• 제목/요약/키워드: Oxygen flow rate

검색결과 689건 처리시간 0.028초

석면 대체용 셀룰로오스 단열재의 연소전이에 관한 연구 (Smouldering Combustion of Cellulose Insulation and Its Transition to Flaming Combustion)

  • 김홍;김기환
    • 한국안전학회지
    • /
    • 제7권3호
    • /
    • pp.14-21
    • /
    • 1992
  • The smouldering combustion of cellulose insulation treated with boric acid-borax-alum as combustion retardants are examined by Candle type combustibility tester. This sequence was examined quantitatively for longitudinal cylinder bed of cellulose insulation. Two configuration are possible, downward and upward smoulder spread ; both were investigated exprimentally. The smoulder spread velocity of cellulose insulation was 2.5cm/s -5.0cm/s in smoulder region. As results of critical oxygen content measurement, the effectiveness of alum as third combustion retardant are acceptable for flaming retardant effect. The phenomena of combustion transition are governed by quantity of commbustible gas generation In heating zone of cellulose insulation. The critial oxygen content are decreased with the increase of gas flow rate.

  • PDF

다양한 탄종별 자체발열 특성과 물성의 비교 분석 (Evaluation of self-heating propensity and its relation with fuel properties of various coals)

  • 김정수;이용운;임현수;박호영;류창국
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.83-85
    • /
    • 2013
  • With an increase in the use of low rank coals in power plants, various operational issues were raised in the fuel storage and supply, combustion, boiler and flue gas treatment systems. In the fuel storage and supply system, the main issue is the self-heating propensity of low rank coals leading to spontaneous combustion in yard storage, transport and pulverization. This study evaluated the reactivity of various sub-bituminous and bituminous coals with oxygen at low temperatures by analyzing the temperature increase characteristics of coals under a constant flow rate of oxygen supply. The results were quantified to a self-heating index and the relation with the fuel properties were evaluated.

  • PDF

Regeneration of Exhausted Activated Carbon by a Countercurrent Oxygen Reaction

  • 류건상;김태동;김유항
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권12호
    • /
    • pp.1447-1450
    • /
    • 1999
  • Countercurrent oxygen reaction (COR) was developed and evaluated for regeneration of exhausted activated carbon. Whether the regeneration technique is feasible or not is affected strongly by gradual loss and physical changes of activated carbon, energy consumption, and effective removal of adsorbed materials during the process. Various parameters such as reaction temperature, the loss of activated carbon, surface area, pore volume, surface structure, adsorptive property, etc. were examined to determine the effectiveness of COR. The results of these tests showed that the parameters were strongly dependent on oxidant flow rate, and suggest that the newly developed COR is comparable and, in some ways, possibly superior to conventional regeneration techniques because the overall process runs in a single step and is less energy intensive, and also because the adsorptive capacity of exhausted activated carbon was completely recovered.

Verneuil법에 의한 $TiO_2$를 첨가한 Sapphire 단결정 성장과 결함에 관한 연구 ($TiO_2$ Doped Sapphire Single Crystal Growth by Verneuil Method and Study for Defects)

  • 조현;최종건;전병식;오근호;박한수
    • 한국세라믹학회지
    • /
    • 제31권12호
    • /
    • pp.1423-1428
    • /
    • 1994
  • TiO2 doped sapphire single crystals were grown by Verneuil method. The doping amount of TiO2 to Al2O3 were varied 0.1, 0.2, 0.3 wt% respectively. The grown crystals have reddish color and somewhat transparent. Optimum growth condition was established by changing growth rate and gas flow ratio. Growth condition are as follows; The flow rate range of oxygen ws 5.0~7.3 ι/min and that of hydrogen was 16~25ι/min and average growth rate was 6~8mm/hr. The basic cause of color appearence and defects in crystal were studied.

  • PDF

수면 무호흡증 관리를 위한 섬유센서 기반의 슬립 모니터링 스마트 웨어 개발에 관한 연구 (A Study on the Development of Sleep Monitoring Smart Wear based on Fiber Sensor for the Management of Sleep Apnea)

  • 박진희;김주용
    • 감성과학
    • /
    • 제22권1호
    • /
    • pp.89-100
    • /
    • 2019
  • 본 연구에서는 수면무호흡증이 다양한 합병증을 유발하는 질병으로서, 이를 위한 표준화된 수면다원검사가 고가이며 측정이 불편함을 고려하여, 환자가 익숙한 환경에서 검사를 받을 수 있도록 스트레치 섬유센서를 이용한 무구속 상태의 웨어러블 모니터링 시스템을 개발하고자 한다. 또한, 의복과 일체화된 디자인으로 제품화하여 그 유용성을 제안하고자 한다. 성인 남성용 롱 슬리브 티셔츠 형태로 착용형 수면무호흡 모니터링 스마트 의류를 개발하여, 수면무호흡 진단 지표 중 섬유형 센서를 기반으로 측정하는 호흡수(breathing rate)측정용 섬유센서, 산소포화도(oxygen saturation), 호흡기류(airflow)를 실시간 측정하였다. 최적의 조합비 샘플 4가지를 통한 gauge factor를 측정한 결과, gauge factor 20.3을 확인하였고, 3회 숨을 크게 내쉴 때 호흡유량이 최대 2048ml였다. 산소포화도 69.45%로 최소 측정 가능 산소포화도 70% 정도의 결과를 나타내었다. 세탁 후 인장에 따른 센서 성능 평가 결과는 전체적으로 gauge factor 18 수준의 값으로, 세탁에 대한 내구성이 입증되었다. 본 연구를 통하여 수면무호흡증 환자의 수면효율이 떨어지고 여러 합병증을 동반하는 문제에 대해, 가정에서 쉽게 사용할 수 있는 착용형 수면무호흡 모니터링 스마트 의류를 개발하여 호흡수, 호흡유량, 산소포화도의 3가지 지표를 측정 가능함을 확인하였다.

케미컬루핑 연소시스템을 위한 산소전달입자의 상온-상압 고체순환특성 (Solid Circulation Characteristics of Oxygen Carrier for Chemical Looping Combustion System at Ambient Temperature and Pressure)

  • 윤주영;김하나;김정환;이도연;백점인;류호정
    • 한국수소및신에너지학회논문집
    • /
    • 제28권4호
    • /
    • pp.384-391
    • /
    • 2017
  • Effects of operating variables on solid circulation rate were measured and discussed using two-interconnected circulating fluidized bed system at ambient temperature and pressure. OCN 706-1100 particles were used as oxygen carrier. The measured solid circulation rates increased as the lower loop seal gas flow rates and the solid height in the fuel reactor increased. Suitable operating conditions to avoid choking of the air reactor were confirmed. Continuous long-term operations of steady-state solid circulation were also demonstrated at two different conditions based on the operating window.

인공폐(산화기) 제작과 실험 (Design & Animal Experiment of Artificial Oxygenator)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • 제15권2호
    • /
    • pp.259-265
    • /
    • 1982
  • We have designed a new type of bubble oxygenator (KOREA-KIM VENOTHERM OXYGENATOR) made of PVC sheet and deforming mesh incorporated in the heat exchanger, and evaluated in experimental animal for the analysis of it`s efficiency. The Oxygenator has low priming volume with high flow rate up to 6 L/rain, and efficiency of heat exchanger was excellent as 1-$1.5^{\circ}C.$ using total cardiopulmonary bypass method under moderate to deep hypothermia. Average priming volume of 1317 ml with 30% hemodilution method was perfused with an average of 1.1-3.0 L/min.$M^2$of arterial blood and pure oxygen at a rate of 2-3.4 L/min for 49.6 minutes continuously in average. During total cardiopulmonary bypass, average $PaO_2$ was $159.8{\pm}60$mmHg, $PaCO_2$ $41.0{\pm}3$mmHg respectively under $SaO_2$ over 96% with systolic arterial pressure of 70 mmHg and CVP of 5-10 cm$H_2O$. Plasma free Hemoglobin was $7.0{\pm}4$ mg/dl with 25% drop of hemoglobin and hematocrit at the end of cardiopulmonary bypass. This KKV Oxygenator was observed to have excellent capabillty of oxygen and carbon dioxide gas transfer with small amount of blood trauma, and the efficiency of heat exchanger was satisfactory during cooling and rewarming of the bubbled blood. Disadvantages have included the somewhat poor deforming effect due to loose PVC fiber mesh, the extracompact character of Teflon filters, and the rough inner surface of the heat exchanger copper pipes.

  • PDF

Verneuil법에 의한 $SrTiO_3$ 단결정 성장 ($SrTiO_3$ Single Crystal Growth by Verneuil Method)

  • 최익서;조현;최종건;오근호
    • 한국세라믹학회지
    • /
    • 제29권9호
    • /
    • pp.689-694
    • /
    • 1992
  • Strontium Titanate single crystal is grown by Verneuil method. Feed materials were prepared by coprecipitation method which started with Sr(NO3)2 and TiCl4. SrTiO3 can not be grown from feed materials having the stoichiometric components due to volatilization of SrO, when the powder added more 3 wt% SrO used, the crystal can be grown. Growth conditions that the pressure of oxygen and hydrogen gas was 5 psi, the flow rate of oxygen and hydrogen was 7.3 and 30ι/min respectively, the growth rate was 20 mm/hr were optimum. The grown single crystal has the diameter of 10~15 mm and its length is 30~40 mm. The grown crystal was deep brown color and somewhat transparent. The color of grown crystal was lightened after annealing.

  • PDF

Ablation of Polypropylene for Breathable Packaging Films

  • Sohn, Ik-Bu;Noh, Young-Chul;Choi, Sung-Chul;Ko, Do-Kyeong;Lee, Jong-Min;Choi, Young-Jin
    • 한국레이저가공학회지
    • /
    • 제9권3호
    • /
    • pp.15-21
    • /
    • 2006
  • A Polypropylene (PP) film was ablated using a femtosecond laser with a center wavelength of 785 nm, a pulse width of 184 fs and a repetition rate of 1 kHz. Increments of both pulse energy and the shot number of pulses lead to co-occurrence of photochemical and thermal effect, demonstrated by the spatial expansion of rim on the surface of PP. The shapes of the laser-ablated PP films were imaged by a scanning electron microscope (SEM) and measured a 3D optical measurement system (NanoFocus). And, the oxygen transmission rate (ORT) of periodically laser-ablated PP film were characterized by oxygen permeability tester for modified atmosphere packaging (MAP) of fresh fruit and vegetable. Our results demonstrate that femtosecond pulsed laser is efficient tools for breathable packaging films in modifying the flow of air and gas into and out of a fresh produce container, where the micropatterns are specifically tailored in size, location and number which are easily controlled by laser pulse energy and pulse patterning system.

  • PDF

용존산소 제한 또는 탄소원 제한 조건의 유가식배양에서의 Cyclosporin A 생합성 연구 (Studies of Cyclosporin A Biosynthesis under the Conditions of Limited Dissolved Oxygen or Carbon Source in Fed-batch Culture)

  • 전계택;박성관;권호균;정연호;정용섭;장용근;이영행
    • KSBB Journal
    • /
    • 제13권2호
    • /
    • pp.203-208
    • /
    • 1998
  • We investigated the effects of dissolved oxygen (D.O.) and fructose (C-source) on cell growth and biosynthesis of cyclosporin A (CyA) produced as a secondary metabolite by a wild-type filamentous fungus, Tolypocladium inflatum. This was performed by controlling the level of D.O. and the residual C-source, as required, through adjustment of medium flow rate, medium concentration and agitation rate in fed-batch cultures. CyA production was furned out to be maximal, when D.O. level was controlled around 10% saturated D.O. and concentration of the C-source was maintained sufficiently low (below 2 g/L) not to cause carbon catabolite repression. Under this culture condition, we obtained the highest values of CyA concentration (507.14 mg/L), Qp (2.11 mg CyA/L/hr), $Y_x/s$ (0.49 g DCW/g fructose), $Y_p/s$<(22.56 mg CyA/g fructose), and YTEX>$_p/x$ (48.31 mg CyA/g DCW), but relatively lower values of cell concentration (11.98 g DCW/L) and cell productivity (0.043 g DCW/L/hr), in comparison with other parallel fed-batch fermentation conditions. These results implied that, in the carbon-limited culture with 10% saturated D.O. level, the producer microorganism utilized the C-source more efficiently for secondary metabolism.

  • PDF