• 제목/요약/키워드: Oxygen generator

검색결과 138건 처리시간 0.023초

차량용 산소발생기의 성능 측정 (The Evaluation of Oxygen Generator Performance For Car)

  • 송근호;유진호;김정은;장화익;이광래
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.151-156
    • /
    • 2005
  • Auto exhausts and air pollution can become trapped in the cabin of vehicle, reducing the amount of oxygen available for breathing. Driver may feel sleepy, headaches, nausea, confusion, dizziness and lower levels of oxygen can damage the driver's general health. Consequently, oxygen generator purified oxygen into the car to help driver get the oxygen driver's body needs. In this study, in order to evaluate the oxygen generator performance, the samples that the various conditions(humidity(50%, 100%), flow and oxygen concentration) were examined. There were three types of oxygen generator; sample 1($2.5{\ell}/min$, $36%O_2$), sample 2($4.5{\ell}/min$, $41%O_2$) and sample 3($5{\ell}/min$, $39%O_2$). As the humidity increased from 50% to 100%, the oxygen concentration of the sample 1(36%), 2(41%) and 3(39%) was reduced $31%O_2$, $38%O_2$ and $38%O_2$, respectively. Also, the each sample measured that effect of human in car on oxygen concentration, if the oxygen concentration is one person in car, each sample of oxygen concentration was $20.8%O_2$, $23.7%O_2$ and $21.2%O_2$. From the above results, it was shown that oxygen generator for car, if the oxygen concentration is increased, effect of humidity is reduced, and that in the sample of supplying a high-rate of oxygen, the oxygen concentration is increased. It was suggested that effect of humidity on oxygen generator for car can be reduced according to the supply of oxygen.

  • PDF

The design of an ejector type microbubble generator for aeration tanks

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Membrane and Water Treatment
    • /
    • 제10권4호
    • /
    • pp.307-311
    • /
    • 2019
  • The ejector type microbubble generator, which is the method to supply air to water by using cavitation in the nozzle, does not require any air supplier so it is an effective and economical. Also, the distribution of the size of bubbles is diverse. Especially, the size of bubbles is smaller than the bubbles from a conventional air diffuser and bigger than the bubbles from a pressurized dissolution type microbubble generator so it could be applied to the aeration tank for wastewater treatment. However, the performance of the ejector type microbubble generator was affected by hydraulic pressure and MLSS(Mixed Liquor Suspended Solid) concentration so many factors should be considered to apply the generator to aeration tank. Therefore, this study was performed to verify effects of hydraulic pressure and MLSS concentration on oxygen transfer of the ejector type microbubble generator. In the tests, the quantity of sucked air in the nozzle, dissolved oxygen(DO) concentration, oxygen uptake rate(OUR), oxygen transfer coefficient were measured and calculated by using experimental results. In case of the MLSS, the experiments were performed in the condition of MLSS concentration of 0, 2,000, 4,000, 8,000 mg/L. The hydraulic pressure was considered up to $2.0mH_2O$. In the results of experiments, oxygen transfer coefficient was decreased with the increase of MLSS concentration and hydraulic pressure due to the increased viscosity and density of wastewater and decreased air flow rate. Also, by using statistical analysis, when the ejector type microbubble generator was used to supply air to wasterwater, the model equation of DO concentration was suggested to predict DO concentration in wastewater.

펄스전원에 의한 수산화가스 발생기에 관한 연구 (A Study on Analysis of the Hydrogen-Oxygen Gas Generator Using Pulse Power Supply)

  • 이정민;강병희;목형수;최규하
    • 전력전자학회논문지
    • /
    • 제6권5호
    • /
    • pp.377-385
    • /
    • 2001
  • 물을 전기분해하여 얻은 일정 부피비를 갖는 수소와 산소 혼합가스를 수산화가스로 명명하며, 이를 역반응시켜서 열 에너지원으로 사용하고 있다. 수산화가스는 경제성, 안전성 및 환경친화적인 고유한 특성을 지니고 있어서 현재 가스용접기에 적용하고 있으며 여러 가지 응용분야에 적용할 수 있도록 연구 중에 있다. 본 논문에서는 수산화가스의 특성에 관하여 고찰하고 발생기용 전원에 대하여 소개하고 이 중에서 아직까지 적용되지 않은 펄스전원을 적용하여 여러 가지 운전주파수에서 비교분석 하였다.

  • PDF

개인용 VSA방식 소형 산소발생기 개발 (Development of Personal Compact Oxygen Generator using Vacuum Swing Absorption)

  • 장준영
    • 한국산학기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.2479-2483
    • /
    • 2012
  • 본 논문은 휴대 및 이동이 가능한 개인용 소형 산소발생기 개발에 관한 것이다. 소형 산소발생기는 소형 진공펌프에 의해 진공흡착방식으로 작동된다. 각 구성품을 소형화와 경량화에 맞춰 구성하였으며 토출펌프 회전속도, 노즐 직경, 3-way 밸브 작동시간을 변화시키면서 산소농도와 유량을 최적화하였다. 노즐 직경 0.5mm에서 발생된 산소농도는 약 37%이며 유량은 $1{\ell}$/min이다. 노즐로부터 30cm 떨어진 위치에서 약 0.5%의 농도증가 효과가 나타났다.

항공기 승객용 화학적 비상산소 공급 및 조명시스템에 대한 연구 (Research for the Chemical Emergency Oxygen Supply and Lighting System for Aircraft Passengers)

  • 김영인
    • 한국항공운항학회지
    • /
    • 제30권2호
    • /
    • pp.55-60
    • /
    • 2022
  • A PSU (passenger service unit) is mounted on passenger seats in a cabin on an aircraft and consists of a crew call lamp, a reading lights, an information display lamp, an emergency oxygen generator, and an emergency oxygen mask. It is a safety device for providing convenience to passengers and providing oxygen to passengers in an emergency. This paper is a study on emergency oxygen supply systems and light systems of aircraft PSUs and a control device was developed to operate the system by analyzing the B767-300 aircraft's PSU circuit diagram. And the temperature generated by the B777-200ER aircraft's emergency oxygen generator was also measured by operating it directly. Through this, precautions for explaining the operation of an oxygen mask in an emergency were described and improvements were presented. Data acquired in these research processes can be used in the future to develop aircraft PSU (passenger service unit) and emergency oxygen generators.

A Generator of Gaseous Singlet Oxygen

  • Matsuura, Teruo;Sato, Hideya;Suzuki, Nobutaka;Matsumoto, Masakatsu
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.409-411
    • /
    • 2002
  • In order to prevent side reactions due to free radical formation occurring in the reactions of singlet oxygen generated in solution phse, it was required that singlet oxygen is generated in gas phase from an apparatus of a solid-gas system. We have accomplished to construct an apparatus generating singlet oxygen in solid-gas system, which is composed of a flexible optical fibre tube connected by a dye-sensitizer probe containing rose bengal dye on polymer or inorganic material. Through the optical fibre tube visible light from a laser and an oxygen stream are passed into the sensitizer probe where singlet oxygen is generated. The determination of singlet oxygen was carried out by two methods. One involves the detection of the luminescence of singlet oxygen at 1268 mn and the other involves the chemiluminescence reaction of a dihydroisobenzofuran with singlet oxygen emitting luminescence at 456 nm.

  • PDF

소화성능이 있는 질소발생기의 방사량 결정에 관한 실험적 연구 (An Experimental Study on the Determination of the Flow Rate for a Feasible $N_2$ Generator to Extinguish the Fire)

  • 장영근;김덕주;서병택
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.54-60
    • /
    • 2010
  • 본 연구는 할론 계열의 소화약제를 대체할 수 있는 청정소화약제인 질소가스를 생산하는 산업용 질소발생기를 사용하여 임의 방호구역에 대한 질소발생기의 방사압력에 따른 방사량을 결정할 수 있는 상관관계식을 실험적으로 결정하였다. 질소발생기의 방사량을 결정할 수 있는 상관관계식을 결정하기 위하여 간단한 방호구역을 제작하여 소형 질소발생기에서 발생하는 질소가스의 방사압과 방사량을 변화시키며 방호구역 내의 산소농도 변화를 실험적으로 파악하였다. 실험결과를 가지고 무유출인 경우 임의 방호구역에 대한 소화약제 방사량과 산소농도와의 관계를 정의한 이론식에 대하여 실험한 산소농도와의 차이를 분석하여 실험결과에 가장 근접하는 상관관계식을 결정하였다. 결정한 상관관계식은 임의 방호구역, 방사압력 및 방사량에 대하여 실험하여 검증한 결과 비교적 잘 일치하였다. 따라서 본 연구를 통하여 결정된 상관관계식을 이용하여 임의 방호구역에 대한 질소발생기의 방사량을 결정할 수 있는 방사량 결정 선도를 완성하였다.

산업용 질소발생기에 대한 청정소화설비로의 적용가능성에 관한 연구 (A Study on the Possibility of Application as a Natural Extinguishing System for $N_2$ Generator)

  • 서병택;장영근
    • 한국화재소방학회논문지
    • /
    • 제24권2호
    • /
    • pp.139-144
    • /
    • 2010
  • 본 연구에서는 산업용으로 일반적으로 사용하고 있는 질소발생기를 사용하여 할론 계열의 소화약제를 대체할 청정소화설비로 적용할 수 있는지에 대한 소화성능 실험을 간단히 수행하였다. 산업용 질소발생기의 소화성능을 분석하기 위하여 간단한 방호구역을 제작하여 실제 질소발생기에서 발생하는 질소가스를방사하면서 방호구역 내의 산소농도 변화를 실험적으로 파악하였다. 실험결과, 현재 많이 사용하고 있는 질소발생기로 방호구역 $100m^3$에 대하여 질소가스를 $5m^3$/min로 방사하면 3분 이내에 방호구역 내의 산소 농도를 15% 이내로 낮추어 질식소화가 충분히 가능하다.

의료용 산소발생기 제작을 위한 PSA 공정의 개발 (Development of PSA Process for Medical Oxygen Generator)

  • 최재욱;나병기
    • 청정기술
    • /
    • 제15권2호
    • /
    • pp.75-80
    • /
    • 2009
  • 공기 중에서 산소를 분리하기 위하여 2탑 PSA 공정을 이용한 4단계 기본공정 공급기체의 유량과 세정기체의 유량이 생성물의 순도와 유량에 미치는 영향을 살펴보았다. 4단계 기본 공정에 생성물가압 단계를 도입하면 생성물의 순도와 유량을 증가시키고, 압력균등화단계를 도입한 경우에는 생성물의 유량이 크게 증가한다는 사실을 확인할 수 있었다. 현재 상용화되어 있는 의료용 산소 발생기 사양인 5 ${\ell}/min$ 유량에서 순도 90%의 산소를 얻기 위해 시제품을 제작하여 산소의 순도 및 유량에 관한 실험을 수행하였다.

75톤급 액체로켓엔진 축소형 가스발생기 연소시험 (Hot-firing Tests of Subscale Gas Generator for 75 ton-class Liquid Rocket Engine)

  • 김문기;서성현;안규복;임병직;김종규;이광진;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.173-176
    • /
    • 2010
  • 75톤급 가스발생기 기술검증시제에서 나타난 산화제 분사기 차압의 증가 원인을 파악하기 위하여 축소형 가스발생기를 설계, 제작하였다. 설계점 및 탈설계점 시험 조건을 포함한 총 6회의 연소시험을 성공적으로 수행하였다. 연소시험 결과 연소압을 고정한 후 혼합비를 증가시킨 경우 연료 및 산화제 유량계수는 일정한 것으로 나타났으며, 혼합비를 고정한 후 연소압을 증가시킨 경우에도 연료 및 산화제 유량계수는 변함이 없는 것으로 파악되었다.

  • PDF