and $CO_2$-tolerance of $SrCo_{0.8}Fe_{0.1}Nb_{0.1}O_{3-{\delta}}$ were investigated by XRD and TG analysis. The result of $SrCo_{0.8}Fe_{0.1}Nb_{0.1}O_{3-{\delta}}$ which exposed carbon dioxide for 100 hours indicated 8wt% of $SrCO_3$. But it was known that the level of $SrCO_3$ production dose not have a significant effect on oxygen permeability.

Temperature Dependence of Cr Impurity in La0.6Sr0.4Ti0.3Fe0.7O3-δ Coated Ba0.5Sr0.5Co0.8Fe0.2O3-δ Ion Conducting Membrane for oxygen Separation (산소 분리를 위한 La0.6Sr0.4Ti0.3Fe0.7O3-δ가 코팅된 Ba0.5Sr0.5Co0.8Fe0.2O3-δ 이온전도성 분리막에서 Cr 불순물의 온도 의존성)

  • Park, Yu Gang;Park, Jung Hoon
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.11-16
    • /
    • 2019
  • $La_{0.6}Sr_{0.4}Ti_{0.3}Fe_{0.7}O_{3-{\delta}}$(LSTF) coated $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$(BSCF) membranes which has properties of high oxygen permeability and stability to $CO_2$ were applied to a bench scale apparatus to conduct oxygen permeation experiments. Also, the membranes of the laboratory and the bench scale device were divided into three regions according to the temperature gradient in the membrane reactor for comparative analysis. While oxygen permeation experiment were conducted up to $900^{\circ}C$, temperature dependence of Cr deposition was investigated. As a result, it was confirmed that the oxygen permeability was $2.37ml/min{\cdot}cm^2$, which was significantly lower than $3.79ml/min{\cdot}cm^2$ measured in the laboratory apparatus. It was found through XRD and SEM/EDS analysis that the decrease in oxygen permeability was originated from the deposition of gaseous Cr on the membrane surface released from the alloy material of the housing. In particular, a large amount of Cr was found in the medium temperature region.

A Study on the Apparatus for Measuring Oxygen-Permeability of Membranes with a Multi-Electrode Oxygen Sensor (다전극 산소 센서를 이용한 고분자 막의 산소 투과도 측정 장치 연구)

  • Jeong, Il-Son;Jung, Jae-Chil;Kim, Tai-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.229-234
    • /
    • 2012
  • The existing permeability measurements based on pressure differential between the polymer membrane that is permeable to measure the amount of oxygen used, but these methods must be kept in a vacuum, and the measurement of the membrane with low permeability in the membrane is too time consuming. In recent years by using electrochemical method polymer membrane currents caused by the amount of oxygen is a measure of how much is used. In this study, apparatus consisting of one anode and six cathodes for multi-oxygen permeability tester used the same number of membranes produced by electrochemical oxygen permeation characteristics. In this study, one silver/silver chloride anode electrochemical method with a hexagonal sensor to put various kinds of polymer membranes with the six oxygen permeability for simultaneous measurement in real-time systems. Six cathodes (Pt), and one of the coil-shaped anode (Ag/AgCl) to form a hexagonal one of the polarographic oxygen sensor in a single measurement system by six sensors. Each sensor for making hexagonal specificity of the sensor to compensate for the conditions obtained in a pure nitrogen gas and pure oxygen gas conditions. With this study, self-developed hexagonal sensor capable of measuring sensors and oxygen permeability tester, for a multi-six different oxygen permeability characteristics of the membrane measured at the same time.

Synthesis and Application of $CeO_2-Sm_2O_3$ Solid Electrolyte Membranes with Electronic and Ionic Conductivities (전자 및 이온 전도성 $CeO_2-Sm_2O_3$ 고체 전해질 막의 합성 및 응용)

  • 현상훈;권재환;김승구;김계태
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.4
    • /
    • pp.355-363
    • /
    • 1998
  • The oxygen flux of SDC ($Sm_2O_3\;doped\;CeO_2$) solid electrolyte membranes with electronic and oxygen ion-ic conductivities has been investigated as a basic research in order to develop the conversion process of na-tural gas to syngas using the ceramic membrane reactor. Tube type membranes(1 mm thickness) were fa-bricated by slip casting of SDC powders prepared by the oxalate coprecipitaion method. Dense oxygen per-meation membranes(0.1 mm thickness) could be synthesized via sintering at $1450^{\circ}C$ for 2h and their re-lative density was over 95% The oxygen flux through SDC membranes doped 20mol% $Sm_15$ was about $1.13{\times}10^{-5}\;mol/m_2{\cdot}sec$ at low temperature around $800^{\circ}C$. In addition the SDC membranes showed a good thermaal stability for a long period of service.

  • PDF

Fabrication and Characterization of $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-\delta}$ Oxygen Permeation Membranes Prepared with Different Powders ($La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-\delta}$ 산소 투과 분리막의 제조 및 특성)

  • Lim, Kyoung-Tae;Lee, Kee-Sung;Han, In-Sub;Seo, Doo-Won;Hong, Kee-Seog;Bai, Kang;Woo, Sang-Kuk;Cho, Tong-Lae
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.10
    • /
    • pp.886-893
    • /
    • 2001
  • We synthesized $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-\delta}$ powders by coprecipitation, citration and solid-state reactions. The oxygen permeation membranes were fabricated by cold isostatic pressing of the synthesized powders, followed by sintering in air. All powders and membranes consist of perovskite phases. The coprecipitated powders showed the highest surface area ($7.5m^2/g$) but strontium deficiency was found during washing and filtering in the process. The membrane with lower relative density was fabricated by citration method. On the other hand, solid state reacted powders had high relative density (95%), and mechanical properties showed superior properties. Especially, the composition of the solid-state reacted powders was relatively well-controlled.

  • PDF

Characterization of Carbon Composite Bipolar Plates far Polymer Electrolyte Membrane Fuel Cells (고분자 전해질 연료전지용 탄소 복합체 Bipolar Plates의 기체 투과 특성 연구)

  • Hong Seong Uk;Kim Hyun Seon;Choi Won Seok;Kim Jeong Heon
    • Membrane Journal
    • /
    • v.15 no.2
    • /
    • pp.141-146
    • /
    • 2005
  • In this study, carbon composites were prepared using carbon graphite, thermoset resin, and carbon black. Oxygen permeability was measured using the continuous flow gas permeation analyzer as a function of composition and processing conditions. The experimental results showed that the oxygen permeability increased as the carbon black content increased, whereas the oxygen permeability decreased as the pressing time increased. The oxygen permeability was not affected by the processing pressure.